Tender For Repair And Maintenance Replacement Of Security Light Garden Light Post Top Luminaries Solar Light Flood Light Bollard Light Glow Sign Board With Allied Services Under Ge West Mathura, mathura-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Replacement Of Security Light Garden Light Post Top Luminaries Solar Light Flood Light Bollard Light Glow Sign Board With Allied Services Under Ge West Mathura. Submission Date for this Tender is 01-06-2024. Halogen Light Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43299475
Corrigendum : Tender For Repair And Maintenance Replacement Of Security Light Garden Light Post Top Luminaries Solar Light Flood Light Bollard Light Glow Sign Board With Allied Services Under Ge West Mathura
Open Tender
Indian
Uttar Pradesh
mathura
01-06-2024

Tender Details

Tender For Repair And Maintenance Replacement Of Security Light Garden Light Post Top Luminaries Solar Light Flood Light Bollard Light Glow Sign Board With Allied Services Under Ge West Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-May-2024 Amendment01 Other 25-05-2024
2 25-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work : REPAIR / MAINT / REPLACEMENT OF SECURITY LIGHT / GARDEN LIGHT / POST TOP LUMINARIES / SOLAR LIGHT / FLOOD LIGHT / BOLLARD LIGHT / GLOW SIGN BOARD WITH ALLIED SERVICES UNDER GE (W) MATHURA
Sl. No. Item Description
1Dismantling & taking down unserviceable security light / garden light / flood light / post top light fitting of any Wattage / type from existing location / pole / building from height not more than 8.0 Mtr from ground level complete all as specified and directed by Engineer-in-charge.
2Supply & fixing of LED post top lantern in tycoon (Tycoon) shape, 70 Watt, IP -65, Impact resistance - IK07, colour temp- 3000 K, Class I, elegantly designed die-cast aluminum housing with heat sink for efficient thermal management, sturdiness and excellent corrosion resistant. aluminium canopy with classic design to enhance the aesthetic of the fixture, 02 nos die-cast aluminum arms & aluminium die cast spigot provided to support the housing & epoxy powder coated black after phosphochromate treatment, high efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >155 lm/W to ensure better uniformity of light distribution, powered by built-in, isolated potted electronic LED driver with APFC (SMPS based constant current supply) with lower THD, Output Short / Open Circuit protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other reliability test as per IS 15885 Part- 2/Sec 13 suitable for pole mounting with outer dia 76 mm with 3 nos allen screws M8x16 mm complete in all respect as specified & as directed.
3Supply & fixing of LED security / street light, 90 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class I in Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatmentHigh efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13. Suitable for bldg/pole mounting alongwith single arm bracket OD 58 mm (max) with suitable reinforcement on wall height complete in all respect & as directed.
4Supply & fixing of LED street light, 60 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatmentHigh efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13. Suitable for bldg/pole mounting alongwith single arm bracket OD 58 mm (max) with suitable reinforcement on wall height complete in all respect & as directed.
5Supply & fixng of LED security / street light, 45 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class I in Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatmentHigh efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13. Suitable for bldg/pole mounting alongwith single arm bracket OD 58 mm (max) with suitable reinforcement on wall height complete in all respect & as directed.
6Supply & fixing of LED Flood light, 100 Watt, IP - 66, Impact resistance - IK 07, colour temp- 5700 K, Class I in epoxy powder coated die-cast aluminium housing (ADC 12) in grey finish with aesthetically designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. M16 size gland is used for cable entry and provision for loopin-loopout.High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W and viewing angle of120° to ensure better uniformity. PC Lens with Asymmetric/symmetric light distribution and Toughened glass fixed to housing with 06 Nos screws. Integral electronic LED driver with APFC,lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV with built In SPD & other safety test as per IS 15885 Part-2/Sec 13 for wall or surface mounting using adjustable MS cradle of thickness 4 mm with SS angular dial for precise angular mounting of luminaire including neccessary PCC work reqd to make foundation base to install the luminaires complete in all respect & as directed.
7Supply & fixing of solar LEDpost top, 25 Watt with built-in solar panel having high efficiency poly crystalline solar PV modules, made of elegant looking die cast aluminum body with IP 65 protection, colour temp 5700 K,having Lithium battery with expected life of 1000 cycles and backup for 3 days with charge controller and remote control to select 32 lighting mode alongwith anchor fastener/bolt to install the luminaires complete in all respect & as directed.
8Supply & fixing of LED gate light, 30 Watt IP 65 die cast aluminium spigot for mounting LED driver and spun aluminium conopy which is painted white inside epoxy powder coated mattle black finish after phosphochromate treatment complete in all respect & as directed
9Supply & fixing of LED Spike light 10/12 watt, IP 65 in pressure die cast aluminium housing best suitable for bush lighting complete all as specified and directed
10Supply & fixing of LED Bollard light 10watt, IP 65 aesthetically designed landscape luminaire for diffused lighting suitable for architectural outdoor lighting typically giving off light from all sides best suitable to illuminate walkways, steps or pathways complete all as specified and directed
11Supply & fixing in replacement of cast aluminium architectural designer pole of designer leg and broader designer base finished with polyurethane paint (with prior treatments) diameter of approx 88mm, outer dia for spigot entry 75mm, 03 Nos T shaped bolts with nuts & washers provided for concrete foundation, total length of the pole including base and legs (base with plate x 4 Nos legs) is 3100mm (10 feet 2 inch) including J type foundation bolts and neccessary PCC work in (1:2:4) type B0 with curing for 7 days as reqd to install the pole complete in all respect & as directed.
12Supply & fixing in replacement of aluminum conductor wire with FRLSH insulated, PVC round sheathed, flexible bright annealed copper conductor cable of size 4.0 Sqmm, 3 core of voltage grade upto 1100 volt as per IS 694/1990 with latest amendments complete in all respect and as directed.
13Supply & fixing in replacement of aluminum conductor wire with FRLSH insulated, PVC round sheathed, flexible bright annealed copper conductor cable of size 2.5 Sqmm, 3 core of voltage grade upto 1100 volt as per IS 694/1990 with latest amendments complete in all respect and as directed.
14Supply and laying in replacement of Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade, size 25 mm dia including all fittings like bends, elbow reducer, junction, couplerboxes, tee bell mouth etc for protection of cables/wires complete in all respect as specified and directed.
15Supply and layingin replacement of light grade galvanised iron pipe 25 mm nominal bore dia size confirming to IS 1239-Part I, laid under the road, hard standing or through wall, pole for protection of cable complete all as specified and directed.
16Supply & fixing in replacement of worn out MCB enclosure with automatic street light control system with optical Micro Sensor to sense automatic switching ON at dusk (< 60 lux ) andswitching OFF at dawn (> 10 lux) with part night operation facility of minimum 4 to 8 Hrs with a resolution of ½ hour, Low voltage / High voltage trip protection and auto reset, operating voltage 150 - 280V AC, 50 HZ with enclosure made of UV stabilized, FR grade special moulding compound to provide a rust proof, electric shock proof, termite proof, outdoor type enclosure of IP 54 protection, MCB of current rating 40 Amps and contactor of rating 25 Amp ( AC 3) suitable to control the load of 5.0 KW, single phase load with necessary clamping arrangements including making incoming and outgoing cable connections complete in all respect and as directed.
17Cutting & Chasing required on concrete block/brick wall/path tile /floor etc not exceeding 10 cm girth to concealed the cable/GI wire and making good to disturbed surface with cement mortar (1:3) including facing / finishing where as requiredto match with existing surfacescomplete all as specified and directed.
18Supply & fixing LED luminaire 600x600mm, 36W (warm white with temperature 2700K/3000K), 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as directed.
19Supply & fixing LED luminaire 600x600mm, 36W (warm white with temperature 2700K/3000K), 220 Volts AC mounting type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete all as directed.
20Supply & fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
21Supply & fixing round shape 18 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
22Supply & fixing square shape 18 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
23Supply & fixing square shape 18 watt 220 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
24Supply, fixing, connecting & testing PIR movement detector sensor conforming to IEC-60669-1 & 2, single lens, angle of detection 360 degree, 1 channel, surface/flush mounted, diameter of floor detection range of 7m X 7 m, adjustable brightness level-05 to 1000 Lux, rated/operating voltage -230 volts 16 AAC 1, +10%/-15%, 50 hz, lightning output operating time-05 sec to 15 minute, operating temp 0 to 45 degree C, mounting on ceiling mounted bracket (if required) suitable for LED light load upto 1000 Watt for automatic switching ON/OFF of lights by detecting movement/presence of human & natural light within its range/zone with IR remote accessory complete in all respect complete all as specified and directed.
25Supply, fixing, connecting & testing PIR movement detector sensorfor corridor area conforming to IEC-60669-1 & 2, single lens, angle of detection 360 degree, 1 channel, surface/flush mounted, diameter of floor detection range of 20 m X 4 m, adjustable brightness level-05 to 1000 Lux, rated/operating voltage -230 volts 16 AAC 1, +10%/-15%, 50 hz, lightning output operating time-05 sec to 15 minute, operating temp 0 to 45 degree C, mounting on ceiling mounted bracket (if required) suitable for LED light load upto 1000 Watt for automatic switching ON/OFF of lights by detecting movement/presence of human & natural light within its range/zone with complete in all respect as specified & directed.
26Supply & fixing in replacement 60 W LED lamp with a unique design, integrating LED technology and motion detector for energy savings detection range 12 m, weather proof IP 55, day light sensing, angle of detection 0-360 degree, min luminous flux 3400 lm complete all as specified and directed.
27Supply & fixing in replacement 15 W LED lamp cool light with a unique design, integrating LED technology and motion detector for energy savings detection range 12 m, weather proof IP 55, day light sensing, angle of detection 140degree, min luminous flux 1100 lm complete all as specified and directed.
28Supply & fixing in replacement sheet metal 2 way with MCB SPN 20/25 Amp including bus bar 40 Amp complete for control of external lightingsystem with connection, testing and commissioning complete all as specified and directed.
29Supplying, laying, jointing, commissioning and testing XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes or other places etc complete including taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i)Excavation, earth work, sand cushioning, cable protection and GI pipe if required shall be measured & paid for separately under respective items of BOQ. (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
30Supplying, laying, jointing, commissioning and testing XLPEinsulated screened PVC bedded, armoured,heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 16 sq mm 4 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes or other places etc completeincluding taking down old unserviceable cable complete all as specified and directed by Engineer-in-charge. Notes :- (i)Excavation, earth work, sand cushioning, cable protection and GI pipe if required shall be measured & paid for separately under respective items of BOQ. (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
31Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or layingunderground cable and water supply / sewage pipe line etc.in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
32Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
33Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
34M&L for sand cushioning and covering clean and dry sand to underground electric cable in trenches / floor complete all as specified and directed. Note :- Punned thickness shall be measured and paid for.
35Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail