Tender For Provision Of Lltr Infrastructure At Af Stn Palam And Special Repair/Replacement Of Ht/Ug Cable With Allied Works At Sekhon Vihar Under Ge (Af) Gurgaon No.1, gurgaon-Haryana

Military Engineer Services-MES has published Tender For Provision Of Lltr Infrastructure At Af Stn Palam And Special Repair/Replacement Of Ht/Ug Cable With Allied Works At Sekhon Vihar Under Ge (Af) Gurgaon No.1. Submission Date for this Tender is 18-05-2024. Cable Laying Tenders in gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43288879
Tender For Provision Of Lltr Infrastructure At Af Stn Palam And Special Repair/Replacement Of Ht/Ug Cable With Allied Works At Sekhon Vihar Under Ge (Af) Gurgaon No.1
Open Tender
Indian
Haryana
gurgaon
18-05-2024

Tender Details

Tender For Provision Of Lltr Infrastructure At Af Stn Palam And Special Repair/Replacement Of Ht/Ug Cable With Allied Works At Sekhon Vihar Under Ge (Af) Gurgaon No.1

Key Value

Document Fees
INR 1000 /-
EMD
INR 144900.0 /-
Tender Value
INR 79.95 Lakhs /-

BOQ Items

Name of Work: PROVN OF LLTR INFRASTRUCTURE AT AF STN PALAM AND SPECIAL REPAIR/REPLACEMENT OF HT/UG CABLE WITH ALLIED WORKS AT SEKHON VIHAR UNDER GE (AF) GURGAON NO.1
Sl. No. Item Description
1Schedule ‘A’Part-I Job No. 13BRD/CAP-06/2023-2024
2Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
3Returning filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified and as directed.
4Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.
5Supply and laying sand in trenches for protection of cable sand cushioning to cable 8 cm thick below cable and 15 cm thick above cable in layers all as specified and as directed.
6M&L for brick protection with sub class "B" old bricks laid dry flat 23cm in width over sand cushioning in trenches as perpendicular to the direction of underground cable complete all as specified and as directed.
7Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables, 1100 volts grade, cross-sectional area 95 Sqmm, 3.5 core.
8Supply, Installation,Testing and Commisioning of waterless maintenance free earthing based on pre-casted conductive earthing electrode dimensions lengthx dia.: 10000x80 using 17.2 mm solid conductors upto bore depth level with copper bonded terminals, lugs and latches. Conduction : Non Ionic movement of ions with multipoint dissipitaion contacts exceeds grade 25 concrete with Ph neutral internal material with eco friendly having relative density of 890-990 kg/m3. Earthing is having 3000 times more effective than Bentonite. The earthing electrolytic corrosion resistance is > 86% reduction in corrosion with short circuit current: Peak: 40 KA RMS: 22 Kilo amps fro 1 second also having mechanical strength of >grade 25 concrete. Th earthing high fault current test withstand of 1686 V for 500ms. The earthing standards as per IEEE 80:2000 & BS 7430, Resistance value is less than 1 ohm. The heavy duty earth pit cover will be provided. Waranty 3 years.
9Supply & fix wall mounted air curtain with sensor 6 ft, not less than 2000 CFM for entry door all as specified and directed
10Supply, Installation, Testing and Commissioning of Digital earthing system. Material : Copper,brand :ECA3G, Frequency : 50 Hz, Supply : 230 V, Display : LCD, Operating temp : -40 to 80 degrees built in surge counter.
11S&F Copper strip ( PVC Insulated sleeves) of size25 width x 06 mm thick as in earth continuity conductor fixed to wall or buried in ground or any other situation for loop earthing as required at site
12M&L for sub main wiring of four run with 06 Sqmm single core PVC insulated, FRLS,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-and-caping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including two run of 6.0 Sqmm single core PVC insulated, FRLS ,flexible copper cable as earth continuity conductor in green color all as specified and as directed.
13M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-and-caping of size 25 x 16 mm medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS ,flexible copper cable as earth continuity conductor in green color all as specified and as directed.
14M&L for point wiring for 15 Amp switch socket for power point complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing-n- copping and its accessories, cadmium screws and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing the specified and directed.
15Supply, Installation, Testing and Commissioning of 80 ltr capacityDehumidifier range:25%-60%, Input voltage:110-220V AC/5V 2A ,DC” Power :5W/H, one Quantity of Controller PC , LCD Display and2 foot heightAdjustment system
16Supply & fix sheet metal enclosurefor415 volts IP40-32 Amps with 3phase ,Neutral and earth including industrial typethree pin and earth plug top with socketcomplete as well as specified and directed.(MCB will be measured and paid separeately)
17Supply & fix sheet metal enclosurefor220 volts 20 Amps with a three pin and earth plug top with socket and one double pole MCB20 amps complete as well as specified and directed.
18S&F TPN 415 Volts 4 way double doortype DB complete all as specified and directed.
19S & F MCB TPN 63 Amps, 415 Volt, 10 KA, "C" series type complete all as specified and as directed.
20S & F MCB TPN 32 Amps, 415 Volt, 10 KA, "C" series type complete all as specified and as directed.
21S & F MCB SP 6-32 Amps, 240 Volt, 10 KA, "B" series type complete all as specified and as directed.
22S&F twin socket modular type heavyduty out let 6 pin 6/16 Amps 2 module,
23S&Fswitch Modular type 16 Amps , single pole one way 240 volts one module as specified.
24Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thick (below or above ground level) complete all as specified and directed.
25Demolition of reinforced cement concrete (RCC) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
26Dismantling of brick work, built in cement mortar or lime mortar including all quoins, arches, pillars, etc., but excuding ashlar facings, dressed stonework and precast concrete articles, complete in all respect as specified and directed.
27M&L for surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
28Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in soft/loose soil complete all as specified and directed.
29Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
30Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
31M&L for PCC (1:4:8) type D2 (using 40mm crushed and graded stone aggregate)as in foundaion and mass fillingcomplete in all respect as specified and directed
32M&L for brick work with subclass "B" bricks straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
33M & L forPCC (1:2:4) typeB1 (using 20mm graded stone aggregates) in coping including necessary form work etc.complete all as specified and directed.
34S&F mild steel work in plates (plain or chequered) channels, squares cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment, complete in all respect as specified and directed.
35M & L for mild steel iron frame for door, window using joist, channel, angle, tee, tubes, flat sections, fixed independently, without connecting plates, etc. Fe 410 -W (Gde-E- 250) quality-Acomplete in all respect as specifified and directed.(MS hinge shall be paid under supply only item)
36M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
37Excavation in post holes (or similar holes) in soft/loose soil each not exc 0.50 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50 m and making good surface.
38M&L for cement concrete type B-2, 1:2:4 mix (40 mm graded stone aggregate) in foundation, filling & mass concrete, complete all as specified and as directed.
39S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality "A") complete all as specified and directed.
40S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. Note-The measurement shall be carried out as in plain
41Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete in all respect all as specified and directed.
42M&L providing 50 mm thick cement concrete type B1,1:2:4 (20mm graded aggregate) as in floor finish complete all as specified and as directed.
43M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed bed in cement mortar 1:4, laid and jointed in neat cement slury and pointed in white cement with pigment to mathc the shade of the tiles, complete in all respect as specified and as directed.
44M&L for cement concrete work in pavement hard standing of flexural strenght 40 Kg/ per sqcm in field using 400 kg of cement per cum, thickness of concrete 10 cm, complete in all respect as specified and as directed.
45M&L for brick work with sub-class "B" old size bricks of class designation (CD) 75, straight or curved on plan to any radius in half brick thick walls built in cement mortar (CM) 1:6, complete in all respect as specified and directed.
46Taking down cement mortar plaster on brick or stone wall or concrete surfaces etc., including raking out joints, hacking for key, scrubbing down with water etc. complete in all respect as specified and directed.
47M&L for 15 mm thick cement plaster in CM 1:4 on brick or concrete surfaces of drain incl finished the surfaces even and smooth without using extra cement complete all as specified and directed.
48M & L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:6) finished even and smooth without using extra cement complete in all respect as specifified and directed.
49M&L for preparation of newly undecorated plastered surface of wall and applying two coats of dismper oil emulsion and wall care putty . complete in all respect as specified and directed. (Notes : all holes/ cracks to be filled with birla putty and making good to old surface)
50M&L for two coats of cement base paint on newly plstered surface over a coat of chalk whiting including all prepration, complete in all respect as specified and as directed.
51M&L forpreparation of newplastered surfaces of walland applying two coats of white washover a coat of chalk whitening complete all as specified and directed.
52Taking down chowkats or frames and shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each, complete in all respect as specified and directed.
53S&F for Anodised aluminium frame (minimum 50 micron powder coating) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
54S&F extruded anodized aluminium partition and door shutter aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. directed by EIC cut to size jointed together with cadmiums plated steel screws including rubber beading or gasket for aluminium section and for fixing glass and all necessary fittings screws plug for fixing screws locking arrangement, handles, tower boltetc complete all as specified and directed by EIC.
55S&F 5.5 mm thick sheet glass selected quality and glazing with oil putty in squareds exc 0.5 sqm in each pane, complete in all respect as specifieid and directed.
56S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete in all respect as specifieid and directed.
57S&F 4 lever brass Mortice lock, vertical type, size 100 mm, complete in all respect as specifieid and directed.
58S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete in all respect as specifieid and directed.
59Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete in all respect as specified and as directed by Engr-in-Charge.
60Providing & fixing false ceiling With fully perforated 12mm thick micro tegular edged at all heights with GRG ( Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture,design and patters having moisture content lessthan 2%. Humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987,Noncombustible as per BS 476 (part4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15x32mm of length 3000mm,cross-T of size 15x32 of length 1200mm and secondary intermediate cross-T of size 15x32mm of length 600mm to from grid module of size 600x600mm, suspended from ceiling using galvanized mild steel items (galvenizing @ 80 grams per sqm)i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm lenght and L shape level adjuster of size 85x25x2mm Galvenised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work complete in all respect as per specifications, drawing and as per directions of the Engineer-in-charge
61S&F 12mm thick prelaminated particle board,interior grade, prelaminated both sides with decorative choice laminations fixed with screws in aluminium partition and door etc., complete all as specified and as directed.
62Supply only 5 mm thickglass ordinary quality ineach pane for aluminimum slidingwindows complete all as specified.
63Dismantling wrought iron or mild steel work of any description not otherwise provided for
64M&L for preparation of newly undecorated plastered Surfaces of any description over 10cm girth or width, not otherwise described of wall and applying two coats of black Bituminous Paint with one coat of priming paint plaster coat complete in all respect as specified and directed. (Notes : all holes/ cracks to be filled with birla putty and making good to old surface)
65Mechanical compactor of CRAC TATA sheet having 20 guage body & 20 guage of shelf with powder coated body, adjustable shelf center locking heavy duly and durable tracks and ergonomically designed handles, size 1980 Hx900 Wx400 D mm for single face fixed and single face moblile as well and 190x800x900mm for double face mobile unit.
66ESD safe revolving Chair
67ESD safe bench of 6 feet by 3 feet
68Schedule ‘A’ Part-II Job No. NDS/SR(E&M)/10/2023-24
69Taking up or down cable XLPE insulated screened PVC bedded, galvanized steel strap or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 240 sqmm, 3.0 core for taking creditall as specified and as directed.
70Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 240 sq mm.
71Material and labour for HT Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm
72Material and Labour for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm
73Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc, complete all as specified and as directed by Engineer-in-Charge.
74Returning, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid tested complete all as specified and as directed by Engineer-in-Charge.
75Removal of excavated surplus soil to a distancen exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge.
76M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and 18cm punnd thickness shall be paid complete all as specified and as directed.
77Supply and laying reinforced precast concreate cable cover, HV , flat size 450mm x 230mm x 50 mm for HT cable protection complete.
78M&L complete for drilling hole manually underhard standing /road for laying ofpipe for protection of cable etc and making good the disturbed surface to the existing if any, complete all as specified and directed by Engineer-in-Charge.
79Supply and laying GI tube light grade 100 mm bore pipe with ISI marked fittings complete all as specified and directed by Engineer-in-Charge.
80M&L for demolition of cement Concrete in any descriptiong below or above ground level complete all as specified and directed.
81M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregates for repairing / filling in road cuts/ hard standing etc all as specified and as directed.
82Schedule of Credit
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail