Tender For Provision Of 02 X Borewell With Submersible Pump And Spl Repair Of Conversion Of Lt Oh To Lt Ug Cable And Connected Work At Gvtc At Itarana Cantt Alwar, alwar-Rajasthan

Military Engineer Services-MES has published Tender For Provision Of 02 X Borewell With Submersible Pump And Spl Repair Of Conversion Of Lt Oh To Lt Ug Cable And Connected Work At Gvtc At Itarana Cantt Alwar. Submission Date for this Tender is 01-06-2024. LT Cable Tenders in alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

43297611
Corrigendum : Tender For Provision Of 02 X Borewell With Submersible Pump And Spl Repair Of Conversion Of Lt Oh To Lt Ug Cable And Connected Work At Gvtc At Itarana Cantt Alwar
Open Tender
Indian
Rajasthan
alwar
01-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Provision Of 02 X Borewell With Submersible Pump And Spl Repair Of Conversion Of Lt Oh To Lt Ug Cable And Connected Work At Gvtc At Itarana Cantt Alwar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-May-2024 Corrigendum No 1 Date 01-06-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94500.0 /-
Tender Value
INR 47.17 Lakhs /-

Attachment

FileName File Description File Size
c09c380b-7a3b-4de0-8858-2f23cbdc19c1.html Tender Notice 0 KB
BOQ_729931.xls Tender Document 0 KB
Tender8213.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : PROVN OF 02 NOS BOREWELL WITH SUBMERSIBLE PUMP AND SPECIAL REPAIR CONVERSION OF LT OH TO LT UG CABLING SYSTEM AND CONNECTED WORK AT GVTC ITARANA CANTT ALWAR
Sl. No. Item Description
1Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for laying of pipe and getting out in soft/loose soil incl cutting of roads where reqd,laying of cable, foundation of poles, stays assembley etc complete all as specified & directed.
2Returning, filling in, including spreading, levelling watering andwell ramming in layers n.exc 25 cm in soft/loose soil complete all as specified & directed.
3Removal of excavated soil to a distance not exc. 50 m anddepositing where directed at a level not exc. 1.5 mtr above the startingpoint etc complete all as specified & directed.
4M&L brick cover of burnt clay fly ash bldg brick old size brick "B" class with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjecent bricks bricks not exc 10 mm over UG cable for protection etc complete all as specified & directed.
5M&L sand cushioning to PVC UG cable with screened and washed sand punning to provide a required cover etc complete all as specified & directed.
6Trial bore holes 150mm dia in any type of strata of bore well if the same is found fit otherwise to fill up the same hole as directed including submitting the strata details both graphically recorded as well as strata results.Note :-The rates quoted shall deemed to include to get survey done for availability/facibility of water as recommended by CGWD before execution of work.
7Widening of trial bore by drilling with rotary system upto 450mm dia bore at any depth including all works pertaining to boring etc complete in all respects and all as specified, in alluvium soil / soft strata.
8All as per item No 7.00 above but of 200mm dia in hard rock and drilling with DTH system till meeting water strata all as directed.
9All as per item No 7.00 above but of 200mm dia in hard rock and drilling with ODEX system till meeting water strata all as directed.
10Supply and assembling jointing lowering and fixing in position of ERW MS casing pipe 200mm bore of 5.4mm thickness (minimum) upto required depth below ground level in all strata (including cutting welding as required, painting etc complete ISI markedincluding MS well cap and also as specified and directed. Make - TATA/Swstik/Jindal/Prakash
11Supply, assembling, including jointing lowering and fixing in position ERWMS slotted pipe 200mm bore of 5.4mm thickness ( minimum ) having slots of 1.59 mm wide, 75 mm long assembled and lowered as per location chart approved by the GE including cutting welding as required and painting etc complete all as specified. Note for item Nos 10.00 &11.00 :- Rate quoted by Contractor shall deemed to include for S&F well capacity 200mm bore on top of pipe with locking arrengement till the borewell become functional complete.
12Supply and packing with Pea gravel of 8mm to 4.6mm size of approved quality as ordered to packed around the casing/slotted pipe in bore well etc complete all as specified and directed.
13Development of tube well by compressed air with compressor of minimum capacity of 150 PSI and 450 CFM all as specified. Note:- (i) Yield test for the bore well by continuously pumpingto determine safe pumping yield to be carried out by contractor at site and necessary report to be submitted. (ii) Testing of water for potability, dissolved solids, physical/chemical and bacteriological testing etc from the govt lab shall be carried out by the contractor all as directed and test report shall be submitted. (iii) The rates quoted shall deemed to include the above provisions.
14S&F housing clamp 90 cm long 20 cm wide out of 6 mm thick MS plate for 200mm dia casing pipe with necessary MS Bolts, nuts & washers at ground level in PCC (1:2:4 ) type B1 using 20mm graded stone aggregate in block etc complete all as specified and directed.
15M&L strata sample box of second class hard wood (Hollock / Bijasal ) of size 40cm x 30cm x 20cm etc complete all as directed by Engineer-in charge.
16M&L 50mm bore GI medium grade column pipe in 6 m length with flangedjoints duly scewed and welded with pipe suspended in deep well complete with slote for lead, GI flanges, rubber gaskat clamps, bolts, nuts, etc competeall as specified and directed.
17Supply, laying, jointing/connecting and testing for 80 mm bore steel tubing galvanised medium grade pipe with all fittings, laid in trenches etc complete all as specified and directed.
18S&F non return valve cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc complete ISI marked of size 80 mm bore for submersible pump etc complete all as specified as directed.
19S&F sluice valve, cast copper alloy, PN 1.6, of size 80mm dia complete including connecting etc complete all as specified as directed.
20Supply, installation, testing and commissining submersible pump set electric driven 3 phase, 415 volt, 50 c/s having discharge upto 14000 Lit / hrs at 200m head 18 stage not less than 20 HP etc complete all as specified as directed. Make- KSB/Kirlosker/CG.
21Supply, install, testing & commissioning of LT panel outdoor type (Kiosk) factory made powder coated paint made of 3 mm thick CRCAsheet, CPRI approved, dust and vermin proof protection, with 200 Amps copper bus bars front opened with locking arrangements mounted on angle iron frame 40x40x6mm, 45cm height from ground level comparising of the following accessories :-(a) MCCB 100 Amp 35 KA rating 4 pole 440 volts-01 No Make-ABB/Legrand/L&T. (b) MCB-63 Amps, TPN 440 V, 16 KA-01 No Make-ABB/Legrand/L&T (c)Starter, star delta, fully automatic suitable for 15 HP 3 phase elect motor - 01 No Make-L&T/Havells/AE (d)Digital Amp meter with selector switch & CT0-50 Amps - 01 No (e)Digital Volt meter with selector switch 0-500 Volts -01 No (f) Single phase preventor mini lec VSP-II - 01 No.Make-Havells/ ABB/ L&T/BCH/C&S (g) Phase sequance corrector 15 HP motor, 3 phase- 01 No.Make-Havells/ABB/L&T/BCH/C&S. (h)LED Indicator lamp - 03 Nos (RYB).(j) Wiring with suitable size copper conductor cable for LT panel. (k) Power factor correction capictor bottle type, 3 KVAR 3 Ph- 01 No. Make- Legrand/ABB/EPCOS
22S&F 1100 Volts grade submersible cable flat 3 core with copper conductor 10 sqmm stranded fixed to column pipes with suitable clamps jointing material etc complete all as specified and as directed.
23Supply & laying in trenches or passing through pipe/fixed to pole/wall PVC insulated and PVC sheathed armoured heavy duty electrical cable with multistranded aluminium conductor 1100 volts grade 25 Sqmm 3.5 core etc complete all as specified and directed.
24M&L GI pipe (light grade) for protection of LT Cable fixed to wall/poles /road crossing including clamps complete of size 40/50mm bore complete all as specified and directed.
25M&L earthing complete with galvanised steel earth plate eletrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5meters below normal ground level, connecting to galvanised earth strip 25x4mmby means of bolts, nuts check nuts and washer of galvanised iron or steeluptotest point all as shown in electrical plate No 3 of SSR Part-I connected to test point incl PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40mm dia for earth lead protection from earth plate to test point and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified including testing on completion.
26M&L providing cement concrete in foundation, filling and mass concrete all including required from work etc complete type B-2 (1:2:4) for sealing bacteriologicaltreatment/surface etc complete all as specified and directed.
27M&L connection GI pipe line 80 mm toCI/GI water mains of size 80/100 mm dia with CI/GI joints & fittings and necessary connecting accessories etc complete all as specified and directed.
28S&F analog water flow metercast iron body flanged ends & drilled horizontal heavy duty including jointing material etc complete ISI marked of size 80 mm bore for submersible pump etc complete all as specified and directed.
29Taking down old unserserviceable ACSR Conductor and GI wire of any size from LT Poles and removing from site etc complete all as specified and directed.
30Taking down old unserserviceable GI Earth wire/Guard wire etc.of any size from LT Poles and removing from site etc complete all as specified and directed.
31Dismantling and taking down of old unserviceable pin type/ shackle type insulators and from any height of electric pole, complete all as specified and directed.
32Taking down old unserviceable cross -arms/Clamps/nut bolts and Angle section etc from LT Pole any size, etc complete all as specified and directed.
33Dismantling and taking down old unserserviceable stay assembly from LT Poles and removing from site etccomplete all as directed.
34Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule etc complete all as specified.
35M&L for PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in coping/pedestal of polesincluding providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed.
36Supply, laying, jointing and testing XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminiumconductor of size 95 Sqmm 3.5 Core cable laid in trenches/pasing through pipe under road crossing etc all as specified and directed.
37All as per item No 36.00 but size 70 Sqmm 3.5 Core.
38All as per item No 36.00 but size 35 Sqmm 3.5 Core.
39All as per item No 36.00 but size 25 Sqmm 4.0 Core.
40All as per item No 36.00 but size 25 Sqmm 2.0 Core.
41All as per item No 36.00 but size 16 Sqmm 4.0 Core.
42All as per item No 36.00 but size 16 Sqmm 2.0 Core.
43Boring of holes under road,pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure.
44M&L Galvanized iron tubing, 50 mm bore medium grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete. Make : Prakash/Jindal/Surya.
45Supply & errecting Cable path indicators for LT Cable made of CI plate fixed on MS angle iron size 25x25x5mm and 60 Cm long. and fixing in ground 30 Cm below ground level in PCC 1:3:6 type B-1 using 40mm grade stone aggregate of size 30x30x30cm . Cable path indicators shall be provided at distance of every 30 meters and at cable joints and turning of all cables and incorporated LT 1100 Volts on it.including PCC & earth work complete all as specified and directed.
46Supply and fix for pole mounted junction box made out of one piece moulded SMC IP-65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance freesize 300x200x100 mmfixing on pole with MS flat 25x3mm clamp including nut boltsfront openable all as specified and directed. Make : Sintex/Finolex/Universal.
47Supply and fix for pole mounted junction box made out of one piece moulded SMC IP-65 protection having aluminium bus bars 100 Amp three phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance freesize 300x200x100 mmfixing on pole with MS flat 25x3mm clamp including nut boltsfront openable all as specified and directed. Make : Sintex/Finolex/Universal.
48Supply, installing, testing and commissioning factory made, floor mounted outdoor type of sizes 85x75x45cm , LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having bus bar chamber with insulated Aluminium bus bar four wire system, colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 3.2 mmCRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6 mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories: INCOMING (i)Adjustable thermal magnetic MCCB 4 pole 160 Amps,25 KA - 01 No (ii) Combined Ammeter & Voltmeter(10/0-400/500)A/Vrating - 01 No(iii)Aluminium bus bar 400 Amps with insulator - 04 Nos (iv) Instrument control fuses and indication lamp (RYB) with selector switch – 01 Set OUTGOING (i)Adjustable thermal magnetic MCCB 3 pole, 125 Amps 25 KA- 01 No (ii) Adjustable thermal magnetic MCCB 3 pole, 63 Amps 25 KA- 01 No(iii)MCB TPN, 63 Amp "C" curve 10 KA - 01 No (iv)MCB SP, 25 Amp "C" curve 10 KA - 08 Nos (v)Contactor 3 pole 32 Amp- 01 No (vi)Astronomical digital timer- 01 No
49All as per Item No 48.00 but sizes 85x75x45cm and the following accessories:- INCOMING (i)Aluminium bus bar 400 Amps with insulator-04 Nos (ii)Combined Ammeter & Voltmeter (10/0-400/500) A/V rating - 01No (iii)Instrument control fuses and indication lamp(RYB) with selector switch – 01 set OUTGOING (i)Adjustable thermal magnetic MCCB 3 pole,100 Amps 10 KA -01 No (i)Adjustable thermal magnetic MCCB 3 pole,63 Amps 10 KA -02 Nos (ii) MCB TPN 63A,10 KA- 02 Nos
50All as per Item No 48.00but sizes 85x75x45cm and the following accessories:- INCOMING (i)Aluminium bus bar 400 Amps with insulator-04 Nos (ii)Combined Ammeter & Voltmeter (10/0-400/500) A/V rating - 01No (iii)Instrument control fuses and indication lamp(RYB) with selector switch – 01 set OUTGOING (i)Adjustable thermal magnetic MCCB 3 pole, 63 Amps 10 KA -02 Nos (ii)MCB TPN 63 Amps "C" curve 10 KA - 04 Nos
51S&F 2.5 sq mm PVC insulated & sheathed cable twin core copper conductor cable from street light junction box/feeder piller to street light fittings complete all as specified and directed. Make of cable : Havells/Finolex/Polycab.
52Supply and fixing ofsteel conduit pipe of size 20mm dia (fixed to poles with required size of flat iron 25mm x 3mm clamps, bolts, nuts) fromjunction box to street light fittingand making necessary connectionatstreet light pole and fixing accessories complete Make of steel conduit : Jindal/Prakash/Surya.
53S&F street light bracket made to shape at required angle made out of 40mm dia (light grade) GI tubing of length not less than 1.5m long fixing on wall/pole suitable for holding street light fittings including mild steel flat iron 50 x 6 mm clamp 02 Nos with nuts, bolts & washers complete all as specified and directed.
54M&L load line distribution board TPN 4 way vertical type with and including provission for adjustable thermal magnetic (63-100) Amps TP MCCB as incommer and MCB"s - SP/DP/TP as out going, suitable for for IP-20 complete of Make : Havells/HPL/C&S.
55M&L adjustable thermal magnetic 3 pole MCCB (63-100) Amp 50Hz 415 volts with rupturing cap 25KA of Make : Havells/HPL/C&S.
56S&F steel tubular swaged pole 09 meter long type 410 SP-31 with & including two coats of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.20 metre height from top of PCC coping/pedestal and applying two coats of aluminium paint over a coat of aluminium red oxide primer to remaining portion of pole and marking pole number and including dismantling and taking down old unserviceable pre-stressed concrete pole 09 metre long all as specified & as directed.Note : Excavation & earthwork, PCC in foundation & coping shall be measured and paid for separately. Make : NTC Kanpur/India tube co/Jindal steel/Bombay tubes.
57M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of stay assembly & poles and similar works complete all as specified.
58M&L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate in massconcretefor pole all as directed by Engineer-in-Charge.
59M&L for PCC 1:2:4 type B2 using 20 mm graded stone aggregate in copingconcretefor pole all as directed by Engineer-in-Charge.
60Fixing only retrived machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15650-2008 of 60mm thickness, M-35 grade with grey cement and no pigment except tiles, including taking down and 25cm thick sand cushioning complete all as specified and directed.(Note:-Sand cushion will be measured and paid separately).
61S&F in repair LED street light fitting 120 watt 230V AC outdoor type with high pressure die cast aluminium housing 50mm dia and heat resistant complete with driver, lamp, bracket, clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete. Make : Havells/HPL/Bajaj/Shakti.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail