Paschimanchal Vidyut Vitran Nigam Limited has published Tender For Laying Of Additional 11 Kv Xlpe Cable For Power Transformer No 1 & 4 At Substation Jain Bagh & Laying Of Xlpe Cable From 11 Kv Control Panel To Double Pole Of Substation Husain Basti Under Approved Electric Urban Distribution Division-Ii, Saha. Submission Date for this Tender is 28-05-2024. Power Transformer Tenders in saharanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 10-May-2024 | Date extended 15-05-2024 | Date | 15-05-2024 |
2 | 15-May-2024 | Date extended 21-05-2024 | Date | 21-05-2024 |
3 | 21-May-2024 | Date extended 28-05-2024 | Date | 28-05-2024 |
FileName | File Description | File Size |
8dfa43e0-c767-4a47-8d3a-efb32c0e173e.html | Tender Notice | 0 KB |
BOQ_1595866.xls | Tender Document | 0 KB |
tenderdocument.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Tendernotice_2.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Safe Carriage of other line metrial from PVVNL, Store to site including loading & unloading both ends. |
2 | Safe Carriage of 11KV XLPE (3x300sqmm) from PVVNL, Store to site including loading & unloading both ends. |
3 | Safe Carriage of 11KV XLPE (3x185sqmm) from PVVNL, Store to site including loading & unloading both ends. |
4 | Fixing 11KV Jointing Kit indoor for 11KV XLPE (3x300sqmm) as per resspo norms. |
5 | Fixing 11KV Jointing Kit outdoor for 11KV XLPE (3x300sqmm) as per resspo norms. |
6 | Fixing 11KV Jointing Kit indoor for 11KV XLPE (3x185sqmm) as per resspo norms. |
7 | Fixing 11KV Jointing Kit outdoor for 11KV XLPE (3x185sqmm) as per resspo norms. |
8 | Laying of 11KV XLPE cable (3x300sqmm) in open trench as per Resspo norms. |
9 | Providing & Laying HDPE Pipe6" dia after digging trench for sutaible 11 KV XLPE Cable (3x185 sqmm) as per resspo Norms |
10 | Laying of 11KV XLPE cable (3x185sqmm) in HDPE pipe as per Resspo norms. |
11 | Providing & Fixing Holding Clamp as per Resspo norms. |
12 | Providing & Fixing Nut & bolts as per Resspo norms. |
13 | Providing & Fixing G.I. Pipe as per Resspo norms. |
14 | Errection of 11 kv XLPE cable (3x300) sqmm in AIR& make looping as per resspo norms. |
15 | Errection of 11 kv XLPE cable (3x185) sqmm in AIR on D/P & make looping including fixing with clamp as per resspo norms. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail