Tender For Servicing B Checks To Captive/ Stand By Generators And Repairs To Corroded Parts Of Dg Sets And Connected Pumps And Certain Electrical Works At Mes Power House, Nsry, Hq Anc, Navy Park, Jarawa Under Ge Haddo Port Blair, blair-Andaman And Nicobar Islands

Military Engineer Services-MES has published Tender For Servicing B Checks To Captive/ Stand By Generators And Repairs To Corroded Parts Of Dg Sets And Connected Pumps And Certain Electrical Works At Mes Power House, Nsry, Hq Anc, Navy Park, Jarawa Under Ge Haddo Port Blair. Submission Date for this Tender is 25-05-2024. Electrical Maintenance Tenders in blair Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.




Tender Notice

43317546
Tender For Servicing B Checks To Captive/ Stand By Generators And Repairs To Corroded Parts Of Dg Sets And Connected Pumps And Certain Electrical Works At Mes Power House, Nsry, Hq Anc, Navy Park, Jarawa Under Ge Haddo Port Blair
Open Tender
Indian
Andaman And Nicobar Islands
blair
25-05-2024

Tender Details

Servicing B Checks To Captive / Stand By Generators And Repairs To Corroded Parts Of Dg Sets And Connected Pumps And Certain Electrical Works At Mes Power House, Nsry, Hq Anc, Navy Park, Jarawa Under Ge Haddo Port Blair

Key Value

Document Fees
INR 500 /-
EMD
INR 92000.0 /-
Tender Value
INR 46 Lakhs /-

BOQ Items

NAME OF WORK : SERVICING/ "B" CHECKS TO CAPTIVE/ STAND BY GENERATORS AND REPAIRS TO CORRODED PARTS OF DG SETS AND CONNECTED PUMPS AND CERTAIN ELECTRICAL WORKS AT MES POWER HOUSE, NSRY, HQ ANC, NAVY PARK, JARAWA UNDER GE HADDO PORT BLAIR.
Sl. No. Item Description
1S&F Exhaust Bellow of 170mm dia size as per existing make and model as per site requirementfor 1250/2000 KVA DG set including necessary nuts, bolts and washers including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
2S&F Exhaust Bellow of 75mm dia size as per existing make and model as per site requirementfor 1250/2000 KVA DG set including necessary nuts, bolts and washers including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
3M&L for Laser alignment of alternator with engine of 1250/2000KVA DG set including replacement of rubber coupling complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
4S&F Drive end bearing of existing make and model as per site requirement for 1250/2000 KVA DG set including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
5S&F Non drive end bearing of existing make and model as per site requirementfor 1250/2000 KVA DG set including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
6S&F Exhaust Bellow of 475mm dia size as per existing make and model as per site requirementfor 1250/2000 KVA DG set including necessary nuts, bolts and washers including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
7Takingdown unserviceable self-starter 12 volts for DG set from engine, dismantling and opening of stater and armature,replace the wornout carbon brush,pinion,ignition coil bearing,bushing, including servicing,varnishing of stater after repairingassembling,refixed to same position complete all as specified and directed.
8Cleaning the radiator intercooler of1250 to 2000KVA DG set by checking and removing the deposited dust, oil welt and carbon deposits etc. with wire brushes, cleaning agents etc. complete all as specified and as directed by Engineer-in-charge
9Cleaning the radiator intercooler of 400/250/160/125/ 100/ 82.5/ 62.5/ 40 KVA DG set by checking and removing the deposited dust, oil welt and carbon deposits etc. with wire brushes, cleaning agents etc. complete all as specified and as directed by Engineer-in-charge
10S&F new gun metal gate valve of 50mm dia bore [Class-II, 1.6 Mpa] with ISI mark and iron wheel head, screwed both ends to GI pipes,including taking down old unserviceable gate valve complete all as specified and as directed by Engineer-in-charge. [Make: Leader/ Bir/ Zoloto/ Lakshmi/ Shakti]
11S&F new gun metal gate valve of 25mm dia bore [Class-II, 1.6 Mpa] with ISI mark and iron wheel head, screwed both ends to GI pipes,including taking down old unserviceable gate valve complete all as specified and as directed by Engineer-in-charge. [Make: Leader/ Bir/ Zoloto/ Lakshmi/ Shakti]
12Takingdown unserviceable self-starter 24 volts for DG set from engine,dismantling and opening of stater and armature,replace the wornout carbon brush,pinion,ignition coil bearing,bushing, including servicing,varnishing of stater after repairingassembling,refixed to same position complete all as specified and directed.
13S&F rotating rectifier diode set (forward - 3 Nos & reverse - 3 Nos) along with surge arrestors suitable for 1250/2000 KVA Cummins DG set, fixing and connecting in the circuit, starting and testing on load complete all as specified and as directed by Engineer-in-charge.
14All as per Item No. 13 herein before but for 40KVA to 400KVA DG Sets
15S&F Belt V ribbed type to drive alternator from pulley as per existing maodel and make for 1250 to 2000KVA DG Set complete all as specified and as directed by Engineer-in-charge.
16S&F in repairs 3 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type ML 4for 30 HP pump setcomplete all as specified and as directed by Engineer-in-charge.make: L&T/Bharat cat hammer.
17S&F in repairs 3 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type ML 2for 10/5 HP pump setcomplete all as specified and as directed by Engineer-in-charge. Make: L&T/Bharat cat hammer.
18S&F in repairs 4 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type MCX 33for AMF panelcomplete all as specified and as directed by Engineer-in-charge. Make: L&T/Bharat cat hammer.
19S&F in repairs Electronic timer with auxiliary voltage of 110/240v, 50Hz for operation of 9-30 sec complete all as specified and as directed by Engineer-in-charge. [Make: L&T/ GE/ Siemens]
20M & L for supply and fixing Automatic Voltage Regulator Model AX - 02 suitable for 400/250/160/125 /100/ 82.5 /62.5/40KVA DG sets, starting and testing on load all as specified and directed. Make: Altex /Kirlosakr
21M&L for carrying out "B" check for 40 KVA DG set as per manufacturer"s recommendation including replacement of necessary spares and Filters such as Fuel filter, SLO Bypass filter and lub oil filter complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. Make of DG Set: Kirloskar/Cummins/Greaves. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, "O" rings etc.]
22All as per Item No. 21 herein before but for 62.5 KVA DG set
23All as per Item No. 21 herein before but for 82.5 KVA DG set
24All as per Item No. 21 herein before but for 100 KVA DG set
25All as per Item No. 21 herein before but for 125 KVA DG set
26All as per Item No. 21 herein before but for 160 KVA DG set
27All as per Item No. 21 herein before but for 250 KVA DG set
28All as per Item No. 21 herein before but for 400 KVA DG set
29All as per Item No. 21 herein before but for 10 KVA DG set
30M&L for carrying out "B" check for 1250 KVA DG set [Make: Cummins, Model: KTA-50 G3] as per manufacturer"s recommendation including replacement of necessary spares and filters such as Fuel filter-02 Nos [Part No. 3238493], SLO Bypass filters-02 Nos [Part No. 3879488] and Lub oil filters-04 Nos [Part No. 3310169] complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, "O" rings etc.]
31Supply only Engine oil 15w 40type:CH4 or CI4 as per requirement and manufacturer recommendation [Make: Servo/ Valvoline/ Castrol/Mobil]
32Supply only concentrated Engine coolant in 5 litre container [Make: K-Cool or as recommended by OEM]
33S&F battery terminal, brass heavy duty (two nos) complete suitable for fixing on battery poles with nuts and bolts complete including disconnecting and taking down unserviceable battery terminal all as specified and directed.
34S&F battery lead copper conductor single core 70sq.mm, 2 metre long (two nos) complete including soldering of copper lugs including disconnecting and taking down unserviceable battery lead complete all as specified and as directed by Engineer-in-charge.
35M&L for removing oil/ grease deposits, oil/ paint/ corrosion flakes and cleaning the external surface of 2000 KVA DG set of make: Cummins/perkins, using wire brushes, coarse cloth, cleaning agents etc. and applying two coats of heat retardant paint of approved tint by spray application complete including necessary T&P like spray gun, air compressor etc.complete all as specified and as directed by Engineer-in-charge.
36All as per Item No. 35 herein before but for 1250 KVA DG Set
37All as per Item No. 35 herein before but for 400 KVA DG Set
38All as per Item No.35 herein before but for 250 KVA DG set along with acoustic enclosure.
39All as per Item No.35 herein before but for 160 KVA DG set along with acoustic enclosure.
40All as per Item No.35 herein before but for 125 KVA DG set along with acoustic enclosure.
41All as per Item No. 35 herein before but for 100 KVA DG set along with acoustic enclosure.
42All as per Item No.35 herein before but for 63/82.5 KVA DG set along with acoustic enclosure.
43All as per Item No.35 herein before but for 10 to 40 KVA DG set along with acoustic enclosure / 44BHP Diesel driven pumpset.
44S&F in repairs 4 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type MCX 11for AMF panelcomplete all as specified and as directed by Engineer-in-charge. Make: L&T/Bharat cat hammer.
45M&L for replacement of turbo blower intake air filter set complete (Primary & Secondary filters) for1250KVADG set of of Make: Cummins, model: QSK-60-G4 complete all as per manufacturer"s recommendation.
46Dismantling and taking out old unserviceable burnt terminal blocks connectors from mounting base of 40KVA to 400KVA DG setAlternator inlet & outlet cables and supply & fixingfor Terminal blocks connector and re-connecting of same cables properly including providing of new lugs & alternator top cover farbrication all as specified .
47Dismantling of Fuel pump from 40to 125 KVA DG set/ 44BHP Diesel driven pumpset for Replacement of FIP Solenoid switch for fuel pump and re-connecting for the same fuel pump properly including all as specified .
48All as per Item No.47 herein before but for 160 to 400 KVA DG set
49Dismantling and taking out old unserviceable water pump for 40-125 KVA DG set and M & L for new water pump including all as specified .
50All as per Item No.49 herein before but for 160 to 400 KVA DG set
51Draininng up the fuel tank/Diesel tank in a separate empty barrels, disconnecting the fuel lines from the fuel filters and taking out the fuel tank and clearing internally andremove the accumulated slludge/Sediments and arresting leakages, reconnecting back all the removed fuel lines and mounting the diesel tank its orginal position, supply and replacing the drain plug suitable and including painting of external surfaces by using synthetic enamel paint of two coats over one coat of red oxide primertesting complete for 1250KVA to 2000 KVA DG Sets(3 to 4 tanks) capacity Diesel Tanks of DG sets.
52All as per Item No.51 herein before but for 400/250/160KVA DG Sets
53All as per Item No.51 herein before but for 63/82.5/100/125KVA DG Sets
54All as per Item No.51 herein before but for 40KVA DG Sets
55All as per Item No.51 herein before but for 10 KVA DG Sets
56Dismantling,dismounting and transportation of 40/63.5/82.5KVA DG set alternator assembly of existing Make of DG Set: Kirloskar/Cummins/Ashok Leylandfrom its foundation and rewinding of main stator with suitable gauge of F class enamelled winding wire of copper as per OEM recommendations,air drying,insulating varnish and becktrol red,heating insulation etc. and refixing/reassembling the alternator assembly to its foundation including connection,amputation,hot and cold checkups etc.inluding alignment and testing all as specified and directed by Engineer-in-Charge. Note: Rate includes necessary transportation to workshop and back.
57Dismantling,dismounting and transportation of 100/125/160KVA DG set alternator assembly of existing Make of DG Set: Kirloskar/Cummins/Ashok Leylandfrom its foundation and rewinding of main stator with suitable gauge of F class enamelled winding wire of copper as per OEM recommendations,air drying,insulating varnish and becktrol red,heating insulation etc. and refixing/reassembling the alternator assembly to its foundation including connection,amputation,hot and cold checkups etc.inluding alignment and testing all as specified and directed by Engineer-in-Charge. Note: Rate includes necessary transportation to workshop and back.
58Supply and connect and test lead acid battery heavy duty 12 volt 180 AH complete with initial charging complete all as specified. (Make : Exide/Amaron)
59All as per Item No. 58 herein before but for of capacity 12 V 160AH
60All as per Item No. 58 herein before but for of capacity 12 V 120AH
61Supply and fix against repairs SMPS/ Automatic battery charger 240 V input , 24 V / 10 - 15 Amps output with auto cut off and floating with selector switch and indicators, set of fuses complete all as spcified and directed by Engineer-in-charge.
62M&L for carrying out "B" check for 2000 KVA DG set [Make:Perkins, Model: 4016-61TRG2 as per manufacturer"s recommendation including replacement of necessary spares and filters such as Fuel filter-02 Nos and Lub oil filters-06 Nos complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, "O" rings etc.] (ii)"B" Check should be carried out by OEM/Captiva Energy solutions,Kolkata.
63Supply only premix coolant/ corrosion inhibitor suitable for 2000KVA Perkins DG set model no. 4016-61TRG2 as per manufacturer"s recommendation.
64M&L for replacement of turbo blower intake air filter set complete for 2000KVADG set of of Make: Perkins,model no. 4016-61TRG complete all as per manufacturer"s recommendation.
65Dismantling and taking down Engine of capacity 40-160 KVA of existing Make: Kirloskar/Cummins/Ashok Leyland/CG, any cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for Top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction and testing of efficiency of engine on completion of repair work complete all as directed. (worn out parts shall be measured and paid seperately)
66Supply only cylinder head by removing worn out valves, valve guide, valve seat etc of existing make and modelof 40-160 KVA DG Set complete all as specified and directed.
67Taking out crank shaft for existing make and model for 40-160 KVA DG Set carefully, taking to local market for turning, polishing,metal filling if necessary and refixing of the engine including replacement of main bearings and oil seal complete all asdirected.
68Supply only turbo charger core assembly for 40-160 KVA DG Setof existing make and model complete all as directed.
69Supply only coupling flexible for 40-160 KVA DG Setof existing make and model complete all as specified and directe
70Supply only lub oil cooler 40-160 KVA DG Set of existing make and model complete all as specified and directe
71Supply only radiator assembly including inlet and outlet pipe for 40-160 KVA DG Set of existing make and modelcomplete all as specified and directed
72Supply only alternator/dynamo 12 volt for 40-160 KVA DG Setof existing make and model complete all as specified and directed
73Supply only oil sealcomplete of existing make and model complete all as specified and directed
74Supply only Stop Solenoid for 40-160 KVA DG Setof existing make and model complete all as specified and directed
75Supply only piston for 40-160 KVA DG Setof existing make and model complete all as specified and directed
76Supply only piston rings for 40-160 KVA DG Setof existing make and model complete all as specified and directed
77Supply only gasket for 40-160 KVA DG Setof existing make and model complete all as specified and directed
78Supply only liner for 40-160 KVA DG Setof existing make and model complete all as specified and directed
79Supply only Sleeves for 40-160 KVA DG Set of existing make and model complete all as specified and directed
80M&L, Steel Tubes, Medium Grade, Galvanised laid in trenches or on walls/floor with necessary clamps of 50mm dia size with all fittings and fixtures such as bends, tees, elbows, reducers, unions, plugs & sockets etc., complete all as specified and directed.
81All as per item no.80 here-in-before but 25mm dia size.
82Disconnecting of the suction/delivery lines of the centrifugal/ monoblock pumpset connected to DG set Cooling tower/coil cooler/compressorincluding pulley, coupling connected to the motor and removing the pumpset from its location, opening up, carrying out complete overhauling of the pumpset and replacing defective/worn out parts, packing kit, greasing, re-assembling, placing back the pumpset in its original location and connecting back of suction/delivery lines, coupling, pulley, re-alignment and testing complete all as specified and as directed for 15/20/30 HP capacities of centrifugal/monoblock pumpsets of any make. NOTES: (i)Spares like bronze impeller, bearing, bush, bronze casing ring, gland plate of stuffing box shall be measured and paid separately under relevant items of this BOQ as SUPPLY ONLY. (ii) Old material obtained from replacement shall be contractor"s property as per Schedule of credit given in tender.
83All as per item no.82 here-in-before but for 5/7.5/10 HP capacity.
84Disconnecting/ dismantling 3 phase, 440 volts, 50 cycles electrical motor from the centrifugal/monoblock pumpset (electrically and mechanically) connected to DG set Cooling tower/coil cooler from its location and shifting to work shop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding of motor with appropriate gauge, weight and turns of super enamelled copper winding wire using proper Garware insulating paper, insulating with Class I varnish, and oven drying for requisite insulation values, reassembling the motor completely and bringing back to its original location, cleaning the impeller of pump, supply & replace gland rope, greasing, replacement of unserviceable spares of pump, fixing back in position, connecting back electrically and mechanically with proper alignment and testing complete all as specified and as directed for 15/20/30HP capacities of centrifugal/monoblock pumpsets of any make. NOTES: (i) Insulation of winding shall be Class "B" upto 7.5 HP and Class "F" for 10 HP and above. (ii) Spares like bronze impeller, bearing, bush, bronze casing ring, gland plate shall be measured and paid separately under relevant items of this BOQ as SUPPLY ONLY. (ii) Old material obtained from replacement shall be contractor"s property as per Schedule of credit given in tender.
85All as per item no.84 here-in-before but for 7.5/10 HP capacity.
86All as per item no.84 here-in-before but for 3/5 HP HP capacity.
87SUPPLY ONLY bearing double jet suitable for for 15/20 HPcapacities of pump and motor as per OEM:- MAKE: SKF/TATA/NBC
88All as per item no.87 here-in-before but for 7.5/10 HP capacity.
89All as per item no.87 here-in-before but for 3/5 HP HP capacity.
90SUPPLY ONLY bushing suitable for 15/20 HP capacities of pump and motor as per OEM:- MAKE: SKF/TATA/NBC
91All as per item no.90 here-in-before but for 7.5/10 HP capacity.
92All as per item no.90 here-in-before but for 3/5 HP HP capacity.
93SUPPLY ONLY gland plate stuffing box including MS coupling with key suitable for 15/20 HP capacities of pump and motor as per OEM.
94All as per item no. 93 here-in-before but for 7.5/10 HP capacity.
95SUPPLY ONLY bronze impeller suitable for 15/20 HP capacities of pump and motor as per OEM.
96All as per item no.95 here-in-before but for 7.5/10 HP capacity.
97SUPPLY ONLY bronze casing ring suitable for 15/20 HP capacities of pump and motor as per OEM.
98All as per item no.97 here-in-before but for 7.5/10 HP capacity.
99Checking of DG Set internel connections like battery connections, solenoid adjusting and PCBcontoller etc and tuning of DG Set of capacity 40KVA to 125KVA when and as required basis complete all as directed.
100Checking of DG Set internel connections like battery connections, solenoid adjusting and PCBcontoller etc and tuning of DG Set of capacity 160KVA to 400KVA when and as required basis complete all as directed.
101Checking of DG Set internel connections like battery connections, solenoid adjusting and PCBcontoller etc and tuning of DG Set of capacity 1250KVA to 2000KVA when and as required basis complete all as directed.
102S&F PCB Controller as per existing make and model as per site requirementfor 1250/2000 KVA DG set including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
103S&F PCB Controller as per existing make and model as per site requirementfor 400/250/160 KVA DG set including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
104S&F PCB Controller as per existing make and model as per site requirementfor 40 to 125 KVA DG set including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar.
105S&F in repairs fuel hose pipe/lube oil hose pipe of 10mm to 25mm dia (300psi) flexible type, heavy duty as per existing length for 1250/2000KVA DG Set complte all as directed.
106S&F in repairs fuel hose pipe/lube oil hose pipe of 10mm to 25mm dia (300psi) flexible type, heavy duty as per existing length for 400/250/160KVA DG Set complte all as directed.
107S&F in repairs fuel hose pipe/lube oil hose pipe of 10mm to 25mm dia (60psi) flexible type, heavy duty as per existing length for 40 to 125KVA DG Set complte all as directed.
108S&F in repairs water hose pipe/fuel hose pipe/lube oil hose pipe of 32mm to 50mm diac flexible type, heavy duty as per existing length for 1250/2000KVA DG Set complte all as directed.
109S&F Star Delta starter with Dry run trip, Single phasing and Phase reversel protection , CT coils and relays suitable for 10 to 15 HP capacity and as per existing make & model
110S&F DOL starter up to 7.5HP Capacity and as per existing make & model complete all as specified and directed.
111S&F Push button suitable for Pump set control panels (Red&Green) complete all as per direction of engr-in-charge.
112M&L Cotton waste for cleaning of DG sets all as specified and as directed by Engineer-in-charge.
113S&F Belt V ribbed type to drive alternator from pulley as per existing maodel and make for 40 to 125KVA DG Set complete all as specified and as directed by Engineer-in-charge.
114S&F Belt V ribbed type to drive alternator from pulley as per existing maodel and make for 160 to 400KVA DG Set complete all as specified and as directed by Engineer-in-charge.
115Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mouted at any height and ceaningwith cleaning agents, metal filling as per site requirementfor 1250/2000 KVA DG sets installed at 3.6MW Power house, refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
116Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mounted at any height and ceaningwith cleaning agents, metal filling as per site requirementfor 400/250/160 KVA DG sets installed at 3.6MW Power house, refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Perkins.
117Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mounted at any height and cleaningwith cleaning agents, metal filling as per site requirementfor 40 to 125KVA DG sets installed in Haddo station, refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washersincluding making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Greaves.
118Taking down old Silencer Exhaust pipe and S&FSilencer Exhaust pipe with wool insulation of any dia and length of existing make and model mouted at any heightas per site requirementfor 40 to 160 KVA DG sets installed at haddo station with necessary new nuts, bolts and washersincluding making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge. Make of DGSet: Cummins/Kirloskar/Greaves.
119Taking down copper/aluminium point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materialsand making good disturbed surfaces of walls, floors, etc.
120Taking down fuse Unit/DBs 415 Volt/230 Volt.
121Taking down old aluminiumsub main wiring ofany size.
122Taking down existing light fittngs any type and any capacity.
123M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLS PVCinsulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed conduit of size not less than 20 mm dia, with all necessary fittings, concealedin walls /roof/ floor duly earthed with one run of single core cable of same size but green incolour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricatedMS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-
124Description same as per Srl item No 123 above but One light/fan point controlled by one switch 5 Amps one way.
125Description same as per Srl item No 123 above but,point wiring for 3 pin switch socket outlet , 5 Amps on independent board.
126Description same as per Srl item No 123above but,point wiring for 3 pin switch socket outlet , 5 Amps on same board .
127All as per item No. 123 above but point wiring with 4.0 sqmm PVC FRLS insulated multistranded copper conductor suitable for one 3 pin 15 Amps socket out let and Geyserand one run of 4.0 sqmm cable for earth in green colour on independent board.
128Taking down old corroded GI bracket of 25 mm dia and supply and fixing new GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed
129S & F30 wattsLED building security light fittings , pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 with pranuts including necessaryfixing arrangements as per site requirements class all as specified and directed . Make : Luker Cart Part No: LSTE-30 or equivalent to Philips /Havells/CG
130M & L for taking down of ceiling fan and deposite to MES yardand S & F Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
131Taking down carefully exhaust fan of any make, size from its location, handed over to AGE E/M store yard without any damage
132Supply & fix heavy duty exhaust fan 300mm sweep iron dody 1400 RPMwith louversincl all fixing allangement complete all as specified and directed Make: CG,Model No: Drift Air Plus Metal or equvalent make is Havells/Orient/ Usha
133Supply & fix heavy duty air ventilation fan 250mm sweep PVC dody 1400 RPMwith louversincl all fixing allangement complete all as specified and directed Make: CG,Model No: BRIEF AIR NEO or equvalent make is Havells/Orient/ Usha
134Supplying, fixing andtesting Tube light fittings LED 20 watts 4 feetincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make: Luker Cat Part No : LT5M20 or equivalent to CG/Philips Havells/Luker
135Supply and fixing andtesting Tube light fittings LED 10 watts 2 feetincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified anddirected. Make: Luker Cat Part No : LT510P or equivalent to CG/Philips Havells/Luker
136S & F Sub main wiring with PVC insulated FRLS cable 2 single core 6 sq mm 1100 V grade with stranded copper conductor cableusing proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green in and incl rigid rigid , non-metallic PVC concealed conduit of size not less than 20 mm dia, with all necessary fittings, concealedin walls /roof/ floor incl all specials/accessories etc and provision of PVC insulated FRLScopper conductor single core 6.0 sq mm for earthcontinuity all as directed. Note : 3 lengthof cable and one length PVC Conduitshall be measured and paid for one length Make:Gloster /Havells /Anchor /Polycab /Finolex
137S & FTPNDB sheet metal enclosure double door suitable(IP-43) Protection 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : C&S/ Indo Asian /Havells /L&T
138S & FSPNDB sheet metal enclosure double door suitable(IP-43) Protection 8 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete. Make : C&S/ Indo Asian /Havells /L&T
139Supplying & fixing MCB TPN 63 Amps (`C’ series) having current rating 10 KA complete all as specified and directedMake : IndoAsian/Havells/L&T
140Supplying & fixing MCB SPN 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directedMake : IndoAsian/Havells/L&T
141Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed Make : IndoAsian/Havells/L&T
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail