Tender For Special Repair/Replacement To Bldg No T/Op 30 31 And 32 Including Change Of Cgi Sheet Flooring Internal Electrification Painting With Connected Items At Mahar And Provision Of 02 X 1000 Ltrs Solar Water Heater In Bldg No Tb 230 At Adhoc Tr, Siliguri-West Bengal

Military Engineer Services-MES has published Tender For Special Repair/Replacement To Bldg No T/Op 30 31 And 32 Including Change Of Cgi Sheet Flooring Internal Electrification Painting With Connected Items At Mahar And Provision Of 02 X 1000 Ltrs Solar Water Heater In Bldg No Tb 230 At Adhoc Tr. Submission Date for this Tender is 17-05-2024. Electrification Work Tenders in Siliguri West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

43287687
Tender For Special Repair/Replacement To Bldg No T/Op 30 31 And 32 Including Change Of Cgi Sheet Flooring Internal Electrification Painting With Connected Items At Mahar And Provision Of 02 X 1000 Ltrs Solar Water Heater In Bldg No Tb 230 At Adhoc Tr
Open Tender
Indian
West Bengal
Siliguri
17-05-2024

Tender Details

Special Repair / Replacement To Bldg No T / Op 30 31 And 32 Including Change Of Cgi Sheet Flooring Internal Electrification Painting With Connected Items At Mahar And Provision Of 02 X 1000 Ltrs Solar Water Heater In Bldg No Tb 230 At Adhoc Transit Camp

Key Value

Document Fees
INR 500 /-
EMD
INR 73800.0 /-
Tender Value
INR 36.90 Lakhs /-

BOQ Items

Nature of Work: SPECIAL REPAIR/REPLACEMENT TO BLDG NO T/OP 30,31 & 32 INCLUDING CHANGE OF CGI SHEET,FLOORING, INTERNAL ELECTRIFICATION, PAINTING WITH CONNECTED ITEMS AT MAHAR AND PROVISION OF 02 X 1000 LTRS SOLAR WATER HEATER IN BLDG NO TB 230 AT ADHOC TRANSIT CAMP & BLDG NO 4/71/16-17/0089C (SAPPER) OFMADRAS AT BAISAKHI OF AGE (P) AND AGE E/M UNDER GE 859 EWS.
Sl. No. Item Description
1Dismantling of plain or corrugated steel sheeting any gauge, thickness as in roof covering with complete all as specified and directed by Engr-in-Charge.
2Supply and fix, 0.63 mm thick corrugated galvanised mild steel sheeting (minimum 275gm/sqm galvanising) with two corrugations side lap, fixed with L type or J type or cranked hooks , bolts and washer in roof with complete all as specified and directed by Engr-in-Charge.
3Supply and fix plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashing of 0.80mm thickness (minimum 275gm/sqm galvanising)complete all as specified and directed.
4Dismantling wrought iron or mild steel work of any description not otherwise provided for with complete all as specified and directed.
5S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc with complete all as specified and directed.
6Material and labour for preparing new galvanised surfaces to receive painting by coating with mordent solution including washing and cleaning and applying two coats of anticorrosive roof paint over a coat of red oxide primer over 10 cm width or girth on steel surface .
7Material and labour for preparation of oldsteel surfaces of any description, over 10 cm width or girth not other wise described and applying one coat of roof & wall paintprimer complete all as specified and directed.
8Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.50 Sqm but n exc 4.0 Sqm each including iron mongeries complete all as specified and directed.
9Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete, all as specified and directed
10S& F for 2nd class HW 30mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats with complete all as specified and directed.
11Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.50 Sqm each including iron mongeries complete all as specified and directed.
12S&F2nd class HW 30mm thick Glazed and skeleton shutters,divided into squared, with plain, chamfered or roun0ded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
13Supply & fix Aluminium anodisedbarrel tower bolt 150 mm long of extruded section etc complete all as specified and directed.
14Supply and fix MS butt hinges medium weight, cold rolled 125 mm size complete all as specified and directed.
15Supply and fix MS butt hinges medium weight, cold rolled 100mm size complete all as specified and directed.
16Supply & fix Aluminium anodisedbarrel tower bolt 100 mm long of extruded section etc complete all as specified and directed.
17Supply & fix ExtrudedAluminium anodised alloy handles fabricated type 150mm long complete all as specified and directed.
18Supply & fix ExtrudedAluminium anodised alloy handles fabricated type 100mm long complete all as specified and directed.
19Supply & fix aluminium alloy, anodised, sliding door bolts 250mm size with hasp, staple (bolt type) and fixing clips of sheets , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy andfixed etc complete all as specified and directed.
20Hacking out old broken glass (glass thickness, size quality or description) from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and directed.
21Supply & fix sheet glass 4mm thick ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
22Dismantling floor , hearth or wall tiling including cement mortarbedding (but not backing ), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
23Demolition of cement concrete of any description and in any position not otherwise specifically provided for including removing rubbish off the premises complete all as specified and directed.
24Material and labour for 75 mm thick cement concrete 1:2:4 type B 2 (using 40 mm graded crushed stone aggregate) as in sub floor finishing the surface even and smooth with out using extra cementrough to receive complete all as specified and directed.
25Material and labour for 25 mm thick cement concrete 1:2:4 type 1 (using 20 mm graded crushed stone aggregate) as in sub floor finishing the surface even and smooth with out using extra cement complete all as specified and directed.
26M&L for screed bed or bedding layer of 15mm thick in cement mortar 1:4 for laying floor tiles etc all as specified.
27M & L For Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match completed all as specified and directed
28M&L forwhite Non - skidjoint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18Sqm each, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in Cement mortar (1:6)complete all as specified and directed.
29Dismantling wall and ceiling boards of any description including cover fillets complete all as specified and directed.
30Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed.
31Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed.
32Material & labour for 2nd class hardwood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area exc. 3 sqcm and n.exc 6 sqcm, complete all as specified and directed
33Dismantling Timber scantling 40 sq cm and over in section , in any position all as specified and directed.
34M& L for cleansawn Second class hard-wood scantlings with framed work with complete all as specified and directed by Engr-in-Charge.
35Material and labour for preparation of surfaces of wood and wood basedmaterials new or old of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as specified and directed.
36Material and labour for preparation of newplywood and wood based materialsurfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
37Material and labour for providing cement concrete 1:2:4 type B1 40 mm thick (using 20mm graded aggregate ) as over sub base all as specified.
38M & L for PCC (1:3:6) type C-2(40 mm graded stone aggregate) mass concrete as inSurface channels and drain etc complete.
39M & L for PCC (1:3:6) type C-2(40 mm graded stone aggregate) mass concrete as inwalls Retaining walls , anty thickness size or shape including pillastersbuttresses columns , pillersboundry pillers and post 9 includind caps bases)etc complete all as specified .
40Foam work to fair finished surfases face of walls , Retaining walls, abutments perapets and stair case railing and similar work including attached pillasters , buttresses etc vertical or flat completed all as specified and directed.
41Extra for forming fair finishing drain or channels 30 cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc.complete all as specified and directed.
42Taking down cement plaster on brick, concrete block wall or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.
43Material and labour for 10mm thick rendering in cement mortar (1:6) on brick or concrete wall surfaces finished even & smooth W/O using extra cement complete all as specified and directed.
44Material and labour for 15mm thick rendering in cement mortar (1:4) on brick or concrete wall surfaces with WPC complete all as specified and directed.
45Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (HRFR), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (HRFR)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
46All as per item No. 45 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5sq. mm size
47All as per item No. 45 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specifieddirected.
48All as per item No. 45 here in before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire withPVC boxes complete all as specified.
49S&FSocket outlet 2 in 1, 3 pin, 5amp flush type
50S&FSocket outlet 2 in 1, 3 pin, 5 and 15 amp flush type
51Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed.
52Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm ,two to three terminals complete all as specified & directed.
53Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
54Supply and fixing lamp holder, insuleted body with pack plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden boardcompleteall as specified and directed.
55S&F LED lamp 10 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha0.85 (min). Make- Havells/Crompton/Syska
56Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed.
57S&F of new generation energy saving and environmental friendly long life LED building securitylight made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed.
58Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 8 way 200 Amp rated busbarsingle pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
59S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 Vcomplete all as specified and directed.
60S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 Vcomplete all as specified and directed.
61Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
62S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of following sizes.
63Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc)
64Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC.
65Taking downsub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC.
66Supply, installation testing & commissioning of solar Hot water system (Flat Plate Collector) based on indirect transfering of heat, thermosyphon circulation, non pressurised system of capacity 1000 LPD with suitable electric backup including accessories as per manufactre design and recommendation complete all as specified and directed.Note:- Rate of solar includs cost of electric backup, stainless hotwater tank with puf insulation and aluinium cladding 22 SWG, gauges, meters and protection device complete necessary arrangements but does not include the cost of cold water tank, cold water piping and hot water piping
67S&F 3 layer 40 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
68S&F 3 layer 32 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
69S&F 3 layer 25 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed.
70Supply and fix 40 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
71S&F 20 mm bib tap cast copper alloy with crutch or butterfly handle, fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge.
72Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting existing 40 mm PPR pipe and making fusion joint etc.
73S&F PVC water storage tanks of 5000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed.
74Ball brass valves, high pressure, with polythene float and flynut complete of PPR pipe of size 40 mm dia, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
75M&L for PCC 1:3:6 Type C2for foundation of platform, mass concrete with 40 mm gradede coarse agreegete complete all as specified and as directed.
76M & L for 15mm thick rendering on fair faces of brick,stone work/concrete surfaces of wall in CM (1:4), finished surface even and smooth without using extra cement complete all as specified and as directed.
77S&F of framed work such as grill, grating etc with end of bars houldered or riveted or forged into spikers, framed guared bar, barred iron doors, framed balusters, water tank staging and similar work confirming to Fe 290-0 Gde E-165 complete all as specified and as directed.
78S&F PVC water storage tanks of 2000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed.
79S & F , cable XLPE insulated PVC bedded 1100 Volts grade heavy duty cable with PVC solid insulated multistranded aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 16 sqmm 4 core section complete all as specified and directed.
80Supply and laying Double wall corrugated HDPE duct pipe 50mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
81Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed.
82Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
83Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
84S & F of MCCB,04 Pole, capacity 40 Amps with ultimate breaking capacity 16 KA at 415 volts with fixed thermalsettings conforming to IEC 60947 Part-I/IS-13947 Part-I , (Ics=Icu=100%)in the existing panel with suitable connecting copper terminals at site complete all specified and directed. Make :- L&T/Havells/Indoasian
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail