Military Engineer Services-MES has published Tender For Repair Maintenance Of Lt Switch Gear Control Panels, Mccb Feeder Pillar Box And Other Allied Works At Af Stn Memaura. Submission Date for this Tender is 25-05-2024. Switch Gear Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43308928
Tender For Repair Maintenance Of Lt Switch Gear Control Panels, Mccb Feeder Pillar Box And Other Allied Works At Af Stn Memaura
Open Tender
Indian
Uttar Pradesh
Lucknow
25-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair Maintenance Of Lt Switch Gear Control Panels, Mccb Feeder Pillar Box And Other Allied Works At Af Stn Memaura

Key Value

Document Fees
INR 500 /-
EMD
INR 19000.0 /-
Tender Value
INR 9.50 Lakhs /-

Attachment

FileName File Description File Size
4ceab57f-44a2-4a00-b3f5-22df3ee20a66.html Tender Notice 0 KB
BOQ_730331.xls Tender Document 0 KB
TENDER8338.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: Repair/ maint of LT switch gear, control panels, MCCB, feeder pillar box and other allied works at AF Stn Memaura.
Sl. No. Item Description
1Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed
2Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and as directed
3Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed.
4M&L sand cushioning 8cm below the cable and 15cm above the cable for cableprotection in trenches complete all as specified and directed. Note:- After cushioning total thickness measured as 18 cm.
5Supply and lay burnt best quality locally available old size sub class "B" bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
6Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed
7Taking out unserviceable LT U/G cable from trenches of size 6 Sqmm to 10 Sqmm 2 core complete all as specified and as directed.
8All as per item No- 7 here-in-before but size 16 Sqmm to 50 Sqmm4/3.5 core
9All as per item No-7 here-in-before but size70 Sqmm 3.5 core
10Supply, laying and testing ofLT cable 1100 volt grade XLPE insulatedunderground electric cable PVC bedded andsheathedsteel wire/strip armoured aluminum stranded conductor of size 10 Sq mm 4 core.
11All as per item No. 10 here-in-before but size of 16 Sqmm 4 core
12All as per item No. 10 here-in-before but size of 25 Sqmm 4 core
13All as per item No. 10 here-in-before but size of 35 Sqmm 4 core
14All as per item No. 10 here-in-before but size of 50 Sqmm 3.5 core
15All as per item No. 10 here-in-before but size of 70 Sqmm 3.5 core
16Relaying of existingserviceable undergroundcable of size 6 Sqmm to 10 Sqmm 2 Core obtained from item No - 7 complete all as specified and as directed.
17Relaying of existingserviceable undergroundcable of size 16 Sqmm 2/4 Core to 50 Sqmm 3.5 core obtained from item No - 8 complete all as specified and as directed.
18Relaying of existingserviceable undergroundcable of size 70 Sqmm 3.5 Core obtained from item No - 9 complete all as specified and as directed.
19M & L for cable route indicator for 1100 Volts grade cable with 150 mm dia cast iron plate circular or rectangular in shape of minimum 8 mm thickness welded with 35x35x4 mm angle iron mast 0.5 mtr from the GL including PCC foundation 1:3:6 type CI of size 30x30x45 cm and necessary earth work all as directed.
20Boring holeshorizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
21S&F in replacement of 50 mm bore GItubinglight grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified.
22S&F in replacement of 40 mm bore GItubinglight grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified.
23M&Lin replacement earthing complete with galvanised steel earth plate electrode 600x600x6.00 mm thick, burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal/coke and common saltupto 0.90 meter depth all around the earth plate and connected to earth leadof GI strip 25x4 mm by means of bolts, nuts, check nuts and washers of GI or steel and thimbles and other end of the earth wire connected to equipments/panels and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingcomplete all as specified and as directed. Note : 1. RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 50mm thick reinforced with XPM weighting not less than 4 KG/sqmmin lieu of CI cover. 2. Charcoal/coke and commonsaltupto 0.90 meter depth shall be filled in layers of 15 centimeters all around the earth plate. 3.On testing after completion of earthing if desired earth resistance is not achieved , the earthing will be redone at no extra cost to obtain the desired earth values.
24M & L for aluminium strip 25 x 3 .15 mm with base insulatorsand screws etc fixed on wall/ floorfor extension of earthing lead.
25Supply and fixing of sheet metal enclosure VTPN distribution board, Double door, AC, 440 volt, 04 way with 200 Amp rated copper bus bar and metal door with IP 54 and IK 09 protection alongwith cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing including one MCCB of 63 Amp rating, 04 pole, AC, 415 volt of 16 KA breaking capacity complete all as specified and directed.
26S & F MCB single pole 240 volts, "C" curve of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables.
27S & F MCB SPN 240 volts, "C" curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
28S & F MCB SPN 240 volts, "C" curve of rating 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
29S & F MCB TPN 240 volts, "C" curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
30Dismantling existing unserviceable feeder pillar box including disconnection from different sites .
31Supply, install, testing and commissioning of outdoor type cubical bus bar chamber 0.90 m x 0.60 m x 0.60 m suitable for 3 phase 4 wire 415 Volt, 50 Hz and, 415 Volt, having 160A MCCB, 4 pole, 415 volts, 50 Hz, 25 KA and 4 aluminium bus bar of suitable size and of capacity 250amp factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof. The outer shell shall be made out of 3.15mm thick CRCA Sheet (CPRI type tested) and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air.The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands.The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round.Provision o threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made, degree of protection of outer shell shall be IP-43 complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cum complete all as specified and directed.
32S & F in replacement MCCB 630 Amps, 4 pole, 415 volts, 50 Hz50 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sideswith existing size and make as suitable to fit in the existing LT FPB
33S & F in replacementMCCB 400 Amps, 4 pole, 415 volts, 50 Hz36 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sides with existing size and make as suitable to fit in the existing LT FPB
34S & F in replacement MCCB 320 Amps, 4 pole, 415 volts, 50 Hz36 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sideswith existing size and make as suitable to fit in the existing LT FPB
35S & F in replacement MCCB 250 Amps, 4 pole, 415 volts, 50 Hz36 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sideswith existing size and make as suitable to fit in the existing LT FPB
36S & Fin replacementMCCB 200 Amps, 4 pole, 415 volts, 50 Hz36 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sideswith existing size and make as suitable to fit in the existing LT FPB
37S & Fin replacementMCCB 160 Amps, 4 pole, 415 volts, 50 Hz36 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sideswith existing size and make as suitable to fit in the existing LT FPB
38S & Fin replacementMCCB 125 Amps, 3 pole, 415 volts, 50 Hz16 KA breaking capacitywith adjustable thermal magnetic release with spreader link on both sideswith existing size and make as suitable to fit in the existing LT FPB
39S & Fin replacement MCCB100 Amps , 3 pole, 415 volts , 50 Hz , 16 KAbreaking capacitywith adjustable thermal magnetic release, with spreader links on both sideswith existing size and make as suitable to fit in the existing LT FPB
40S & Fin replacement MCCB 63 Amps , 3 pole, 415 volts , 50 Hz , 16 KAbreaking capacitywith adjustable thermal magnetic release, with spreader links on both sideswith existing size and make as suitable to fit in the existing LT FPB
41M & L for cement concrete type C2 , 1:3:6 using ( 40 mm graded aggregate) in foundation of plinth protection including necessary form work all as specified and directed.
42M & L for cement concretetype B-1, 1:2:4using (20 mm graded aggregate) including formwork for coping of LT pole complete all as directed.
43M & L for preparation of old painted steel or iron surfaces of LT FPB of various size by scrapping with steel wire brush /scrapper emery paper etc and applyingone coat of synthetic enameledsiemens grey/exising colour( painting shall be done by spray machine) including welding theLT FPB door matching with the LT FPB complete all as specified and as directed.
44Excavation in post holes (or similar holes) each not exc. 0.5 Cum, getting out ,returning filling in and ramming earth or broken rubble mixed with eartharound, in layers n.exc. 25cm in soft/loose soil and getting out.
45S&F for mild steel plate girder or single stanchions or posts, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets cleats or other connections of Fe 410-W (Gde-E-250) quality "A"
46S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary,gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165(Brackets over 10 kg each to be measured under "Structural Steel")complete all as specified and directed.
47Supply, installation and fabrication in replacement of reflective information sign board, single sided of size 16 ft x 3 ft made out of 2 mm thick aluminium sheet, pasted with blue colour background reflective paper, digital printed white colour lettering including marking MES Logo symbols and all fixing arrangements like nuts, bolts & washers to fix the sign board complete all as specified and directed. (e.g. SUB STN B AGE (I) AF MEMAURA)
48S&F in replacement to ON Load Changeover Switch, Rotary type 63 Amp rating, 415 Volt, TPN, front operated with sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed. (Make: HPL/Havells/L&T or equivalent as Approved by AGE (I))
49S&F in replacement to ON Load Changeover Switch, Rotary type 200 Amp rating, 415 Volt, TPN, front operated with sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed. (Make: HPL/Havells/L&T or equivalent as Approved by AGE (I))
50S&F in replacement to ON Load Changeover Switch, Rotary type 320 Amp rating, 415 Volt, TPN, front operated with sheet metal enclosure suitable for mounting on existing panel as per sample and site requirement complete all as specified and directed. (Make: HPL/Havells/L&T or equivalent as Approved by AGE (I))
51S&F in replacement to OFF Load Changeover Switch, Side handle, 200 Amp rating, 415 Volt, TPN with sheet metal enclosure suitable for mounting on existing location as per sample and site requirement complete all as specified and directed. (Make: HPL/Havells/L&T or equivalent as Approved by AGE (I))