Military Engineer Services-MES has published Tender For Provision Of Hot Water Boiler At 15 Care And Maintenance Unit (Kargil) Under Ge (Af) Leh. Submission Date for this Tender is 25-05-2024. Boiler Supply Tenders in kargil Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43305770
Tender For Provision Of Hot Water Boiler At 15 Care And Maintenance Unit (Kargil) Under Ge (Af) Leh
Open Tender
Indian
Jammu And Kashmir
kargil
25-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of Hot Water Boiler At 15 Care And Maintenance Unit (Kargil) Under Ge (Af) Leh

Key Value

Document Fees
INR 500 /-
EMD
INR 81300.0 /-
Tender Value
INR 40.65 Lakhs /-

Attachment

FileName File Description File Size
80774498-908b-4c66-a606-0b5770423a4c.html Tender Notice 0 KB
BOQ_730243.xls Tender Document 0 KB
drg.pdf Tender Document 0 KB
tenderdoc.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : PROVN OF HOT WATER BOILER AT 15 CARE AND MAINTAINANCE UNIT (KARGIL) UNDER GE (AF) LEH
Sl. No. Item Description
1Excavating in post holes (or similar holes) each n.ece 0.50 cu.m getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not excedding 25cm in hard/dense soil Complete all as specified and directed.
2M& L For Cement concrete 1:2:4, type B - 2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete in post holes etc.Complete all as specified and directed.
3S&F mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of grade steelFe - 410 W ( Gde E -250) quality B complete all as specified & directed. Note : Steel frame work willinclude post, truss, purline, rafter, runner, bracings etc.Complete all as specified and directed.
4S&Fmild steel plates (plain or chequered) Channels, square cut or notched (ordinary or counter sunk) forming hole, without any attachment of grade Fe - 410 W ( Gde E -250) quality B complete all as specified & directed.
5S&F mild steel Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165Complete all as specified and directed.
6S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsComplete all as specified and directed.
7S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsComplete all as specified and directed.
8M&L for preparation of new steel of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of primerComplete all as specified and directed.
9Surface dressing n exc 15 cm deep and getting out in hard/dense soil Complete all as specified and directed.
10M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface Complete all as specified and directed.
11M&L for 100 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) Complete all as specified and directed.
12M&L for 100 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) Complete all as specified and directed.
13M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’, thickness of slab 100mm Complete all as specified and directed.
14M&L Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade "A" Complete all as specified and directed.
15M&L surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil, Complete all as specified and directed.
16Removing excavated soil to a distanceexceeding 1Km but n.exc 5.0Km and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge.
17Supply, fixing, commissioning and testing of hot water generator capable of delivering a heat output 50,000 KCal/Hrusing HSD oil with out let temp 90-95 degree Celsius and efficiency more than 90% , Horizontal (skid mounted), smoke tube, reverse flame with min 03 Nos of passes with flow rate of 2500 LPH, working pressure 6 Kg/cm2. The inner shell shall be made of carbon steel and outer shell shall be made of Mild steel,front and back door shall be lined withhigh grade insulation and refractory, Pressure relief valve, in/out pressure gauge with ball valve, Inlet and Outlet temperature controller, Pressure Switch, Water and flue high temperature cut out, Hour-meter complete in all respect, including following item of work: (a) Heater unit : Heat exchanger horizontal (skid mounted), smoke tube, reverse flame, consisting of closely wound, helical, concentric coils, arranged to give 03 No of passes on flue gas and made ofcarbon steel confirming to BS 3059, PART-I, ST 320, ERW), suitable for high temperature all as per manufactures design. (b) Pressure jet burner : Highly efficient with low noise, Suitable for light oil firing with steeples modulation mechanism all as per manufactures design and of required head and capacity. (c) Combustion air fan with drive motor assembly all as per manufactures design and of required head and capacity. (d) Control Panel: Dust protected control panel made of 2 mm thick CRCA sheet finished with baked enamel paint, prewired with main incomer, indicator lights, hours meter, relay, fault indicating lights such as high temp of water, burner trip at high temperature of flue gasses with audioalarm , burner management system, switchgear consisting of contractor overload relays, fuses and MCBs etc, all as per manufactures design and of required capacity. (e) Circulating pumps. Centrifugal water circulating pumps suitable for high temperature operation coupled with electric motor drive, mounted on common base frame all as per manufactures design and of required head and capacity. ( Capacity of pump should not be less than 2 HP ) (f) Fuel Pump: Fuel pump of suitable capacity with drive motor assembly for topping of diesel from barrel to diesel tankall as per manufactures design and of required head and capacity.
18(g) Oil Line: With duplex filters on fuel line at the inlet of fuel pump. Y strainer on fuel line between fuel pump and burner, non return valve on fuel pump outlet and bypass line, non return valve on modulation and circulation line, fuel oil regulation valves for burner modulation, burner solenoid valve, fuel oil pressure gauge at burner inlet, fuel pressure gauge on bypass line etc all as per manufacture design and required heat and capacity. (h) Burner( monoblock) with high efficiency programmed with matching flame sensor with On/Off ( one stage) control complete all as specified and as recommended by OEM ). (j) Hooter mounted on control panel for audible safety alarm all as per manufacture design NOTE:-1. All interconnections of water lines between storage tank , boiler units, fuel lines interconnection including necessary fittings/ accessories with in plant room is deemed to be included in scope of work and dimension of all parts are as per recommendation of approvedOEM. 2. Before starting the work contractor will submit the complete drawing /design and technical specification /data of Govt/ Public Sector approved OEM for approval of GE / Accepting Officer 3.The water storage meter shall meet all the relevant IS provisions/ extant codal provisions. Suitable safety arrangement shall be provided for safe operation of the equipment. 4. Anything missed above but technically requires for efficient operation is deemed to be included in the quoted rates.5. PCC foundation as per the manufacturer specifications shall be provided and the rates are deemed to be included in the quoted rate.
19Supply & fixing Chimney for exhaust of burnt smoke of minimum diameter 100mm diaand length 8 meter , fabricated of B class MS Black pipe conforming to IS 1239 ( Part-I)including canopyat the outlet of the chimney, flange to fix the chimney with the space heater complete all as specified anddirected.
20Supplyand installation of Diesel fuel storage tank of capacity 500 ltr made out of 5mm thick MS sheet complete with supply arrangement for topping up of service tank including lifting pump set suitable and provn of staging for diesel tank, ladder and transparent riser tube for diesel level indicator and control/drain valves complete all as specified anddirected.
21Supply and installation water Pumping sets,2 HP ( 1.5 KW) centrifugal, electric driven, 3 phase, 415 volts of suction x delivery (65x50mm) , 3000 RPM Head 14-16 Mtrs and discharge capacity 426-240 LPM complete including electrical connections, vibration padding & PCC foundation as per manufacturer recommendationcomplete all as specified and directed.
22Supply and fixing Steel water tubing 15mm dia medium grade galvanised ( ISI marked) with and including all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), Complete all as specified and directed.
23Supply and fixing Steel water tubing 20mm dia medium grade galvanised ( ISI marked) with and including all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), Complete all as specified and directed.
24Supply and fixing Steel water tubing 25mm dia medium grade galvanised ( ISI marked) with and including all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), Complete all as specified and directed.
25Supply and fixing Steel water tubing 40mm dia medium grade galvanised ( ISI marked) with and including all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), Complete all as specified and directed.
26Supply and fixing Steel water tubing 50mm dia medium grade galvanised ( ISI marked) with and including all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), Complete all as specified and directed. Note for item No. 21 to 25:-The GI pipe shall be laid below the frost line as applicable in Kargil area and as stipulated in relevent IS or as directed by Engineer-in-Charge
27Supply and fix gun metal, gate valves of 25mm dia ISI marked, with iron wheel head, screwed both ends for GI pipe ,Complete all as specified and directed.
28Supply and fix gun metal, gate valves of 40mm dia ISI marked, with iron wheel head, screwed both ends for GI pipe ,Complete all as specified and directed.
29Supply and fix gun metal, gate valves of 50mm dia ISI marked , with iron wheel head, screwed both ends for GI pipe ,Complete all as specified and directed.
30Design and installation forcold Water storage tank of capacity 5000 Ltrs, fabricated out of 5mm thick MS sheet/plate for shell and end plate complete with inlet cold water from water supply installation flanges welded at proper places to suit equipment/system feeding system and man hole of 600mm dia with neck raised to 200 mm and provided with welded MS flange 10mm thick with drilled holes and top lid of 10 mm thick with hole nuts, bolts washers and 6mm thick gasket, painted with 2 coatsof anticorrosive paint over a coat of red oxideincluding provision of PUF Insulation of 50 mm thick with40kg/m3 density including 26SWG plain Aluminium cladding for steel tank complete all as specified and as directed.
31Lagging to pipe line of size 50 mm bore used in external water supply or plumbing all round with,50 mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 including provision of chicken mesh wire netting 25 gauge, 20mm mesh and along with 0.01 mm thick aluminium foil wrapped around with provision of screw or any material required at site complete all as directed.
32Lagging to pipe line of size 40 mm bore used in external water supply or plumbing all round with,50 mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842.including provision of chicken mesh wire netting 25 gauge, 20mm mesh and along with 0.01 mm thick aluminium foil wrapped around with provision of screw or any material required at site complete all as directed.
33Lagging to pipe line of size 25 mm bore used in external water supply or plumbing all round with,50 mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842.including provision of chicken mesh wire netting 25 gauge, 20mm mesh and along with 0.01 mm thick aluminiuum foil wrapped around with provision of screw or any material required at site complete all as directed..
34Lagging to pipe line of size 20 mm bore used in external water supply or plumbing all round with,50 mm thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842.including provision of chicken mesh wire netting 25 gauge, 20mm mesh and along with 0.01 mm thick aluminiuum foil wrapped around with provision of screw or any material required at site complete all as directed.
35S & F cast iron air release valves with single air outlets, conforming to IS 14845-200 of size 50 mm dia bore and fixing up in cast iron water supply mains of size 50mm diacomplete all as specified and directed.
36S & F reflux valves with by pass arrangement of size 50mm dia, conforming to IS 5312-2004 (Part-I)complete all as specified and directed.
37S & F Y strainer SS ISI marked conforming to relevant IS of size 50mm dia, complete all as specified and directed.
38Material and labour for construction of valve chamber of size120x 120 x 120 cm deepdimensions (Over all internal dimension)with PCC foundation, random rubble uncoarsed stone masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:- Valve chamber shall be provided with the following specifications:- (i) Cement concretefor foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thickextended up to 150 mm beyond the outer face of block masonry.(ii) Walls of valve chamber 230 mm thick withrandom rubble uncoarsed stone masonry walls using block masonry setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth.(iv)50 mm thick coping in PCC 1:3:6 type C1 over masonry wall.(v) Chamber cover shall be of 6 mmthick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. Steel surface shall be painted with two coats of synthetic enamel paint of first quality over one coat of red oxide primer complete all as specified and directed
39Material and labour for LT distribution panel, made out of 2.00 mm thickCRCA sheet, powder coated, dust & vermin proof, IP-66 Protection, Indoor type factory made cubical totally enclosed type with front and rear door opening as per engineering practice provided with locking arrangement for opening of panel with provision of separate chamber in upper part to enclose copper busbar of cap 200 Amps 3 pole and neutral on epoxy suitable insulators in horizontal position and stepped manner with min 20cm distance between busbars & panel body and 06 Nos separate chambers of adequate size embedded in 40mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), on angle iron of size 50x50x6mm with footing 30 cm clear space between bottom of panel and flooring including all accessories prewired with insulated copper wires of suitable size.The panel shall compromise of the following fittings and fixture: INCOMMING (a) MCCB 63 Amps, 16 KA 4 pole with fixed typethermal and magnetic settings - 01 No (b) Phase Indicating lamps Led type (RYB). (c)Voltmeter (0-500V) range with selectorswitch-01 Set (d) Ameter ( 0-500 A) range with CTs of 100/5 ratio with selector switch - 01 NoOUTGOING (e) MCB TPN 40 Amps 10 KA- 02 Nos (f) MCB SPN 40 Amp- 3 Nos(g) Single phase preventer for each outgoing - 02 Nos (h) Star Delta Starter for motor upto 5 HP-02 Nos.
40M&L for point wiringfor one light point/fan point/bell/buzzer controlled by one way switch point 5 Amp complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and fittings such as tees, bends, elbow, reducers including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and including Metal flush box of suitable size for fixing modular switches/sockets/fan regulator etc , with and including Modular cover plates of suitable sizeand making good surface as per existing specification by plastering, white wash/colour and distemper etc complete all as specified and directed
41All as per item No.39 here-in-before but one socket outlet point 5 Amp on the same board complete all as specified and directed
42All as per item No.39here-in-before but one socket outlet point 5 Amp on the independent board complete all as specified and directed
43All as per item No.39 here-in-before but with 2.5Sqmm FRLS copper wire with 1.5Sqmm FRLS copper earth wire for 15Amp light point, complete all as specified and directed Note:- The point wiring for power point shall not be mixed with light/fan point circuit or not in same conduit pipe.
44Supply and fixing Switch piano flush type, single pole, one way, 5/6 Amps complete all as specified and directed
45Supply and fixingsocket two-in-one, 5 pin, 5/6 Amp universal type complete all as specified and directed
46Supply and fixing Switch16Amp,single pole one way complete all as specified and directed.
47Supply and fixingsocket out let 6/16Amp, flush type complete all as specified and directed
48Supply and fixing Distribution Boarddouble Doormade out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 08 way, 240 volts with bus bar rating 200 Amps including dust and vermin proof and making all necessary connections complete all as specified and directed.
49Supply and fixing Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as per existing specification by plastering and whitewash/ colour/ distemper etc complete all as specified and directed.
50Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.all as directed. Make :- PHILIPS Cat Part No. BRP 052 LED 045 CW SLMR FG S1 PSU GR or equivalent in Cromptton Greaves/bajaj/Havells
51Supply and fixing ofsecurity light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 25 mm dia for mounting on wall /shedlight grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
52Supply and fixing LED lights fitting 1x 22 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as directed Make :- PHILIPS Cat Part No. BN 021 LED22S PSU CW GR or equivalent in Cromptton Greaves/bajaj/Havells
53M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of plate not less than 1.5 M below normal ground level, connecting to the Galvanised iron earth strip 25x4mm size by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI light grade pipe 40mm bore including provision of concrete pit in PCC (I:2:4) type B-1 using20mm graded stone aggregated with 40mm thick cover of RCC (1:2:4)reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipefor watering, perforated at bottom and connecting to earth test point complete all as specified and directed.
54Supply andfixing 25mmx4mm GI strip on surface or in recesses for earth connections etc complete all as specified and directed.
55Supply, laying and testing LTcable XLPE insulated ISI marked, PVC sheathed, galvanised steel strip / wire armoured, aluminium conductor, 1100 volts grade, of size 10 Sqmm 4 core suitable for earthed system laid in duct / trench / along pole / wall etc including making connection complete all as directed. Note : 1. The cost of aluminium thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. The excavation, earth work, sand cushioning andprotection cover etc will be measured and paid separately under respective items.
56Supply, laying and testing LTcable XLPE insulated ISI marked, PVC sheathed, galvanised steel strip / wire armoured, aluminium conductor, 1100 volts grade, of size 25 Sqmm 4 core suitable for earthed system laid in duct / trench / along pole / wall etc including making connection complete all as directed. Note : 1. The cost of aluminium thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. The excavation, earth work, sand cushioning andprotection cover etc will be measured and paid separately under respective items.
57Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge.
58Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge.
59Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge.
60M&L for sand cushioning to under ground cable provided with layers of sand(8 cms deep before laying the cable and 15 cms deep after laying) complete allas specified and directedat site by Engineer-in-Charge.
61M&L for un-reinforced precast concrete cable cover, class LV, type 1, flat of size 300 x 180 x 40 mm for cable protection ISI markedcomplete all as specified and directed by Engineer-in-Charge.
62S&F MCB SPN 40-63 Amp, 10KA, C curve complete all as specified and directed by Engineer-in-Charge.
63S&F MCB SPN 6-32 Amp, 10KA, C curve complete all as specified and directed by Engineer-in-Charge.