Tender For Provision Of Walk In Cooler Hospital Kitchen At Aicts And Special Repair To Replacement Of Distribution Board Sub- Main Wiring And Other Misc Item At Pcda O Under Age E / M I Ii Of Ge South Pune, pune-Maharashtra

Military Engineer Services-MES has published Tender For Provision Of Walk In Cooler Hospital Kitchen At Aicts And Special Repair To Replacement Of Distribution Board Sub- Main Wiring And Other Misc Item At Pcda O Under Age E / M I Ii Of Ge South Pune. Submission Date for this Tender is 25-05-2024. Electrification Work Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

43317781
Tender For Provision Of Walk In Cooler Hospital Kitchen At Aicts And Special Repair To Replacement Of Distribution Board Sub- Main Wiring And Other Misc Item At Pcda O Under Age E / M I Ii Of Ge South Pune
Open Tender
Indian
Maharashtra
pune
25-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Provision Of Walk In Cooler Hospital Kitchen At Aicts And Special Repair To Replacement Of Distribution Board Sub- Main Wiring And Other Misc Item At Pcda O Under Age E / M I Ii Of Ge South Pune

Key Value

Document Fees
INR 500 /-
EMD
INR 85000.0 /-
Tender Value
INR 42.50 Lakhs /-

Attachment

FileName File Description File Size
c93328fd-0c2c-4d14-9700-3cb75527b039.html Tender Notice 0 KB
8557TEDNERDOCUMENTS.pdf Tender Document 0 KB
BOQ_730381.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:PROVN OF WALK IN COOLER HOSPITAL KITCHEN AT AICTS AND SPECIAL REPAIR TO REPLACEMENT OF DISTRIBUTION BOARD, SUB-MAIN WIRING AND OTHER MISC ITEM AT PCDA(O) UNDER AGE E/M-I & II OF GE SOUTH PUNE
Sl. No. Item Description
1Supply, installation, testing and commissioning of Walk in cold room size of walk in cooler 11 feet (L)x 18 feet (Width) x 9 feet (Height) with and including comprising of the followings provisions:- (i) Thickness of insulation 60 mm, PPGI on outside & on inside including Pre-Fabricated modular PUF panels. (ii) Type of insulation for floor- 50 mm Puff slabs. (iii) Door size : PUF-flush in type hinged door with 34"x78" clear opening including with accessories, Anti-condensation door heater, pad lock system, posi seal closure, human safety release with knob etc complete. (iv) Max ambient condition : 40 degree C. (v) Product: Fresh Ration type, (vi) Product incoming temp : 20 to 25 degree C. (vii) Temp required inside the room : 2 to 8 degree. (viii) Refrigeration unit model shall be - BSL Evaporator unitSS # 2Nos (1W + 1S)RUAH-02014 KP-I& BSL Condenser Unit # 2Nos (1W + 1S) RUAHOS2014, Refrigeration cap 20000 BTU/Hr, 415/3/50Hz,split type air cooled, refrigerant : R404 ECO FRIENDLY REFRIGERANT , Make:- Bluestar / Carrier / Voltas / Godrej
2(ix) Digital temp indicator cum controller and internal lighting complete as per manufacturer design. (x) Copper tubing of suitable size with insulation from indoor to outdoor unit drain pipe complete. (xi) PVC copper cable of suitable size from indoor to outdoor cable and from nearest connections point. Note:-(a) The cost of making necessary opening in bricks / stone masonry wall including making good the disturbed surfaces to math with existing surrounding shall be deemed to be included in unit quoted rates. (b) The outdoor unit shall be fixed on wall with and including suitable size of brackets and the cost of these provisions shall be deemed to be included in unit quoted rates.
3M&L for earthing complete with galvanised steel earth plate electrode including necessaryexcavation and earth work in any type of soil with galvanized steelearth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly inground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground levelconnected to with and including earth lead of GI strip of 25x4mm size up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth strip protected by galvanised iron 40 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concretepit shall be PCC 1:3:6 type C-1,40 mm thick precast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing strip shall be encased in and including 40mm nominal bore GI "light grade" tubing with all fittings from earth plate up to panel shall beprovided & charcoal / saltfunnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m GI pipe for protection of GI earth strip for each earthing.
4M&L for 25x4mm size galvanised iron strip as in earth continuity or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing, complete all as specified and directed.
5S&F MCB DB, TPN 4 way, IP-43 protection, double door, with bus bar 415 V and concealed / fixed on wall / board as required including all cutting holes in or through walls, making good the disturbed surfaces of walls, ceiling etc including providing two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing, complete all as specified and directed.
6S&F in replacement MCB DB, SPN 12 way, IP-43 protection, double door, with bus bar 240 V and concealed / fixed on wall / board as required including all cutting holes in or through walls, making good the disturbed surfaces of walls, ceiling etc including providing two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing, complete all as specified and directed.
7S&F in replacement IP-43, protection metal door Vertical TPN-DB rated bus bar, pan assembly etc. with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules with provision to mount 100 Amps MCCB 4 pole as incomer and SP/TP MCB as outgoing and concealed / fixed on wall / board as required including all cutting holes in or through walls, making good the disturbed surfaces of walls, ceiling etc including providing two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing including taking down of old unserviceable DB, complete all as specified and directed.
8S&F in replacement MCB, TPN, 63 Amps, 10 KA, 415 V, "C" series complete all as specified and as directed.
9S&F in replacement MCB, TPN, 40 Amps, 10 KA, 415 V, "C" series complete all as specified and as directed.
10S&F in replacement MCB, TP, 40 Amps, 10 KA, 240 V, "C" series complete all as specified and as directed.
11S&F in replacement MCB, SPN, 63 Amps, 10 KA, 240 V, "C" series complete all as specified and as directed.
12S&F in replacement MCCB, 4 pole, 100 Amps, 16 KA, 415 V, with thermal release complete all as specified and as directed.
13S&F in replacement MCB, TP, 32 Amps, 10 KA, 415 V, "C" series complete all as specified and as directed.
14S&F in replacement MCB, SP, 6-40 Amps, 10 KA, 240 V, "C" series complete all as specified and as directed.
15M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of sizewith 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirmingto IS: 694-1990 with and including continuous earth wire of size 1x10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including ISI maked PVC casing caping of white/ ivory colour and its accessariesISI marked of suitable size and connected to common earth dolly, including making good the disturbed surfaces of walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note:-One meter of PVC casing caping along with 2x4 sq mm cable and 1x4 sq mm earth shall be measured as one unit length.
16Dismantling and taking out all electric connection, cable & accessories etc and remove all items and keeping in safe custody and re-fixing of same after installation of walk in cooler complete all as directed by Engr-in-charge.
17Dismanling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to MES store yard and rubbish off the premises, complete all as specified and directed.
18M & L for machine cut kota stone slab flooring of 20-25mm thick, laid& joint with neat cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding & polishing (mirror finished) and laid over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed. Note:- The size of kota stone slab not less than 550mmx550mm (cut size except the location where balanced.)
19All as per item No.17 herein before but as on vertical surfaces such as dado / skirting, steps etc. over and including 10mm thick rendering in CM (1:3) complete all as specified and directed
20M&L for 40 mm thick PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
21M&L for earthing complete with galvanised steel earth plate electrode including necessaryexcavation and earth work in any type of soil with galvanized steelearth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly inground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground levelconnected to with and including 4mm dia GI wire as in earth lead up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I (2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of 4mm dia GI wire protected by galvanised iron 15 mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concretepit shall be PCC 1:3:6 type C-1,40 mm thick precast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI "light grade" tubing with all fittings from earth plate up to panel shall beprovided & charcoal / saltfunnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m GI wire & pipe for protection of GI earth wire for each earthing.
22S&F heavy duty stainless steel shelving rack in 304 grade of Size - 2100mm height, 2250mm length, 750mm depth, having 5 shelves made from 30mm x 5mm stainless steel angle, 1mm stainless steel sheet on each shelf with support pipe complete all as directed and drawing provided by Engr-in-Charge.
23S&F heavy duty stainless steel shelving rack in 304 grade of Size - 2100mm height, 1650mm length, 900mm depth, having 5 shelves made from 30mm x 5mm stainless steel angle, 1mm stainless steel sheet on each shelf with support pipe complete all as directed and drawing provided by Engr-in-Charge.
24M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size04 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH-confirmingto IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and includingnon metallic rigid heavy duty PVC conduit of white /ivory colour including with accessories, ISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of walls including making good to walls etc including two coats of white / colour washing / distempering (as applicable) on the disturbed surfaces to match the existing complete including taking down of old unserviceable sub main wiring complete all as specified & directed. Note:- Two runs of 4.0 sqmm cable, one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit length.
25M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH-confirmingto IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and includingnon metallic rigid heavy duty PVC conduit of white /ivory colour including with accessories, ISI marked of suitable size concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of walls including making good to walls etc including two coats of white / colour washing / distempering (as applicable) on the disturbed surfaces to match the existing complete including taking down of old unserviceable sub main wiring complete all as specified & directed. Note:- Two runs of 6.0 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit length.
26M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLSH cable with stranded copper conductor of size10 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLSH flexible wiring cable confirmingto IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, two core, PVC insulated, copper conductor cable drawing into and includingnon metallic rigid heavy duty PVC conduit of white /ivory colour including with accessories, ISI marked of suitable size, concealed in wall etcand connected to common earth dolly including all cutting / chases etc in any type of walls including making good to walls etc including two coats of white / colour washing / distempering (as applicable) on the disturbed surfaces to match the existing complete including taking down of old unserviceable sub main wiring complete all as specified & directed. Note:- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of PVC conduit will be measured as one unit length.