Tender For Day To Day Complaints Of Internal Elect Supply, Electric Meter, Solar Water Heating System, Lightening Conductor And Allied Works At Nams, Amritsar-Punjab

Military Engineer Services-MES has published Tender For Day To Day Complaints Of Internal Elect Supply, Electric Meter, Solar Water Heating System, Lightening Conductor And Allied Works At Nams. Submission Date for this Tender is 24-05-2024. Electrical Maintenance Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43297656
Corrigendum : Tender For Day To Day Complaints Of Internal Elect Supply, Electric Meter, Solar Water Heating System, Lightening Conductor And Allied Works At Nams
Open Tender
Indian
Punjab
Amritsar
24-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Day To Day Complaints Of Internal Elect Supply, Electric Meter, Solar Water Heating System, Lightening Conductor And Allied Works At Nams

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-May-2024 Tender corrigendum Other 24-05-2024
2 15-May-2024 Revised BOQ BOQ 24-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
69bba21b-b68e-4e00-9be7-13d97831e251.html Tender Notice 0 KB
15T.pdf Tender Document 0 KB
BOQ_730038.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : REPAIR/MAINT OF LT OH LINES, UG CABLES AND ALLIED WORKS AT NAMS
Sl. No. Item Description
1Attending of day to day electrical complaints pertaining to internalelectrification received through telephone/ Armaan or in person on detailment at MES Service centre located at NAMS Areaby locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc complete and carrying out repairs to the extent of tightening of loose connections, disconnection anddismantling of faulty wires, battens, conduits, boxes, main switches, MCB"s, DB"s and other E/M fixturesincluding providing necessary screws / nuts / bolts / nailsfor the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. Note - (i) Cost of labour for the fixing/replacement of unserviceable item shall deemed to be included in item no 2 and cost of store replaced shall be measured as supply only against relevant Items.
2(ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB"s/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement oftwo fixtures in one Qtr will also be measured and paid as one complaint. (iii) Replacement of more than two fixtures/itemsbut multipleof three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint. (iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion. (v) Necessary tools for tradesman shall be provided by the contractor. (vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor. (vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent naturei.e no light, short circuit, earth fault etc shall be attended immediately onreceipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below
3(ix) Requiring stores i.e switchs and sockets, fan regulator, bell push, metal flush box, lamp holder, bell ding dong of modular and non modular shall be issued by department for fixing only. (x) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit. (xi) Electrician will report to AGE EM complaint cell at 9 O"Clock daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report. (xii) Contractor deploy local electrician for the job so that urgent nature of complaintlike no light, short circuit and earth fault will also done on Holidays/ Sunday.(xiii) The contractor will deploy 4 nos electrician and 2 nos geyser mechanic throughout the contract irrespective of no of complaint received.(xiv) For Non attending of urgent nature complaint within 24 hours a penalty of 100 RS/per day/per complaint will be levied on contractor.
4Supply only in replacement switch piano flush type 5 AmpsOne-way, AC 230V on existing switch board all as specified and as directed.
5Supply only in replacement of switch piano flush type15 Amps single pole one-way,230V complete all as specified and as directed.
6Supply only in replacementswitch piano type two ways AC 230 volts6 Ampsas per on existing switch board .
7Supply onlyin replacement socket out let 2-in-1,3 Pin 6 Amps flush type 230 volts complete all as specified and as directed.
8Supply onlyin replacement socket outlet, flush type, 2-in-1, 3 pins, 6 & 16 Amps multipurpose complete all as specified and as directed.
9Supply only in replacementbell push switch piano, flush type, 5 Amps complete all as specified and as directed.
10Supply only in replacement of bell ding-dong230 volts, single phase complete all as specified and as directed.
11Supply only in replacement of ceiling rose 65x50mm two to three terminals AC 230 volts complete all as specified and directed of any make/model as per in existing building.
12Supply only in replacementbatten type angular/ Batten lamp holder insulated body with back plate suitable for batten fitting including PVC round block complete all as specifed and as directed.
13S&Fin replacement MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of "B" series in distribution boards all as specified.
14S&F in replacementMCBs single pole and neutral (SPN) 32 Amps with 10 KA breaking capacity of "B" series in distribution boards all as specified and directed.
15S&F in replacementMCBs single pole and neutral (SPN) 40 to 63 Amps with 10 KA breaking capacity of "B" series in distribution boards all as specified and directed.
16Supply only in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
17Supply onlyin replacement plug top 3 pin, 5 Ampscomplete all as specified and as directed.
18Supply only in replacement plug top 3 pin, 15 Ampscomplete all as specified and as directed.
19Supply onlyin replacement LED Tube rod with polycarbonate diffuser 4 feet long of capacity 18 watts complete with all accessories baseall as specified & directed by Engr-in-Charge.
20Supply onlyin replacement LED Tube rod with polycarbonate diffuser4 feet long of capacity 20 watts complete with all accessories baseall as specified & directed by Engr-in-Charge.
21Supply onlyin replacement LED Tube rod LED tube rod with polycarbonate diffuser 4 feet long of capacity 20/22 watts complete with all accessories baseall as specified & directed by Engr-in-Charge.
22Supply only in replacement ofLED 12 WattSquare shapesurface mounted LED Paneldown lighter of size as per site requirementcomplete all as specified and directed,
23Supply only in replacementLEDbulk head light fittings including led lamp 10 wattas per IP65 and making necessary connections complete all as specified
24Supply onlyin replacement LED slim panel cygnus series recess/surface/suspended mounting LED slim ceiling light 2"x2" with extruded aluminium housing and milky diffuser, suitable for recess mounted size 595x595mm complete with LED tube.
25Supply only in replacement of6 WattRound/square recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per existing shaped polycarbonate fixturecomplete all as specified and directed,
26Supply only in replacement of12 Watt Round recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per existing size roundshaped polycarbonate fixturecomplete all as specified and directed,
27Supply only in replacement of 15 WattSquare/round recess mounteddown lighter separate replaceable electronic driver celling cut out as per existingsquare shaped polycarbonate fixturecomplete all as specified and directed,
28Supply only in replacement of18 watt Square recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per exising size/round or square shaped polycarbonate fixturecomplete all as specified and directed,
29Supply only in replacemntbox type PVC rectangular block for mounting switches, sockets, fan regulator etc 4 / 6 way, surface mounting including necessary gitti for fixingcomplete all as specified and as directed.
30Supply only in replacement of frame plate with cover for modular switch 3/4 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed.
31Supply only in replacement of frame plate with coverfor modular switch 6/8 module includingscrews and washers etc model/make as per existingin site complete all as specified and as directed.
32Supply only in replacementceiling fan regulator, electronicSocket type, single phase, 230 volts complete all as specified and as directed.
33Supply only in replacementceiling fan regulator, electronicswitch type, single phase, 230 volts complete all as specified and as directed.
34Supply only in replacement MS machine screw 25 mm longsuitable forfixingbakelitehylam sheets / square blocks complete all as specified and directed .
35Supply onlyin replacementMS Housing box 5 / 6 module suitable formodular switch as per existing including taking out old UNSVswitch boxand making good to the disturb surfaceby pcccomplete all as specified and as directed.
36Supply only in replacement ofMCCB 100 amps 4 pole, AC 415 volts 16 KA, four pole including making connections with suitable size of aluminium lugs of any make /Model as per Existing MCCB Fitted in DB. all as specified.
37Supply only in replacement of modular switch6 Amps one module230 volts AC as per existing model/make complete all as specified and as directed
38Supply only in replacement of modular switch16 Amps one module230 volts AC as per existing model/make complete all as specified and as directed
39Supply only in replacement of modular socket, 5/6A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed.
40Supply only in replacement of modular socket, 15/16A -2/3 pin combined 2 module,230 volts AC as per existing model/make complete all as specified and as directed .
41Supply only inreplacement of capacitor AC 230 volts 2.25 MFD
42Supply only inreplacement of capacitor AC 230 volts 3.15 MFD
43Supply only in replacement of 3 mm thick hylam sheet of any sizeincludingscrews and washers etc as per required at site complete all as specified and as directed.
44Supply only in replacementmoduler bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
45Supply only in replacement of12 Watt round recess mounteddown lighter separate replaceable electronic driver celling cut out dia as per existing , polycarbonate fixturecomplete all as specified and directed.
46S & F inreplacement LEDtube light fitting. ,1 x 18/20 W, 230 V Energy efficient T8, Box type made of CRCA shee heavy duty industrial type housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 18/20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
47S & F ( in repacement) PVC round fan cover plate of size 6" to 8" or as per exiting size complete all as specified and directed.
48S & F ( in repacement) casing caping of existing size as per site including laying of electric wire inside, making electric connection and fixing necessary saddle and gitti at regular interval complete all as specified and directed.
49S & F in LEDmirror fitting.1 x 8/9 W, 230 V Energy efficient , Batten type, polycarbonate housing with reflector cover channel,all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
50Supply only in replacementof single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
51Supply only in replacementof single corewire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
52Material and labour for point wiring with 1.5 Sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one light or bell point controlled by one switch including pvc insulated 1.5sqmm copper conductor continuousearth wire using existing CI/MS sunken box and connecting earth with dolly complete all as specified and directed. ( Note : Switch, socket measured as separate item )
53Description all as per item No 50.00 here in before but for one5 Amps independent board complete
54Description all as per item No 50.00 here in before but for one5 ampssocket out but on the same board complete
55Matrial and labour for point wiring with2.5 sqmm multi strand pvc insulated copper conductor cable in existingconcealed conduit for one 15 amps socket outlet independentcontrolled by one switch including pvc insulated 2.5 sqmm copper conductor continuousearth wire connecting earth with dolly complete all as specified and directed.
56Supply & fix in replacement of building security LED Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240,50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lenscomplete all as specified.
57Supply and fix in repair GI pipe bracket ,made out of GI pipe 50mm dia light grade 1.2mtr long bend to the shape 120 degrees anglecomplete with two nos of clamps for fixing on walls complete all as specified and directed.
58Supply & fixing in replacement ofintegralpost top lantern 25/35 watt complete with black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories and suitable for LED lampcomplete all as specified and directed
59M& labour in replacelment for service wire10 sqmm 2 core pvc insulated and pvc sheathested 1100 volts grade all as specified and directed
60M&L for taking down the existing faulty single phase tamper proof Electronic Energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board, unsv body and all burnt parts complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
61M&L for taking down the existing faulty 3 phase tamper proof Electronic Energy meter with LCD display 415 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board, unsv body and all burnt parts complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
62Attending complaints for taking down geysers of any make & size from existing position of any height for repair, mainteance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch . (ii)Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
63S & F in replacement PVC connection pipe15 mm bore size with PTMT nuts,rubber washers etc complete of length 450 mm long complete all as specified.
64S & F in replacement PVC connection pipe15 mm bore size with PTMT nuts,rubber washers etc complete of length 600 mm long complete all as specified.
65S & F in replacement geyser element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existingtriangular/round shape/make of the geyser under repair complete all as specified.
66S & F in replacement geyser element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existingtriangular/round shape/make of the geyser under repair complete all as specified.
67S&F in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50 / 25 Ltrs complete all as specified.
68S&F in replacement geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified.
69S&F in replacement shyphon assembly suitable for 50 ltr geysers of any make, any type complete all as specified and as directed by Engr -in-Charge.
70S&F in replacement shyphon assembly suitable for 25 ltr geysers of any make, any type complete all as specified and as directed by Engr -in-Charge.
71S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 25 /35 ltr geyser vertical type including rubber gasket complete all as specified and directed.
72S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 50 ltr geyser vertical type including rubber gasket complete all as specified and directed.
73S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 50 ltr geyser complete all as specified and directed.
74S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 25 ltr geyser complete all as specified and directed.
75S&F in replacement 3 Core PVC insulated PVC sheathed flexible copper wire multistrandedof size 2.5 sqmmcomplete all as specified and directed.
76Supply & fix in replacement indicator lamp any type/size 230 Volts complete all as specified and as directed.
77Supply & fix in replacement of brass non-return valve 15 mm dia horizontal/verticle type ISI marked complete all as specified and as directed.
78Supply and fixing in replacement of metal clad plug top 20 Amps complete,all as specified and directed.
79Supply and fixing in replacement of metal clad socket 20 Amps complete,all as specified and directed.
80Disconnecting electrical connection of solar heating device carefully dismantling solar panel with water tube (copper assembly/ETC tube) rubber gasket; nut bolt; biding aluminum channel and glass carefully and servicing/Descaling/cleanning with acid & water circulation and wire brush and brazing of cooper tube checking of leakageif any . After servicing reassemble the same making electric and water connection and testing of solar water heater complete all as specified.
81Supply and fix in replacement of heating elements for solar water heating system5 KW with rubber gasket for any type of solar water heater as per exisiting complete all as specified and directed.
82Supply and fixingin replacement of 500 ltrs pre insulated hot water storage tank with stand (inner tankSS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /argon welding and reclading,connecting the removed water lines,testing of solar hot water tank all as specified and as directed.
83Supply and fix inreplacement of Syntex tank cap 1000 ltrs of Solar complete all as specified and directed.
84Supply and fix inreplacement of Syntex tank cap 500 ltrs of Solar complete all as specified and directed.
85Supply and fix inreplacement of GI Pipe medium grade with insulation dia 20mm complete all as specified and directed.
86Supply and fix inreplacement of GI Pipe medium grade dia 15mm complete all as specified and directed.
87Supply and fix inreplacement thermostat forSolar water heater, AC, SP 220 volts including making necessary connection, ISI marked, complete all as specified and as directed.
88Supply and fix inreplacement of temparature gauge for water heating systemISI marked, complete all as specified and as directed.
89Material and labour in replacement of solar glass panel complete all as specified and directed including collant quiet, absorbing plates , flow tube , insulation coolant outlet certificate for transmissibly will be provided from approved company complete all a specified and directed.
90Supply and fixing in replacement of automatic monoblock pressure/booster pump size 25 mm x25 mm, tech motor S1 class B 230 Volts 500 Hz, RPM 2800, 10 MF, Input power 650 watt with pressure tank of cap 19 Ltrs PS max pressure bar 10 PT test pressure bar 14 with complete accessories incl GI pipe/gate valve/NRV complete all as specified and directed.
91M&L for replacement of geyser assembly including heating element , relay , thermostat etc completesuitable for 25 ltr cap geysers as per existing make Complete all as specified and as directed by Engr-in-Charge.
92Supply and fixing in replacement of Air termination single pointed aluminium rod 12mm dia and 300mm long including taking out the existing one complete all as specified and directed
93Description all as per item No 90.00 here in before but Fixing only ofAir Termination rod 12mm dia and 300mm long complete etc retrievedfor reusecomplete or all as directed and Specified.
94Supply and fixing in replacement of test terminal blockmade of gun metal or phosporus bronze size 75x75x25 mm drilled and screwed including 03 Nos, 8mm dia25 mm long hex, head scew including taking out existing unsv test terminal blocks complete all as specified and direted.
95Description all as per item No 92.00 here in above but Fixing only test terminal block made of gun metal of any size complete etc retrievedfor reusecomplete or all as directed and Specified by Engr-in-Charge.
96Supply and fixing in replacement aluminum strip 25x3.15mm with saddles and fixing screws with rubber washers for protection of water leakage etc for roof conductors and down conductors above ground including fixing clamps/insulator andtaking out existing aluminium strip complete all as specified and directed.
97Supply and fixing in replacement GI strip 32x6 mm with saddles and fixing screws with rubber washers for protection of water leakage etc for roof conductors and down conductors above ground including fixing clamps/insulator andtaking out existing aluminium strip complete all as specified and directed.
98Description all as per item No 95.00here in above but Refixing onlyGI strip including re aligning of strip and refixing of PVC/Porcelain insulatorswith 6cm long screws etc for roof conductors and down conductors retrieved ground complete all as speciifed and directed.
99S&F in replacement for GI tubing, 40mm bore, light grade with fittings like MS clamps, Nut & Bolts for fixing to wall or laid in floors complete all as specified and directed.
100M&L for PCC 1:2:4, type B1 (using 20mm stone aggregate) for install to air termination rodand fair finish to the exposed surfaces complete all specifed and direccted.
101M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized iron stripof size 25X4 mm by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade ) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PART 1 , with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switche, DBs) completeall as specified &testing on completion.