Tender For Repair And Maintenance To Certain Internal Electrification Works In Md Accn Area In Zone C And D Under Age E/M At Ge Jhansi, jhansi-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance To Certain Internal Electrification Works In Md Accn Area In Zone C And D Under Age E/M At Ge Jhansi. Submission Date for this Tender is 23-05-2024. Electrification Work Tenders in jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43297643
Tender For Repair And Maintenance To Certain Internal Electrification Works In Md Accn Area In Zone C And D Under Age E/M At Ge Jhansi
Open Tender
Indian
Uttar Pradesh
jhansi
23-05-2024

Tender Details

Tender For Repair And Maintenance To Certain Internal Electrification Works In Md Accn Area In Zone C And D Under Age E/M At Ge Jhansi

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

Name of Work : REPAIR AND MAINT TO CERTAIN INTERNAL ELECTRIFICATION WORKS IN MD ACCN AREA IN ZONE "C" AND "D"UNDER AGE E/M AT GE JHANSI
Sl. No. Item Description
1Taking down carefully existing copper/aluminium point wiring (light,fan, socket or power) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, regulators, sockets, bell push and call bell wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc andmaking good the disturbed surfaces of walls, floors, ceiling etcwith cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
2M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of electrogalvanised steel terminal box of thickness not less than 18 SWG with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc.and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green.complete all as specified and directed for the following points (Note- rates of chasing/cutting & making goods shall be included in the unit rate):-
3One light / ceiling fan / exhaust fan / call bell point controlled by one switch
4One 6A socket point controlled by one switch on independent board
5One 6A socket point controlled by one switch on same board
6All as per srl item No 2 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
7All as per srl item No 2 here-in-before but with 4 sq mmFRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
8All as per srl item No 2 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board. but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
9M&L for point wiring for modular fittings complete with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), including provision of electrogalvanised steel terminal box concealed in wall/ floor etc including provision of modular cover plates with frames and 1.50 sq mm PVC insulated unsheathed stranded copper conductor (FRLSH) cable for common earth and connecting to earth dolly and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green. all as specified and directed by Enrg-in-charge. (Note- rates of chasing/cutting & making goods shall be included in the unit rate) :-
10One light / ceiling fan / exhaust fan / call bell point controlled by one switch
11One 6A socket point controlled by one switch on independent board
12One 6A socket point controlled by one switch on same board
13All as per srl item No. 3 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
14All as per srl item No. 3 here-in-before but with 4 sq mmFRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
15All as per srl item No. 3 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
16M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in & incl PVC trunking of size not less than 32x12mm ISI marked ivory white with all accessories such as tee, bend, joint cover including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated hylem/Anchor ISI marked top cover 3.0 mm thick for mounting of switches/ sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green. Make - Polycab/Finolex/Havells
17One light / ceiling fan / exhaust fan / call bell point controlled by one switch
18One 6A socket point controlled by one switch on independent board
19One 6A socket point controlled by one switch on same board
20All as per srl item No. 4 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
21All as per srl item No. 4 here-in-before but with 4 sq mmFRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
22All as per srl item No. 4 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
23M&L for point wiring with 1.5 Sqmm PVC insulated FRLSH, unsheathed, copper conductor stranded 1100 volt grade cable in existing conduitincluding anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and PVC laminated ISI marked top cover 3.0 mm thick for mounting of switches/ sockets/ regulator etc and PVC insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and colour coding of cables such as Phase -Red, Neutral – Black, and Earth – Green.
24One light / ceiling fan / exhaust fan / call bell point controlled by one switch
25One 6A socket point controlled by one switch on independent board
26One 6A socket point controlled by one switch on same board
27All as per srl item No 5.00 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.
28All as per srl item No 5.00 here-in-before but with 2.5 sq mmFRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switchon independent board.but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
29M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
302 runs X 2.5 Sqmm + 1 run X 2.5 Sqmm (earth wire)
312runs x 4 sqmm(Ph & N) + 1run x 4 sqmm (earth wire)
322runs x 6 sqmm(Ph & N) + 1run x 6 sqmm (earth wire)
332runs x 10 sqmm(Ph & N) + 1run x 10sqmm (earth wire)
34M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through in &incl PVC trunking of size not less than 32x12mm ISI marked ivory whiteand its all accessories including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC trunking shall be measured as one unit length)
352runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
362runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
37Notes for item No. 6 & 7: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
38S&F of Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
39S&FofSwitch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
40S&F of electronic fan regulatorin 5 steps, 240V, 50Hz complete all as specified and directed.
41S&F of Socket 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
42S&F of Socket, 6 pin, 6/16Amp, multipurpose240 volts, complete all as specified and directed.
43S&F of Modularswitch1way6A,1 module 240V, 50Hz complete all as specified and directed.
44S&F of Modularswitch1way16A,1 module 240V, 50Hz complete all as specified and directed.
45S&F of Modular fan regulator step type in 5 steps, 240V, 50Hz complete all as specified and directed.
46S&F of Modular Socket,6A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
47S&F of Modular Socket6A/16A - 2/3 pin combined 2 module 240V, 50Hz complete all as specified and directed.
48S&Fof Modular blank plate 1 module complete all as specified and directed.
49S&F of Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and directed.
50S&F ofCeiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
51S&Fofintegrated LED batten 10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fittingcomplete all as specified and directed.
52S&Fof modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 20A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.
53S&F ofintegrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
54S&F ofintegrated LED batten 20 watt, 4 feet long, Tri light (cool white, warm white & Morning white) combination of these in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
55S&F of LED bulkhead luminaire 10W in die-cast aluminium alloy/ PVC body heat resistant prismatic glass cover, with specially designed gasket for minimum IP 55 degree of protection complete all as specified and directed by Engineer-in-Charge.
56S&F of LED street/security light fitting 30 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed.
57S&F of LED street/security light fitting 45 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed.
58S&F of LED post top lantern light fitting 20watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv and complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP65 degree of protection including provision of 25mm dia medium grade GI pipe of length 0.50m bent to required shape and fixing on ground/walls with pcc 1:2:4 using 20 mm size stone aggregate upto 30 cmand provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed.
59S&F of sleek round recessed cum surface mounting LED down light 12 W with aluminium die-cast body, finish with drop down PC diffuser warm / full white with optimized heat sink for efficient dissipation including taking down existing unserviceable light fitting of any description complete all as specified and directed.
60Taking down unserviceavle VTPN/ TPN DB with MCB"s of any make/capacity complete all as specified and directed by Engr-in-Charge.
61S&F of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surfacecomplete all as specified and directed.Note: MCCB / MCBs shall be measured and paid separately.
62S&F of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surfacecomplete all as specified and directed. Note: MCBs shall be measured and paid separately.
63Taking down unserviceavle Sheet metal box & MCB DB SPN with MCB"s of any make/capacity complete all as specified and directed by Engr-in-Charge.
64All as per item No. 32 here-in-before but SPN, 12 way, 230 V, 1 phase, AC Note:MCBs shall be measured and paid separately.
65All as per item No. 32 here-in-before but SPN, 8 way, 230 V, 1 phase, AC Note:MCBs shall be measured and paid separately.
66All as per item No. 32 here-in-before but SPN, 4way, 230 V, 1 phase, AC Note:MCBs shall be measured and paid separately.
67S&Fof MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed.
68S&Fof MCB 100A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed.
69S&F of MCB 63A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed.
70S&F of MCB 40A, 10 KA, SPN, "C" curve, 240 V, 50 Hzcomplete all as specified and directed.
71S&Fof MCB 6 - 32A, 10 KA, single Pole, "C" curve, 240 V, 50 Hzcomplete all as specified and directed.
72S&F of call bell ding dong, AC, 240V, 50Hz complete all as specified and directed.
73S&F of Modular Bell Push , flush type, 6Amp, 1 module50Hz complete all as specified and directed.
74S&F of Bell Push , flush type, 5 Amp 50Hz complete all as specified and directed.
75Taking down ceiling fan/exhaust fan of any sweep, removing blade, cleaning the fan completely of dust and dirt and Re- hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook rubber pad, nut bolts and washers etc,complete all as specified and directed by Engr-in-Charge.
76Supply and fix of ventilating fan with plastic body with louvers, 200mm sweep, single phase, 230 volts, 50 Hz. Complete all as specified and directed.
77Supply and fix of ventilating fan with plastic body with louvers, 250mm sweep, single phase, 230 volts, 50 Hz. Complete all as specified and directed.
78S&F of Decorative wall light fixture made up of Polycarbonate with and including 7W retrofit LED lamp, full white/ Warm whiteof approved model complete all as specified and directed.
79S&F in replacement of 3mm thick phenolic laminated hylam sheet of size 9" X 11" including necessary cutting, drilling holes for fixing of switches, sockets & fan regulators etc and fixing the hylam sheet on existing metal flush box with brass/GI screws with washers complete all as specified and directed. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
80S&Fin replacement of 3mm thick phenolic laminated hylam sheet of size 8" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
81Supply and fix in replacement of 3mm thick phenolic laminated hylam sheet of size 5" X 5" including necessary cutting and drilling holes for fixing of switches, sockets & fan regulators etc as per site requirement and fixing the hylam sheet on existing metal flush box with new brass/GI screws with washers complete all as specified and directed by Engineer-in-Charge. Note: S&F of switches, sockets & regulators shall be measured and paid separately.
82Taking down old unserviceable of LT cable of any size complete all as specified and directed by Engr-in-Charge.
83Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etccomplete all as specified and directed.
84Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 25 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
85Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed,10 sq. mm nominal cross section, 2 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
86Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor twin core, 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections including connecting on LT OH line / energy meter / DB etc complete all as specified and directed.
87Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
88Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
89Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
90Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
91Supply and fixof ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper windingwith brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable fromceiling rose all as specified and directed by Engr-in-Charge.Note: Old Ser/ UNSV fans removed from the site are property of Department, will be deposited at E/M yard
92Supply and fix of ceiling fans complete with blades, down rods, and accessories, 230 V, 1400 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper windingwith brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable fromceiling rose all as specified and directed by Engr-in-Charge. Note: Old Ser/ UNSV fans removed from the site are property of Department, will be deposited at E/M yard
93M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :-(a) The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. (b) Earthing result should be less than 3 Ohm required.
94S&FLED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type (Cool white & warm white) with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling/grid ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
95S&FLED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type (Cool white & warm white) gypsum ceiling with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
96Supply and fix in replacement of exhaust fan with steel body 300mm sweep with blade , frame and louvers , single phase, 230 volts, 50 Hz. including taking down existing unserviceable exhuast fan of any description complete all as specified and directed.Note :- Old and u/s exhaust fan deposited to E/M yard store as a govt property.
97Supply and fixingin replacementPVC conduit including fitting such as tee,elbow,bend etc20mm dia ISI (MMS) grade, incl taking down old unserviceable conduit all asspecified and directed.
98Supply and fixing in replacement PVC casing Capingtee,elbow,bend etc20/25 mm dia ISI(MMS) incl taking down old unserviceable casing caping all asspecified and directed.
99Supply and fix LED strip, 24 watt, warm / cool white/ tricolour,18 mtr length, flexible PCB body type including driver, IP 20 protection with accessories such as 06A plugtop, flexible cable etc complete all as specified and directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail