Madhyanchal Vidut Vitran Nigam Limited has published Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Iii ( Bisauli ) , Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction. Submission Date for this Tender is 17-05-2024. Electrification Work Tenders in budaun Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-May-2024 | DATE EXTENSION6 | Date | 13-05-2024 |
2 | 14-May-2024 | DATE EXTENSION7 | Date | 17-05-2024 |
Sl. No. | Item Description |
1 | The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-III (Bisauli), Budaun Approx. distance upto 0-60 Km. Including safe loading and unloading. |
2 | 11 KV 3X185 Sqmm XLPE Cable |
3 | 11 KV 3X185 Sqmm XLPE Cable Box Outdoor |
4 | 11 KV VCB O/G |
5 | 11 KV VCB I/C |
6 | 33 KV P.T. |
7 | 33 KV Fuse Set |
8 | 33 KV Lightening Arrestor |
9 | 33 KV VCB O/D |
10 | 33 KV Control Pannel for Single Transformer |
11 | 33 KV Control Pannel for Double Transformer |
12 | 33 KV C.T., 400/200/1-1-1 Amp. |
13 | 33 KV Line Isolator |
14 | 33 KV Bus Isolator |
15 | Structure For PT |
16 | PCC Pole Support 8.5 Mtr. Long |
17 | ST Pole Support 11 Mtr. Long |
18 | 11 KV MS T-Off Channel |
19 | Top Channel (125x65x2240 mm) |
20 | 11 KV Disc Insulator Composite 45 KN (T&C Type) |
21 | 11 KV Pin Insulator Composite |
22 | 11 KV X-Arm V Type |
23 | ACSR Weasal Conductor |
24 | ACSR Rabbit Conductor |
25 | Stay Complete |
26 | Earthing Complete |
27 | ABC Cable (3x95+1x70+1x16) sqmm |
28 | ABC Cable (3x50+1x35+1x16) sqmm |
29 | ABC Cable (3x120+1x70+1x16) sqmm |
30 | 3 Phase Distribution Box |
31 | Dropper Channel |
32 | Stringing and sagging of 11 KV line on 11 KV 3x185 sq.mm XLPE cable as per RESSPO Norms. |
33 | Fixing of 11 KV 3x185 Sq.mm XLPE Cable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work. |
34 | Dismentaling of following old & damaged equipment’sas per norms complete in all respect |
35 | 33 KV VCB O/D |
36 | 33 KV P.T. |
37 | 33 KV C.T.,400/200/1-1-1 Amp. |
38 | 33 KV Control Pannel |
39 | 11 KV Old VCB |
40 | Erection/Installation of following 11 KV Panel (VCB) in control room and cable joint of the panel to pole including earthing, grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply. |
41 | 11 KV VCB I/C |
42 | 11 KV VCB O/G |
43 | Mounting and installation including mechanical/electrical fixing and adjusting of the following equipment on their respective structures including proper adjustment as per RESSPO Norms. |
44 | 33 KV VCB O/D |
45 | 33 KV P.T. |
46 | 33 KV Fuse Set |
47 | 33 KV Lightening Arrestor |
48 | 33 KV C.T.,400/200/1-1-1 Amp. |
49 | 33 KV Line Isolator |
50 | 33 KV Bus Isolator |
51 | 33 KV Control Pannel for Single Transformer |
52 | 33 KV Control Pannel for Double Transformer |
53 | Laying of control cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms. |
54 | Laying of control cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms. |
55 | Erection of Single pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms). |
56 | PCC Pole Support 8.5 Mtr. Long |
57 | ST Pole Support 11 Mtr. Long |
58 | Grouting of PCC Pole 8.5 Mtr. Long/ST Pole 11 Mtr. Long with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor). |
59 | Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. (All the grouting material shall be provided by the contract for execution of work). |
60 | The work of driving the earthing electrode and making connections with GI wire. |
61 | Dismentaling of following old & damaged Line as per norms complete in all respect |
62 | ACSR Weasel Conductor |
63 | ABC Cable |
64 | Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms. |
65 | ACSR Weasel Conductor |
66 | ACSR Rabbit Conductor |
67 | ABC Cable (3x95+1x70+1x16) sqmm |
68 | ABC Cable (3x50+1x35+1x16) sqmm |
69 | ABC Cable (3x120+1x70+1x16) sqmm |
70 | Errection and commissioning of 3 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box). |
71 | Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per details given in S.No. 14 as per RESSPO Norms). |
72 | The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom). |
73 | Holding Clamps for LT T-OFF |
74 | 11 KV F Clamp with Nut & Bolt |
75 | X-Arm Holding Clamp with Nut & Bolt |
76 | Stone Pad |
77 | Danger Board |
78 | Barbed Wire |
79 | 3 Phase Distribution Box Clamps |
80 | Piercing Connector |
81 | LT Shackle Insulator |
82 | N&B for Shackle Insulator |
83 | LT Clamps with N&B for Shackle Insulator |
84 | Stay Insulator |
85 | Control Cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd |
86 | Control Cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd |
87 | Safe back carriage of Following item (if any) from work site to Store Center, Nawada,Budaun approx distance upto 0-60 Km including loading & unloading. |
88 | Material ACSR Scrap |
89 | Material Matellic Scrap |
90 | AB cable Scrap |
91 | Material ABC Scrap |
92 | Material GI Scrap |
93 | 33 KV VCB O/D Damage |
94 | Old Damaged CT/PT |
95 | 33 KV Control Panel Damage |
96 | 11 KV VCB O/D Damage |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy