Tender For Certain Repairs/Replacement To Lt Distribution Cables,Lightening Protection ,Earthing Pits And Lt Distribution System,Oh Lines With Connected Items Including Repair/Maintenance Of Fire Fighting Installation And Connected Works In Technica, Leh-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Certain Repairs/Replacement To Lt Distribution Cables,Lightening Protection ,Earthing Pits And Lt Distribution System,Oh Lines With Connected Items Including Repair/Maintenance Of Fire Fighting Installation And Connected Works In Technica. Submission Date for this Tender is 20-05-2024. Electrification Work Tenders in Leh Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43317495
Tender For Certain Repairs/Replacement To Lt Distribution Cables,Lightening Protection ,Earthing Pits And Lt Distribution System,Oh Lines With Connected Items Including Repair/Maintenance Of Fire Fighting Installation And Connected Works In Technica
Open Tender
Indian
Jammu And Kashmir
Leh
20-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Certain Repairs / Replacement To Lt Distribution Cables, Lightening Protection , Earthing Pits And Lt Distribution System, Oh Lines With Connected Items Including Repair / Maintenance Of Fire Fighting Installation And Connected Works In Technical Area And

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
da6c31fe-f334-46b9-9138-a933e8db7500.html Tender Notice 0 KB
12Reten.pdf Tender Document 0 KB
BOQ_730295.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work :CERTAIN REPAIRS/REPLACEMENT TO LT DISTRIBUTION CABLES,LIGHTENING PROTECTION ,EARTHING PITS AND LT DISTRIBUTION SYSTEM,OH LINES WITH CONNECTED ITEMS INCLUDING REPAIR/MAINTENANCE OF FIRE FIGHTING INSTALLATION AND CONNECTED WORKS INTECHNICAL AREA AND DOMESTIC AREA AT 21 WING AF STATION LEH UNDER GE (AF) LEH.
Sl. No. Item Description
1Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in any type of soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches , complete all as specificed and directed by Engineer-in-Charge.
2Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified anddirected by Engineer-in-Charge.
3Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified anddirected by Engineer-in-Charge.
4Sand cushioning to under ground cable with clean dry sand locally available with layer of sand8cm thick before laying of cable and 15 cm after laying ofcable, complete all as specified and directed by Engineer-in-Charge. Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
5Factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dryin trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other in and including taking down old unservicable cable cover, complete all as specificed and directed by Engineer-in-Charge.
6LT under ground electric power cablecrossed linked polyethylene ( XLPE)insulated, galvanised steel strip or wire armoured,ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 120 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable , complete all as specified and directed by Engineer-in- Charge. Note :Excavation, earth work, sand cushioning, protection bricks/ tiles/ block andpipe shall be measured and paid separately under appropriate items.
7All as per item No 6 here-in-beforee but size 95 sqmm 3.5 core.
8All as per item No 6 here-in-beforee but size 50 Sqmm 3.5 core
9All as per item No 6 here-in-beforee but size 25 sqmm 4 core.
10All as per item No 6 here-in-beforee but size 16 sqmm 4 core.
11All as per item No 6here-in-beforee but size 10 Sqmm 2 core.
12Mild steel galvanized tubes light grade ISI marked 80mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
13Mild steel galvanized tubes light grade ISI marked 50mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
14Mild steel galvanized tubes light grade ISI marked 40mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
15Cable jointing kit for 1.1 KV grade cablestraight through joints (tubular sleeve version) , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 25/50 Sqmm , complete all as specified anddirected by Engineer-in-Charge.
16Cable jointing kit for 1.1 KV grade cablestraight through joints (tubular sleeve version) , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 70/150 Sqmm , complete all as specified anddirected by Engineer-in-Charge.
17Cable jointing kit for 1.1 KV grade cablestraight through joints (tubular sleeve version) , heat shrink type, joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 185 Sqmm , complete all as specified anddirected by Engineer-in-Charge.
18Dressing of LT panels/Bus bars/Poles by excavating the cable loop, dressing of cable properly by cutting the damaged part and dressed with insulation tape, thimble, nuts, bolts and washers etc., complete all as specified and directed by Engineer-in-Charge. Note: Quoted Rates shalldeemed to be inclusive of taking down the existingcables, dressing the cable properly with lugs, nuts, bolts washer etc. & refixing the same including excavation and earth work, returning filling and removal of surplus soils .
19Cutting existing road/ PCC hard standing / pavement / drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B1 using 20mm graded aggregates including all excuation and earth work , complete all as specified and directed by Engineer-in- Charge. Note:- Only PCC shall be measured and paid separately.
20Re-stretching ofaluminium conductorany size and length complete including removing kinks and providing new binding wire /Jumper where required ,complete all as specified and as directed by Engineer-in-Charge. Note : Length of each conductor to be measured separately for payment purpose.
21MCCB 4 pole current rating 63 Amps 16 KA with fixed thermal and fixed magnetic setting , 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
22MCCB 4 pole current rating 100 Amps 25 KA with fixed thermal and fixed magnetic setting, 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
23MCCB 4 pole current rating 125 Amps 36 KA with fixed thermal and fixed magnetic setting , 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
24MCCB 4 pole current rating 160 Amps 36 KA with fixed thermal and fixed magnetic setting , 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
25MCCB 4 pole current rating 200 Amps 36 KA with adjustable thermal and adjustable magnetic setting , 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
26MCCB 4 pole current rating 250 Amps 36 KA with adjustable thermal and adjustable magnetic setting , 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
27MCCB 4 pole current rating 320/315 Amps 36 KA with adjustable thermal and adjustable magnetic setting , 415 Volts AC, 50 Hz,including connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified anddirected by Engineer-in-Charge.
28On-load change over switch I-O-II4 pole 415 volts 50 Hz of capacity 200 Amps including nuts bolts and washerand connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable Change over switch , complete all as specified anddirected by Engineer-in-Charge.
29On-load change over switch I-O-II4 pole 415 volts 50 Hz of capacity 250 Amps including nuts bolts and washerand connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable Change over switch , complete all as specified anddirected by Engineer-in-Charge.
30On-load change over switch I-O-II4 pole 415 volts 50 Hz of capacity 400 Amps including nuts bolts and washer and connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable Change over switch , complete all as specified anddirected by Engineer-in-Charge.
31Off-load change over switch side handle operated 4 pole 415 volts of capacity 200 Amps including nuts bolts and washer and connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable Change over switch , complete all as specified anddirected by Engineer-in-Charge.
32Off-load change over switch side handle operated 4 pole 415 volts of capacity 400 Amps including nuts bolts and washer and connecting with existing system and cabling network andmaking good disturbed surfaces, testing in and including taking out unserviceable Change over switch , complete all as specified anddirected by Engineer-in-Charge.
33Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above groundin and including taking out unserviceable Aluminium strip , complete all as specified anddirected by Engineer-in-Charge.
34Copper strip of size 20 x 3.15 mm to interconnect the earth pit to equipment room includingPVC shaddle as per sample approvedcomplete all as specified and directed by Engr-in-Charge. in and including taking out unserviceable copper strip , complete all as specified anddirected by Engineer-in-Charge.
35Air termination single pointed aluminium rod, 12 mm dia, 300 mm long including mounting arrangment in and including taking down of old unserviceableair termination, single point of any type and size, complete all as specificed and directed by Engineer-in-Charge.
36Air termination single pointed copper rod, 12 mm dia, 300 mm long including mounting arrangment in andcomplete all as specificed and directed by Engineer-in-Charge.
37Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw in and including of dismanteling of old unservicable test point bock , complete all as specified and as ditected by Engineer-in -Charge.
38Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in and including dismantling of old cross arm, complete all as specified and as directed by Engineer-in-Charge.
39Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees , complete all as specified and as directed by Engineer-in-Charge. Notes :(i). Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. (ii) The cutting / trimming of tree branches shall be done atleast 2.00 metre radius of OH line. (iii) The unit of measurement is "SPAN" i.e. distance covered between two poles.
40Weather proof outdoor bus bar chamber(CPRI approved), made out of 3.15mm thick MS sheet with front & rear Opening, powder coated, dust & vermin proof, IP-66 Protection comprising4 Nosaluminium strips each of 200 Amps, 60cm longhaving 10cm min distance from the body and between bus bars, fixed in steped way duly insulated mounted on epoxy insulators in horizontal position in stepped manner with 4 No’s mounting legs made out of 40mm x 40mm x 6mm angle iron grouted in PCC block(30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), andone MCCB of 160 Amps, 16 KA4 pole as incomer connected with bus bars by means of suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils complete all as specified and directed by Engr-in-charge. , in and including taking down of old unserviceable Bus bar ,complete all as specified and as directed by Engineer-in-Charge. Notes:(i) Drawings for LT Panel shall be got approved from Engineer-in-Charge before placing the order .This aspect shall be inclusive in the quoted Rate. (ii) Quoted Rates are inclusive of taking down the existing all cables, dressing the cable properly with lugs, nuts, bolts washer etc. & refixing the same including excavation and earth work, returning filling and removal of surplus soils .
41Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soilto a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMTbars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth leadprotection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,including dismanteling of old unserviceable earthing ,complete all as specified and as directed by Engineer-in-Charge. Note:(i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 1.00 metre away from earth.
42FIRE FIGHTING SCHEDULE
43M & L forservicing of diesel engine after dismantling and draining out the engine oil , taking down old fuel filter, oil filter and air filter, nozzles etc., cleaning the engine oil chamber, aircleaner, servicing to pumps and nozzels etc replacing the air filter, oil filter and fuel filter,nozzlesand engine oil complete all as specified and directed.
44M&L forservicingof diesel engine driven pump of capacity of 50HP after dismantling and cleaning including washing with replacement of bushes if required complete and refixing the same all as specified and directed with the satifaction of Engr-in-charge.
45M&L forrepairing/servicing ofPressure Jet burner of Boiler after dismantling and taking out the unserviceable pressure jet burner replacing the unserviceable parts (photocells,fuel nozzels,ignition transformers) and refixing to its original place after testing to the entire satisfaction of Engr-in-Charge.
46M&L for servicing of Boiler unit completeconsisting of closely wound helical concentric coils arranged to give adequate no of passes on flue gas side made out of ERW tubessuitable for high temperaturedismantling the pressure jet burner, combustion air fanetc and connected accessories servicing refixing the same to its original placesafter complete all as specified and directed.
47M & L for dismantling the unserviceable/ leaked Heat Exchanger from the Sump,taking out the unserviceable/rusted 25mm MS tubing part & replacing the complete unserviceable MS Tubing parts including MS Tube 25mm dia heavy grade, bends, elbows & welding/ fabrication work complete and refixing to its original place andtesting after commission to the entire satisfaction of Engr-in-Charge. Note : a) The rate quoted includes cost of fabrication of new Heat Exchanger, welding works/ gas cutting & fabrication work along with all necessary items. The desigh of heat exchanger should be as per the instruction of Enginer in Charge. b) Gate Valve Shall be paidand measured separetely in respective item
48Supply and filling of Glycol in barrel of 210 Ltrs complete all as specified and directed
49Dismantling the existing unserviceable first aid hose reel drum and supply and fix in replacement of first aid hose reel drum complete swing type 30mconforming to IS- 444 (1980). Make: Padmini / Winco/ CRC
50S&F in replacement non brittle rubber ring/Gasket as per site requirement of fire hydrant coupling of dia 25mm complete all as spicified and directed.
51Taking down the existing unserviceable Brass shut off nozzel andsupply and fix in replacement ofshut off nozzle suitable for 20mmhose complete all as specified and directed.
52Taking down the existing unserviceable rubber hose reel of dia 20 mmand supply and fix in replacement of required length of hose reel for innetconnection in fire junction box with clamps complete all as specified and directed.
53Taking down the existing unserviceable perpex sheet and S&F in replacementclearPerpex sheet 3mm thick of various sizes of fire boxcabinetcomplete all as directed .
54Supply and filling of Foam Concentrate 1:18 (AFFF Foam) in barrel of 210 LTRS complete all as specified and directed
55Supply and filling ofantifreeze coolant for Diesel Driven DG set of fire fighting installation at 114 HU.
56Taking down the existing unserviceable Non Return butterfly valve and supply and fix in replacement Non Return butterfly valve 200 mm dia complete all as specified and directed.
57Taking down the existing unserviceable Non Return butterfly valve and supply and fix in replacement Non Return butterfly valve 150 mm dia complete all as specified and directed.
58Taking down the existing unserviceable Non Return butterfly valve and supply and fix in replacement Non Return butterfly valve 100 mm dia complete all as specified and directed.
59Excavation in trenches nexc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, erection of poles complete all as specified.
60Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soilcomplete all as specified.
61Removing surplus excavated soil nexc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point.
62Taking out the existing unserviceable/corrodedMS/ERW Pipe and supply and lay MS/ERW pipe 100mm dia bore, medium grade in replacement laid in trenches or on ground/ vertically with necessary peopted cover as per IS and welded joints including removing the rusted, broken old MS/ERW pipe and painting with two coats of synthetic enamel paint over a coat of zinc chrome primer all as directed.
63Taking down the existing unservicable/ broken GI Pipe and supply & laid in replacement GI pipe medium grade with all necessary fittings fixed to wall/ ceiling/ floor complete of size 25 mmdia complete all as specified and directed
64Dismantling the exisiting unserviceable pressure guage and Supply & Fix in replacement Pressure guage suitable for 150mm (6" ) dia delivery pipe line 0-16 Kgs rating complete all as specified and directed.
65Taking down the exisiting unserviceable Ball valve and Supply & Fix Ball valve made of cast Iron/ Gun Metal heavy duty, threaded ends suitable for fire Hydrants system of size 25 mm dia as per site including fittings all as specified and directed.
66Taking down the existing unserviceable fire response indicator, supply and fix in replacementFire response indicatorhaving two nos of LEDs written FIRE as per exisiting system including wiring connection with 2core copper cable with existing panel complete all as specified.
67Taking down the exisiting unserviceable smoke detectors Supply and fixaddressable Optical smoke analogue light scattering type usinga pulsed internal infrared LEDand a silicon photo diode reciever including wiring connection with 2core copper cable with existing panel addresable panel complete all as specified.
68Taking down the exisiting unserviceable UVIR type flame detectors andsupply and fix in replacement Optical ultra violet and infra-red type flame detectors suitable to give visual alarm on detection of fire including wiring connection with 2core copper cable with existing panel complete all as specified.
69Taking down the exisiting unserviceable heat detectors Supply and fixaddressable Optical heat detector analogue suitable to work on rate of rise of ambient temp and fixed temp including wiring connection with 2core copper cable with existing panel addresable panel complete all as specified.
70Taking down the exisiting unserviceable manual call point Supply and fix manual call point duly housing in CRCA Sheet normally closed by glass complete all as specified and directed
71M & L for replacement of UNSV/ Leaked impeller casingwith new impeller casing of Jockey Pump DB 32/26 ( Make- Kirloskar) of Cap 15 HP as per site requirement as directed by Engineer-in-Charge
72M & L for replacement of UNSV/ Leaked impeller casingwith new impeller casing of Main Pump DB 65/26 ( Make- Kirloskar) of Cap 50 HP as per site requirement as directed by Engineer-in-Charge
73M & L for alignment of coupling of pump impeller with 15 HP electric motor as per site requirement all as specifed and directed by Engr-in-Charge
74M & L for alignment of coupling of pump impeller with 50 HP electric motor as per site requirement all as specifed and directed by Engr-in-Charge
75Material and labour for preperation of old painted surfaces of following items/equipments and applyingtwo coats of synthetic enamel paint as per specifiedcolour codingon steel / iron surfaces complete all as specifiedfor Fire Fighting installation in 114 HU and as directed by Engineer-in-Charge:
76Mild steel / GI pipe lines of any size
77Diesel Engine and coupled pumpset
78Centrifugal pumpsets of any cap
79Fire reel hose cabinets
80Diesel Storage tank of cap 200 ltrs
81M & L for Insulation of M S Pipe of dia 40 mm with PUF slab 30 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheetafter tightening the slabs with GI wire completeall as specified and as directed
82M & L for Insulation of M S Pipe of dia more than 100 mm with PUF slab 40 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheetafter tightening the slabs with GI wire completeall as specified and as directed
83M & L for Insulation of M S Pipe of dia more than 150 mm with PUF slab 40 mm thick with and including applying bituminuous compound and Aluminium cladding with 26 gauge Aluminium sheetafter tightening the slabs with GI wire completeall as specified and as directed
84M & L in replacement of old unsverciable main fire control panel with new microprocessor based 12 zonefire control panel for fire protection system consisting ofbattery backup with build in charger complete digital type including making wiring connections of all zones and testing of fire alarm panel zone wise as per the satisfaction of Engineer-in-Charge. Make: Agni / Daksha / SystemSensor or equivalent. Note :- The quoted rates also includes the rates for testing and commissioning after installation of Fire Alarm Panel.
85Supply, erection, testing and commissioning of electronic type dual tone hooter after repair and replacement of UNSV parts with all accessories as per existing specifications and make including dismantling the existing one complete all as specified and directed.
86Repair/rewinding of UNSV fluid Circulation motor of capacity upto 1 HP including connection as per satisfaction of Engineer-in-Charge.
87Repair to wiring of Main Panel for Electric Supply to Pump and Motor and replacement of UNSV wiring, MCB/MCCB and other items in panel as per site requirement to make it proper Functional of Plant as per satisfaction of Engineer-in-Charge. Note: MCB/MCCB/Contactor/Switch/Lamp will be measured and paid separetly under relevant item of Sch A item 40.01 to 40.03.
88Supply & Fixing in replacement of MCB TP of 63 Amps as directed.
89Supply & Fixing in replacement of Contactor MNX 45 with overload relay as directed.
90Supply & Fixing in replacement of Contactor MNX 25 with overload relay as directed.
91M & L for copper armoured cable 1.5 Sqmmx 2 core for wiring of fire alarm controlcircuits complete all as specified and as directed by Engineer-in-Charge.
92Note : (a)In case any similar nature of item occur in BOQ ,the lowest unit rate will be considered for payment.(b)Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail