Tender For Repair Replacement Of Sewer Line Network, Drain, Footpath, Fencing And Boundary Wall At Age Br-Ii Under Ge Dinjan, dinjan-Assam

Military Engineer Services-MES has published Tender For Repair Replacement Of Sewer Line Network, Drain, Footpath, Fencing And Boundary Wall At Age Br-Ii Under Ge Dinjan. Submission Date for this Tender is 27-05-2024. Footpath Work Tenders in dinjan Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43308932
Tender For Repair Replacement Of Sewer Line Network, Drain, Footpath, Fencing And Boundary Wall At Age Br-Ii Under Ge Dinjan
Open Tender
Indian
Assam
dinjan
27-05-2024

Tender Details

Repair Replacement Of Sewer Line Network, Drain, Footpath, Fencing And Boundary Wall At Age Br-Ii Under Ge Dinjan

Key Value

Document Fees
INR 500 /-
EMD
INR 74000.0 /-
Tender Value
INR 37 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF SEWER LINE NETWORK, DRAIN, FOOTPATH, FENCING & BOUNDARY WALL AT AGE B&R-II UNDER GE DINJAN
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depthfor foundation, pipeline etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
2Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in hard/dense soil complete all as specified and as directed.
3Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting pointcomplete all as specified and as directed.
4Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
5M&L for brick work using locally available first class bricks sub class "B" bricks (old size brick), straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
6Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc laid beded and pointed in any mortarcomplete all as specified and as directed.
7M&L for brick work with sub-class "B" bricks laid on flat, in floors bedded and jointed in CM 1 : 6 and pointed in cement mortar (1:6), complete all as specified and as directed.
8M&L for bricks, sub class B, laid on edge in drain bedded and jointed in cement mortar 1:6 and pointed in cement mortar (1:3),complete all as specified and as directed.
9M&L for PCC (1:2:4),type- B1 (using 20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs not provided , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed and specified
10Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
11M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete, etc complete all as specified and as directed.
12Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially porvided for RCC cover slab complete all as specified and as directed.
13S&F for mild steel TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
14M&L for mild steel TMT bars 6 to 8mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
15M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cover slab of drain, etc and set in cement mortar (1:4) including necessary formwork, moulds, etc complete all as specified and as directed. Note : Reinforcement shall be measuredand paid separately.
16Dismantling natural ground posts or struts in normal ground (wood,steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
17Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft and loose soil complete all as specified and directed.
18M&L for plain cement concrete (1:3:6),type C 2 (using 40 mm graded stoneaggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
19M&L for providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exceeding 100 and not exceeding 250 Sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops ascomplete all as specified and as directed.
20M&L for fencing post including embeding in concrete and screwing etc. wind ties, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165
21Taking down chowkats or frame, n. exc 1.5 sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.
22S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
23S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails.MS frame shall be covered with heat moulded, plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed by Engr-in-Charge.
24S&F for 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and as directed.
25S&F 150 mm long, aluminium handles, cast type, anodised complete all as specified and as directed.
26S&F 150 mm longaluminium, anodised barrel tower bolts of extruded section and fixed complete
27S&F in repairs 110 mm bore PVC (SWR) soil, waste and vent pipes single socketed, in any length with rubber ring joints laid in floors or trenches etc complete all as specified and as directed.
28S&F in repairs PVC (SWR) pipes type "B" 110mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
29S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
30S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
31S&Fin repairs PVC (SWR) branch piece single (single Y) 110mm bore with access door complete all as specified and as directed.
32S&F in repairs for 110 mm bore PVC (SWR) bends of any radius complete all as specified and as directed.
33S&F in repair 75mm dia, PVC (SWR) floor trap, plain with gratingincluding jointing with solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
34S&Ffor Gun metal gate valves with iron wheel headscrewed both ends for iron pipes or for unions for 20 mm bore pipes, complete all as specified and as directed.
35S&F in repairs, 20 mm bore,ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and as directed.
36Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing the rubbish off the premises complete all as specified and as directed.
37M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed.
38M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed.
39M&L for coloured glazed ceramic tiles in vertical surface of size 450X 300X 7 mm thick over 10 mm thick back coat of cement mortar in (1:4)set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
40M&L for machine pressed precast conctete interlocking paver block, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
41M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx20mm thick, as in floors etc,including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
42Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
43M&L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
44M&L for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
45Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 100/110 mm bore pipe complete all as specified and as directed by Engineer-in-Charge .
46Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 150/160mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
47Cutting into existing manholes for connecting new drains, making good to pipe and plastering the disturbed portions in CM 1:3 to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or ¾ round section) in cement concrete 1:2:4 type B-1 finished smooth and reforming benching as required for 200/225mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
48Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 150/160mm dia complete all as specified and as directed by the Engineer-in-Charge
49M&L for salt glazed stone ware drain pipes 150 mm bore, grade "A" laid in trenches, jointed and tested complete all as specified and as directed.
50M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed .
51Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 200/225mm dia complete all as specified and as directed by the Engineer-in-Charge
52M&L for salt glazed stone ware drain pipes 200 mm bore, grade "A" laid in trenches, jointed and tested complete all as specified and as directed.
53M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore SGSW/RCC drain pipes complete all as specified and as directed .
54S&Fin repairs, vitreous China squatting pan, "Orissa"pattern, size 580mm x 440 mm, white with integral foot rest and "P" or "S" trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications as specified.
55S&Fvitreous china Semi pedestal pattern (Anglo Indian type) whiteconnection to trap "P" or "S" and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing includingtaking down the existing old one all asspecified and as directed.
56S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain andflushing pipe, anti syphonic pipe including PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete (1:4:8) type D2 and to match with existing specifications complete all as specified and as directed.
57S&F in repairs vitreous china wash basin, size 550x400mm, white, flat back, including 32mm bore PVC (HDPE) waste pipe 450mm long, 32mm bore CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.
58S&F in repair 15 mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
59S&F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms) complete all as specified and as directed. .
60S&F in repairs flexible (coil shaped) PVC waste pipe for sink and wash hand basin 32/40mm dia, length not less than 70 cm, connected to PVC waste coupling/fittings complete all as specified and as directed.
61S&F in repairshealth faucet cast copper alloy with push button flexible steel pipe with PVC lining of 1 mtr long suitable for 15mm pipe,
62S&F in repair 600mmX450mm bevelled edge mirror of selected quality 5mm thick glass, mounted on PVC frame including key hole plates for hanging and fixed to wall with chromium plated cup washers and screws complete all as specified and as directed.
63Dismantlingwater tankscapacity exc 500 ltrs andn.exc 1000 ltrs and removing to store.
64Dismantlingwater tankscapacity exc 250 ltrs andn.exc 500 ltrs and removing to store.
65S&F for 500 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and as directed.
66S&F 1000 litres capacityrotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
67S&F in repairs,PVC low level flushing cistern, 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe andflush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed
68M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
69M&L for applying three coats of white wash on newly plastered surfaces incl preparation of surfaces complete all as specified and directed.
70Dismantlingnatural ground posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed..
71Dismantling fencing wire mesh, any type complete all as specified and directed.
72Dismantling mild steel work for barbed wire complete all as specified and directed.
73S&Fin repairs galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
74Supply only mild steel galvanised security chain link fencing of any size, any type and any dia, complete all as specified and directed.
75Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and directed..
76M&L in replacement of mild steel flat iron fillets for securing wire mesh etc. including all necessary drilling or riveting etc. and similar work conforming to Fe 290 (Gde E-165) complete all as specified and as directed.
77Restraing and resecuring including making good staples with chain link fening plain mild steel wire galwanised fixing to concrete, tying wire galvanised iron staple or steel pins(each line of wire to be measured).
78Attending of complaint by covering the following items of work :- (a) Cleaning and clearing of blocked IWCs and EWCs to sewage line upto 1st manholes by rodding or any other suitable method and taking out the muck, mud and other debris from WCs and the sewage line cleaning with fresh water & removing the debris upto a distance exceeding 200M and not exceeding 250M and covering the same with a layer of soil not less than 15cm thick complete all as specified and as directed by Engr-in-Charge. (b) Cleaning and clearing of blocked chocked floor trap in kitchen and bathrooms including gully trap, the waste water line connection etc by rodding or by any other suitable method and taking out the debris to a distance exceeding 200m & not exceeding 250m and covering the same with a layer of soil not less than 15cm thick and drain out the floors taps, gully traps waste pipe and soil pipe with fresh water etc complete all as specified and as directed. Note:-(i)Adequate number of workmen shall be deployed as and when complain received for immediate execution.If any complaint not attend by the contractor within a day then a sum of Rs. 50.00 will be recovered against per complain per day from the contractor. (ii)Rate quoted above shall be deemed to including the cost of adequate T&P, equipment, safety devices etc (iii) Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.
79Taking out liquid/solid content from manhole/ sump/ septic tank of any size any depth by super succer machine or high pressure pump, cleaning throughly including disposal of liquid/solid content out of the Cantt Area and covering with a layer of soil not less than 15cm thick complete all as specified and as directed.
80Cleaned blocked drain pipes (SGSW/hume pipe) up to 150mm bore by rodding from manholes and well flusing with water after cleaning the same all as directed and including disposing off the deposited sludge , etc inside pipes to a distance n.exc 200m, burried under ground (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around slope all complete as required and directed.
81All as per item No 81 here-in-before but exc 150mm and n.exc 250mm bore pipes complete as required and directed.
82All as per item No 81 here-in-before but exc 250mm and n.exc 450mm bore pipes complete as required and directed.