Public Works Department-PWD has published Tender For Establishment / Upgradation Of Strong Rooms / Counting Halls At Govt.Degree College Baramulla (Boys Hostel And Indoor Stadium) Electric Work. Submission Date for this Tender is 11-05-2024. Electrification Work Tenders in baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 11-May-2024 | Earnest Money | Fee | 11-05-2024 |
Sl. No. | Item Description |
1 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
2 | 32 mm |
3 | Supply installation testing and commissioning of18 W +LEDSurface/recess, square or round Mountedlightluminaryfitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning)of lighting fixtures for a period of Two years ,which includes replacement offixtures ofPhilips/ Havel"s /Wipro make / sample to be approved before installation.. |
4 | S/F testing and comm. Of surface mounted LED Batten Alimunium Housing, 18 watt+ (Plus) commercial series (cool/warm) 4 ft. Philips make /Havell/ Crompton make of eq. standard. sample to be approved before installation. |
5 | S/F testing and comm. Of MCB"s of the below mentioned capacities in sub main controls legrandC curve/ Schinider/ L&T ./ equivalent make as directed by engineer incharge.6-32 Amp SP MCB |
6 | 40-63amp DP MCB |
7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,(Havell/Polycab/ Fenolex/ Anchor make.) single core cable in the existing surface/recessed steel/ PVC conduit as required including making necessary connections as required.2 x 1.5 sq. mm |
8 | 2 X 2.5 sq. mm |
9 | 2 X 4 sq. mm |
10 | 2 X 6 sq. mm |
11 | 2 X 10 sq. mm |
12 | 2 X 16 sq. mm |
13 | Supplying and fixing following modular switch/ socket ( Havell/ Anchor/ SSK make)on the modular plate & switch box including connectionsetc. as required, the job includes the cost of modular plate and switch boxes. 5/6 A switch |
14 | 15/16 A switch |
15 | 3 pin 5/6 A socket outlet |
16 | 6 pin 15/16 A socket outlet |
17 | Supply, installation , testing and commissioningof LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of greater than 120 lumen/Wattand a minimum system lumen output of 18000 lumens and maximum system wattage of 150 Watts.The fixture shall have a CRI of minimum 70, SDCM<5. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=07 with toughened glass cover.The fixture driver should have an operating voltage range of 140-270 V, inner surge protection of >=4KV, PF >0.95 and THD<10% at full load. Driver should cut off at high voltage of 320volt for safety. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics. Manufacturer shall have inhouse lab approved by NABL. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Philips/ Havell ( Jeta Aris)/ Wipro/ Crompton make ( sample to be approved before installation) . the job includes the angle iron frame of required size to be grouted in cement concrete for holding the luminaire.( complete Job) |
18 | Supply , installation testing and commissioningof energy saving LED lamps Havell/C&S/Philips make .15 Watt |
19 | Supply installation testing and comm.of 10- 16 amppower extension box ( 1 No. 6 amp switch,1 No. 16 amp switch, 3 No. 6 amp Multi socket and 1 No.6/16 Socket) with suitable size lead and top. C&S make. |
20 | Providing and fitting of 15 amp SS combineSSK / Anchor make. |
21 | Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block. |
22 | Providing and fittting of 15 amp 3 pin topSSK/anchor make. |
23 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, Outdoortype with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account,and other allied accessories etc. as required.( size may vary as per site requirement) |
24 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. Normal INCOMING:Onload Change over switch 160 Amp for generator.Front operated. |
25 | 4 No. of Aluminium Bus Bar of 200 Amp. |
26 | Digital meters and phase indicators -1 set. |
27 | OUTGOING: 63 amp DP MCBK Legrand/ Shinider/ Eq. standard make. |
28 | Space for 12 way MCB"s |
29 | S/L , testing and commissioning of PVC alluminium armoured cable650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard makeas directed by engineer incharge andmaking end termination with brass compression gland and aluminium lugs of required size.50 sq.mm 3.5 core |
30 | Supplying and fixing following way, Triple pole and neutral/ single pole and neutral, sheet steel, MCB distribution board,(legrand/ Shinider/ABB make) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
31 | Operationand maintenance of already existing 63 KVA D.G Set installed at indoor stadium baramulla.the job includes necessary servicing of D.G setby way of M.Oil change, change of air/fuel filters, coolant and allied worksetc.prior to its operation, periodic checkups during the period.the job also includes connecting of generator set to the load as per site requirements. the job also includes stationing of operating personel ( 2 No.)round the clock at the site including there boarding and lodgingfor providing uninterrupted power supply to theinstallation during poweroutages from the PDD Source.( Complete job) |
32 | Supply and filling of Diesel oil for running of D.G set including its storage in barrels. |
33 | Supply installationtesting and comm.ofMCCB of following rating along with sheet steel enclosureLegrand/Schenieder/ L&T make. 160 amp 4 pole 36 K |
34 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Anchor/ polycab make) single core cable in surface / recessed medium class PVC conduit ( excluding the cost of conduit), with modular switch ( Anchor roma urban/ Eq. make), modular plate, suitable GI/ PVC Heavy duty box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
35 | Supply, laying overhead, testing and comm. Of 16mm2 core 650/1100 V grade unarmoured Aluminium cable Havell/Polycab/Eq. standard make. |
36 | Taking of photographs ofsize 125mm x100mm Pre Execution, DuringExucation and PostExecutionto be submitted with bill complete Job. (Geo tagged photographs showingLongitude and latitude) |