}

Tender For Repair/Maintenance To Brick Work Plastering Tiling Sanitary Items Plumbing Work Plinth Protection Interlocking Path Hard Standing Boundary Wall Sewage Disposal And Misc B/R Works To Zone A And Zone B At Chcc In The Area Of Age E/M Hosp Under Ge, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/Maintenance To Brick Work Plastering Tiling Sanitary Items Plumbing Work Plinth Protection Interlocking Path Hard Standing Boundary Wall Sewage Disposal And Misc B/R Works To Zone A And Zone B At Chcc In The Area Of Age E/M Hosp Under Ge. Submission Date for this Tender is 22-05-2024. Paver Blocking Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43297372
Tender For Repair/Maintenance To Brick Work Plastering Tiling Sanitary Items Plumbing Work Plinth Protection Interlocking Path Hard Standing Boundary Wall Sewage Disposal And Misc B/R Works To Zone A And Zone B At Chcc In The Area Of Age E/M Hosp Under Ge
Open Tender
Indian
Uttar Pradesh
lucknow
22-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maintenance To Brick Work Plastering Tiling Sanitary Items Plumbing Work Plinth Protection Interlocking Path Hard Standing Boundary Wall Sewage Disposal And Misc B / R Works To Zone A And Zone B At Chcc In The Area Of Age E / M Hosp Under Ge E / M Lucknow

Key Value

Document Fees
INR 500 /-
EMD
INR 95820.0 /-
Tender Value
INR 47.91 Lakhs /-

Attachment

FileName File Description File Size
92718aec-3964-497f-94da-c6692773101d.html Tender Notice 0 KB
BOQ_730079.xls Tender Document 0 KB
Tender41.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: REPAIR / MAINT TO BRICK WORK, PLASTERING, TILING, SANITARY ITEMS, PLUMBING WORK, PLINTH PROTECTION, INTERLOCKING PATH, HARD STANDING, BOUNDARY WALL, SEWAGE DISPOSAL AND MISC B/R WORKS TO ZONE "A‘ & ZONE ‘B’ AT CH (CC) IN THE AREA OF AGE E/M (HOSP) UNDER GE E / M LUCKNOW
Sl. No. Item Description
1Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles all as directed.
2Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level).
3Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for.
4M&L for brick work with sub class "B" bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6
5M & L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in coping, chajja, facia and the like including weathering, slightly rounded or chamfered angles with & inclnecessary use and waste of form work for fair faces of concrete
6Supply only integral water proofing compound powder ISI marked
7Mild steel work Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 as in small articles like angle iron framing work for manhole, rungs/steps in man hole
8S&F in repairs Chromium plated fancy Bib taps with cup , cast copper alloy with crutch handle, screwed for15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified
9S&F in repairs Chromium plated fancy long body Bib taps with cup , cast copper alloy with crutch handle, screwed for15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified
10S&F in repairs Bib taps with cup , cast iron with crutch handle, screwed for15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified
11S&F in repairs Chromium plated elbow operated fancy long body Bib taps with cup , cast copper alloy, screwed for15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified
12S&F in repair cast iron floor trap with chromium plated grating including jointing to waste pipe wih cement mortar (75 mm bore of pipe).
13S&F in repairsBrass chromium plated shower rosewithout swivel joints , any size, including fixing to steel pipe or union complete all as specified .
14S&F in repairs Chromium plated ,Concealed stop cock Reduced body ISI Marked, , cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified
15S&F in repair CP Angle stop cock ( one way) long thread with wall flange , fancy type screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified.
16S&F in repairs Pillar taps, fancy type cast copperalloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l"ettered " "HOT" or "COLD" with long screwed shanks and fly-nuts , screwed for iron pipe
17S&F in repairs PTMT( Polytetra Methyllene Terephthalate )Bib taps suitable for 15 mm bore pipestandard of PTMT any colour screwed, for iron pipe and fixed ( Minimum weight 15 mm-90 gms complete all as specified .
18S&F in repairs swan neck Pillar taps, fancy type cast copperalloy , chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without lettered " "HOT" or "COLD" with long screwed shanks and fly-nuts , screwed for iron pipe
19S&F in repairs elbow operated Pillar taps, fancy type cast copperalloy , chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without lettered " "HOT" or "COLD" with long screwed shanks and fly-nuts , screwed for iron pipe
20S&F in repairs CP Angle stop cock( two way) long thread with wall flange , screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed C complete all as specified .
21S&F in repairs CP Bib tap with stop cock( two way) long thread with wall flange , screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixedcomplete all as specified .
22S & F for Health faucet, chromium plated rising spray with wall brackets with 1.5m long metallic flexible tube,with 15 mm dia complete all as specified and as directed.
23S & F for Jet spray, chromium plated rising spraywith 1.5m longflexible tube,with 15 mm dia complete all as specified and as directed.
24S & F in repair for chromium plated paper holder fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.
25S & F in repair for PVC venetian blinds of selected quality and shade alongwith complete fixing arrangements all as specified and as directed.
26M & L forSuper heavy series PVC Wall panelling consisting of 5-10mm thick (hollow) Plain/wood colour PVC sheet as approved including complete fixing arrangments on wall/ceiling of including dismantling of unserviceable existing wall panelling complete all as per manufactures specifications of Make Polywood or equivalent of other make.
27S&F in repairssinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm
28S&F sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm
29S&F in repairsfor 15mm bore pipeBrass CP wall mixer formixing hot & cold water screwed down for iron pipe and fixed
30S&F in repairsfor 15mm bore pipe Brass CP basin mixer formixing hot & cold water screwed down for iron pipe and fixed
31S & F in repairs 5mm thick of size 600mm x 450mm bevelled edge mirror of selected quality glass, fixedto wall with stainless steel Bolt flat head mirror screw (minimum 4 Nos) with spacerscomplete all as specified.
32S & F in repairs 6mm thick bevelled edge mirror of selected quality glass, fixedto wall with stainless steel Bolt flat head mirror screw (minimum 4 Nos) with spacerscomplete all as specified.
33M&L in repairs 600mm x 450mm bevelled edge mirror 5.5mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP Brass screws and cup washers complete all as specified.
34S&F in repairs CP mild steel gratings suitable for 75/100 mm dia forNT/ FT complete all as specified.
35S&F in repairs Chromium plated Brass Tubular towel rod, of 24" (60 cm long) complete all as specified.
36S&F in repair vitreous China wash down water closet pan ( padestal pattern Water Closet ) , including fixing bolts, flushing cistern and flush pipe , including connection to drain ( or outgoing pipe) and to flushing pipe , etc., complete including make good the floor as existing
37S&F in repairs VC WHITE Squatting pan ,"Orissa" pattern size 580x440mm with integral footrests water closet) with "P" or "S" trap front or back inlet complete including lime concrete for bedding, connection to drain pipe and to flushing pipe , anti syphon complete including make good the floor as existing
38S&F in repairs Low level flushing cistern, moulded fromvirgin poly propylene complete all as specified and directed.
39Supply and fixing in repairsPlastic water closet seat, white, closed pattern with flat bottom , and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
40S&F in repairs PTMT connections 15 mm size with PTMT nuts of length 450 mm complete all as specified.
41S&F in repairs PTMT connections 15 mm size with PTMT nuts of length 600 mm complete all as specified.
42S&F Vitreous China bowl urinal flat back, size of 465x355x265 mm White ( minimum), with grating and union for discharge pipe ( excluding flushing cistern, flush pipe , and waste pipe) , fixed in repairs including connections to flushing pipe and outgoing
43S&F Vitreous Chinaurinal flat back, half stall (Large size) with grating and union for discharge pipe ( excluding flushing cistern, flush pipe , and waste pipe , fixed in repairs including connections to flushing pipe and outgoing
44S&F in repair vitreous china wash basin (WHB) , white , flat back , size 550mmx400mmincluding brackets,waste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting
45S&F 32mm bore flexible pipe of PVCfixed to WHB/ urinals as waste pipe ( not less than 600mm) including PVC coupling complete all as specified.
46M&L in repairs 32 mm waste fittings , brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixedcomplete all as specified fixed
47S&F in repairs32 mm bore flexible pipe of PVCfixed to WHB/ urinals as waste pipe ( not less than 600mm) including PVC coupling complete all as specified.
48S&F in repair Gun metal , globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore dia. iron pipe and fixed complete all as specified.
49S&F Gun metal, in repair globe or gate valves, with iron wheel head, screwed both ends for 15 mm bore dia. iron pipe and fixed complete all as specified.
50S & F Neosprene rubber beading including taking down old rubber beading as in aluminium window and door shutter
51S&f for 12 mm thick toughned glass odinary qulity and glazing with neosprene beading, SS clip or cleats of any size any postition including taking down of existing unserviceable glass
52Repairing of existing aluminium door single/double leaf including oiling and greasing of floor springs,replecing of rubber beading if required,replacement of hinges,door stopper,handle,towerbolt of any size any type present at site on required basis,also including replacement of any membre of aluminium section i.e frame & shutters membre and 3-5 mm glass and making t he door and shutter serviceable complete all as specified.(Note:-Floor door springs and door closer where changed shall be measured and paid separately under appropriate items
53Repairing of existing toughend glass door single leaf including oiling and greasing of floor springs,replacement of hinges,handle,lock of any size any type present at site on required basis,also including replacement of any membre of aluminium section i.e frame & shutters membre and 12 mm glass and making the door and shutter serviceable complete all as specified.(Floor door springs where renewed shall not be measured & paid seperately it includes the rate of floor spring also)
54Supply & fixing in repair Double actionfloor spring hydraulically regu-lated made up of minimum 1.25 mm thick alu-minium alloysheet foun-dation box,main body with stainless steel cover, governing pivot made of mild steel heavy duty fixed.
55S&Fin repairs Aluminium body ( extruded section ) body Door closer hydraulically regulated, designation No. 2 , universal type , suitable for door shutters 701 to 850 mm in width and ofweight between 36 to 60 Kg and fixed
56S&F in repairfor 100 mm mild steel 4 lever mortice lock vertical type of size of brass body
57Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 20mm thick in cement mortor 1:4
58M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 350 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 10mm thick screed in CM 1:3
59Excavating in post holes each not exc. 0.5 cum getting out in soft / loose soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm, watering and removing surplus soil to a distance not exc. 50 m and depositing where directed
60M&L for PCC 1:4:8 type D-2as in foundation and mass concrete using 40 mm graded stone.
61M&L for providing cement concrete type B-1,1:2:4 (20 mm graded aggregate ) asin floor, kerbs /padding or similar work or mud stops rounded or chamferred on edges.
62M&L6-10mm thick walltilesin repairs Duracrete manufactured by M/S Intex Designer Tiles Pvt Ltd. or equivalent of other specified make ) as invertical surfacesset and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10mm thick screed in CM 1:3.
63Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water all as specified and directed.
6415mm thick rendering on brick work or concrete surfaces in CM 1:4 finished fair & even without extra cement, cement mortar mixed with WPC @ 3% of weight of cementNote: WPC measured & paid for separately
65M&L for rendering 10 mm thick onbrick work/ concrete surfacesin cement mortar 1:6 on fair faces finishedeven and smooth without using extra cement
66M&L rendering 5 mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3complete all as specified
67M&L for preparing surfaces, plastered orunplastered new surfaces of ceiling and applying three coats white wash all as specified and directed.
68Preparation of newly plastered surfaces and applying two coat of oil bound disemper over one coat of oil base primer all as specified on walls surface.Incl a coat of 2mm thick wall care putty.
69Preparation of newly plastered surfaces of walls and applying two coats of cement base paint of any tint/shade over a coat of primer all as specified.
70M&L applying two coats of Apex ( Asian Paint) / Weather coat (Berger) over newly plastered surface including preparation ofwall surface over and including 1mm thick wall care putty complete all as specified and directed by EIC.
71Preparation of new wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying two coat of synthetic enamel paint over a coat of pink primer all as specified.
72Preparation of new steel and iron based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified.
73Preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint all as specified.
74Preparation of old plastered or unplastered surfaces of walls by washing, rubbing down & stopping etc, and applying one coat of cement base paint of any tint/shade all as specified.
75Preparation of old plastered or unplastered surfaces of walls by washing, rubbing down & stopping etc, and applying one coat of distemper oil emulsion of any tint/shade all as specified.
76All as per item No 75 above but on ceiling.
77Preparation of old painted surfaces of steel of any description, not otherwise described over 10 cm width or girth, including knotting and stopping and applying one coat of synthetic enamel paint all as specified.
78Complete removal of existing treatment of walls and applying two coats of distemper oil emulsion over a coat of Birla or JK white wall puttyaverage thickness 2mm on old plastered surfaces including prepration all as specified and directed.
79M&L for brick work with sub class "B" bricks straight or curved on plan to any radius in half brick thick wall builtin cement mortar 1:4
80Dismantling wrought iron or mild steel work of any description not otherwise provided for
81M & L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Grade Fe- 410 (Gde E- 250) complete all as specified.
82M&L for filling joints between two panels with mix of 85/25 bitumen and sand in 1:3
83M&L 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as plinth protection/path and the like all as specified and directed.
84M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping,padding and bed block,wall through and the like including weathering slightly rounded or chamfered angles and throatingincluding necessary form work
85M&L 18-20mm thick machine cut Kota stone slab flooring with marble stone strips/ slab/ tiles as per design approved,over and including cement screed bed 20mm thick in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing complete
86M&L 18-20mm thick machine cut Kota stone slab as in skirting /riser over and including cement screed bed 10mm thick in CM 1:3and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing complete
87Grinding of old kota stone flooring uptomirror finish level including polisihig etc complete all as specified and directed.
88Dismantling floor, stone flooring, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises
89M & L for precast cement concrete Type B0,1:2:4 (using 12.5mm graded stone aggregates) louvres and jallies, 25mm thick (measured solid), including all mouldings and set in CM 1:4 complete all as specified and directed
90M&L for non skid ceramictiles of 7-8 mm (square or rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15mm thick screed in CM 1:6
91M&L Vitrified ceramic tiles 10mm thick (square/ractangular) Coloured polished tiles,area of each tile n.exc 0.38 sq m in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement and pigmentto match over and including 15 mm thick screeding in CM 1:6
92S & F in repair 20 mm dia fancy type drapery curtain rod made of mild steel duly PVC sleeved complete all as specified
93S & F Powder coated brackets for fixing curtain rod of any dia and fixed complete all as specified
94S & F Powder coated decorative any shape end cap for fixing with curtain rod of any dia and fixed complete all as specified
95Anti-Microbial Protection: These product hygiene coatings start the bio cidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years. This Hygiene coating are independently tested by leading universities to demonstrate resistance.Note : (Anti-Microbial Protection: Filling of all Joints and cavities and Sanded Flush to provide a joint less finish and then sprayed with a water based liquid plastic aseptic and self sterilizing wall coating system to a d.f.t. of 300 microns with primer. These hygiene coatings should start the biocidal action as soon as the microorganism land on the surface, and prevent the growth of mould, bacteria and yeasts ( Formally Liquid Plastic) (Note:- The work will be carried out in OT rooms in a peace-meal or very restricted permissible condition, quoted rates deemed to included for wastages of labour and material components accordingly)
96Conductive Flooring: 2mm thick Conductive flooring with carbon backing total thickness 2.00mm, total weight 3.000 g/m2 polyurethane reinforced ,scratch resistant, fireresistant,chemical resistant,slipresistant,antifungi&bacterialgrowth, dimensional stability 0.40%, staticelectrical charger < 2Kv , impact sound reduction approx +4bd, electrical resistant. Installation : Theflooring would be installed on a smooth, clean sub floor which should be free from any undulation .A copper strip/mesh should be layer under the tiles, with one earthing point for every 150 sft of area and good quality water based adhesive for fixing as per as manufacturers recommendation. Thermal Welding : The joints must be welds by the heat fusion process to get a seamless floor. The joints in the flooring should be sealed by using a PVC welding bar of matchingcolor to be supplied by the manufacturer, using a hot air gun for fusion of welding bar with flooring.The same application to be done for wall skirting up to max 150mm and coving to be provided using appropriate material and method including dismantling of existing unserviceable flooring.Make – Gerfloor/ Tarquet , France or equivalent (Note:- The work will be carried out in OT rooms in a peace-meal or very restricted permissible condition, quoted rates deemed to included for wastages of labour and material components accordingly)
97S & F for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 1000 litres including dismantling of unserviceable existing water tanks of capacity 500 ltrs and taken as credit
98S & F for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 1000 litres including dismantling of unserviceable existing water tanks of capacity 1000 ltrs and taken as credit
99S & F for Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 2000 litres including dismantling of unserviceable existing water tanks of capacity 2000 ltrs and taken as credit
100S&F in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball , suitable for 20 mm bore pipe, screwed for iron pipe and fixed. .(Minimum weight 20mm-210gms)complete all as specified.
101S&F in repair vitreous china Europeon Water Closet (one piece cascade set WC) of specified make with flushing cistern & white seat cover complete all as specified & directed.
102S & F in repair brass CP wall mixer (3 in 1) with hand shower completeall as specified
103S&F in repair for auto censor swan neck pillar tap with complete accessories and electrical fittings including removal of existing unservicable tap and fix new censor tap including intallation of new electric point as requrired and making good the wall tiles, replacement of GI pipe as required complete all as specified and directed.
104S & F in repair for 20mm dia curtain rails with bracketsand end cap each sides inwindow/doors, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed. (Each rail will be measured)
105Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed. (Capacity of tank 500 ltrs)
106Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed. (Capacity of tank 1000 ltrs)
107Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed. (Capacity of tank 2000 ltrs)
108Taking up or down steel tubing and connections , including cleaning for re-fixing or removal of store, 15 mm bore all as specified.
109Taking up or down steel tubing and connections , including cleaning for re-fixing or removal of store, 20 mm bore all as specified.
110Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.)15 mm nominal bore complete all as specified
111Refixing old steel tubing and connections in new or old position ( walls, ceiling , floors, etc.)20 mm nominal bore complete all as specified
112M&L 15 mm nominal boreMild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
113M&L 20 mm nominal boreMild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
114Temporarily blocking of inlet of septic tanks/manhole with suitable wooden plugs/gunny bags and pumping/bailing out effluent and taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/manholes. complete and cleaning the septic tank/manholes with waterby mechanically/manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by E-I-C. (NOTE: Depth of manhole/SOAK WELL/SEPTIC TANK exc 0.5 to 1.5M from below GL)
115Temporarily blocking of inlet of septic tanks/manhole with suitable wooden plugs/gunny bags and pumping/bailing out effluent and taking out/removing the accumulated sludge soil sewage/any other foreign/foul materials etc (solid/semisolid) from the septic tanks/manholes. complete and cleaning the septic tank/manholes with waterby mechanically/manually including taking out the blocking arrangements of inlet and making the system functional all as specified and directed by E-I-C. (NOTE: Depth of manhole/SOAK WELL/SEPTIC TANK exc 1.50M to 4.50M from below GL)
116Temporarily blocking of sewage line with suitable wooden plugs/gunny bags and cleaning the same by rod-ding and removing the sludge alongwith brick bats/stones/broken bottles/any other foreign materials etc complete and cleaning the sewage line with water by mannually/mechanilly as directed by EIC, and taking out the blocking arrangements of inlet and making the system functional all as specified and directed for 150 mm bore size of pipe lines
117Same as item No: 22 above but 200 mm bore
118PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in concrete bed toSGSW pipes of 200 mmbore dia incl packing under & haunching against the sides of pipes after they are laid &tested.
119PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in concrete bed toSGSW pipes of 150 mmbore dia incl packing under & haunching against the sides of pipes after they are laid &tested.
120PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in concrete bed toSGSW pipes of 200 mmbore dia incl packing under & & completely surounding pipes with conrete after they are laid and tested.
121PCC 1:3:6 type C2 using 40 mm graded stone aggregate as in concrete bed toSGSW pipes of 150 mmbore dia incl packing under & & completely surounding pipes with conrete after they are laid and tested.
122Salt-glazed stone ware drain (SGSW) pipe grade "A" 150 mm bore dia laid in trenches & jointed in CM 1:1 including dismantling of existing unserviceable pipes complete all as specified and directed
123Salt-glazed stone ware drain (SGSW) pipe grade "A" 200 mm bore dia laid in trenches & jointed in CM 1:1including dismantling of existing unserviceable pipes complete all as specified and directed
124M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed including dismantling and removal of existing paver blocks
125M&L for exterior grade outdoor coloured floor tiles (heavy duty) of tactileseries of size 300x300x10mm of Make Johnson endura or equivalent make bedded over and including 20mm thick screed bed in CM 1:6 and jointed in cement mortar to match the colour of floor complete all as specified and directed including dismantling of existing tiles
126M&L Chequered cement concrete coloured tiles 30 cmx30cmx20 mm thick with coloured cement and pigment , set, jointed and pointed in neat cement slurry over 20mm thick screed bed in CM 1:4 as in floors complete all as specified.( (Note : Screed bed will not be measured and paid separately) including dismantling of existing tiles
127M & L for 75mm thick plain cement concrete type D- 2, 1:4:8 (40mm graded aggregate)
128M & L for Hardcore of gauge n exc. 63mm, of broken bricks, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface
129Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out inhard/dense soil
130Removing of soil excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
131Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
132M&L TMT 8mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming Fe- 500.
133M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping,padding and bed block,cover slab wall through and the like including weathering slightly rounded or chamfered angles and throatingincluding necessary form work
134Cutting into existing manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for all forming branch channel (1/2) round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching
135S &F in repair for 110mm bore (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors/fix to wall including taking down of existing unservicebale pipes
136All as per item No 41 here-in-before but dia of 75mm
137S & F in repair for (SWR)75mm dia floor trapplain with grating including jointing with solvent cement
138S&F in repair for 110mm bore PVC (SWR)vent cowl
139S&F in repair for 110mm bore PVC (SWR)bend of any radius
140All as per item No 45 here-in-before but dia of 75mm
141S&F in repair forPVC (SWR) 125/110 mm gully trap with grating including jointing with solvent cement.
142M & L for PCC 1:3:6 type C2 (using 40mm graded stone aggreages) Concrete bed to 110mm bore PVC drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested;
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail