}

Tender For Work For Providing Supplying And Installation Of Pumpset In Summer Contiengency 2024 At Uwss Banswara, banswara-Rajasthan

Public Health Engineering Department-PHED has published Tender For Work For Providing Supplying And Installation Of Pumpset In Summer Contiengency 2024 At Uwss Banswara. Submission Date for this Tender is 14-05-2024. Submersible Pump Tenders in banswara Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43317352
Tender For Work For Providing Supplying And Installation Of Pumpset In Summer Contiengency 2024 At Uwss Banswara
Open Tender
Indian
Rajasthan
banswara
14-05-2024

Tender Details

Tender For Work For Providing Supplying And Installation Of Pumpset In Summer Contiengency 2024 At Uwss Banswara

Key Value

Document Fees
INR 1000 /-
EMD
INR 32200.0 /-
Tender Value
INR 16.10 Lakhs /-

BOQ Items

Name of Work: Replacement of old pump sets and other contingent works at UWSS Banswara
Sl. No. Item Description
1Item: 5.7 Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ. 5.7.10Discharge 31 t0 40 LPS and head 41 to 50 M
2Item: 5.1Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 5.1.2Centrifugal Monoblock Pump set (Double Stage) 5.1.2.37.5 KW (10.0 HP)
3Item: 5.1Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 5.1.2Centrifugal Monoblock Pump set (Double Stage) 5.1.2.49.3 KW (12.5 HP)
4Item: 5.3Vacuum Pump set (Coupled) Providing, installation, testing and commissioning of Vacuum pump set with horizontal foot mounted TEFC squirrel cage motor working on three phase 50 Hz, 415 Volts +/- 10% with base plate including cost of flexible couplings, coupling guard etc complete in all respect as per specification, scope of work and direction of Engineer in Charge. 5.3.27.5 KW (10.0 HP)
55.7 Providing and fixing at site with necessary packing, Horizontal Centrifugal Split Casting pumps with 4 pole induction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ. 5.7.1 Discharge 20 to 30 LPS and head 20 to 30 M
6Item: 2.15SupplyandInstallation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fittingandaccessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 2.15.7 11 KW (15 HP)andhead up to 120 mtr.
7Item: 6.8 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following classanddia complete confirfing to BS- EN-1171/ AWWA C-509 and of following specifications: Bodyandbonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as bodyandshall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/ 410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointingandjointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 6.8.1Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 6.8.1.2100 mm dia
8Item: 6.8 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following classanddia complete confirfing to BS- EN-1171/ AWWA C-509 and of following specifications: Bodyandbonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as bodyandshall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/ 410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointingandjointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 6.8.1Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 6.8.1.3125 mm dia
9Item: 6.8 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following classanddia complete confirfing to BS- EN-1171/ AWWA C-509 and of following specifications: Bodyandbonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as bodyandshall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/ 410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointingandjointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 6.8.1Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 6.8.1.4150 mm dia
10Item: 6.20 Removing of existing CI/ DI Double flange sluice valves, non return valves, butter fly valves etc. in existing Distribution/ Rising Main/ Transmission Main pipe line of following sizes, works include de-jointing of valve, dewatering, taking it out of the pit with adequate safety arrangement at site and then refill the pit from excavated sand by ramming it at sides of pipeand up to ground level. Work shall be done as per specification, scope of work and direction of Engineer-in-charge. All old material shall be removed safelyandall old material shall be deposited in Divisional Store. Note: Rates are exclusive of earth work and road cutting. 6.20.2 100 mm
11Item: 6.20 Removing of existing CI/ DI Double flange sluice valves, non return valves, butter fly valves etc. in existing Distribution/ Rising Main/ Transmission Main pipe line of following sizes, works include de-jointing of valve, dewatering, taking it out of the pit with adequate safety arrangement at site and then refill the pit from excavated sand by ramming it at sides of pipeand up to ground level. Work shall be done as per specification, scope of work and direction of Engineer-in-charge. All old material shall be removed safelyandall old material shall be deposited in Divisional Store. Note: Rates are exclusive of earth work and road cutting. 6.20.3 125 mm
126.20 Removing of existing CI/ DI Double flange sluice valves, non return valves, butter fly valves etc. in existing Distribution/ Rising Main/ Transmission Main pipe line of following sizes, works include de-jointing of valve, dewatering, taking it out of the pit with adequate safety arrangement at site and then refill the pit from excavated sand by ramming it at sides of pipe and up to ground level. Work shall be done as per specification, scope of work and direction of Engineer-in-charge. All old material shall be removed safely and all old material shall be deposited in Divisional Store. Note: Rates are exclusive of earth work and road cutting. 6.20.4 150 mm
134.1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
14Item: 12.2 Storage Tank Silt clearance from Sedimentation cum storage tank with all lift and lead up to 50 Mtr. Silt to be disposed outside the Headworks boundaries. Disposed silt to be levelled and neatly dressed including stacking of useful material if any available during excavation for all kind of soil. Silt clearance is to be carried out by means of mechanical system i.e. Tractor craw/Trolley or any other mechanical system. No extra payment shall be done for lift . This workalso involves dressing ofbottom which is to be done manually and there shall be no damage to lining and LDPE film of tank. Work is to be done as per direction of Engineer In Charge and technical specifications. NOTE :- For additional lead, beyond 50M, every additional lead will be paid as per PWD BSR. But for lead of 500M, 1 km. and onward; initial rate of 50M will be deducted from concern rates of above said leads
15Item: 2.19SupplyandFixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 2.19.13 core 4.0 Sq.mm
16Item: 2.19SupplyandFixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 2.19.33 core 10.0 Sq.mm
17Item: 2.19SupplyandFixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 2.19.43 core 16.0 Sq.mm
18Item: 1.15Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixing inpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineasper technicalspecifications anddirection of Engineer-in-charge. 1.15.1MS pipespecialsupto600mmdia (withminimum5mmthickness sheet)
19Item: 7.2 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Baklight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Netural Links , Sprial , SaddleandPacking Material ) etc. and 100A/ 125A ,TPN, Aluminum Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. 7.2.6 STAR DELTA STARTER 22.0 KW (30.0 HP)- :For 2 motors (1 W+ 1S) I/C- MCCB 125A TPN 25 KA With T/M Based Over CurrentandShort Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCCB 100A TPN 25 KA With T/M Based Over CurrentandShort Circuit Protection (2), Power Cont 40A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A ) (2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 12.5 Kvar (2), S/D Timer(2)
20PART A REPAIR AND REWINDING OF MONOBLOCK PUMPS 3.7 Rewinding of three phase squirrel cage induction motor of Monoblock pump sets including all necessary material and of the same characteristics as original with required size of super enameled copper wire (including cost of copper wire) E class insulation material and testing of motor on no load but to be guaranteed against testing on load at site, including transportation of motor pump to and from Div/AEn/JEn store complete as per direction of engineer in charge. 3.7.5 12.5 HP
21Item:PART A REPAIR AND REWINDING OF MONOBLOCKPUMPS SUPPLYandFIXING OF SPARE PARTS FOR MONOBLOCK PUMPSET (MOTOR + PUMP) 3.8.1 Connection Plates 3.8.1.210 HP to 20 HP
22Item: 3.8 SUPPLYandFIXING OF SPARE PARTS FOR MONOBLOCK PUMPSET (MOTOR + PUMP) 3.8.4 Mechanical reconditioning of Bearing sheet 3.8.4.2 10 HP to 20 HP
23SUPPLY and FIXING OF SPARE PARTS FOR MONOBLOCK PUMPSET (MOTOR + PUMP) 3.8.7 Labour charge for opening and fitting of pump sets 3.8.7.2 10 HP to 20 HP
24Rewinding of three phase squirrel cage induction motor of HSC pump sets including all necessary material and of the same characteristics as original with required size of super enamelled copper wire (Including cost of copper wire) E class insulation material and testing of motor on no load but to be guaranteed against testing on load at site, including making electric connection at site of installation of motor with starter, alignment with pump sets and transportation to and fro from installation site complete as per direction of engineer in charge at site. 3.9.4 Above 25.00 HP but upto 30.00 H
25Item: 3.9 Rewinding of three phase squirrel cage induction motor of HSC pump sets including all necessary material and of the same characteristics as original with required size of super enamelled copper wire (Including cost of copper wire) E class insulation material and testing of motor on no load but to be guaranteed against testing on load at site, including making electric connection at site of installation of motor with starter, alignment with pump setsand transportation to and fro from installation site complete as per direction of engineer in charge at site. 3.9.6Above 35.00HP but upto 40.00 HP
26Item:3.9 Rewinding of three phase squirrel cage induction motor of HSC pump sets including all necessary material and of the same characteristics as original with required size of super enamelled copper wire (Including cost of copper wire) E class insulation material and testing of motor on no load but to be guaranteed against testing on load at site, including making electric connection at site of installation of motor with starter, alignment with pump setsand transportation to and fro from installation site complete as per direction of engineer in charge at site. 3.9.8 Above 45.00 HP but upto 50.00 HP
27Item: 3.11 JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.1 charges for Dismentaling and Assembling of Pump 3.11.1.220 HP to 30 HP
28Item: 3.11 JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.4 charges for Dismentaling and Assembling of Pump 30 HP to 50 HP
29Item: 3.11 JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.1Bearing Housing (rebuilding, turningandfinishing) 3.11.1.220 HP to 30 HP
30Item:3.11 JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.1Bearing Housing (rebuilding, turningandfinishing) 3.11.1.330 HP to 50 HP
31Item:3.11 JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.2 Bearing Cap (rebuilding, turningandfinishing) 3.11.2.2 20 HP to 30 HP
32JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.3 Impeller Reconditioning for all type of Pump 3.11.3.2 20 HP to 30 HP
33JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.3 Impeller Reconditioning for all type of Pump 3.11.3.3 30 HP to 50 HP
34Item: 3.11 JOB WORK FOR REPAIR OF PUMP MOTOR 3.11.3 Impeller Reconditioning for all type of Pump 3.11.3.3 30 HP to 50 HP
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail