Tender For Repair Replacement Of Internal Wiring Ceiling Exhaust Fan Welcome Maintenance Replacement Of Modular Fitting And Fixture And Other Allied Works At Rashi Area Building At Navy Nagar Colaba Mumbai, mumbai-Maharashtra

Military Engineer Services-MES has published Tender For Repair Replacement Of Internal Wiring Ceiling Exhaust Fan Welcome Maintenance Replacement Of Modular Fitting And Fixture And Other Allied Works At Rashi Area Building At Navy Nagar Colaba Mumbai. Submission Date for this Tender is 27-05-2024. Electrification Work Tenders in mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43318247
Tender For Repair Replacement Of Internal Wiring Ceiling Exhaust Fan Welcome Maintenance Replacement Of Modular Fitting And Fixture And Other Allied Works At Rashi Area Building At Navy Nagar Colaba Mumbai
Open Tender
Indian
Maharashtra
mumbai
27-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Replacement Of Internal Wiring Ceiling Exhaust Fan Welcome Maintenance Replacement Of Modular Fitting And Fixture And Other Allied Works At Rashi Area Building At Navy Nagar Colaba Mumbai

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
82e3927d-87e1-4f7a-8cd1-3663f1d076a9.html Tender Notice 0 KB
8367TENDERDOCUMENTS.pdf Tender Document 0 KB
BOQ_730678.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR/REPLACEMENT OF INTERNAL WIRING, CEILING/EXHAUST FAN, WELCOME MAINTENANCE, REPLACEMENT OF MODULAR FITTING AND FIXTURE AND OTHER ALLIED WORKS AT RASHI AREA BUILDING AT NAVY NAGAR COLABA MUMBAI
Sl. No. Item Description
1Taking down carefully copper/ aluminium point wiring i.e. light, fan, socket or power/pointscomplete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
2M & L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE :Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm and quoted rate is included for this aspect.
3One light/Exhaust/Ceilingfan point controlled by one switch.
4One 3 pin switch socket combination 5 Amps on the same board with other switches.
5One 3 pin switch socket combination 5 Amps, independent.
6One bell point controlled by one push button
7All as per item No 2.00above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
8S & F modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
9S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
10S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make- Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
11S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make- Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
12S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm
13S & F modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
14S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
15S & FModular Socket6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
16S & F in replacement with Socket6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
17S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
18S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
19S & F in replacement with modular electric bell ding dong, AC, 230V single pole. Make:Crabtree/Anchor/Legrand
20S & F modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
21S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
22Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed.Make : Crompton/Bajaj/Wipro.
23Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
24Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC Gangbox, screwless, with silver border of 8 module for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Rider)/Legrand(Britzy)
25All as per Item No- 20.00 above but of modular PVC Gangbox, 6 module.
26All as per Item No- 20.00 above but of modular PVC Gangbox, 3 module.
27All as per Item No- 20.00 above but of modular PVC Gangbox, 2 module.
28All as per Item No- 20.00 above but of modular PVC Gangbox, 1 module.
29S&F modular white cover plate with frame, 8 module.
30S&F modular white cover plate with frame, 6 module.
31S&F modular white cover plate with frame, 3 module.
32S&F modular white cover plate with frame, 2 module.
33S&F modular white cover plate with frame, 1 module.
34Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including connection with ceiling rose.
35Taking down unserviceable FTL/batten fittings with supply and fix LED integrated batten of 10 Watt 2ft LED give minimum output lumen 1150 lm, efficiency >110, CCT 4000/6500K, CRI >80, power factor >0.9, operating temperature 45 degree celcious, THD <20% of housing aluminium extrusion with LED dimension 603mmx22mmx36mm upto 50% energy saving.
36Taking out any type of fitting bulkhead/FTL and S&F 10 watt linear LED batten, 2 feet, aluminium extruded channel, powder coated with diffuser for glare free light, inbult motion sensor prewired with 25% dimmer illuminiuos in ideal time with all accessories including two nos of PVC box of size 75x75x20mm for mounting light fittings complete.
37S&F MCB DB SPN conforming to IP 43 - IK 09 with acrylic door,8 waycomplete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls.Make:-L&T/Legrand/Havells
38Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt "C" series complete all as specified. Make:-L&T/Legrand/Havells
39Taking out Old U/S and S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt"C" series complete all as specified. Make:-L&T/Legrand/Havells
40Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified. Make:- Crompton/Bajaj/Usha/Havells
41Taking out unserviceable exhaust Fan and deposit to MES Store, supply and replacement with exhaust fan, Steel body4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connecting with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified and directed. Make :- Havells/Crompton/Bajaj/Polycab/Usha.
42Taking out & Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etcand assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Rate of petty items to be replace shall be included in quoted rate.
43Taking out & Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etcand reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting complete and testing after refixing at site. Note: Rate of petty items to be replace shall be included in quoted rate.
44Taking down deteriorted louvers and supplying and fix new louvers fixed type made out of 1.6mm GI sheet with horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete by providing of fixing arrangement for louvers upto 5th floor of including rate all as specified and directed by Engr-in-Charge
45S & F cable PVC insulated, PVC sheathed, armoured, FRLS, 1100Vgrade, 2 core 6 sqmm stranded copper conductor electric cable laidon wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
46S&F in relplacement with new cable PVC insulated three core over all PVC sheathed 2.5 Sqmm stranded copper conductor cable for connecion from DB to connector junction box for power supply to security light fittings drawn in PVC conduit not less than 20mm including taking out old one all as directed.
47S & F junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one.
48S&F street light bracket bend to shape made as required of 40mm dia 1.0 mtr long GI pipe light grade fixed to pole/ Wall including M&L for fixing with the help of flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out oldU/S one all as specified and as directed.
49Taking out Old, U/s one Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
50Inspection / checking of serviceability for ceiling fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e "S" hook, split pin, cotter pins, rubber bush, cpacitor, SWR etc) servicing the fan completely after removing of old grease from bearing and hanging it to its same loaction after complete assurence of any defects as specified inspecting fan for proper working, connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 all as specified and as directed by Engr-in-charge. Note (a) Complaint pertains to unserviceable Ceiling fan/Exhaust Fan/Energy Meter as given by the Engr-in-Chargeshall be attended within 48hrs from the day of complaint assigned to the representative of the firm as directed by Engr-in-Charge upto the satisfactory level and on failing which the penality shall be imposed @ Rs 250/- per day per item of Schedule (BOQ) (b) The Contractor or the accredited representative of the firm shall report to the JE concerned at the E/M Complaint Cell i.e Sub Station No -07 and RS-1 Colaba resp for receiving the complaints at 0900 to 1000hrs daily excluding Sunday and Holiday.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail