Tender For Repairs / Maintenance Of Split / Window Type Ac, Water Cooler, Desert Cooler, Deep Freezers And Refrigerator For Area-I At Af Stn Jaisalmer, jaisalmer-Rajasthan

Military Engineer Services-MES has published Tender For Repairs / Maintenance Of Split / Window Type Ac, Water Cooler, Desert Cooler, Deep Freezers And Refrigerator For Area-I At Af Stn Jaisalmer. Submission Date for this Tender is 23-05-2024. Air Cooler Tenders in jaisalmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43318251
Tender For Repairs / Maintenance Of Split / Window Type Ac, Water Cooler, Desert Cooler, Deep Freezers And Refrigerator For Area-I At Af Stn Jaisalmer
Open Tender
Indian
Rajasthan
jaisalmer
23-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repairs / Maintenance Of Split / Window Type Ac, Water Cooler, Desert Cooler, Deep Freezers And Refrigerator For Area-I At Af Stn Jaisalmer

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
ca7c505e-46db-4b97-a48a-cd96b2f43a64.html Tender Notice 0 KB
BOQ_730684.xls Tender Document 0 KB
Tender8202.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIRS/MAINT OF SPLIT/ WINDOW TYPE AC, WATER COOLER, DESERT COOLER, DEEP FREEZERS AND REFRIGERATOR FOR AREA-IAT AF STNJAISALMER
Sl. No. Item Description
1M&L for cleaning of complete body including fitting and fixture of desert cooler of capacity 4000/5000 Cum/hours of any make with wire brush or scruber including removal of all sludges, loose paint dust, dirt etc and prepared the clean surface for painting,applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank complete all as specified and directed.
2Taking out fan motor single phase, 230 Volts, 1400 RPM, 3 Speed 1/6 HP to 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and re-fixing in same position ccomplete all as specified and directed.
3M&L for front grill/louvers to desert cooler made out from 0.80 mm thick Galvanised Iron sheet suitable for 5000/4000 Cum/hours capacity desert cooler of any make fixed in repair complete all as specified and directed.
4M&L for selector switches three way, 230 volts single phase of standard quality fixed in desert coolers fixed in repair complete all as specified and directed.
5M&L for Wood pad, minimum weight 0.80 Kg, fixed in side panels of desert coolers including taking down old unserviceable complete all as specified and directed.
6M&L for Desert cooler motor of three speed, 1380 RPM, 230 volts, copper winding single phase with aluminium fan blade, ring, side legs, necessary bolts and nuts of capacity 1/6 to 1/8 HP including taking down old unserviceable complete all as specified and directed.
7M&L for Plug top, three Pin, 5/6 Amps, 230 volts, ISI Marked including taking down old unserviceable complete all as specified and directed.
8M&L for switch piano type, 240 volts, Singe Pole, one ways, 5/6 Amps, ISI Marked, fixed in desert coolers including taking down old unserviceable complete all as specified and directed.
9M&L for 1.50 sqmm, PVC insulated and sheathed round flexible three core copper conductor cable including necessary connection fixed in desert coolers including taking down old unserviceable complete all as specified and directed.
10S&F of capacitor 4 MFD for fan motor of desert cooler with ISI Marked including taking down old unserviceable complete all as specified and directed.
11S&F of Mild Steel Sheet body of 22 gauge suitable for coolers of capacity 4000/5000 Cum/hour including taking down old unserviceable complete all as specified and directed.
12S&F of side shutter made out from 0.80 mm thick galvanised iron sheet of capacity 4000/5000 cum/hours desert cooler fixed as in repair complete all as specified and directed.
13S&F of submersible water lifting pump heavy duty suitable for desert cooler of capacity 4000/5000 cfm, 230 Volts 50 Hz Single Phase, including suitable size PVC three way distributor and PVC pipe of suitable size with elbow and bends including taking down old unserviceable water pump complete all as specified and directed.
14M&L for Aluminium heavy duty Fan blade with bush powder coated for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed.
15M&L for PVC heavy duty Fan blade with bush for fan motor of desert cooler 20 inch sweep including taking down old unserviceable fan blade complete all as specified and directed.
16M&L for cast Iron ring of cooler Fan motor Leg set (RH & LH) with clamps suitable for desert cooler complete with nuts & bolts including taking down old unserviceable complete all as specified and directed.
17S&F of 15mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock fixed in repair complete all as specified and directed.
18M&L for water tank suitable for desert cooler of capacity 5000/4000 cum/hour, fabricated with 1.00 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness and apply one coat of red oxide primer including taking down old unserviceable complete all as specified and directed.
19M&L for preparation of old painted surface of capacity 40/80, 60/120 & 150/150 litre water cooler, externally and internally including compressor chamber, motor and applying one coat of synthetic enamel paint with applying one coat of synthetic enamel paint with spray machine complete all as specified and directed.
20M&L for removing condenser Fan Motor from water cooler of capacity 40/80, 60/120 & 150/150 litres and rewinding the same with super enameled copper winding wire same gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed
21M&L for Float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 140 grams including taking down existing complete all as specified and directed.
22M&L for 15mm bore water tap (Internal thread), cast copper alloy, chromium plated push type suitable for water cooler of any capacity fixed as in repair complete all as specified and directed.
23M&L for Thermostat suitable for water cooler of any capacity fixed in repair complete all as specified and directed.
24M&L for waste water adaptor PVC, 32mm size suitable for water cooler of any capacity fixed as in repair complete all as specified and directed.
25M&L for relay with Over Load Protector suitable for 40 to 150 liters cooling capacity water cooler complete all as specified and directed.
26S&F of PVC drain out pipe, heavy duty 32/40mm dia, wall thickness 2mm complete with fittings such as nipple, clips etc complete fixed to water coolers of any capacity fixed as in repair complete all as specified and directed.
27S&F of Galvanized steel water tubing medium grade of 15mm bore with & including all fittings complete, fixed to walls and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified and directed.
28S&F of New freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning including cutting and removing old unserviceable freezer unit of refrigerator capacity 165/170/175/300/310/510 litres of any make complete all as specified and directed by Engr-in-Charge.
29M&L for Thermostat suitable for refrigerator of capacity 165 to 180 liters fixed as in repair complete all as specified and directed by Engr-in-Charge.
30S&F of Compressor suitable for water cooler of capacity 40/80 litre/hour as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
31S&F of compressor suitable for water coolerof capacity 60/120 litre/hour as required including necessary connections andand testing fixed as in repair including taking down old unsv complete all as specified and directed by Engr-in-Charge.
32S&F of compressor suitable for water cooler of capacity 150/150 litre/hour as required including necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed by Engr-in-Charge.
33S&F of compressor suitable for Refrigertorof capacity 165/175/185 litre as requiredincluding necessary connections and testing fixed as in repair including takind down old unsv complete all as specified and directed by Engr-in-Charge.
34S&F of compressor suitable for Refrigertorof capacity 285/300/310 litre as requiredincluding necessary connections and testing fixed as in repair including takind down old unsv complete all as specified and directed by Engr-in-Charge.
35S&F of condensing coil suitable for water cooler of capacity 40/80, 60/120 & 150/150 litre fixed as in repair including taking down old unsv complete all as specified and directed by Engr-in-Charge.
36Supply only refrigerant gas R-290/R-22 for charging where required at site as per direction of Engineer-in-Charge
37Supply only refrigerant gas R-32/R-410a/R-134a/R-407c for charging complete all as specified and directed by Engr-in-Charge.
38Servicing of Deep freezer of capacity 265/320/492 ltrs of any make checking / testing all parts for its serviceability, oiling / greasing to condensed motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and directed by Engr-in-Charge.
39M&L for Preparation of external old painted surface of Deep freezer of capacity 405/492 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and directed.
40S&F of compressor suitable for Deep Freezer of capacity 300/320 litre/hour as requiredincluding necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
41S&F of compressor suitable for Deep Freezer of capacity 500 litre/hour as requiredincluding necessary connections and testing fixed as in repair including taking down old unsv complete all as specified and directed.
42S&F of condenser coil suitable for Deep freezer of capacity 325 Litres fixed as in repair including taking down old unsv complete all as specified and directed by Engr-in-Charge.
43Finding out the leakage with the pressure test of condenser or cooling coil of water cooler capacity 40/80, 60/120 & 150/150 litre cooling/storage and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/ soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed.
44Finding out the leakage with the pressure test of the condenser or cooling coil ofRerigerator of capacity 165/170/175/300/310 litres and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and directed.
45S&F of cooling coil suitable for Deep freezer of capacity 300/500 liters fixed as in repair including taking down old unsv complete all as specified and directed
46S&F of condenser coil assembly suitable for Split type Air Conditioner 1.5/2.0 TR fixed as in repair including taking down old unsv complete all as specified and directed.
47S&F of condenser coil Assembly 1.5/2.0 TR suitable for window type Air Conditioner fixed as in repair including taking down old unsv complete all as specified and directed.
48S&F of coil Evaporator Assembly suitable for 1.5/2.0 TRwindow type Air Conditioner fixed as in repair including taking down old unsv complete all as specified and directed.
49M&L for Condenser Motor (Outdoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR inverterAC fixed as in repair including taking down of old unsv motor complete all as specified.
50M&L for Condenser Motor (Outdoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TRnon inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
51M&L for Blower Motor (Indoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR non inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
52M&L for Blower Motor (Indoor unit motor) of split type Air Conditioner of Capacity 1.5/2.0 TR inverter type AC fixed as in repair including taking down of old unsv motor complete all as specified.
53M&L for swing motor suitable for split air conditioner of capacity 1.5/2.0 TR invertor and non invertor type fixed as in repair including taking down old unsv complete all as specified and directed.
54M&L for Condenser/evaporator motor for window Air Conditioner of Capacity 1.5/2.0 TR inverter and non inverter AC fixed as in repair including taking down of old unsv motor complete all as specified.
55Servicing of split type Air Conditioner of capacity 1.5/2.0 TR of any type or make by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins and checking / testing of all parts for its serviceability, and oiling/greasing of motors, replacing worn-out bushes of blower, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete unitincluding testing for smooth functioning complete all as specified and directed. Note : (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Sch "A" price schedule (ii)Any spare part of AC if found defective will be measured as supply and fix fixed in repairs under respective item of this Sch "A" price schedule.
56Servicing of window type Air Conditioner of capacity 1.5/2 TR of any type or make including cleaning of filter on front sideby removing dust, cleaning the condenser including fins, blower fan motor and checking/testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn-out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc. and reassembling of complete AC including testing for smooth functioning complete all as specified and directed. Note : (i) Refrigerant Gas required for topping up will be measured and paid separately as supply only under respective item of this Sch "A" price schedule (ii)Any spare part of AC if found defective will be measured as supply and fix fixed in repairs under respective item of this Sch "A" price schedule.
57M&L for remote control (Micro processor) unit suitable for split type Air Conditioner 1.5 / 2.0 TR capacity of make AMTREX complete with wires of remote fixed in repair complete all as specified and directed.
58Shifting of Split type Air Conditioner 1.5/2.0 TR from one side to another by completely removing it from the existing place wihout any damage,and shifting it to new site including gas charging to required level comissioning and testing complete all as specified and directed.
59Shifting of Window type AC 1.5/2.0 TR from one site to another by completely removing it from the existing place wihout any damage, and shifting it to new site making necessary cuttung in the wall making it good, including gas charging to required level comissioning and testing complete all as specified and directed.
60M&L for suction lines copper pipes of suitable size as per site requirement fixed as in repair complete all as specified and directed.
61M&L for discharge lines copper pipes of suitable size as per site requirement fixed as in repair complete all as specified and directed.
62M&L for sleeve foam Protection suitable for Split type Air Conditioner 1.5/2.0 TR for both suction and discharge line fixed as in repair complete all as specified and directed.
63M&L for factory made PVC drain pipe suitable for Split type Air Conditioner 1.5/2.0 TR with coupler Joint fixed in repair complete all as specified and directed.
64M&L for removing the condenser fan motor from split type Air Conditioner of capacity 1.5/2.0 TR, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with new washer nuts & bolts complete all as specified and directed.
65M&L for circuit kit of window type Air Conditioner complete with lugs, thimble and selector switch fixed as in repair complete all as specified and directed.
66M&L for running capacitor, 55+2.5/6 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed.
67M&L for running capacitor, 45+2.5/4 MFD and one point for blower motor suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed.
68M&L for starting capacitor 2.50 MFD suitable for Air Conditioner of capacity 1.5/2.0 TR fixed as in repair complete all as specified and directed.
69M&L for aluminium/PVC fan blade suitable for condenser/blower of window/Split type Air Conditioner of any capacity of any type or make fixed as in repair complete all as specified and directed.
70M&L for PVC fan blade suitable for condenser of split type Air Conditioner of any capacity of any type (Invertor or non invertor type) or make fixed as in repair complete all as specified and directed.
71S&F in replacement of complete condenser unit (outdoor unit) 1.5TR including taking down old unsvcomplete all as specified and directed.
72M&L for starting relay only suitable for window/split type Air Conditioner 1.5/2.0 TR capacity of any type or make fixed as in repair complete all as specified and directed.
73M&L for over load protector only suitable for window/split type Air Conditioner 1.5/2.0 TR capacities of any type ormake fixed as in repair complete all as specified and directed.
74Supply, installation and testing of rotary compressor sealed unit for window type Air Conditioner of capacity 1.5/2.0 TRincluding testing for smooth functioning including taking down old unserviceable compressor complete all as specified and directed.
75Supply & installation of rotary compressor sealed unit for split type Air Conditioner of capacity 1.5/2.0 TR, (non invertor type) including testing for smooth functioning including taking down old unserviceable compressor complete all as specified and directed.
76Supply & installation of rotary compressor sealed unit for split type Air Conditioner of capacity 1.5/2.0 TR, (invertor type)including testing for smooth functioning including taking down old unserviceable compressor complete all as specified and directed.
77Supply and fixing in replacement of complete evaporator unit (indoor unit) 1.5TR including taking down old unsvcomplete all as specified and directed.
78M&L for thermostat suitable for window/split type Air Conditioner 1.5/2.0 TR capacity fixed as in repair complete all as specified and directed.
79M&L for cooling fan motor of capacity 1/30 HP or 1/20 HP from split type Air Conditioner, rewinding the same with supper enamelled copper winding wire of existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush andside rubber ring and removing and re-fixing in original position complete including testing complete all as specified and directed.
80Removing unserviceable window/split type Air Conditioner checking its leakage by filling of N2 gas, brazingand completely arresting its leakage, gas charging and testing complete all as specified and directed. Note : Gas charging shall be measured and paid separately.
81M&L for cooling coil suitable for window/split type Air Conditioner of capacity 1.5/2.0 TR including checking its leakage, brazingand completely arresting its leakage, gas charging and testing of any type or make fixed in repair complete all as specified and directed.
82M&L for wiring from indoor unit to outdoor unit of size 2.50 sqmm PVC insulated multistranded FRLS three core round cable including fixing of thimbles for fixing in compressor terminals for split type Air Conditioner 1.5/2.0 TR capacity inclduing taking down old unserviceable complete all as specified and directed.
83Contactor 16 Amp, suitable for split/window type Air Conditioner upto 2.0TR fixed as in repair complete all as specified and directed.
84Contactor 6 to 12 Amp,suitable for split/window type Air Conditioner upto 1.5 TR fixed as in repair complete all as specified and directed.
85Over load relay 3 Pole, 5 to 16 Amps suitable for split/windwo type Air Conditioner upto 2.0 TR fixed as in repair complete all as specified and directed.
86Universal Cordless Remote For any type of window/Split type Air Conditioner 1.5/2.0 TR fixed as in repair complete all as specified and directed.
87S&F of voltage stabilizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 130 V to 300 V with output voltage stabilized at 230V + 2.5% and of capacity 5.0 KVA complete all as specified and directed.
88S&F of PCB Plate for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (non invertor type) any type of Make fixed as in repair complete all as specified and directed.
89M&L for repair of PCB Plate for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (non invertor type) any type of Make fixed as in repair complete all as specified and directed.
90S&F of PCB Plate complete set for indoor and outdoor unit for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (invertor type) any type of Make fixed as in repair complete all as specified and directed.
91M&L for repair of PCB Plate for electronic control suitable for Split type Air Conditioner of 1.5/2.0 TR capacity (invertor type) any type of Make fixed as in repair complete all as specified and directed.
92S&F in replacement of complete condenser unit of cold storage of capacity 4 TR including testing and taking down old unsv unit complete all as specified and directed. Note : Old u/s unit shall be deposited to MES store yard.
93M&L Metal claid Top Plug and socket of Capacity 20 Amp 240 volt (ISI Marked) fixed as in repair complete all as specified and directed.
94M&L for Power socket 15 Amp suitable for metal clad box, ISI Marked including taking down old unserviceable complete all as specified and directed.
95M&L for Power plug top, ISI Marked including taking down old unserviceable complete all as specified and directed.
96S&F of factory made bracket with powder coated, fixed on wall with necessary grouting MS nut, bolt and washer or fastener as per site requirement for installation of outdoor unit of 1.5/2.0 TR split AC and making good disturbed surfaces, including taking down of old u/s bracket complete all as specified and directed.
97M&L for capillary of size 31, 36, 40, 50 & 80 No including taking down old unsv complete all as specified and directed
98M&L for suction line brass valve suitable for split air conditioner of capacity 1.5/2.0 TR complete all as specified and directed.
99M&L for discharge line brass valve suitable for split air conditioner of capacity 1.5/2.0 TR complete all as specified and directed.
100M&L for PTFE Thread Seal Tape 12mmx10m complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy