Tender For Repair To Flooring, Plastering And Misc Br Work At Officer Mess Area Under Age B/R-I, Ge (Af) No 02 Jodhpur, jodhpur-Rajasthan

Military Engineer Services-MES has published Tender For Repair To Flooring, Plastering And Misc Br Work At Officer Mess Area Under Age B/R-I, Ge (Af) No 02 Jodhpur. Submission Date for this Tender is 03-06-2024. Tile Flooring Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43317500
Corrigendum : Tender For Repair To Flooring, Plastering And Misc Br Work At Officer Mess Area Under Age B/R-I, Ge (Af) No 02 Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
03-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair To Flooring, Plastering And Misc Br Work At Officer Mess Area Under Age B/R-I, Ge (Af) No 02 Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
e896cd6e-41ef-4804-b5ce-092abd706d71.html Tender Notice 0 KB
BOQ_730474.xls Tender Document 0 KB
Tender.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : Repair to flooring, plastering and misc B/R work at Officer Mess area under AGE B/R-I, GE (AF) No.2 Jodhpur
Sl. No. Item Description
1Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises.
3M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.06 Sqm but n. exc. 0.11 Sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6
4M&L for glazed ceramic tiles, coloured, 450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces.
5M&L for light & dark coloured vitrfifed tiles 9-10 mm thick area of each tiles not less than 0.36 Sqm in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1;6
6M&L for 25mm thick PCC in sub-base Cement concrete type B-1,1:2:4 (20mm graded aggregate)
7All as per item no. 5.00 above but on vertical surfaces such as dados skirting and risers to step set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick renedering in CM 1:4 on stone masonary surfaces
8M&L for granite (of any type ) tiles 18-20 mm thick machine cut in skirting /dado over and including 10 mm thick rendering in CM 1:4 on stone masonry surfaces jointed with grey cement slurry and pointed with white cemewnt with admixture of pigment to match the shade of granite stone including grinding and polishing complete
9M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingomplete including 15 mm thick screed bed or bedding layer in CM 1;6
10M&L 50mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floor, finished surface even and fair without using extra cement complete all as specified and directed.
11M&L Glass dividing strips, 38mm wide, 3mm thick and inserted in portion to confirm to design complete all as specified and directed.
12M&L 75 mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection finished surface even and fair without using extra cement complete all as specified and directed.
13M&L 75mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floor, finished surface even and fair without using extra cement all as specified.
14M&L Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified.
15M&L for Squared rubble walling Jodhpur type, regular coursed, well bonded, bedded and solidly hearted, built, built in CM 1:6 complete all as specified and directed.
16ditto as per item No 15 abovebut except stone complete all as specified and directed.
17Extra over items as above for hammer dressing to face stones with maximum depression on face from a straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type,brought upto courses complete all as specified and as directed.
18M&L for keyed pointing, to squared rubble, coursed or uncoursed in CM 1:4 complete all as specified and as directed.
19M&L for Pre-cast cement concrete block masonry type C1, 20 mm graded aggregates 1:3:6 set in CM 1:4with solid blocks, exc. 10 cm in width and setting in mortar, complete ®
20M&L for 100mm Cement concrete type D-2, 1:4:8 (40mm graded aggregate)as in sub base of floor.
21M&L for 30mm Sand filling under floors or in foundations including watering and consolidation under paver blocks
22M&L for Machine pressed precast concrete interlocking paver block any shape and size rubber moulded confirming to IS 15658-2006 of 60 mm thickness, M-35 grade With grey cement and pigments.
23M&L for pre polished chemically treated rubber moulded chequered cement concrete coloured tiles 30cm x30cm x20 to 25mm thick set, jointed and pointedwith grey cement and pigments in neat cement slurry laid over 20mm thick screed bed in CM 1:6. in floors and pathcomplete all as specified and as directed.
24M&L for Removing excavated material to a distance exc 500.00 M but n exc 1.50 Kmand depositing where directed at a level n exc 1.50 KM above starting point complete all as specified and directed by the Engineer -in-charge.
25M&L for Pre-cast cement concretefactory made kerb stonewith 1:3:6 type C1 (20mm graded Stone aggragate) solid blocks, exc. 10 cm in width and setting in mortar,CM 1:6 complete all as specified and directed.
26M&L for preparation ofnew surface/untreated old surface of brick, stone, concrete, asbestos plastered orunplastered surfaces of walls and applyingtwo coat of plastic emulsion paintin different colour over a coat of primer, complete all as specified and directed.
27M&L Cleaning and removing all scale dirt etc. from water storage tanks and from mouth of circulating pipes etc. and writing the date of cleaning and next due date for cleaning of tank, capacity of tanks exc. 500 liters and not exc. 1000 liters complete all as specified and as directed.
28Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete, brick work , masonry etc any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
29Dismantling fencing wire mesh, of any type complete all as specified and directed.
30Excavating in post holes in hard soil,each n.exc. 0.5cum,getting out, and removing surplus soil to a distance n.exc. 50m and making good surface.
31M & L PCC Type D2 (40mm graded aggregate) 1:4:8 in foundations,filling and mass concrete.
32Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
33Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire. Complete all as specified and directed.
34S&F mild steel screw bolts (machine made )75mm long, 12mmm diawith hexagonal or sqsuare head at one end and screw the other, or screwed bolt ends, each screw end to be fitted with washer and one hexagonal or square nut, exc 5cm but n.exc 10cm long.
35S&F MS flat iron fillets for securing to wire mesh with angle/rcc Posts including cutting tops to shape as directed,drilling holes,notching for wire etc.: including all necessary drilling,bolting and similar work conforming to Fe 290 Gde E-165.
36S&F post and struts in fencing including cutting tops to shape as directed, drilling holes notching for wire, etc. flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 Complete all as specified and directed.
37M&L for applying two coats of synthetic enamel oil painting over priming a coat of red oxide zinc chrome including preparation of new untreated steel surfaces over 10cm width or girth.
38M&L for applying two coats of syethetic enamel oil painting over priming a coat of red oxide zinc chrome including preparation of new untreared steel surfaces n.exc. 10cm width or girth when unconnected with other painting.
39S&F mild steel round bars 10mm dia and over, cut to length bent to shape reqd,incl cranking bending spirally for hooping of columns,hookingendsandbinding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips Fe-410 (Gde E-250) quality- A or Fe 290 (Gde- E165) quality controlling as directed.
40M&L for taking down cement plaster on PCC/brick surfaces including raking out joints hacking for key scrubbing down with water etc., complete all as specified & directed.
41M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified
42M&L for preparation of newly plastered surfaces of wall & applying two coats of exterior weather coat of approved shade/tint over one coat of appropriate primer complete all as specified & directed.
43M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified
44M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over complete all as specified & as directed.
45M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
46M&L for preparation of newly plastered surfaces of ceilings & applying three coats of white wash complete all as specified.
47M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash.
48M&L for preparing old plastered surfaces of walls by "Vacuum based sanding machine after complete removal of existing treatment and applying two coats Acrylic distemper of approved manufacture of required shade and colour complete as per manufacturer instructions by Auto roller machine over a coat of alkali resistant primer over a thin layer of wall care puttycomplete all as specified and directed.
49M&L for preparation of old decorated plastered or unplastered surfaces of walls applying one coat of cement base paint, white or tinted, all as specified and as directed by Engineer-in-Charge. Preparing old surfaces plastered or unplastered surface of wall by brooming down or steel wire.
50M&L Providing precast cement concrete type C0 1:2:4, CM 1:4louvres and jallies, 50mm thick (measured solid), including allmould- ings but excluding frame(Pre cast frameshall be measuredseparately andpaid for under item 51.00)
51M&L Providing precast cement concrete type C1 1:3:6 in CM 1:6 in win- dow or door cills,jali frame , lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match
52M&L Providing Stone Jallies jodhpur type 48-50 mm thick and 60 cm high fixed in line incl stone pillar having size 100x100MM in CM 1:4 fixed on Stone runner beam (stone pillar measured with Jalli).
53M&L Providing bottom runner stone beam (jodhpur type) fixed in line incl excavations having size 100x150 MM in CM 1:4 & make ready forfixing of jodhpur stone jalii & Pillar.
54M&L for Mild steel, plain, black sheet 1.00 mm thickin wall cladding, steel gates, Main hole cover and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
55M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
56M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shaperequired including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
57M&LDismantling of Wall and ceiling boards (fibrepulp, insulation, etc.) oinsulation boards/slabsblankets, any thickness, includincover fillets
58M&LAnodised aluminium snap grid frame work for false ceiling & Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specifiedall as specified
59M&L 10mm thPVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specifiedall as specified
60S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates GDE Fe290(E-165)
61M&L MS work as in wind ties for roof incl securing bolts complete conforming to Fe290 Gde E-165
62M&L Pre-painted galvalume aluminium Zinc coating GI based corrugatedsteel sheet of an colour having tensile str of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified.
63Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding, flooring above ground floors) including roof treatment and removing from site all as specified and directed.
64M&L for 50 mm thick (average) cement concrete 1:3:6 type C-0 mix (12.5 mm graded stone aggregate) in padding over roof.
65M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified. NOTE :Water proofing compound shall be measured and paid for separately as “Supply only”
66Supply only integral water proofing compound ISI marked.
67M&L for complete removal of existing Old App membrane treatment from roof surface complete all as specified and as directed by Engineer-in-Charge.
68M&L Supply and laying of Atactic Polypropylene modited polymeric standard SoM membrane of weight not less than 3 kg/sqm, made out of 90 micron high density polyethyiene film sand witched between two layers of polymenc (ATACTIC POLY PROPYL ENT BASED) bitumen and finally leminated on both sides with 20 micron KiMHDPE him laid over and including a priming coat of applied @ 0.3 itreisq m with 100mm overlap of the membrane shall be fused uniformly By LPG torch flame and applying hot blown bitumen 85/25 grade @1.20 kgisa m and the entire surface shall be painted with a coat of bituminious aluminium paint @100 mL/sq m complete all as specified and as directed by Engineer-in-Charge
69Disconnecting existing tanks, any capacity, setting aside (or lowering if required) for repairs of roofs and hoisting if required, reconnecting and refixing in position (Repairs to roofs measured separately).
70Disconnecting existing tanks of any description exc. 250 ltrs and n.exc. 500 ltrs capacity and removing from site.
71Disconnecting existing tanks of any description exc. 500 ltrs and n.exc. 1000 ltrs capacity and removing from site.
72S&F 500 litres (ISI Marked) capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top thread type cover), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)
73S&F 1000 litres (ISI marked) capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top thread type cover), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)
74Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site.
75Taking up or down steel tubing 20mm bore and connections including cleaning for refixing or removing from site.
76Refixing old steel tubing, 15mm bore, and connections with new or old position (Walls, ceiling, floors, etc.) Note :- Steel tubes obtained from item No. 75 above shall be used under this item.
77Refixing old steel tubing, 20mm bore, and connections with new or old position (Walls, ceiling, floors, etc.) Note :- Steel tubes obtained from item No. 75 above shall be used under this item.
78Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
79Supply and laying 20mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail