Tender For Repair / Maintenance Of Internal Electric Infrastructure, Led Energy Efficient Submain Wiring With Other Allied Works Of Water Supply Installations, Ro Plant Installations, manauri-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Internal Electric Infrastructure, Led Energy Efficient Submain Wiring With Other Allied Works Of Water Supply Installations, Ro Plant Installations. Submission Date for this Tender is 28-05-2024. Electrification Work Tenders in manauri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43318135
Tender For Repair / Maintenance Of Internal Electric Infrastructure, Led Energy Efficient Submain Wiring With Other Allied Works Of Water Supply Installations, Ro Plant Installations
Open Tender
Indian
Uttar Pradesh
manauri
28-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair / Maintenance Of Internal Electric Infrastructure, Led Energy Efficient Submain Wiring With Other Allied Works Of Water Supply Installations, Ro Plant Installations

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.0 /-
Tender Value
INR 14.50 Lakhs /-

Attachment

FileName File Description File Size
76f4f75c-0723-4724-a158-b3623816f5db.html Tender Notice 0 KB
BOQ_730556.xls Tender Document 0 KB
ListofMakes.pdf Tender Document 0 KB
PS.pdf Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR / MAINT OF INTERNAL ELECTRIC INFRASTRUCTURE, LED ENERGY EFFICIENT SUBMAIN WIRING WITH OTHER ALLIED WORKS OF WATER SUPPLY INSTALLATIONS, RO PLANT INSTALLATIONS UNDER AGE (I) AF MANAURI
Sl. No. Item Description
1Taking down carefully (aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete removing material to store of keeping in safe custody or for taking credit complete all as specified and directed.
2M&L for point wiring including concealed in surface of structure/ truss etc rigid non-metallic PVC conduit pipe medium grade, ISI marked heavy duty in size 20 MM diawith 1.5 Sqmm FRLS insulated unsheathed, multi stranded copper conductor cable, single core 1100 volt grade with flush cast iron/ pressed steel terminal boxes of suitable size for fixingsuch as switches, sockets and fan regulators etc with modular cover plate and fixing with brass screws/cup washer and including FRLS insulated & unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 Sqmm as continous earth wire complete including making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surfacefor the following complete all as specified and directed. Note:-Quoted rate shall be included cost of cheasesing, cutting, plastering and colouring etc to surface of wall / beam/ roof etc as site requiredmatchingwith existed surface and blank plate to be cover up to extra gap in mountingboard in given module /make / model etc.
3All as per item No. 2.00 above but one light point controlled by one way indepdentswitch complete all as specified and directed.
4All as per item No. 2.00 above but one fan controlled by one way indepdentswitch complete all as specified and directed.
5All as per item No. 2.00 above but one 3 pin 5 Amps socket out let point on same board controlled by one switch complete all as specified and directed.
6All as per item No. 2.00 above but one 3 pin 5 Amps socket out let point on independent board controlled by one switch complete all as specified and directed.
7All as per item No. 2.00 above but point wiring for 15 Amps socket using 2.5 Sqmm copper cable for phase and neutrl and 2.5 Sqmm as earth wire complete all as specified and directed.
8All as per item No. 2.00 above butpower point wiring using 4 Sqmm copper conductor cable FRLS insulated unsheathed and unsheathed copper conductor of 4 Sqmm as earth wire complete all as specified and directed. Note : All circuit shall be taken from seprate control DBs (connected with energy meter)to be connecting indivisual power load complete all as specified and directed.
9M&L for point wiring in PVC Casing & Caping single corePVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area), fixed on wall (concealed conduit wiring) on wall and on ceiling with GI saddles, GI screws, rowel plugs with all fittings including tee, junction boxesand drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and directed.
10All as per item No. 3.00 above but one light point or one fan point controlled by one switch with cable 1.5 sqmm size complete all as specified and directed.
11All as per item No. 3.00 above but one 3 pin 5 amps socket out let same board controlled by one switch complete all as specified and directed.
12All as per item No. 3.00 above but one 3 pin 6 amps socket outlet on independent board controlled by one switch complete all as specified and directed.
13S&F switch piano, flush type, single pole, one way 5 Amps complete all as specified and directed.
14S&F switch piano, flush type, single pole, one way 15 Amps complete all as specified and directed.
15S&Fpower unit single phase 220 volts 32 Amps socket and control switch ISI marked 4 module complete all as specified and directed.
16S&F switch socket combination 2 in 1, 5 pin 5 Amps flush type complete all as specified and directed.
17S&F switch socket combination 2 in 1, 5 pin 6/ 16 Amps flush type complete all as specified and directed.
18S&F stepped type electronic fan regulator flush type on existing phenolic laminated sheet etc as required complete all as specified and directed.
19S&Fin replacement LED recessed mounted 2x2 luminaire LED 36 Wlight fitting energy saving low glare high power mounting on twoNos PVC round/ square block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete all as specified and directed.
20S&F in replacement LED recessed mounted down 18 W light fitting energy saving low glare high power mounting on twoNos PVC round/ square block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete all as specified and directed.
21S&F in replacement LEDlight fitting with frame, driver etc in 20 W4 feet long white colour mounting on tow Nos of PVC round/ square block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete as directed. Make: Bajaj Cat No BCSLB 20 WH / Havells / Phillips / Crompton
22S&F in replacementLED tube light fitting with frame, driver etc in 10 W2 feet long white colour mounting on tow Nos of PVC round/ squire block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete as directed. Make: Bajaj Cat No BCSLB 10 WH / Havells / Phillips / Crompton
23M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly including taking down of old unserviceable sub main wiring with accessories complete all as specified and as directed. Note : (i) Two run of 06 sqmmwith one run of PVC conduit pipe shall be measured against one unit. (ii)Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface all as existed.
24All as per item No. 14.00 above but three run of 2 Core 4 Sqmm for phase, neutral and earth wire with suitable size concealed PVC conduit pipe complete all as specified and directed.
25S&F sheet metal enclosuredistribution board TPN, 4 poles, double door, 4 way with 200 Amps ratedbus bar vertcal type withMCCB 4 pole 100 Amps 415 volt thermal megnatic base operated as incomer including concealed in surface of wall and making all connection using gland, thembles in required size including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed. Note :Quoted rate shall be included cost of MCCB , cutting plastering, colouring to surface of wall to be concealedetcall site requiredmatching with existing surface.
26S&F sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
27S&F sheet metal enclosure for MCB distribution board SPN, double door, 4 way with 200 Amp rated bus bar 230 Volts including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
28S&F in replacement MCB, SPN, 2 pole 220 volts, 40 Amps, "C" Curve 10 kA complete all as specified and directed.
29S&F in replacementMCB, single pole 215 volts, 10-32 Amps, "C" Curve 10 kA complete all as specified and directed.
30S&F inreplacement LED bulb 12 W complete all as specified and directed.
31S&F in replacement of 100 watt flood light fitting for replacingwith High mast tower / pole in any length / specification, energy saving IP 65 protection, required nut bolt washer etcincluding making electric connection using three core copper flexible cable drawn through in PVC flexible conduit complete all as specified and directed. Note: Quoted rate shall be included cost to take down / up, replacing of inter connection cable etc and other required site work.
32S&F in replacement of 60 watt LED street light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection, white cool, Raptor Neo, metal, input Voltage 220 V includingmaking connection complete from fitting to pole/terminal box complete all as specified and directed.
33S&F in replacement 10 WLED bulk head light fittings including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings complete all as specified and directed.
34M&L for earthing (in replacement) complete with galvanized steel earth plate electrode of size 60 CM x 60 CM x 6 MMthick buried directly in ground (earth pit not less than2.25 m deep below the ground level) with top edge of earth plate not less than 1.50 m below normal ground level connected to galvanizedearth leadstrip 32 x 6 mm size by means ofnut, bolts & check nuts and washers of galvanized iron or steel connected to Earthing test point complete all as specified or indicated, including earthing pit with PCC 1 : 3 : 6 type C1 (using 20 mm graded crushed stone aggregate) & RCC cover slab 40 mm thick as in RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8 MM dia TMT bars @ 150, mm centre to centre both way with two Nos lifting handle, GI pipe 20 mm dia "light grade" with funnel and wire mesh for watering and 40 mm dia "light grade" GI pipe for GI earth strip 32 x 6 mm protection etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing on completion complete all as specified and directed.
35S&F in replacement MCCB, 3 pole, TPN 63 Amp rating having breaking capacity of 16 kA at 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand / Siemens / L&T / Havells
36All as per item No. 26.00 above but 4 pole 415 Amps 125 Amps capacity complete all as specified and directed. Make: Legrand / Siemens / L&T / Havells
37S&F in replacement MCCB, 4 pole, 250 Amp rating having breaking capacity of 36 KA at 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand / Siemens / L&T / Havells
38Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified and directed.
39Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete all as specified and directed.
40Removing excavated material (soil) out side MD land at contractor"s own arrangement complete all as specified and directed.
41Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioningas in trenches 8cm depth below cable and 15cm above cable andpunned to 10cm depthcomplete all as specified and directed. Note :- Punned thickness shall be considered for measurement purpose.
42M&L brick, sub class "B" bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed
43Labour only for cutting/boring to plinth protection/hard standing/road etc in suitable depth and corssing ofGI pipe of size 80 MM bore so that XLPE under ground cable can bepassed andgiving mechanical protection to cable complete all as specified and directed. Note:- Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existing specification and GI pipe shall be measured and paid seperately under respective itmes.
44Supply, laid in trench /fixedin replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area4 core x 25 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
45All as per item No 35.00 above but size of cable 3.5 core x 50 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
46All as per item No 35.00abvoe but size ofcable 3.5 core x 120 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
47S&F in replacement 40 mm dia GI tubing "light grade" with fixing acessories laid in trenches or on wall or pole with clamp complete all as specified & directed. Make: Tata / Jindal / Swastik
48All as per item No. 38.00 above of but size of 50 MM dia complete all as specified & directed.
49All as per item No. 38.00abovebut of size of 80 MMdia complete all as specified & directed.
50M&L painting to steel prepared surfaces of any width or girth not otherwise described by using synthetic enamel paint in two coats (one as finishing coat) over one coat of red oxide zinc chrome primer on surface of steel structure / girder / angle frame / wire mesh fencing (both side) / installation board / gate etc in any description at E/M installation using paint spray gun on specified working pressure including sign making / marking with using different colour in given size of letter etc complete all as specified and directed. Note: Paint colour & shade including writing marking of letters etc shall be deemed included in quoted unit rate and the same shall be approved by Engr-in-Charge. Make: Asian / Berger / Dulex
51M&L Painting to existing two/three steel pole structure of 11 m height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above planting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 m height of pole complete all as specified and as directed. Note: Cutting of bushes & tree branches upto 3 m height of pole shall be deemed included in quoted unit rate.
52All as per item No. 42.00 above but steel tubular pole in 9 m long complete all as specified & directed.
53S&F in replacement Air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified & directed.
54S&F in replacement Aviation Obstruction Light yellow painted die cast aluminium alloy housing built in 75VA step up transformer, heat resistant, clear thick glass and accessories with all making connection complete all as specified & directed.
55S&F in replacement to shock proof, fire retardant rust proof, out door pole kiosk box of size 295 x195 x100 MM made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 aluminium strip of 60 Amp rating fitted on DMC unbrakable insulator with MCB SPN 40 Amp including fixing arrangement as clamps made out by GI strip in size 32 x 6 MM andnut bolts washer with painting in two coat syenthic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
56S&F in replacement three core copper flexible wire, PVC insulatedsheathed copper conductor muiti strandard in 1.5 Sqmm size for making inter connection of street/ road light fittings from control box to fittings drawn through in steel tubular pole including lugs / thimbles in required size etc complete all as specified & directed.
57S&F in replacement three pole power contactor type ML-6 suitable for AC1 rating 125 Amp range, 240 voltconfirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-3, 2 NO+ 2 NC including making connection complete all as specified & directed. Make: L&TModel-SS90921 / Siemens / Schneider / C&S / MDS
58S&F in replacement three pole power contactor type MNX-32 suitable for AC1 rating 55 Amp, AC3 rating 32 Amp, range, 240 voltconfirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-2, including making connection complete all as specified & directed. Make: L&TModel-CS94111 / Siemens / Schneider / C&S / MDS
59S&F in replacement of off load change over switch in sheet metal enclosure 4 poles, 250 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as specified & directed. Make: L&T / Havells / Siemens
60S&F on load change over, 160 Amp, 415 volt in sheet steel enclosure type Fr2 (4P), manual, suitable for DIN fuseiling and providing electrical connection with suitable size copper lugs and wires, complete making all electrical connections including taking down old unserviceable change over switch complete all as specified & directed. Make: L&T Cat Part No. CO21600OSOO / Siemens / Legrand / ABB
61Supply, erecting and fixing in replacement steel tubular swaged pole 9.00 mtr long type 410 SP-31 confirming to IS - 2713 Prt I to III 1980 with and including cast iron base plate, finial taper plug, Nuts, bolts and washers etc and fixed into plain cement concrete foundation duly painted with two coats of aluminium paint over coat of red oxide primer including preparation of surfaces and making strip 150 mm wide up to 1.50 Mtr (above PCC coping) by black, yellow, paint in alternate layer and pole numbers complete all as specified & directed. Note : Earth work, cement concrete will be incuded in quoted unit rate.
62S&F in replacement fully cast aluminium body finished with polyurethane paint (with prior treatment) LEDpost top lantern 40watt with acrylic window cover total length 762 mm & Max.Breath 431 mmwith spigot entry 78mm with all fixing arrangements complete all as specified & directed. Make: Bajaj / Mepro / Havells / Crompton
63Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix "B" to Particular specifications as approved by AGE (I) AF manauri
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail