Madhyanchal Vidut Vitran Nigam Limited has published Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-I, Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction Of Edd-I, Budau. Submission Date for this Tender is 17-05-2024. Electrification Work Tenders in budaun Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-May-2024 | DATE EXTENSION6 | Date | 13-05-2024 |
2 | 14-May-2024 | DATE EXTENSION7 | Date | 17-05-2024 |
FileName | File Description | File Size |
456b12d7-5fc9-45b5-9c82-8710fcd0623c.html | Tender Notice | 0 KB |
BOQ_1595581.xls | Tender Document | 0 KB |
tenderdocument96.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-I, Budaun Approx. distance upto 0-20 Km. Including safe loading and unloading. |
2 | 11 KV 3X185 Sqmm XLPE Cable |
3 | 11 KV 3X185 Sqmm XLPE Cable Box Indoor Jointing Kit |
4 | 11 KV 3X185 Sqmm XLPE Cable Box Outdoor |
5 | 11 KV 3X70 Sqmm XLPE Cable |
6 | 11 KV 3X70 Sqmm XLPE Cable Jointing Kit Outdoor |
7 | 11 KV 3X70 Sqmm XLPE Cable Jointing Kit ST. TH. Outdoor |
8 | 11 KV VCB O/G |
9 | 11 KV VCB I/C |
10 | 33 KV Fuse Set |
11 | 11 KV Fuse Set |
12 | 33 KV Lightening Arrestor |
13 | 33 KV VCB O/D |
14 | 33 KV Control Pannel for Double Transformer |
15 | 33 KV C.T., 400/200/1-1-1 Amp. |
16 | 33 KV Line Isolator |
17 | PCC Pole Support 9 Mtr. Long |
18 | ST Pole Support 11 Mtr. Long |
19 | 11 KV Disc Insulator Composite 45 KN (T&C Type) |
20 | 11 KV Pin Insulator Composite |
21 | 11 KV X-Arm V Type |
22 | ACSR Rabbit Conductor |
23 | L.T. XLPE Armoured Cable Al 3.5x240 Sqmm |
24 | L.T. XLPE Armoured Cable Al 3.5x400 Sqmm |
25 | Stay Complete |
26 | Earthing Complete |
27 | G.I. Wire 6 SWG |
28 | G.I. Wire 10 SWG |
29 | G.I. Wire |
30 | BATTARY CHARGER 24VOLT |
31 | BATTARY Set 24VOLT |
32 | Dismentaling of following old & damaged equipment’sas per norms complete in all respect |
33 | 11 KV VCB O/G |
34 | 11 KV VCB I/C |
35 | 33 KV Lightening Arrestor |
36 | 33 KV VCB O/D |
37 | 33 KV Control Pannel for Double Transformer |
38 | 33 KV C.T., 400/200/1-1-1 Amp. |
39 | 33 KV Line Isolator |
40 | Erection/Installation of following 11 KV Panel (VCB) in control room and cable joint of the panel to pole including earthing, grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply. |
41 | 11 KV VCB I/C |
42 | 11 KV VCB O/G |
43 | Mounting and installation including mechanical/electrical fixing and adjusting of the following equipment on their respective structures including proper adjustment as per RESSPO Norms. |
44 | 33 KV Fuse Set |
45 | 11 KV Fuse Set |
46 | 33 KV Lightening Arrestor |
47 | 33 KV VCB O/D |
48 | 33 KV Control Pannel for Double Transformer |
49 | 33 KV C.T., 400/200/1-1-1 Amp. |
50 | 33 KV Line Isolator |
51 | BATTARY CHARGER 24VOLT |
52 | BATTARY Set 24VOLT |
53 | Laying of control cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms. |
54 | Laying of control cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms. |
55 | Erection of Single PCC pole 9 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms). |
56 | Erection of Single ST pole 11 Mtr. Long in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms). |
57 | Grouting of PCC Pole 9 Mtr. Long & ST pole 11 Mtr. Long with 1:4:8 mixture in size (450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor). |
58 | Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. (All the grouting material shall be provided by the contract for execution of work). |
59 | The work of driving the earthing electrode and making connections with GI wire. |
60 | Dismentaling of following old & damaged Line as per norms complete in all respect |
61 | ACSR Weasel Conductor |
62 | 11 KV 3X70 Sqmm XLPE Cable Old & Used |
63 | Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms. |
64 | ACSR Rabbit Conductor |
65 | 11 KV 3X70 Sqmm XLPE Cable |
66 | Fixing of 11 KV 3x70 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work. |
67 | Fixing of 11 KV 3x70 Sq.mm XLPE Cable jointing kits ST. TH. Outdoor after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work. |
68 | Underground Laying of 11 KV 3x185 sq.mm XLPE cable in double circuit complete in all respect along with road restoration. |
69 | Fixing of 11 KV 3x185 Sq.mm XLPE Cable Inoutdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work. |
70 | Fixing of 11 KV 3x185 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work. |
71 | Underground Laying of L.T. XLPE Armoured Cable Al 3.5x240 Sqmm complete in all respect along with road restoration. |
72 | Underground Laying of L.T. XLPE Armoured Cable Al 3.5x400 Sqmm complete in all respect along with road restoration. |
73 | Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per RESSPO Norms) complete in all respect. |
74 | Erraction/Fixing of Tailess Unit (600 A) (Tailess Unit shall be provided by the contractor as per RESSPO Norms). complete in all respect as per |
75 | Guarding of HT/LT/Telephone Line/Road/River crossing etc. and making net with difference of 1.00 Mtr. Completely including fixing of all channel/angle etc. with proper locking at each support. All type nut & bolt shall be provided by the contractor. |
76 | Fixing & Fabrication of Fuse Set Structure with grouting including cost of cement/BB & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor). |
77 | Fixing & Fabrication of Breaker Structure with grouting including cost of cement/BB & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor). |
78 | Pipe Earthing of VCB (By boring of 4 inch diameter 20 m deep, 40 mm diameter A Class GI pipe is inserted to a depth of 20 m and a holed pipe of 1.5m length is inserted at the bottom, Tighten one end of the MS strip of size 50x6mm with the nut bolt with the neutral of the converter and weld the other end with the GI pipe inserted in the boring for earthing. Putting a socket on the upper part of the pipe (mouth) so that water can be poured into it to retain moisture. To complete the work contractor will provide all material, manpower, T&P, safe carriage of material to worksite. Above work will be carried out under supervision of concerned JE/SDO/EE). |
79 | The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom). |
80 | 11 KV F Clamp with Nut & Bolt |
81 | X-Arm Holding Clamp with Nut & Bolt |
82 | Danger Board |
83 | Al. Lugs for 240 KV Sqmm Cable |
84 | Al. Lugs for 400 KV Sqmm Cable |
85 | 11 KV Guarding Angle |
86 | 11 KV Guarding Angle Clamp |
87 | LT Tailess Unit (600A) |
88 | Control Cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd |
89 | Control Cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd |
90 | Fuse Set Structure with Concrete |
91 | Breaker Structure with Concrete |
92 | Safe back carriage of Following item (if any) from work site to Store Center, Nawada,Budaun approx distance upto 0-20 Km including loading & unloading. |
93 | Material Jarjar Weasal Conductor |
94 | 33 KV VCB O/D Damage |
95 | Old Damaged CT |
96 | 33 KV Control Panel Damage |
97 | 11 KV VCB O/D Damage |
98 | 33 KV Line Isolator Scrap |
99 | 11 KV 3X70 Sqmm XLPE Cable Old & Used |