Delhi University has published Tender For Provision Of Power Points On Research Tables And 3 Phase Power Points For Tower A/C Including Refrigerant Pipe Etc. At Kanad Bhawan (Institute Of Eminence, Udhmodya Foundation) , University Of Delhi.. Submission Date for this Tender is 21-05-2024. Electrification Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
fa5a3aa6-7a5e-4f60-b0b5-65a90c5d6a8c.html | Tender Notice | 0 KB |
BOQ_846949.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double door |
2 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door |
3 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
4 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 16 KA,TPMCCB |
5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
6 | Supplying and fixing of following sizes of medium class PVC conduit/batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
7 | 25 mm |
8 | 32 mm |
9 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
10 | 6 Module |
11 | 8 Module |
12 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required |
13 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
14 | 3 x 4 sq.mm |
15 | 3 x 2.5sq.mm |
16 | 3 x 6 sq.mm |
17 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
18 | 15/16 amps switch |
19 | 6 pin 15/16 ams socket outlet |
20 | S/F DLP UPVC trunking compartmentwith cover clip on separates partition left right topinternalangle, flat angle, raise function,flat function cover to body joints mosaic clip & support from mosaicisolation bracket 2 mm thick plastic. (Legrand) 105 mm x 50 mm with all accessories. |
21 | S/F of copper pipe with Lacqer coating , tapping , breezing etc. etc. as required at site. Suitable for 4 ton Tower AC of 3 phase i/c ferruling , cutting , U-traps (at ever 7 meters) etc as per requirement of OEM/Engineer-in Charge. |
22 | 19.05mm and 1 mm thick |
23 | 9.53 mm and 1 mm thick |
24 | Supplying and fixing of 5x6 sqmm unarmoured copper cable for providing power supply i/c making connection as required at site. |
25 | Supplying and fixing of wall stand suitable for 3 phase tower A/C etc. as required. (Angle iron of 40x40x5 mm thick including painting etc. as required at site. |
26 | Indoor Stand |
27 | Outdoor Stand |
28 | Supplying and laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required 3½ X 50 sq. mm |
29 | P/F of drain pipe of 25 mm dia. UPVC pipe with insulation on surface/ recessi/c cutting and making good the sme etc. as required (Astal/Finolex) |
30 | Supplying and fixing nitrile rubber pipe i/c tapping on surface/ recess i/c cutting and making good the same etc. as required. |
31 | Supplying and fixing of 63 ams TPN MCB 415 volt with enclosure i/c making connection etc. as required. |
32 | Supplying and fixing of 18 watts ceiling recessed fitting in the existing MCB DB i/c making connection etc. as required. |
33 | Supplying and fixing of 63 amps TPN MCB 415 volts in the existing MCB DB i/c making connection etc. as required. |
34 | S/f 1 No. RJ-45, 1 Module Box i/c modular plate covering in front on surface connection etc. as required. |
35 | P/F installation, testing and commissioning of 630 amps MCCB 415 volts AC supply complete with connection in the surface enclosure etc. as required at site. (L & T Model No. DN3-630N) |
36 | Supplying and laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required 3½ X 300 sq. mm |
37 | Servicing of ACB"s 1600/1250 amps with proper tools and testing equipments i/c racking out /in tightening of bolts cleaning with petrol/ CRC/ CTC and dry cloths etc. as required at site. |
38 | Servicing the main AMF panel completely i/c removing all the ACB and checking all the parts connection removing all the dust particles, removing the carbon includin wiring and relay etc. as required at site. |
39 | Servicing the main LTpanel comprisign of ACBs and MCCBs with proper tools and testing equipments i/c tightening of bolts (Busbar, ACB etc.) Cleaning of panel with blower and dry cloth etc. as required at site. |
40 | Servicing /overhauling of HT panel with proper tools and testing all the equipments i/c tightening of connection, cleaning taping testing in the presence of authorised personal etc. as required at site. |
41 | Servicing of existing VCB"s with proper tools and testing equipments i/c racking out/ in tightening of bolts cleaning with petrol/ CRC/ CTC and dry cloths etc. as required at site. |
42 | Servicing of existing following panel with proper tools and testing equipments i/c racking out/in tightening of bolts cleaning with petrol/ CRC/ CTC and dry cloths etc. as required at site. |
43 | Control panel |
44 | SUB Panel |
45 | AHU Panel |
46 | A/C panel |
47 | Fire panel |
48 | TRF panel |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail