Tender For Construction Of Certain Technical And Domestic Infrastructure At Af Stn Jorhat (Phase -Ii), chabua-Assam

Military Engineer Services-MES has published Tender For Construction Of Certain Technical And Domestic Infrastructure At Af Stn Jorhat (Phase -Ii). Submission Date for this Tender is 08-06-2024. Infrastructure Work Tenders in chabua Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43288843
Tender For Construction Of Certain Technical And Domestic Infrastructure At Af Stn Jorhat (Phase -Ii)
Open Tender
Indian
Assam
chabua
08-06-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Construction Of Certain Technical And Domestic Infrastructure At Af Stn Jorhat (Phase -Ii)

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 56.85 Crore /-

Attachment

FileName File Description File Size
791e8f59-d87b-4b34-9978-4e68727d0eac.html Tender Notice 0 KB
BOQ_729911.xls Tender Document 0 KB
Main_Drg.rar Tender Document 0 KB
TD1.rar Tender Document 0 KB
TD2.rar Tender Document 0 KB
TENDER.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:CONSTRUCTION OF CERTAIN TECHNICAL AND DOMESTIC INFRASTRUCTURE AT AF STN JORHAT(PHASE -II)
Sl. No. Item Description
1NOTE (Applicable for all Parts/ Items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
2SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced Schedule is given in tender documents
3SCHEDULE "A" PART-II (EARTH WORK AND EXCAVATION) Details of pre-priced Schedule is given in tender documents
4SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents.
5SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of pre-priced Schedule is given in tender documents.
6SCHEDULE "A" PART-V (ROAD/HARDSTANDING/SLAB CULVERT) Details of pre-priced Schedule is given in tender documents.
7SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of pre-priced Schedule is given in tender documents.
8SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of pre-priced Schedule is given in tender documents.
9SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of pre-priced Schedule is given in tender documents
10SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Details of pre-priced Schedule is given in tender documents
11SCHEDULE "A" PART-X (LIGHTENING PROTECTION) Details of pre-priced Schedule is given in tender documents
12SCHEDULE "A" PART -XI (MISCELLANEOUS ITEMS)Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col." F " signifies this fact only.
13S & F modular metal flush box with modular white cover plate with frame, 8 module complete all as specified and directed .
14S & F modular metal flush box with modular white cover plate with frame, 6 module complete all as specified and directed .
15S & F modular metal flush box with modular white cover plate with frame, 3 module complete all as specified and directed .
16S&F LED light fittings 4 feet, 1 x 20 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
17S&F LED light fittings with high output diffuser 2 feet, 1 x 10 W, 220 V AC decorative type with driver including LED lamp, connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
18S&F LED light fittings 4 feet, 1 x 40 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
19S&F sheet metal enclosure for MCB DB single pole and neutral 6 way with 200 Amps rated bus bar, neutral link, dinrail suitable for mounting MCB"s 240 volts double door type complete all as specified.and directed Note:- MCB"s are measured and paid in separate items
20S&F MCB SP63 Amps (C-Curve), breaking capacity 10 kA, 240 voltscomplete all as specified and directed.
21S&F Energy efficient five star rated, 26 to 32Watts, with three blades ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current(BLDC) without remote type with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice)including provision of three core flexible copper wire ofsuitable sizefrom ceiling rose to ceiling fancomplete in all respect all as specified and directed.
22S&Fexhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 300mm sweep, 900/950 RPM, copper wound, 3 blade, double ball bearing,heavy duty type with suitable metallic louver, blades, frameand flexible three core copper conductor cable of suitable size for connecting with ceiling rose completeall as specified and as directed.
23M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plateNo-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 15 mm (light grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b)PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c)Excavation/earthwork is deemed to be included in the quoted rate.]
24Material & Labourfor 300 mm thick(compacted thickness) GSB (Granular sub base)grade V as per table 400-1 of MORTH, IRC specification, spreading in layers n.exc. 75 mm thick in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 8 to 15 tonne static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and as directed. directed
25M & L for 350mm thick Pavement Quality Concrete (PQC)work in Pavement of minimum field flexural strength 45 Kg/Sqcm (lower control limit) LCL after 28 days of pavement slab using minimum 360 Kg Ordinary Portland Cement Grade 43 per cumwith not exc 31.5mm graded crushed stone aggregate conforming to IS: 383 (grading and other parameters as specified in PS) and mixed with non circular synthetic fibre reinforcement @ 0.25% of weight of ordinary portland cement grade 43 of PQC or as per manufacturers instuction, mixed in batching plant transported to site, laid in panels, spread and compacted using slip form sensor paver , mechanically vibrated and bull nosing / rounding off the edges, curing compund, finishing the surface by belting and brooming without using extra cement etc including necessary form work etc complete all as specified and directed.
26Item No 11.13 Contd ..... Notes : (a) Flexural strength shall be established by beam test and design mix formula should be compatible to IRC-44-2017, IS-456. (b) The non circular fibre synthetic reinforcement mixed with concrete . (c) Curing compound shall be applied at the paving stage after broom finish and surface is dry and rate for use of curing compound shall be included in the unit rate quoted.. (e) Cost of any admixtures required to achieve the desired properties of concrete shall be deemed to be included in the unit rate quoted for PQC nothing extra shall be paid on this account. (f) No price adjustment shall be applicable if excess quantity of Ordinary Portland Cement grade 43 content used in the work as approved in the Design Mix (i.e exceeds 360 Kg). (g) The rate quoted shall be inclusive of use and waste of form work for total thickness. (h) The trial bay will be executed as per above specification and shall be approved by GE. The quoted rate shall be deemed inclusive for this provision and nothing extra shall be paid on this account. (j) Surface shall be finished by traverse brooming of maximum 1.5 mm deep as per ICAO or as per requirement of Air Force Authority. Brooming shall be done through auto texturing machine and rate is included in quoted rate. (k) Ordinary Portland Cement grade 43 only shall be used.
27S& F for speed bump made from heavy duty ABS, UV stablised black and yellow combination, high reflective reflection having Length-70mm, width-23mm available on both sides in red , yellow colour (H=75mm, W=750mm, L=250mm )completeall as specified and as directed.
28M&L for bringing approved earth/moorum/red bajri from outside MOD land and deposited where directed including raising (or lowering) earth, spreading in layer n.exc 30cm thick, watering, ramming/ rolling and finished to required gradient, size and shape etc, n.exc 1.50m high from the base complete all as specified and as directed. Note: (i) Payment shall be made for solid quantity arrived consolidation. (ii) Before execution of this earth shall be tested/ checked for suitabilty to use as IS specification.
29M&L for soil stabalization of 300mm in two layers each 150mm thick sub grade soil by uniform mixing of cement OPC 43 grade/lime/other additive @2% cement by weight of soil (Percentage of cement/additives for estimation purposes only , type of additive and percentage required for blendingshall be in mix design).Item shall incle pulverization of soil, spreading of additive, blending mix by tractor towed rotovator, addition of water/drying of mix to be required moisture content and compaction using suitable vibratory roller to required 95% maximum Dry Density, Provisions of IRC SP 89-2010 shall be refrerred to for this item, complete all as specified and as directed. Note: (i) Payment shall be made for solid quantity arrived consolidation. (ii) Before execution of this earth shall be tested/ checked for suitabilty to use as IS specification.
30Construction of RCC septic tank conventional type designed to carry sewage and sullage water, excavation in ordinary soil, foundation PCC (1:4:8) type D2 (using 40mm graded stone aggregate), RCC M-30 (design mix) using 20mm graded stone aggregate for RCC wall,base slab,baffle wall and roof slab incl beam etc vent shaft,manhole openings with cover connection etccomplete with effective depth of 1.50m and overall depth of 3.0m for 50 users complete all as specified and as shown on drawings.
31M & LSoakage wells for 50 Users,excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick batscomplete all as shown in drawing complete all as specified and as directed.
32Supply , installation and Testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and min EER 5.0.of capacity 2 TR incl shed for outdoor unit and sufficient lenght of copper pipe complete all as specified and as directed.
33Supply , installation and Testing of hi wall split units indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and min EER 5.0.of capacity 1.5TR incl shed for outdoor unit and sufficient lenght of copper pipe complete all as specified and as directed.
34S & FVoltage stabilizer for automatic operation,single phase naturally air cooled indoor typeand designed for input variation between 170V to 250V with output voltage stabilzed at 230 V with accuracy of ± 2.5 %and of capacity 5.0 KVA complete all as specified and directed.
35S & FVoltage stabilizer for automatic operation,single phase naturally air cooled indoor typeand designed for input variation between 170V to 250V with output voltage stabilzed at 230 V with accuracy of ± 2.5 %and of capacity 4.0 KVA complete all as specified and directed.
36S&F Metal plug and socket assembly, Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 6-32 Amp "C" curve fixed flush to wall complete all as specified and directed
37M & L for feather -kites specical coated wall mounting stand suitable for 1.5 to 2 TR split AC outdoor unit consisting of bracket-02 Nos, Angle iron -02 Nos M8 x 50mm , anchor fastener -06 Nos complete all as specified and directed
38Supply and install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP - 31 (9 metres long) including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of red oxide primer, externally from top of coping complete all as specified and as directed. (Note :- Excavation, PCC foundation and coping shall be measured and paid separately.)
39S & F DWC pipe 40mm dia bore,light grade,with all fittings laid in tenches, for mechanical protection of earth strip of earthing etc complete all as specified and as directed.
40S & F DWC pipe 40mm dia bore,light grade,with all fittings laid in tenches, for mechanical protection of earth strip of earthing etc complete all as specified and as directed.
41Supply, Erecting, Testing and Commissioning complete of manufacturer or OEM manufactured, staticsilent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 40KVA, Water Cooled, 415 Volts(AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet , outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Jorhat. (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation( of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,Suitable No of cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering40KVA atoutdoor atmospheric conditions at Jorhat. ,(Taking all derating factor into consideration), , 12/24 Volt(as per manufacturer"s recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer"s instructions and including suitable panel with techometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .
42Item No 11.29 Contd ..... (ii) ALTERNATOR: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 40KVA Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine. (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications. (iv) AMF CONTROL PANEL: Factorymade cubicle type floor mountedLT Panel board, indoor type made out of MS angle not less than 40X40X5 mm, and 2 mm thick MS CRCA sheet , front opening type protection class IP-54 , duly powder coated after seven tank processwith electrolytic grace copper bus bar of 100 Amps capacity for four poles, with all standard switchgear and protection, internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of followings:- (a) MCCB 415 Volts, 63 Amp, rating 4 Pole 18 KArupturing capacity, Microprocessor based release, specially fixed for incoming supply with overload, short circuit and earth fault protection – 2 Nos with suitable rating. (b)Ammeter 0-400 amps, 96 m x 96mm square dial flush type ISI marked with selector switch 3 way and current transformers 100/5 A -01 set (c)Voltmeter 0-500 volts 96 m x 96 mm square dial flush type ISIU marked with rotary selector switch 3 way and current transformer100/5 A-01 set (d) Phase indicating lamps (R-Y-B)- 1 set (e) Frequency meter digital type 45 to 55 HZ – 1 No (f) KWH Meter 3 Phase unbalanced load 100 Ampscapacity incl CT Coil – 1 Set (g) All standard relays circuits and protection required for automatic operation of Gen Set
43Item No 11.29 and 11.30 Contd ..... (v) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002. (vii)External cubicle Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation of Gen Set. (viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. (ix) Factory Test shall be carried out by testing officer nominated by AO. (x) Pre- commissioning test shall be carried out by testing officernominatedbyAccepting Officer.”
44Supply, installation, commissioning and testing of 11 KV, 3 phase, 3 wire, 50 Hz,Indoortype, 630 Amp, 350 MVA, with 01 incomming and 01 outgoing facilityVCB Panels Including Adaptor Panel to connect with existing VCBpanels boards horizontal draw out horizontal isolation floor mounting manually operated panel with 230 Voltmotor mechanism & 24V DC shunt/ close coil and other fittings & accessories.26.3 kA breaking capacity for 3 Sec, totally enclosed with extended copper busbar of 630 Amps for each phase metal clade , indoor extensible type flush front, horizontal isolation, horizontal draw out type with electrical and mechanical interlock and automatic safety shutter gare including pad locking arrangement, isolation plug assemble withVacuuminterrupters with each pole individually encapsulated by epoxy insulations to make it dust proof and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks ( for insertion and removing of VCB) manual and automatic moter charge independent closing / tripping spring, trip free operating mechanism with closing and tripping push bottens and mechanical breaker interconnected with HT sleeve, copper bus bur of 630 Amps including all prospection , indication , operation, monitoring and control and accessories as per specification. Closing and tripping coil of VCB shall be of continuous rating to achieve minimum failure. 11 KV Epoxy Resin Cast Current Transformer CT Ratio : 100-50/5+5A,Core I CL 1.0 with 15 VA burden for metering, Core II CL 5P 10 With 15 VA burden for Protection 11 KV Epoxy Resin Cast Potential Transformer Ratio : 11/ v3 KV/110/ v3V, 3 Phase, Draw out Type, Core I : CL 1.0 with 100 VA burden for metering & ProtectionThe CB shall be provided with Voltmeter 0-12 KV Amphere meter.
45Item No 11.32 Contd ..... (a)HT PT (1 x 3 Phase) draw out type, resin cast, dry type, having rating 11 KV/110 V Class-I, with VA burden 15 having IS-3156 marking -01 No (b)Digital microprocessor based combined over current, earth fault relays and over and under voltage relays. (c)Master tripping relay (d)Phase indicating lamps (e) Digital power factor meter (f) Digital voltmeter with selector switch 0-15V (g)Digital ammeter with selector switch (h)LED lamp indicator lamps for RYB, phase healthy, breaker ON/OFF, trip circuit healthy, spring charged. (j)Breaker Control switch (k)Push buttons for check trip circuit healthy and emergency trip. (l)Switch for closing/tripping of VCB (m) Alarm annunciator for DC supply fail/trip (n)Power pack of suitable capacity with I/P voltage 220 V AC and O/P voltage 110 V DC (o)Copper Bus bar 50mm x 10mm (p)Other standard accessories as specified by OEM.( At MRS II For extension from Existing VCB for Site 3 & site 4 and site 6 as Sqn Hq, MT & Mtrs) Note:-(i) The contractor shall produce general arrangement drawing and technical specifications for approval before placing order.(ii)Factory test shall be carried out by Testing Officer nominated by Accepting Officer.(iii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C"s Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023.
46Supply, installation, commissioning and testing of 11 KV, out door type, 630 Amp, 350 MVA 05 Nos. VCB Panel Board (having 2 Nos. Incoming Panels, 2 Nos. Outgoing Panels & 1 No. Bus Coupler) horizontal draw out horizontal isolation floor mounting manually operated panel with 230V motor mechanism & 24V DC shunt/ close coil and other fittings & accessories.26.3 kA breaking capacity for 3 Sec, totally enclosed with extended copper busbar of 630 Amps for each phase metal clade , indoor extensible type flush front, horizontal isolation, horizontal draw out type with electrical and mechanical interlock and automatic safety shutter gare including pad locking arrangement, isolation plug assemble withVacuuminterrupters with each pole individually encapsulated by epoxy insulations to make it dust proof and self aligning finger type isolation contacts, truck having integral racking with necessary interlocks ( for insertion and removing of VCB) manual and automatic moter charge independent closing / tripping spring, trip free operating mechanism with closing and tripping push bottens and mechanical breaker interconnected with HT sleeve, copper bus bur of 630 Amps including all prospection , indication , operation, monitoring and control and accessories as per specification .Closing and tripping coil of VCB should be of continuous rating to achieve minimum failure. 11 kV Epoxy Resin Cast Current Transformer CT Ratio : 100-50/5+5A,Core I CL 1.0 with 15 VA burden for metering, Core II CL 5P 10 With 15 VA burden for Protection 11 KV Epoxy Resin Cast Potential Transformer Ratio : 11/ v3 KV/110/ v3V, 3 Phase, Draw out Type, Core I : CL 1.0 with 100 VA burden for metering & Protection.
47Item No 11.34 Contd ..... (a)HT PT (1 x 3 Phase) draw out type, resin cast, dry type, having rating 11 KV/110 V Class-I, with VA burden 15 having IS-3156 marking - for incoming VCBs (b)Digital microprocessor based combined over current, earth fault relays and over and under voltage relays. (c)Master tripping relay (d)Phase indicating lamps (e) Digital power factor meter (f) Digital voltmeter with selector switch 0-15V (g)Digital ammeter with selector switch (h)LED lamp indicator lamps for RYB, phase healthy, breaker ON/OFF, trip circuit healthy, spring charged. (j)Breaker Control switch (k)Push buttons for check trip circuit healthy and emergency trip. (l)Switch for closing/tripping of VCB (m) Alarm annunciator for DC supply fail/trip (n)Power pack of suitable capacity with I/P voltage 220 V AC and O/P voltage 110 V DC (o)Copper Bus bar 50mm x 10mm (p)Other standard accessories as specified by OEM.
48Item No 11.34 & 11.35 Contd ..... Note:-(i) The contractor shallsubmit QAP (Quality Assurance Programme) within 15 days after placement of order for RMU for testing of equipments at factory.RMU shall be despatch only after inspection at manufacturer premises shall be done by OEM Auth and MES auth at manufacture premises. (ii)Contractor shall furnish original Purchase Voucher of the RMU manufacturer.(iii) Contractor shall make all the testing arrangementand arrange all the testing tools @ 2 times (at the timde of commissioning and against at the time of SEI inspection for pre-commissioning test and testing at site before operation of RMU) without any extra cost.All the installations and testing tyo be done in presence of /by OEM representative. (iv)Suitable RCC platform for outdoor installation with height as required at site to mount the RMU as per manufacturer"s recommendations. (v) Contractor shall producegeneral arrangement drawing and technical specifications for approval before placing order.(vi) Factory test shall be carried out by Testing Officer nominated by Accepting Officer.(vii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C"s Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023.
49Supply, installation, testing and commissioning of 11KV, 630A VCB with 500 KVA Resin cast Transformer and LT Side - CSS Outdoor Panel(LT panelincoming - 1 NoOutgoing - 4 Nos ( One for VOLTAGE STABLIZER , Second for DG AMF Panel &third is for APFC Panel and fourth is spare). (For Site 6 Location) HT Section 11KV, 630A, Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 24V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Button, mechanical Operating Counter with metering Cubical, Auxiliary Relay, 8 Window Announciator, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit.-01 Nos (a)HT PT (1 x 3 Phase) draw out type, resin cast, dry type, having rating 11 KV/110 V Class-I, with VA burden 15 having IS-3156 marking - for incoming VCBs (b)Digital microprocessor based combined over current, earth fault relays and over and under voltage relays. (c)Master tripping relay (d)Phase indicating lamps (e) Digital power factor meter (f) Digital voltmeter with selector switch 0-15V (g)Digital ammeter with selector switch (h)LED lamp indicator lamps for RYB, phase healthy, breaker ON/OFF, trip circuit healthy, spring charged.
50Item No 11.37 Contd ..... (j)Breaker Control switch (k)Push buttons for check trip circuit healthy and emergency trip. (l)Switch for closing/tripping of VCB (m) Alarm annunciator for DC supply fail/trip (n)Power pack of suitable capacity with I/P voltage 220 V AC and O/P voltage 110 V DC (o)Other standard accessories as specified by OEM. Current Transformer –Cast resin Ratio: 50-25/5-5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA-01 Nos Indication Lamps :VCB off / on / auto trip/ Trip circuit healthy/spring charge indication- 1Set Metering: Digital Ammeter & Digital Volt Meter- 1Set Transformer Section 500 KVA, 11/0.433 KV, “BIS Marked & BEE Star Labelled” Copper Wound Resin cast Step Down Off Load Tap Changer (OLTC) Transformer (7 position having tapping range +7.5% in steps of 2.5% each) with all standard fittings & accessories including OTI, WTI & Marshalling Box (as per IS-1180:2014 EEL-2 with amendment no.- 1,2,3 & 4) Formerly EEL-3 (till 30.3.2022) with and including Auxilary relays, winding temperature indicator, master trip relay and all standard relays accessories etc for making the system complete as per prevailing IS/BEE.
51Item No 11.37 & 11.38 Contd ..... LT Section Incoming – 800 Amp 4P Air Circuit Breaker microprocessor based with O/L S/C & E/F Protection – 01 No. Outgoing – 100 Amp 4 Pole MCCB with thermal magnetic based release with O/L &S/C protection – 02 No. 200 Amp 4 Pole MCCB with thermal magnetic based release with O/L & S/C protection – 01 No. 800 Amp 4 Pole MCCB with thermal magnetic based release with O/L & S/C protection – 01 No. 800A/5A LTCT Cl:1.0 -03 Nos Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LTCubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control--02 Set MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel.- 02 Set Provision for receiving Incoming cables through Bottom entry and out going through Bus bar to Trf panel, Excluding Termination Kit & Glands. Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry Excluding Termination Kit & Glands-02 Set Bus Bar – Aluminium , Earth Bus –Aluminium-02 Set Paint shade: Siemens Grey ( RAL 7032) Note:- Rate are inclusive of foundation as per OEM recommendation , testing and commissioning of the above item
52Item No 11.37, 11.38& 11.39 Contd ..... Note:-(i) The contractor shallsubmit QAP (Quality Assurance Programme) within 15 days after placement of order for RMU for testing of equipments at factory.RMU shall be despatch only after inspection at manufacturer premises shall be done by OEM Auth and MES auth at manufacture premises. (ii)Contractor shall furnish original Purchase Voucher of the Transformer manufacturer. (iii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C"s Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023. (iv)Cost of hiring T & P and all testing equipments at site required for testing of plant(v)Suitable RCC platform for outdoor installation with height as required at site to mount the Transformeras per manufacturer"s recommendations.
53Supply, installation, testing and commissioning of 11KV, 630A VCB with 1000 KVA Resin Cast Transformer and LT Side - CSS Outdoor Panel (LT panelincoming - 1 No, Outgoing - 3 Nos ( one for VOLTAGE STABLIZER , Second for DG AMF Panel &third is for APFC Panel).(For Site 4 Location) HT Section 11kV, 630A, Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 24V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Button, mechanical Operating Counter with metering Cubical, Auxiliary Relay, 8 Window Announciator, Battery Power Pack with 7AH Battery & in built charger for 24V Circuit.-01 Nos (a)HT PT (1 x 3 Phase) draw out type, resin cast, dry type, having rating 11 KV/110 V Class-I, with VA burden 15 having IS-3156 marking - for incoming VCBs (b)Digital microprocessor based combined over current, earth fault relays and over and under voltage relays. (c)Master tripping relay (d)Phase indicating lamps (e) Digital power factor meter (f) Digital voltmeter with selector switch 0-15V (g)Digital ammeter with selector switch (h)LED lamp indicator lamps for RYB, phase healthy, breaker ON/OFF, trip circuit healthy, spring charged.
54Item No 11.41Contd ..... (j)Breaker Control switch (k)Push buttons for check trip circuit healthy and emergency trip. (l)Switch for closing/tripping of VCB (m) Alarm annunciator for DC supply fail/trip (n)Power pack of suitable capacity with I/P voltage 220 V AC and O/P voltage 110 V DC (o)Other standard accessories as specified by OEM. Current Transformer –Cast resin Ratio: 50-25/5-5A, Core1:Cl.0.5, 15VA, Core2:Cl.5P10, 15VA-01 Nos Indication Lamps :VCB off / on / auto trip/ Trip circuit healthy/spring charge indication- 1Set Metering: Digital Ammeter & Digital Volt Meter- 1Set Transformer Section 1000 KVA, 11/0.433 KV, “BIS Marked & BEE Star Labelled” Copper Wound Resin cast Step Down Off Load Tap Changer (OLTC) Transformer (7 position having tapping range +7.5% in steps of 2.5% each) with all standard fittings & accessories including OTI, WTI & Marshalling Box (as per IS-1180:2014 EEL-2 with amendment no.- 1,2,3 & 4) Formerly EEL-3 (till 30.3.2022)with and including Auxilary relays, winding temperature indicator, master trip relay and all standard relays accessories etc for making the system complete as per prevailing IS/BEE.
55Item No 11.41 & 11.42 Contd ..... LT Section Incoming – 1600 Amp 4P Air Circuit Breaker microprocessor based with O/L S/C & E/F Protection – 01 No. Outgoing – 100 Amp 4 Pole MCCB with thermal magnetic based release with O/L &S/C protection – 01 No. 200 Amp 4 Pole MCCB with thermal magnetic based release with O/L & S/C protection – 02 No. 1250 Amp 4 Pole ACB with thermal magnetic based release with O/L & S/C protection – 01 No. 1600A/5A LTCT Cl:1.0 -03 Nos Space Heater with ON/OFF Switch and Thermostat, Single phase switch with socket, LTCubical illumination Lamp with Door Limit switch and MCB’s for AC / DC Control--02 Set MS Steel Sheet enclosure suitable for Outdoor Installation with MS base channel.- 02 Set Provision for receiving Incoming cables through Bottom entry and out going through Bus bar to Trf panel, Excluding Termination Kit & Glands. Provision for receiving Incoming through bus duct by bus bar and Outgoing through cable box bottom entry Excluding Termination Kit & Glands-02 Set Bus Bar – Aluminium , Earth Bus –Aluminium-02 Set Paint shade: Siemens Grey ( RAL 7032) Note:- Rate are inclusive of foundation as per OEM recommendation , testing and commissioning of the above item
56Item No 11.41. 11.42 & 11.43Contd ..... Note:-(i) The contractor shallsubmit QAP (Quality Assurance Programme) within 15 days after placement of order for RMU for testing of equipments at factory.RMU shall be despatch only after inspection at manufacturer premises shall be done by OEM Auth and MES auth at manufacture premises. (ii)Contractor shall furnish original Purchase Voucher of the Transformer manufacturer. (iii) Pre-commissioning test shall be carried out by SEI/EI/ESO as per policy issued by E-In-C"s Branch letter No 36323/Gen/CEI/E4(U) dated 30 May 2023. (iv)Cost of hiring T & P and all testing equipments at site required for testing of plant(v)Suitable RCC platform for outdoor installation with height as required at site to mount the Transformeras per manufacturer"s recommendations.
57M&L for loose filling of hard core packed aggregateexceeding 63 mm but not exc 100mm size up to the height of 15 cm thick, around the two pole structure and existing transformer/2 pole/4 pole structure after leveling the ground for flooring with plain cement concrete 1:4:8Type -D2 (40mm graded stone aggregate)up to the height of 10 cmcomplete all as specified and as directed.Note : ( Before filling up of aggregate, the suface shall be prepared for preventing grass growth around the equipment/structure )
58Supply of servo controlled voltage stabilizer (BearingBIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 900 KVA Naturally oil cooled, outdoor, unbalance type load, copper (99.9%) wound, with microprocessor based control card, digital type relay, free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, complete all as specified , as directed andhaving following specifications :(FOR SITE NO 4) (a) Input voltage 300 V to 480V ( or as customer requirements) (b) Output voltage stabilized at any designed/desired voltage 415V +(-)1% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time shall not exceed 10 milli seconds (f) Sensitivity (+) 1%. Rate of correction6 to 8 volts/second.Efficiency more than 98% (g) Type of load : Three phase, unbalanced type (h) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz. (i) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil, di-electric strength of oil should not less than 60 KV and temperature gauge. (j) Charging motor of suitable capacity. (k) Termination : Input & output termination as per IS : 3347. (l) Operation : Auto and Manual. (m) Metering : Digital AC voltmeter, Ampere meter with CT and selector switch for input & Output voltage. (n) Digital meter foroil temperature indication. (o) Insulation resistance more than 10 mega Ohms. at 500 volt DC. (p) Factory Test shall be carried out by testing officer nominated by AO. (q) Pre- commissioning test shall be carried out SEI/EI.”
59Item No 11.46Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) includevoltage test.
60Supply of servo controlled voltage stabilizer (BearingBIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 25 KVA Naturally oil cooled, outdoor, unbalance type load, copper (99.9%) wound, with microprocessor based control card, digital type relay, free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, complete all as specified , as directed andhaving following specifications :(FOR SITE NO 4) (a) Input voltage 300 V to 480V ( or as customer requirements) (b) Output voltage stabilized at any designed/desired voltage 415V +(-)1% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time shall not exceed 10 milli seconds (f) Sensitivity (+) 1%. Rate of correction6 to 8 volts/second.Efficiency more than 98% (g) Type of load : Three phase, unbalanced type (h) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz. (i) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil, di-electric strength of oil should not less than 60 KV and temperature gauge. (j) Charging motor of suitable capacity. (k) Termination : Input & output termination as per IS : 3347. (l) Operation : Auto and Manual. (m) Metering : Digital AC voltmeter, Ampere meter with CT and selector switch for input & Output voltage. (n) Digital meter foroil temperature indication. (o) Insulation resistance more than 10 mega Ohms. at 500 volt DC. (p) Factory Test shall be carried out by testing officer nominated by AO. (q) Pre- commissioning test shall be carried out SEI/EI.”
61Item No 11.48Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) includevoltage test.
62Supply of servo controlled voltage stabilizer (BearingBIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 450 KVA Naturally oil cooled, outdoor, unbalance type load, copper (99.9%) wound, with microprocessor based control card, digital type relay, free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, complete all as specified , as directed andhaving following specifications :(FOR SITE NO 6) (a) Input voltage 300 V to 480V ( or as customer requirements) (b) Output voltage stabilized at any designed/desired voltage 415V +(-)1% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time shall not exceed 10 milli seconds (f) Sensitivity (+) 1%. Rate of correction6 to 8 volts/second.Efficiency more than 98% (g) Type of load : Three phase, unbalanced type (h) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz. (i) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil, di-electric strength of oil should not less than 60 KV and temperature gauge. (j) Charging motor of suitable capacity. (k) Termination : Input & output termination as per IS : 3347. (l) Operation : Auto and Manual. (m) Metering : Digital AC voltmeter, Ampere meter with CT and selector switch for input & Output voltage. (n) Digital meter foroil temperature indication. (o) Insulation resistance more than 10 mega Ohms. at 500 volt DC. (p) Factory Test shall be carried out by testing officer nominated by AO. (q) Pre- commissioning test shall be carried out SEI/EI.”
63Item No 11.50Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) includevoltage test.
64Supply of servo controlled voltage stabilizer (BearingBIS 9815 : Part I : 1994), Three phase AC system, 50 Hz of capacity 30 KVA Naturally oil cooled, outdoor, unbalance type load, copper (99.9%) wound, with microprocessor based control card, digital type relay, free smooth and silent operation with 1st filling of new insulating oil as per BIS standard packed in sealed containers, including necessary incoming and outgoing connection, complete all as specified , as directed andhaving following specifications :(FOR SITE NO 6) (a) Input voltage 300 V to 480V ( or as customer requirements) (b) Output voltage stabilized at any designed/desired voltage 415V +(-)1% (c) Rated frequency 50Hz (d) No distortion in wave form (e) Response time shall not exceed 10 milli seconds (f) Sensitivity (+) 1%. Rate of correction6 to 8 volts/second.Efficiency more than 98% (g) Type of load : Three phase, unbalanced type (h) Multifunction meter 3 phase 415 volts showing Voltage, Amps & Hz. (i) Oil quantity as recommended by manufacturer complete with oil level indicator showing minimum and maximum level of oil, di-electric strength of oil should not less than 60 KV and temperature gauge. (j) Charging motor of suitable capacity. (k) Termination : Input & output termination as per IS : 3347. (l) Operation : Auto and Manual. (m) Metering : Digital AC voltmeter, Ampere meter with CT and selector switch for input & Output voltage. (n) Digital meter foroil temperature indication. (o) Insulation resistance more than 10 mega Ohms. at 500 volt DC. (p) Factory Test shall be carried out by testing officer nominated by AO. (q) Pre- commissioning test shall be carried out SEI/EI.”
65Item No 11.52Contd ..... PROTECTION:- (i) Overload Cut-Off and short circuit Protection (ii) High/Low voltage cut off (iii) Bypass arrangement in case of emergency. (iv) Single phase Prevention. (v) Spike and surge protection. (vi) Earth Fault protection. (vii) Test Reports as per clause 11.1 for any rating as per clause 5.1 from BIS: 9815 (Part –I) re-affirmed 2004. (aa) Physical eximation (ab) Insulation resistance. (ac) High Voltage Test (ad) leakage current test. (ae) Provision of earting. (af) Output voltage. (ag) No load current. (ah) measurmet of no load losess. (aj) includevoltage test.
66Supply , Installation, Commissioning and Testing of 500 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC Air -Cooled, Double Wound, Dry Type Varnish impregnated Isolation Transformer, with enclosure, suitable for out dooruse in a maximum ambient temperature of 45 Deg C, bearing IS 2026 & IS 11171 Primary : 380 V, 3-Phase, 50 Hz, AC, Secondary : 380 V AC 3 Phase, 50 Hz Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘B’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds.Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a)Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b)Surge protection against load surges, insulation class "A" digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note:(i)Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer(ii)Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer(iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 6)
67Supply , Installation, Commissioning and Testing of 1000 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC Air -Cooled, Double Wound, Dry Type Varnish impregnated Isolation Transformer, with enclosure, suitable for out dooruse in a maximum ambient temperature of 45 Deg C, bearing IS 2026 & IS 11171 Primary : 380 V, 3-Phase, 50 Hz, AC, Secondary : 380 V AC 3 Phase, 50 Hz Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘B’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds.Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a)Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b)Surge protection against load surges, insulation class "A" digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note:(i)Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer(ii)Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer(iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 4)
68Supply , Installation, Commissioning and Testing of 25 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC Air -Cooled, Double Wound, Dry Type Varnish impregnated Isolation Transformer, with enclosure, suitable for out dooruse in a maximum ambient temperature of 45 Deg C, bearing IS 2026 & IS 11171 Primary : 380 V, 3-Phase, 50 Hz, AC, Secondary : 380 V AC 3 Phase, 50 Hz Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘B’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds.Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a)Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b)Surge protection against load surges, insulation class "A" digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note:(i)Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer(ii)Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer(iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 4)
69Supply , Installation, Commissioning and Testing of 50 KVA Isolation transformer, Three Phase, Oil cooled, copper wound including first filling of oil of requiste di-electric strength as per IS-335, 50 Hz, AC Air -Cooled, Double Wound, Dry Type Varnish impregnated Isolation Transformer, with enclosure, suitable for out dooruse in a maximum ambient temperature of 45 Deg C, bearing IS 2026 & IS 11171 Primary : 380 V, 3-Phase, 50 Hz, AC, Secondary : 380 V AC 3 Phase, 50 Hz Connection : Delta – Star, Vector Group : Dyn 11, Insulation : Class ‘B’ complete all as specified and as directed yo collect unbalance type, frequency 50 Hz +/-3%, di-electric strength 2.5 KV for 60 seconds.Insulation shall be more than 1000 Mega Ohms, impedence Voltage:3-4% and comprises with the following :- (a)Standard fittings and fixtures with provision for over load short circuit, light low cut off, single phase seqence change (b)Surge protection against load surges, insulation class "A" digital instrumentations (digital ampere meter and voltmeter), thermometer, bottom oil cum drain valve, rating diagram and terminal marking plate, earthing terminal -02 Nos, lifting eye/plugs, under carriage with 04 x Nos of bi-diectional rollers, separate neutral brush. Note:(i)Pre-despatch inspection at OEM/factory premises shll be carried out by Rep of Accepting Officer(ii)Prior to manufacture, the contractor shall get the GA drg approved from Accepting Officer(iii) After installation of transformer at site, the pre-commissioning test shall be carried out by SEI/ESO/EI. (FOR SITE NO 4)
70Supply and layingSub-Class " B" bricks, well burnt, laid breadth-wise along the length of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
71Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm, Indoor/Outdoor type complete all as specified and as directed.
72Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm, Indoor/Outdoor type complete all as specified and as directed.
73Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240 sqmm, Indoor/Outdoor type complete all as specified and as directed.
74Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 400 sqmm, Indoor/Outdoor type complete all as specified and as directed.
75Supply and fixing cable jointing kit for 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 sqmm complete all as specified and as directed.
76Supply and fixing cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 240 Sqmm, Outdoor type complete all as specified and as directed.
77Supply & Installation of Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED( 80-100)microns with pure Zinc (99.9%) & ALLOY COATING (200-250) microns. Earthing System confirming IS 3034:1987. The outer and inner pipe shall be76.3 mm & 41.9 mm 3 mtrs Length, Zinc coated with additional special Alloy coating 300mm on the top side for additional corrosion protection of the Terminal. The annular space between the pipes shall be filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed in the pipes shall not disintegrate or collapse when outer pipe corrodes. The inner pipe shall be extended with terminals for connectivity. The job includes digging the pits and refilling the same by Conductolite Back Fill compound (Ground Enhancer), the BFC shall be eco friendly.It shall not contain environmentally hazardous material/metal having RoHS Certification from NABL accredited lab. Good earth shall be arranged to fill the excavated pits by mixing the same with BFC 2 bags (each bag contains 25 kgs of BFC) including FRP(fiber reinforced plastic) cover having high mechanical strength, chemical resistance able to bear 2 TON of loads with detachable easy locking lid complete all as specified & directed. Model no- ASEEL_39-ZC & AC (76.3mm dia)
78Boring of holes under road, pavement, hard standingfor protection of pipe upto 100mm bore, not exceeding 10.00 mtr in a single lengthwithout damaging the existing road , getting out and disposal of excavated soil to a distance not exc 50 mtr from the site of work complete all as specified and directed.
79M & L for cutting road, pavement, hard standingetc and making good distrubed surface, finishingwith PCC (1:3:6)type C-2 using 40mm graded stone aggregate for fixing the pipe,getting out and disposal of excavated soil to a distance not exc 50 mtr from the site of work complete all as specified and directed.
80M & L for Relaying and Rerouting after pulling out the cable from trenches/road crossing/from the circular pipe/duct etc without damaging the cable and cleaning/straightening of cable if required at site of serviceable HT/LT UG cable of any size and any capacity completeall as specified and directed. (Note:- Excavation, sand, bricks and connected items shall be measured and paid separately).
81S&F Cable Junction Box 200X160X98mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat iron clamps of size 25x3mm, nuts, bolts, washers etc. including applying Two Coats of Synthetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer complete all as specified and as directed.
82Supply, layingand testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 33000 volts grade, of size 3 core 240 sq mm, complete all as specified and as directed.
83M&L for PVC sheathed copper cable of1.5 sqmm, 3 core for street light / Dwarf light connection on pole from junction box to light fitting complete all as specified and as directed.
84S&F steel tubular pole 2 Mtr long including necessary reducer,bracket ,clamp,nut bolts and screws and welding of base plate of suitable size inpole including painting of pole with two coats ofaluminium paint over a coat of primer, bracket is suitable for fitting 35 watt led street light complete all as specifed and as directed.
85Supply, fixing, grouting and painting HT/LT cable route indicator made up of Factory made Precast RCC slab of size Length 15 inch ( 38.1 cm), Width 6 inch (15.24 cm)and height 4 feet (121.92 cm)duly engrave as PH-I BK-II with red color andengrave as IACCS with YELLOW color and alsoSize of Cable and grouting on the route of HT/LT cable complete all as specified and as directed. Note :- (i)Unit rate of item includes excavation, PCC foundation for erection of route indicator (ii) Slab of route indicate shall be provided with min 4 Nos x8 mm diameters TMT bars along length of slab with 7 Nos cross bar 6 mm dia in reinforcement with shuttering (iii) Route indicator RCC slab shall be paintedwith two coats ofred/blue colour synthetic enamel paint over a one coatof white primer base complete all as specified and directed.
86Dismantling of street light poles/dwarf light pole of any type and any length from existing position andshifted to MES store yard and making good disturbed surfaces complete all as specified and as directed.
87Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR SITE NO 6)
88Item No 11.75 Contd...... BUS-BAR CHAMBER : Copper bus bar 1200 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)ACB 800 amps, 415 volt, 50 kA breaking capacity, Fixed type,4 pole duly connected to bus bar as incoming - 01Nos. OUTGOING/INDICATING DEVICES : (i)MCCB 320 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic ,duly connected to bus bar as outgoing - 02 Nos.( one spare) (ii) MCCB 250 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic ,duly connected to bus bar as outgoing- 02 Nos. (iii)MCCB 63 amps, 415 volt, 25 kA breaking capacity 4 pole , Thermal magnetic , duly connected to bus bar as outgoing - 01 No. (iv) Digital Multifunction meter, Model C, class 1, with relay - 01 No, with Suitable CT and wiring. (v) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
89Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR SITE NO 4)
90Item No 11.77 Contd...... BUS-BAR CHAMBER : Copper bus bar 1900 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)ACB 1250 amps, 415 volt, 50 kA breaking capacity, Fixed type,4 pole duly connected to bus bar as incoming - 01 Nos. OUTGOING/INDICATING DEVICES : (i)MCCB 320 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic ,duly connected to bus bar as outgoing - 02 Nos.( one spare) (ii) MCCB 250 amps, 415 volt, 36 kA breaking capacity 4 pole, Thermal magnetic ,duly connected to bus bar as outgoing- 02 Nos. (iii)Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
91Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FORFU-1, TECH SET UP , SCP & LRSR, WATCH TOWER)
92Item No 11.79 Contd...... BUS-BAR CHAMBER : Copper bus bar 150 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB 100amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 80amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar asoutgoing- 02Nos ( one spare) (ii) TPN MCB 25 Amp- 03 Nos (One Spare) (iii)Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
93Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR30 KW load at site No 6)
94Item No 11.81 Contd...... BUS-BAR CHAMBER : Copper bus bar 100 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB 63amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing- 01Nos (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
95Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR120KW load at site No 4 & 6)
96Item No 11.83 Contd...... BUS-BAR CHAMBER : Copper bus bar400 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB250 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 250 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01Nos (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
97Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FOR150KW load at site No 4 & 6)
98Item No 11.85 Contd...... BUS-BAR CHAMBER : Copper bus bar500 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB320 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 320 Amps, 415 volt, 36 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01Nos (ii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iii) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
99Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FORSite No 4)
100Item No 11.87 Contd...... BUS-BAR CHAMBER : Copper bus bar150 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB100 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01Nos (ii) TPN MCB 32 Amp -01 No (for timer panel) (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
101Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FORSite No 4 & 6)
102Item No 11.89 Contd...... BUS-BAR CHAMBER : Copper bus bar150 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB100 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 02Nos (One spare) (ii) MCCB 40 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01Nos (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
103Supply,install, testingand commissioningout door type LT Control Panel of suitable size, CPRItype tested,factory fabricated totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof,degree of protection not less than IP 55, conforming to IS : 60947 : 2004 double leaf shutter in front and single leaf shutter in rear side. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation and copper busbar wrapped with PVC tape/sleeves and maintained the colour code and copper strip busbar as per MCCB/ACB amps rated to MCCB input and MCCB output of suitable length for connection of cable from main busbar. Panel shall be fabricated with 3.15 mm thick CRCA sheet and pass through 11 tank process (certificate will be provided by the manufacturer) duly pre-treated & powder coated, framing withMS angle iron 40 x 40 x 6 mm andMC 100 channel base duly pre-treated and powder coated paint over exposed external & internal surfaceshaving proper locking arrangement in both front and rear door with 4 side slanting roof duly projected,and suitable for 415 volts, 50 Hz, 3 phase 4 wire system including complete internal wiring with 2.5 sqmm copper wire and connections. The bottom of the outer shell shall be contained with detachable plate having provision for entry of armored cable of adequate size with glands. Inner shell shall be compartmentalized for each control gear. Provision of two Nos threaded earthing stud at bottom and lifting lugs of suitable size at top to lift the panel safely shall be madeand comprising with and includingfollowing accessories and mounted on PCC (1:3:6) type C-2 foundation of suitable size and depth (min 30 cm below ground level & min 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed with and including the following accessories.:- (FORSite No 4 & 6)
104Item No 11.91 Contd...... BUS-BAR CHAMBER : Copper bus bar200 Amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nuts, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow, blue) for three phases and black for neutral. PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING (i)MCCB100 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as incoming - 01 Nos.. OUTGOING/INDICATING DEVICES : (i) MCCB 63 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 0Nos (For voltage stablizer) (ii) MCCB 40 Amps, 415 volt, 25 kA breaking capacity 4 pole duty connected to bus bar as outgoing - 01Nos (For OTM of FU-1) (iii) Digital Multifunction meter, Model C, class 1, with relay - 01 No., with Suitable CT and wiring. (iv) Indicator lamp with LED (red, yellow & blue), Set of Three - 01 Set.
105NOTE FOR Item No 11.75to 11.92 (i) Design / drawing of the Panel Board showing the dimensions shall be obtained from Manufacturer / Supplier & shall be got approved from the Dept before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
106Supply , Fixing, Comissioningand Testing and ofautomatic street light switch of capacity 5 to 8 KW in three phase,using Nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contractor, MCB and support terminals enclosed in pole/ wall mounted enclouser made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54, including mounting arrangementwith suitable size of FI clamps 02 Nos of 25 mmx3mm thickness, Bolts and nuts as required at site and connected to street light over head/under ground feeder with complete acessories complete all as specified and directed. The automatic switching unit shall comprising of thefollowing: (i) Contractor rating (AC3) Three phase16-20 Amp (4 Pole) (ii) MCB 20 Amps(SP-3 Nos),10 KA ,240 volts-3 Nos . (iii)NATURESWITCH-01 Note- Price shall be inclusive of Sensor, Contactor, Incoming-Outgoing MCBs, Enclosure etc complete
107Supply, installation, testingand commissioning of Outdoor type Automatic intelligent power factor corrector (APFC) capacitor bankpanel floor mounted ,weather proof made out of 3.15 mm thick CRCA sheet , out door type and structure duly fixed on structural channel, fixed on ground withPCC( 1:2:4) Type B-1(using 20mm graded stone aggregate)and finished the surface,the cubicle panel shall have enameled danger notice plate, duly painted with two coats of powder coated paint internally and externally on the surface complete all as specified and directed. The panel box shall be cubicle shaped with special type of hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements including necessary control circuit connections and necessary cable connections by lugs and glands , including provisionfor accommodating capacitor and the following electrical items:- Automatic power factor correction (APFC) Panel for 3 phase, 415 V & 50 Hz system of capacity 400 KVAR with 22 steps (2x50 + 2x30 + 4x25 + 4x15 + 6x10 + 4x5)with MDXL capacitor and controller completeall as specified and directed.
108Item No 11.95 Contd...... The APFC Panel comprising of following specifications : (a)MDXL type power capacitor with harmonic filter and 10% nonlinear load for 3 phase 440 V 50 HZ system of banking pattern 400 KVAR with 8 steps (2x100 + 2x50 + 4x25) (b) Automatic PF Controller 5 Step LCD display 110-415 V AC -01 No (c) Main incoming MCCB 630 A FP 36 kA with Ics=100%Icu with front operate rotary handle. (d)Contactors (Capacitor duty type ) (e)Delay Timer (f) Individual MCB (SP/DP/TP) (g) Selector switch for automatic / manual operation - 01 No. (h) CT (Cast Resin type)- 03 Nos (j) LED type phase indicating lamps (RYB) (k)Push button & elements (reqd Qty) (l) Emergency push button switch-01 No (m) 2P 2 Way selector switch - 01 No (n)Axial type panelmounted Fan -01 No (o) Multi function meter - 01 No
109Supply, installation, testingand commissioning of Outdoor type Automatic intelligent power factor corrector (APFC) capacitor bankpanel floor mounted ,weather proof made out of 3.15 mm thick CRCA sheet , out door type and structure duly fixed on structural channel, fixed on ground withPCC( 1:2:4) Type B-1(using 20mm graded stone aggregate)and finished the surface,the cubicle panel shall have enameled danger notice plate, duly painted with two coats of powder coated paint internally and externally on the surface complete all as specified and directed. The panel box shall be cubicle shaped with special type of hinges and totally enclosed dust proof and vermin proof front and back opening with locking arrangements including necessary control circuit connections and necessary cable connections by lugs and glands , including provisionfor accommodating capacitor and the following electrical items:- Automatic power factor correction (APFC) Panel for 3 phase, 415 V & 50 Hz system of capacity 200 KVAR with 8 steps (2x50 + 2x30 + 2x15 +2x5)with MDXL capacitor and controller completeall as specified and directed.
110Item No 11.97 Contd...... The APFC Panel comprising of following specifications : (a)MDXL type power capacitor with harmonic filter and 10% nonlinear load for 3 phase 440 V 50 HZ system of banking pattern 200 KVAR with 6 steps (2x 12.5 + 1x 25 + 3x 50) (b) Automatic PF Controller 5 Step LCD display 110-415 V AC -01 No (c) Main incoming MCCB 300 A FP 36 kA with Ics=100%Icu with front operate rotary handle. (d)Contactors (Capacitor duty type ) (e)Delay Timer (f) Individual MCB (SP/DP/TP) (g) Selector switch for automatic / manual operation - 01 No. (h) CT (Cast Resin type)- 03 Nos (j) LED type phase indicating lamps (RYB) (k)Push button & elements (reqd Qty) (l) Emergency push button switch-01 No (m) 2P 2 Way selector switch - 01 No (n)Axial type panelmounted Fan -01 No (o) Multi function meter - 01 No
111M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth lead wire 4.0 mm dia bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plateNo-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 32 mm (light grade), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast RCC (1:2:4) type B1, cover slab of size 54 cm x 54 cm x 5 cm and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b)PCC pit (with pit cover) shall be provided at least 500mm away and not on the earth pit itself and cost of additional height of watering pipe, bends, elbow etc shall deemed to be included in the unit rate. (c)Excavation/earthwork is deemed to be included in the quoted rate.]
112M & L Earthing complete with Galvanized steel earth plate electrode 600 mm x 600mm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32 x 6 mmby means of bolts, nuts,check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b)Excavation/earthwork is deemed to be included in the quoted rate.]
113M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper strip of size 20 x 3mmby means of bolts, nuts,check nuts and washers protected by 32mm bore medium grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. [Note : (a)The unit rate includes for protection pipe and earth lead upto 7.5 m. Any variation in length of earth lead and protection pipe beyond 7.5 m shall be measured and paid seperately. (b) excavation/earthwork is deemed to be included in the quoted rate.]
114Demolition of concrete (asphatic concrete/ PCC) of any description and in any positionnot otherwise speciifically provided for and removing the demolished materials to a distance exc. 500mtr but n exc. 1.5 km and depositing where directedcomplete all as specified and as directed.