Tender For Repair/Maintenance Of Cattle Fencing, Security Fencing, Compound Wall, Path, Hardstanding, Drain And Other Connected Works Under Age B/R-I At Ge Nasirabad, nasirabad-Rajasthan

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Cattle Fencing, Security Fencing, Compound Wall, Path, Hardstanding, Drain And Other Connected Works Under Age B/R-I At Ge Nasirabad. Submission Date for this Tender is 23-05-2024. Drainage Tenders in nasirabad Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43307194
Tender For Repair/Maintenance Of Cattle Fencing, Security Fencing, Compound Wall, Path, Hardstanding, Drain And Other Connected Works Under Age B/R-I At Ge Nasirabad
Open Tender
Indian
Rajasthan
nasirabad
23-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maintenance Of Cattle Fencing, Security Fencing, Compound Wall, Path, Hardstanding, Drain And Other Connected Works Under Age B / R-I At Ge Nasirabad

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
0317f2bc-28b1-4629-8024-c571e0a9dac8.html Tender Notice 0 KB
BOQ_730142.xls Tender Document 0 KB
GeneralPages8441.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK : REPAIR/MAINTENANCE OF CATTLE FENCING, SECURITY FENCING, COMPOUND WALL, PATH, HARDSTANDING, DRAIN AND OTHER CONNECTED WORKS UNDER AGE B/R-I AT GE NASIRABAD
Sl. No. Item Description
1Demolition or stone/brick work built in cement mortar including pillars, arches, quoins etc but excluding not ashlars facing etc complete all as specified and directed by Engr-in-Charge.
2M&L for RandomRubblestone walling uncourses, built in CM (1:6) complete all as specified and directed by Engr-in-Charge.
3All as aboveitem No-2.00above but except stone complete all as specified and directed by Engr-in-Charge.
4Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface n. exc 20mm complete all as specified and directed by Engr-in-Charge.
5M&L forbrick work with sub class B bricks straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
6M&L forfly ash Brick work old size , straight or curved on plan to any radiusin half brick thick walls built in CM 1:4complete all as specified and directed by Engr-in-Charge.
7M & L for PCC 1:4:8 Type D2 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
8Taking down cement plastering of any description on brick / stone/ concrete wall / ceiling surfaces of any description incl racking out joints hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
9M&L for 15mm thick cement plaster on fair faces of bricks surfaces or concrete surfaces in CM 1:4 finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
10M&L for 15mm thick cement plaster on stone masonary surfaces or concrete surfaces in CM 1:4 finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
11M&L for rough cast plaster over 10mm thick cement plaster in cement mortar 1:4 on stone / brick masonary wall surfaces complete all as specified and directed by Engr-in-Charge.
12M&L for 75mm thick cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified and directed by Engr-in-Charge.
13M&L for 100mm thick cement concrete type B-1 1:2:4 (using 20mm graded stone aggregate) as in of flooringwithout using extra cement complete all as specified and directed by Engr-in-Charge.
14DemolitionStone slabs and tiles of any description or thickness in floors, aprons etc laid bedded pointed in any mortar complete all as specified and directed by Engr-in-Charge.
15M&L18-20 mm thick granite ( of any type ) work(table rubbed and polished) in steps, jambs, pillars window cills, cooking platform and like in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-Charge.
16Dismantling of fencing wiremesh ,any type complete all as specified and directed by Engr-in-Charge.
17Dismantling posts or struts (steelor RCC) of any section embeded in concrete, includingtaking out embeded portion and preparing post holes for providing new posts in any type of soil complete all as specified and directed by Engr-in-Charge.
18M&L for PCC 1:3:6 , type C-2, using 40mm graded crushed stoneaggregate as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
19M&L for MS work for fencing post /gates and struts made from angle iron and flat iron in any section including cutting tops to shape , drilling holes and notching for fixing of wires etc confirming to Fe -290 or Fe -330 complete all as specified and directed by Engr-in-Charge.
20S & F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with andprovision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)complete all as specified and directed by Engr-in-Charge.
21Supply only chain link MS galvanised fencing ,any size or type complete all as specified and directed by Engr-in-Charge.
22Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed by Engr-in-Charge.
23Supply and fixing for 3.15 mm dia galvanised medium coated as per IS 4826 steel wire as required for fixing chain link fencing etc complete all as specified and directed by Engr-in-Charge.
24M&L for5 to 10mm dia mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends each screwed endto be fitted with washers etc complete all as specified and directed by Engr-in-Charge.
25M&L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
26M&L for preparation of new plastered surface of walls and applying two coats of cement base paint complete all as specified and directed by Engr-in-Charge.
27Demolition of cement concrete (unreinforeced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed by Engr-in-Charge.
28M & L for PCC 1:2:4 Type B0 using 12.50 mm graded aggregate as in coping, edging rounded or chamfered type etc complete all as specified and as directed by the Engineer-in-Charge.
29M&L in repair precast cement concrete louvers and jallies 35 mm thick made in Mix 1:2:4 type B0 using 12.5mm graded stone aggregate set in cement mortar 1:4andjallies design as per site requirementcomplete all as specified and directed by Engr-in-Charge.
30Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in hard/dense soil, complete all as specified and directed by Engr-in-Charge.
31Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil, complete all as specified and directed by Engr-in-Charge.
32M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
33M&L for chequered cement concrete tiles ((Endura tile) 30cm x 30cm x 10-12 mm thick, set jointed and pointed in neat cement slurry in floors with grey cement and pigments over 15 mm screed bed in CM mortar 1: 6 complete all as specified and directed by Engr-in-Charge.
34Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engr-in-Charge.
35Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engr-in-Charge.
36Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed
37M&L for cement concrete Type C2 1:3:6 (40mm graded stone aggregate) in surface channels and drains complete all as specified and directed by Engr-in-Charge.
38Total in Figures
39Quoted Amount in Words
Disclaimer :