Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Iii ( Bisauli ) , Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction, budaun-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Iii ( Bisauli ) , Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction. Submission Date for this Tender is 17-05-2024. Electrification Work Tenders in budaun Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43279966
Corrigendum : Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Iii ( Bisauli ) , Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction
Open Tender
Indian
Uttar Pradesh
budaun
17-05-2024

Tender Details

Tender For Various Electrification Work In Business Plan-2024-25 Under Various 33 / 11 Kv S / S Area Under Edd-Iii ( Bisauli ) , Budaun, 1 The Work Of Safe Carriage Of The Following Material From Store Center Nawada To Work Site Under The Jurisdiction Of Edd-Iii ( Bisauli ) , Budaun Approx. Distance Upto 0-60 Km. Including Safe Loading And Unloading. 2 11 Kv 3X185 Sqmm Xlpe Cable 3 11 Kv 3X185 Sqmm Xlpe Cable Box Outdoor 4 11 Kv Vcb O / G 5 11 Kv Vcb I / C 6 33 Kv P.T. 7 33 Kv Fuse Set 8 33 Kv Lightening Arrestor 9 33 Kv Vcb O / D 10 33 Kv Control Pannel For Single Transformer 11 33 Kv Control Pannel For Double Transformer 12 33 Kv C.T., 400 / 200 / 1-1-1 Amp. 13 33 Kv Line Isolator 14 33 Kv Bus Isolator 15 Structure For Pt 16 Pcc Pole Support 8.5 Mtr. Long 17 St Pole Support 11 Mtr. Long 18 11 Kv Ms T-Off Channel 19 Top Channel ( 125X65x2240 Mm ) 20 11 Kv Disc Insulator Composite 45 Kn ( T&C Type ) 21 11 Kv Pin Insulator Composite 22 11 Kv X-Arm V Type 23 Acsr Weasal Conductor 24 Acsr Rabbit Conductor 25 Stay Complete 26 Earthing Complete 27 Abc Cable ( 3X95+1X70+1X16 ) Sqmm 28 Abc Cable ( 3X50+1X35+1X16 ) Sqmm 29 Abc Cable ( 3X120+1X70+1X16 ) Sqmm 30 3 Phase Distribution Box 31 Dropper Channel 32 Stringing And Sagging Of 11 Kv Line On 11 Kv 3X185 Sq.Mm Xlpe Cable As Per Resspo Norms. 33 Fixing Of 11 Kv 3X185 Sq.Mm Xlpe Cable Jointing Kits After Carefully Removing The Insulation Of The Cable Duly Plumbing And Taping Of Cable Providing, Fixing And Crimpling Of Proper Size Good Quality Lugs And Complete Work. 34 Dismentaling Of Following Old & Damaged Equipment’Sas Per Norms Complete In All Respect 35 33 Kv Vcb O / D 36 33 Kv P.T. 37 33 Kv C.T., 400 / 200 / 1-1-1 Amp. 38 33 Kv Control Pannel 39 11 Kv Old Vcb 40 Erection / Installation Of Following 11 Kv Panel ( Vcb ) In Control Room And Cable Joint Of The Panel To Pole Including Earthing, Grouting Of Anchor Bolt Of Panel And Making / Repairing Of Pocket For Cable To Insert In Panel From Trench And Fixing, Taping Of Bus Bar With Wiring For Pt. Ac, Dc Connection Including Providing Of Ac & Dc Supply. 41 11 Kv Vcb I / C 42 11 Kv Vcb O / G 43 Mounting And Installation Including Mechanical / Electrical Fixing And Adjusting Of The Following Equipment On Their Respective Structures Including Proper Adjustment As Per Resspo Norms. 44 33 Kv Vcb O / D 45 33 Kv P.T. 46 33 Kv Fuse Set 47 33 Kv Lightening Arrestor 48 33 Kv C.T., 400 / 200 / 1-1-1 Amp. 49 33 Kv Line Isolator 50 33 Kv Bus Isolator 51 33 Kv Control Pannel For Single Transformer 52 33 Kv Control Pannel For Double Transformer 53 Laying Of Control Cable From 33 Kv Panel To Vcb 2X2.5 Sqmm Aramourd Cable Under Ground In Trench Making Proper Complete In All Respect As Per Resspo Norms. 54 Laying Of Control Cable From 33 Kv Panel To Vcb 4X2.5 Sqmm Aramourd Cable Under Ground In Trench Making Proper Complete In All Respect As Per Resspo Norms. 55 Erection Of Single Pole In H.T / L.T Lines Including Fitting Of All Accessories As Per Resspo Norms ( All Necessary Clamps, Nut & Bolts Etc. Shall Be Provided By The Contractor For Execution Of Work As Per Resspo Norms ) . 56 Pcc Pole Support 8.5 Mtr. Long 57 St Pole Support 11 Mtr. Long 58 Grouting Of Pcc Pole 8.5 Mtr. Long / St Pole 11 Mtr. Long With 1:4:8 Mixture In Size ( 450X450x1500mm. ) Including Cost Of Cement / Bb & Sand Required As Per Resspo Norms. ( All Grouting Material Shall Be Provided By The Contractor ) . 59 Grouting Of Stays, 1:4:8 Cc Ratio ( 600X600x300mm. ) As Per Respo Norms. ( All The Grouting Material Shall Be Provided By The Contract For Execution Of Work ) . 60 The Work Of Driving The Earthing Electrode And Making Connections With Gi Wire. 61 Dismentaling Of Following Old & Damaged Line As Per Norms Complete In All Respect 62 Acsr Weasel Conductor 63 Abc Cable 64 Laying, Stringing, Sagging & Jumpring Of Following Conductor Complete In All Respect As Per Resspo Norms. 65 Acsr Weasel Conductor 66 Acsr Rabbit Conductor 67 Abc Cable ( 3X95+1X70+1X16 ) Sqmm 68 Abc Cable ( 3X50+1X35+1X16 ) Sqmm 69 Abc Cable ( 3X120+1X70+1X16 ) Sqmm 70 Errection And Commissioning Of 3 Phase Distribution Box On The Lt Poles ( All The Material Required Shall Be Arranged By The Contractor For Errection And Commissioning Of Distribution Boxes Except Distribution Box ) . 71 Fixing Of Danger Board On Each Location And G.I. Barbed Wire Including Proper Clamping As Per Resspo Norms. ( Danger Board Shall Be Provided By The Contractor As Per Details Given In S.No. 14 As Per Resspo Norms ) . 72 The Following Decentralized Material Shall Be Provided By The Contractor For Execution Of Work As Per Respo Norms ( The Material Shall Be Purchased From Approved Vendor Of Discom ) . 73 Holding Clamps For Lt T-Off 74 11 Kv F Clamp With Nut & Bolt 75 X-Arm Holding Clamp With Nut & Bolt 76 Stone Pad 77 Danger Board 78 Barbed Wire 79 3 Phase Distribution Box Clamps 80 Piercing Connector 81 Lt Shackle Insulator 82 N&B For Shackle Insulator 83 Lt Clamps With N&B For Shackle Insulator 84 Stay Insulator 85 Control Cable From 33 Kv Panel To Vcb 2X2.5 Sqmm Aramourd 86 Control Cable From 33 Kv Panel To Vcb 4X2.5 Sqmm Aramourd 87 Safe Back Carriage Of Following Item ( If Any ) From Work Site To Store Center, Nawada, Budaun Approx Distance Upto 0-60 Km Including Loading & Unloading. 88 Material Acsr Scrap 89 Material Matellic Scrap 90 Ab Cable Scrap 91 Material Abc Scrap 92 Material Gi Scrap 93 33 Kv Vcb O / D Damage 94 Old Damaged Ct / Pt 95 33 Kv Control Panel Damage 96 11 Kv Vcb O / D Damage

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-May-2024 DATE EXTENSION6 Date 13-05-2024
2 14-May-2024 DATE EXTENSION7 Date 17-05-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 37000.0 /-
Tender Value
INR 36.30 Lakhs /-

BOQ Items

Name of Work: For various electrification work in Business Plan-2024-25 under various 33/11 KV S/s area under EDD-III (Bisauli), Budaun.
Sl. No. Item Description
1The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-III (Bisauli), Budaun Approx. distance upto 0-60 Km. Including safe loading and unloading.
211 KV 3X185 Sqmm XLPE Cable
311 KV 3X185 Sqmm XLPE Cable Box Outdoor
411 KV VCB O/G
511 KV VCB I/C
633 KV P.T.
733 KV Fuse Set
833 KV Lightening Arrestor
933 KV VCB O/D
1033 KV Control Pannel for Single Transformer
1133 KV Control Pannel for Double Transformer
1233 KV C.T., 400/200/1-1-1 Amp.
1333 KV Line Isolator
1433 KV Bus Isolator
15Structure For PT
16PCC Pole Support 8.5 Mtr. Long
17ST Pole Support 11 Mtr. Long
1811 KV MS T-Off Channel
19Top Channel (125x65x2240 mm)
2011 KV Disc Insulator Composite 45 KN (T&C Type)
2111 KV Pin Insulator Composite
2211 KV X-Arm V Type
23ACSR Weasal Conductor
24ACSR Rabbit Conductor
25Stay Complete
26Earthing Complete
27ABC Cable (3x95+1x70+1x16) sqmm
28ABC Cable (3x50+1x35+1x16) sqmm
29ABC Cable (3x120+1x70+1x16) sqmm
303 Phase Distribution Box
31Dropper Channel
32Stringing and sagging of 11 KV line on 11 KV 3x185 sq.mm XLPE cable as per RESSPO Norms.
33Fixing of 11 KV 3x185 Sq.mm XLPE Cable jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
34Dismentaling of following old & damaged equipment’sas per norms complete in all respect
3533 KV VCB O/D
3633 KV P.T.
3733 KV C.T.,400/200/1-1-1 Amp.
3833 KV Control Pannel
3911 KV Old VCB
40Erection/Installation of following 11 KV Panel (VCB) in control room and cable joint of the panel to pole including earthing, grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply.
4111 KV VCB I/C
4211 KV VCB O/G
43Mounting and installation including mechanical/electrical fixing and adjusting of the following equipment on their respective structures including proper adjustment as per RESSPO Norms.
4433 KV VCB O/D
4533 KV P.T.
4633 KV Fuse Set
4733 KV Lightening Arrestor
4833 KV C.T.,400/200/1-1-1 Amp.
4933 KV Line Isolator
5033 KV Bus Isolator
5133 KV Control Pannel for Single Transformer
5233 KV Control Pannel for Double Transformer
53Laying of control cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms.
54Laying of control cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd cable under ground in trench making proper complete in all respect as per RESSPO Norms.
55Erection of Single pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms).
56PCC Pole Support 8.5 Mtr. Long
57ST Pole Support 11 Mtr. Long
58Grouting of PCC Pole 8.5 Mtr. Long/ST Pole 11 Mtr. Long with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor).
59Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. (All the grouting material shall be provided by the contract for execution of work).
60The work of driving the earthing electrode and making connections with GI wire.
61Dismentaling of following old & damaged Line as per norms complete in all respect
62ACSR Weasel Conductor
63ABC Cable
64Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
65ACSR Weasel Conductor
66ACSR Rabbit Conductor
67ABC Cable (3x95+1x70+1x16) sqmm
68ABC Cable (3x50+1x35+1x16) sqmm
69ABC Cable (3x120+1x70+1x16) sqmm
70Errection and commissioning of 3 Phase Distribution Box on the LT Poles (All the material required shall be arranged by the contractor for errection and commissioning of distribution boxes except distribution box).
71Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per details given in S.No. 14 as per RESSPO Norms).
72The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
73Holding Clamps for LT T-OFF
7411 KV F Clamp with Nut & Bolt
75X-Arm Holding Clamp with Nut & Bolt
76Stone Pad
77Danger Board
78Barbed Wire
793 Phase Distribution Box Clamps
80Piercing Connector
81LT Shackle Insulator
82N&B for Shackle Insulator
83LT Clamps with N&B for Shackle Insulator
84Stay Insulator
85Control Cable from 33 KV Panel to VCB 2x2.5 Sqmm Aramourd
86Control Cable from 33 KV Panel to VCB 4x2.5 Sqmm Aramourd
87Safe back carriage of Following item (if any) from work site to Store Center, Nawada,Budaun approx distance upto 0-60 Km including loading & unloading.
88Material ACSR Scrap
89Material Matellic Scrap
90AB cable Scrap
91Material ABC Scrap
92Material GI Scrap
9333 KV VCB O/D Damage
94Old Damaged CT/PT
9533 KV Control Panel Damage
9611 KV VCB O/D Damage
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail