Tender For Repairing Of Vcb Panel And Other Instrument Etc Work In Area Of Edd-Ii Hapur In Business Plan, 1 For Repairing/Replacment Of Jarjar Vcb And Ohther Associated Works, In Business Plan (2024-25), In The Area Ofedd-Ii Hapur, Under Edc., Hapur. (T, hapur-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For Repairing Of Vcb Panel And Other Instrument Etc Work In Area Of Edd-Ii Hapur In Business Plan, 1 For Repairing/Replacment Of Jarjar Vcb And Ohther Associated Works, In Business Plan (2024-25), In The Area Ofedd-Ii Hapur, Under Edc., Hapur. (T. Submission Date for this Tender is 24-05-2024. Circuit Breakers Tenders in hapur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43289690
Corrigendum : Tender For Repairing Of Vcb Panel And Other Instrument Etc Work In Area Of Edd-Ii Hapur In Business Plan, 1 For Repairing/Replacment Of Jarjar Vcb And Ohther Associated Works, In Business Plan (2024-25), In The Area Ofedd-Ii Hapur, Under Edc., Hapur. (T
Open Tender
Indian
Uttar Pradesh
hapur
24-05-2024

Tender Details

Tender For Repairing Of Vcb Panel And Other Instrument Etc Work In Area Of Edd-Ii Hapur In Business Plan, 1 For Repairing / Replacment Of Jarjar Vcb And Ohther Associated Works, In Business Plan ( 2024-25 ) , In The Area Ofedd-Ii Hapur, Under Edc., Hapur. ( Third Party Inspection Of The Quality Of All Works Will Be Conducted By The Department. ) 2 Carriage Of All Petty Material Of Estimate, From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station / Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 3 Carriage Of All Cable / Conductor Of Estimate From Je Store / Ctr / Esc, Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. 4 Carriage Of New 11Kv Incoming Vcb-11No., And 11Kv Outgoing Vcb-30Nos., From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 5 Carriage Of 33Kv Ct Outdoor 33Kv Ctr 200 / 100 / 1, From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 6 Carriage Of 33Kv Vcb 750Mva-1250A, From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 7 Carriage Of 33Kv Vcb 750Mva-800A, From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 8 Carriage Of 33Kv Vcb 1200A, From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 9 Carriage Of 33Kv Control Pannel For Double Circuit From Electricity Store Center, Hapur To 33 / 11Kv Sub-Station With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 10 Dismantling Of Old & Jarjar 11Kv Incoming / Outgoing Vcb, From Existing Place In Control Room And Shifting The Same Outside The Control Room At 33 / 11Kv Sub-Stations, Including Removal All Connections, As Per Direction Of Site Incharge. 11 Dismantling Of Old & Jarjar 33Kv Incoming / Outgoing Vcb, From Existing Place In Control Room And Shifting The Same Outside The Control Room At 33 / 11Kv Sub-Stations, Including Removal All Connections, As Per Direction Of Site Incharge. 12 Carefully & Safely Shifting Of 11Kv Incoming Vcb-11Nos. & 11Kv Outgoing Vcb-27Nos., From Outside To Inside The Switchgear Room At The Place Of Removed VcbS And Erection / Installation Of 11Kv VcbS After Fixing Of Anchor Gi Nuts & Bolts Of Proper Size For Completion Of Energisation Work By Providing Required Fixing Material, As Per Respo / Drawing Norms, And As Per Direction Of Site Incharge. 13 Carefully & Safely Shifting Of 33Kv Vcb 750Mva-1250A From Outside To Inside The Switchgear Room At The Place Of Removed VcbS And Erection / Installation Of 33Kv VcbS After Fixing Of Anchor Gi Nuts & Bolts Of Proper Size For Completion Of Energisation Work By Providing Required Fixing Material, As Per Respo / Drawing Norms, And As Per Direction Of Site Incharge. 14 Carefully & Safely Shifting Of 33Kv Vcb 750Mva-800A From Outside To Inside The Switchgear Room At The Place Of Removed VcbS And Erection / Installation Of 33Kv VcbS After Fixing Of Anchor Gi Nuts & Bolts Of Proper Size For Completion Of Energisation Work By Providing Required Fixing Material, As Per Respo / Drawing Norms, And As Per Direction Of Site Incharge. 15 Carefully & Safely Shifting Of 33Kv Vcb 1200A From Outside To Inside The Switchgear Room At The Place Of Removed VcbS And Erection / Installation Of 33Kv VcbS After Fixing Of Anchor Gi Nuts & Bolts Of Proper Size For Completion Of Energisation Work By Providing Required Fixing Material, As Per Respo / Drawing Norms, And As Per Direction Of Site Incharge. 16 Mounting, Placing And Connecting Of All Connections Of 33Kv Ct Outdoor 33Kv Ctr 200 / 100 / 1, And Completion Work Properly By Providing Required Matrial, As Per Respo Norms Andas Per Direction Of Site Incharge. 17 Erection / Installation Of 33Kv Control Pannel Double Circuit After Fixing Of Anchor Gi Nuts & Bolts Of Proper Size For Completion Of Work By Providing Required Material, As Per Respo / Drawing Norms And As Per Direction Of Site Incharge. 18 Installation Of Battery Set And Completion Work Properly As Per Respo Drawing / Norms, And As Per Direction Of Site Incharge. 19 Installation Of Battery Charger Set And Completion Work Properly As Per Respo Drawing / Norms, And As Per Direction Of Site Incharge. 20 Erection & Fixing Of 33Kv. Fuse Set On Stp / Pcc Pole, By Providing All Required Fixing Materials As Per Respo / Norms And As Per Direction Of Site Incharge. 21 Erection And Fixing Of 33Kv Lightening Arrestor By Providing All Fixing Materials And Completion Work Properly As Per Respo Drawing / Norms And As Per Direction Of Site Incharge. 22 Erection And Fixing Of 33Kv Line Isolastor By Providing All Fixing Materials And Completion Work Properly As Per Respo Drawing / Norms And As Per Direction Of Site Incharge. 23 Erection And Fixing Of 33Kv Bus Isolastor By Providing All Fixing Materials And Completion Work Properly As Per Respo Drawing / Norms And As Per Direction Of Site Incharge. 24 Laying Of 11Kv Ht Xplpe Cable 3X300sqmm., And Completion Of Work Properly As Per Respo / Norms, Including By Providing Required Fixing Materials, As Per Direction Of Site Incharge. 25 Laying Of Copper Control Cable 4X2.5Sqmm., And Completion Of Work Properly As Per Respo / Norms, Including By Providing Required Fixing Materials, As Per Direction Of Site Incharge. 26 Laying Of Copper Control Cable 2X2.5Sqmm., And Completion Of Work Properly As Per Respo / Norms, Including By Providing Required Fixing Materials, As Per Direction Of Site Incharge. 27 Erection And Fixing Of Structur For Suitable Of Ct Outdoor / 33Kv Vcb After Fabrication Of Channel / Angle, Including By Providing Fixing All Materials And Completion Work Properly, As Per Direction Of Site Incharge 28 Carriage Of Old And Jarjar 11Kv Incoming Vcb From 33 / 11Kv Sub-Station / Site Of Work To Electricity Store Center, Hapur With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 29 Carriage Of Old And Jarjar 33Kv Incoming Vcb From 33 / 11Kv Sub-Station / Site Of Work To Electricity Store Center, Hapur With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 30 Dismantling Work And Carriage Of Old And Jarjar Scrap Battery Set-180Kg., And Iron Scrap-220Kg. From 33 / 11Kv Sub-Station / Site Of Work To Electricity Store Center, Hapur With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. 31 Jumpering And Line Energisation Work Properly As Per Respo / Norms And As Per Direction Of Site Incharge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-May-2024 exte date Date 15-05-2024
2 15-May-2024 date exten Date 20-05-2024
3 20-May-2024 extesion date Date 24-05-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 19500.0 /-
Tender Value
INR 19.02 Lakhs /-

BOQ Items

Name of Work: FOR REPAIRING/REPLACMENT OF JARJAR VCB AND OHTHER ASSOCIATED WORKS (24 NOS. WORKS), IN BUSINESS PLAN (2024-25), IN THE AREA OFEDD-II HAPUR, UNDER EDC., HAPUR.
Sl. No. Item Description
1FOR REPAIRING/REPLACMENT OF JARJAR VCB AND OHTHER ASSOCIATED WORKS, IN BUSINESS PLAN (2024-25), IN THE AREA OFEDD-II HAPUR, UNDER EDC., HAPUR. (Third party inspection of the quality of all works will be conducted by the department.)
2Carriage of all petty material of estimate, from Electricity store center, Hapur to 33/11KV Sub-Station/site of work with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
3Carriage of all cable/conductor of estimate from JE Store/CTR/ESC, Hapur to site of work, including loading & unloading at both ends, as per direction of site incharge.
4Carriage of new 11KV incoming VCB-11No., and 11KV outgoing VCB-30Nos., from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
5Carriage of 33KV CT Outdoor 33KV CTR 200/100/1, from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
6Carriage of 33KV VCB 750MVA-1250A, from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
7Carriage of 33KV VCB 750MVA-800A, from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
8Carriage of 33KV VCB 1200A, from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
9Carriage of 33KV control Pannel for double circuit from Electricity store center, Hapur to 33/11KV Sub-Station with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
10Dismantling of old & jarjar 11KV incoming/outgoing VCB, from existing place in control room and shifting the same outside the control room at 33/11KV Sub-Stations, including removal all connections, as per direction of site incharge.
11Dismantling of old & jarjar 33KV incoming/outgoing VCB, from existing place in control room and shifting the same outside the control room at 33/11KV Sub-Stations, including removal all connections, as per direction of site incharge.
12Carefully & safely shifting of 11KV incoming VCB-11Nos. & 11KV outgoing VCB-27Nos., from outside to inside the switchgear room at the place of removed VCB"s and erection/Installation of 11KV VCB"s after fixing of anchor GI nuts & bolts of proper size for completion of energisation work by providing required fixing material, as per RESPO/Drawing Norms, and as per direction of site incharge.
13Carefully & safely shifting of 33KV VCB 750MVA-1250A from outside to inside the switchgear room at the place of removed VCB"s and erection/Installation of 33KV VCB"s after fixing of anchor GI nuts & bolts of proper size for completion of energisation work by providing required fixing material, as per RESPO/Drawing Norms, and as per direction of site incharge.
14Carefully & safely shifting of 33KV VCB 750MVA-800A from outside to inside the switchgear room at the place of removed VCB"s and erection/Installation of 33KV VCB"s after fixing of anchor GI nuts & bolts of proper size for completion of energisation work by providing required fixing material, as per RESPO/Drawing Norms, and as per direction of site incharge.
15Carefully & safely shifting of 33KV VCB 1200A from outside to inside the switchgear room at the place of removed VCB"s and erection/Installation of 33KV VCB"s after fixing of anchor GI nuts & bolts of proper size for completion of energisation work by providing required fixing material, as per RESPO/Drawing Norms, and as per direction of site incharge.
16Mounting, Placing and connecting of all connections of 33KV CT Outdoor 33KV CTR 200/100/1, and completion work properly by providing required matrial, as per RESPO Norms andas per direction of site incharge.
17Erection/Installation of 33KV Control Pannel double circuit after fixing of anchor GI nuts & bolts of proper size for completion of work by providing required material, as per RESPO/Drawing Norms and as per direction of site incharge.
18Installation of Battery set and completion work properly as per RESPO Drawing/Norms, and as per direction of site incharge.
19Installation of Battery Charger set and completion work properly as per RESPO Drawing/Norms, and as per direction of site incharge.
20Erection & Fixing of 33KV. Fuse set on STP/PCC Pole, by providing all required fixing materials as per RESPO/Norms and as per direction of site incharge.
21Erection and Fixing of 33KV Lightening Arrestor by providing all fixing materials and completion work properly as per RESPO Drawing/Norms and as per direction of site incharge.
22Erection and Fixing of 33KV Line Isolastor by providing all fixing materials and completion work properly as per RESPO Drawing/Norms and as per direction of site incharge.
23Erection and Fixing of 33KV Bus Isolastor by providing all fixing materials and completion work properly as per RESPO Drawing/Norms and as per direction of site incharge.
24Laying of 11KV HT XPLPE Cable 3x300Sqmm., and completion of work properly as per RESPO/Norms, including by providing required fixing materials, as per direction of site incharge.
25Laying of Copper Control Cable 4x2.5Sqmm., and completion of work properly as per RESPO/Norms, including by providing required fixing materials, as per direction of site incharge.
26Laying of Copper Control Cable 2x2.5Sqmm., and completion of work properly as per RESPO/Norms, including by providing required fixing materials, as per direction of site incharge.
27Erection and fixing of Structur for suitable of CT Outdoor/33KV VCB after fabrication of Channel/Angle, including by providing fixing all materials and completion work properly, as per direction of site incharge
28Carriage of old and jarjar 11KV incoming VCB from 33/11KV Sub-Station/ site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
29Carriage of old and jarjar 33KV incoming VCB from 33/11KV Sub-Station/ site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
30Dismantling work and carriage of old and jarjar scrap Battery set-180Kg., and Iron scrap-220Kg. from 33/11KV Sub-Station/ site of work to Electricity store center, Hapur with loading and unloading at both ends on Kachha Packka road, as per direction of site incharge.
31Jumpering and line energisation work properly as per RESPO/Norms and as per direction of site incharge.
Disclaimer :