Tender For Work For Providing Supplying Installation Of Pumpset And Deepening Of Open Well No 5 In Summer Contiengency 2024 At Uwss Partapur, banswara-Rajasthan

Public Health Engineering Department-PHED has published Tender For Work For Providing Supplying Installation Of Pumpset And Deepening Of Open Well No 5 In Summer Contiengency 2024 At Uwss Partapur. Submission Date for this Tender is 14-05-2024. Submersible Pump Tenders in banswara Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43317370
Tender For Work For Providing Supplying Installation Of Pumpset And Deepening Of Open Well No 5 In Summer Contiengency 2024 At Uwss Partapur
Open Tender
Indian
Rajasthan
banswara
14-05-2024

Tender Details

Tender For Work For Providing Supplying Installation Of Pumpset And Deepening Of Open Well No 5 In Summer Contiengency 2024 At Uwss Partapur

Key Value

Document Fees
INR 500 /-
EMD
INR 19780.0 /-
Tender Value
INR 9.89 Lakhs /-

BOQ Items

Name of Work:Work for Providing Supplying And Installation Pump Sets and Deepening of Open well no. 5 In Summer Contigency 2024 At Uwss Partapur
Sl. No. Item Description
1Item: 5.5Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer s design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 5.5.611.0 KW (15 HP)
2Item: 5.5Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer s design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 5.5.715.0 KW (20.0 HP)
3Item: 2.18Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 2.18.2Above 10 HP and up to 15 HP
4Item: 2.18Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 2.18.3Above 15 HPand up to 20 HP
5Item: 2.19Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 2.19.23 core 6.0 Sq.mm
6Item: 2.20Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 2.20.110.0 Sq.mm, 4 core
7Item: 2.40Add extra over item No. 2.39.1 for every additional lift of 1.5 Mtr. or part thereof : In all kind of soils.
8Item: Structural steel work in single section fixed with connecting plate includingcutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. heightIn flates, tees, angles & Channals
9Item: 2.39Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan)for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter. 2.39.1All kind of soil 2.42 Add 20% extra over item No. 2.39 for excavation in saturated soil where pumping or baling out of water is required, including shoring strutting where required and dewatering.
10Item: Providing and layiny in position specified grade of cement concrete for RCC Structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement for Walls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc. M20 grade nominal mix (with graded stone aggregate 20mm nominal size)