Tender For Provision Of Chequered Tiles And Granite Stone, marathahalli-Karnataka

Military Engineer Services-MES has published Tender For Provision Of Chequered Tiles And Granite Stone. Submission Date for this Tender is 21-05-2024. Masonary Work Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

43279146
Corrigendum : Tender For Provision Of Chequered Tiles And Granite Stone
Open Tender
Indian
Karnataka
marathahalli
21-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Provision Of Chequered Tiles And Granite Stone Provision Of Chequered Tiles And Granite Stone Work At Sdi And Certain Sanctioned Works Under Ge Af Marathahalli Bangalore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-May-2024 BOQ CORRIGENDUM BOQ 21-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

Attachment

FileName File Description File Size
f94469c8-7968-40ff-bc2f-7688fc22a826.html Tender Notice 0 KB
BOQ_729667.xls Tender Document 0 KB
TENDER8693.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work : PROVISION OF CHEQUERED TILES AND GRANITE STONE WORK AT SDI AND CERTAIN SANCTIONED WORKS UNDER GE (AF) MARATHAHALLI BANGALORE.
Sl. No. Item Description
1Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness ( below or above ground level) completeall as specifiedand as directed.
2M&L for75 mm thickPCC 1:4:8(40 mm graded aggregate)type D2 as in sub- base of floor complete all as specified and directed.
3Material and labour for 15 mm thick screed bed or bedding layer in CM 1:4 for laying of tiles, complete all as specified and directed.
4Material and labour for Chequered cement concrete tiles 20cmx20cmx25mm thick, set, jointed and pointed with white cement and pigment in floors, complete all as specified and directed.
5Material and labour for PCC 1:2:4, type B1 using 20mm graded stone aggregate as in coping, plinth courses, bed blocks including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
6Taking down Cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
7M&L for rendering 10mm thick cement mortar in 1:3 onbrick or concretesurfaces finished even & rough to receive tilescomplete all as specified and directed.
8M & L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
9Removing building materials etc.to a distance 5 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified.
10M & L for one coat of oil bound distempering on walls including preparation of old painted surface complete all as specified and directed.
11M & L for one coat of white washing on ceiling including preparation of old paintedsurfacecompleteall as specifiedand as directed.
12Taking down Chowkhats or frames but with shutters (without taking off shutters from the frame )exc 1.5 sq. M but n exc 4 sq. M eachand removal from site completeall as specifiedand as directed.
13M & L for framed work such as grill, gratings, etc with ends of bars shoulderedand /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work corn-conforming to Fe.290. Gde -E-165, complete all as specified and directed.
14S & F collapsible gate top hung, consisting of chanel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified, erected in position and securing runners with hold fast and brackets, completeall as specifiedand as directed.
15M&L for painting on new steel or iron surface of any description, over 10cm in width or girth,not otherwise described applying two coats of synthetic enamel paintover a coat of read oxide zinc chrome primer including preparation of surfaceall as specified and directed.
16Cutting holes in brick walls exc half brick but n.exc one brick depth, built in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, complete all as specified and directed.
17S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron) and fixing/finished with past on gap of the surface in contact with stone masonary wall/brick wallcomplete all as specified and directed. Note: Glass will be measured and paid seperately.
18S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
19S&F for pressed steel frames of size 105 X 60 mm with one or more rebates including necessary fixing lugs hinges, locks strike plate etc(thickness ofsheet shall be 1.25mm) and making good the plaster of wall in CM 1:6. complete all as specified and as directed.
20M&L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for filling in bed block of hold fast etc complete all as specified and as directed.
21S&F Aluminium alloy anodised Sliding bolt 300mm long with hasp, staple(bolt type and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy completeall as specifiedand as directed.
22S&F Aluminium anodised bolts barrel towerbolts 200mm long of extruded section completeall as specifiedand as directed.
23S&F Aluminium handles 150mm size cast type anodised completeall as specifiedand as directed.
24S & F Floor door stopper 150mm length of cover plate aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in doors , complete all as specified and directed.
25Demolition of stone slabs and tiles of any description or thickness in floors completeall as specifiedand as directed.
26M & L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishinglaid over 15 mm thick 1:4 CM complete all as specified and directed.
27M & L for 20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 10 mm rendering as in backing coat in CM 1:3 complete all as specified and directed.
28Dismantling wrought iron or mild steel work of any description not otherwise provided for completeall as specifiedand as directed.
29Demolition of stone/Brick masonry built-in cement mortarincl all quions arches, pillars etc complete all as specified and directed.
30Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
31Excavating in trenches not exceeding 1.5mwide andnot exceeding 1.5m in depth and getting out in hard/dense soilfor foundationcompleteall as specifiedand directed.
32M&L for cement concrete 1:4:8 type D-2 using 40mm aggregate as in foundations, filling and mass concrete etc complete all as specified and directed.
33M & L for Providing precast cement concrete solid blocksmasonary type C1, 1:3:6 20mm graded aggregate exc 10 cm in width and setting in cement mortar 1:6 all as specified and directed.
34Plain cement concrete (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in benching, bed plates, coping and the like including weathering, slightly rounded or chamfered angles and throating completeall as specifiedand as directed.
35M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth completeall as specifiedand as directed.
36S&F Glazed ceramic tiles size 30x60 cm fixed to wall ( sample of tile as approved by GE), including set in CM (1:4) all relevent adhesive matterial if any grouting etc complete all as specified and directed.
37M & L for 100mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors and pavings etc, finishingfinishing of surfaceeven and fair, complete all as directed by Engr-in-charge.
38Forming 12 mm thick expansion joints in 100mm thick concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound Grade ‘B’,complete all as specified and directed.
39S&F Stainless sleel lettering for camp area name size (8 inch high, 4inch wide) complete all as specified and directed.
40M & L for Surface excavation n.exc(not exc) 30 cm deep and averaging 15cm deep and getting out in soft loose soil completeall as specifiedand as directed.
41M & L for rendering 10 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smoothwithout using extra cement completeall as specifiedand as directed.
42Material and Labour for pre cast cover slab using PCC (1:2:4) type B1 and set in CM 1:6 with top surface finished even & fair complete all as specified complete all as specified and as directed.
43Material and Labour for TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending spirally or hoping for columns, hooking ends & binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips completeall as specifiedand as directed.
44M & L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillers, windows-cill, outdoor platform and like in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with of pigment to match with shade of granite etc., including 20mm screed bed in CM1:4 complete all as specified and as directed.
45M & L for sand filling pathway in layers n. exc 30cm thick including watering and consolidation completeall as specifiedand as directed.
46M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and nopigment laid over and including machine compacted sand cushion all as specified and directed.etc completeall as specifiedand as directed.
47Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), includingmaking joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), includingmaking drainage opening wherever required completeall as specifiedand as directed.
48Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil, complete all as specified and directed.
49M&L for PCC 1:3:6, type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
50S&F Structural steel worksas roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pieces, cleats etc conforming to Fe-410-W (Gde-E-250) quality A, Complete all as specified and directed.
51M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmentComplete all as specified and directed.
52S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed by Engineer-in-charge.
53S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specifed and directed by Engineer-in-charge.
54M&L for painting new steel surfaces of any description incl preparation, priming with red oxide zinc and two coat synthetic enamel paint, width or girth over 10cm, not otherwise described complete all as specified and directed.
55M&L for Plain cement concrete 1:2:4,Type B-1 (using 20mm graded stone aggregate) 75mm thick complete all as specifiedand as directed.
56Demolition of brick/stone work built in cement mortar complete all as specified and as directed.
57Material & Labour for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundation bed of wall etc complete all as specified and directed.
58Material and labour for precast cement concrete block masonry with solid blocks in PCC 1:3:6, type C-1 using 20mm graded aggregate exceeding 10cm width and setting in CM 1:4 complete all as specifiedand as directed.
59M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specifiedand as directed.
60Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing servicable tiles to store and rubbish off the premises complete all as specifiedand as directed.
61M & L coloured non skid ceramic tiles 7 to 8mm thick area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 1:4, 15mm thick completeall as specifiedand as directed.
62S&F false ceiling grid of size 600 x 600 mm system using hot dipped galvanized steel section with precoated capping, main tee of size 24x32 mm having 0.27mm thick at every 1200mm centre to centre, cross tee of size 24x27 mm having 0.25mm thick at 600 mm centre to centre and wall angleof size 19x19 mm having 0.35 mm thick fixed to the periphery of the wall, and suspended at every 1200mm centre to centre in both directed using 2.00 mm thick GI wire and fixing 600 x 600 x 16 mm mineral fibre tegular edge ceiling tiles of RH90 complete all as specified and as directed.
63Cutting of tile to required size and length to casting wall, floorhearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises.
64Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) completeall as specifiedand directed.
65Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide
66M&L for Reinforced cement concrete (nominal mix) Type B0 1:2:4 (12.50 mm gradedaggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likeall as specified and directed.
67M&L for 12 mm thick prelaminated particle board, exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work, all as specified and directed.
68M & L for 2nd class softwood plain fillets, exc 13 & n.exc 25 sq.cm square, rectangular in section,clean sawn, secured with nails or brands, complete all as specified and directed.
69S & F75mm Butt Hinges, extruded brass with mild steel hinge pin, bright polished and fixed, Type B-12, complete all as specified and directed.
70S&F 150mm extruded brass handles, fabricated type polished, completeall as specified and directed.
71S&F 40mm dia, brass cupboard knobs fixed with nut, screw and washer of brass, polished, complete all as specified.
72S&F Brass Locks, drawer, grade I, size 50mm, 4 levers complete all as specified.
73M & L for preparation of old surface and applying one coat of oil bond distempering on wallscomplete all as specified and directed.
74S&F Aluminium extruded section body, Door closer hydraulically regulated, deisignation No.3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed, complete all as specified and directed.
75S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steelcrews, all complete.
76S&F Powder Coated aluminium door shutters (minimum thickness of powder coating 50 micron) aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws with etc. complete all as specified. Note: Glass will be measured and paid seperately.
77S&F Aluminium Mortice lock of4 levers in vertical type ofsize 100 mm complete all as specified and directed.
78S&F 5.5 mm thick tinted sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each panelfixed to alluminium frame works with neccessary rubbber bedding complete all as specified and directed.
79M & L for point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specifiedand directed by Engr -in -charge for One light point / one bell point controlled by one, one way switch. (a)One 5 Amps socket point on independent board.
80All as per item No.79above, but, wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent board.
81Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
82S & F modular socket 06/16 Amps 2/3 pin combined 2 modulecomplete all as specified & directed.
83Supply & fixing modular switch 16 Amps 1 modulecomplete all as specified & directed
84S & FMCB SPN 40Amps, "C" series, 240 V complete incl making conections all as specified and directed.Make -Havellsor equivalent
85M & L for sub main wiring complete with two runs of 4 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 4Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
86Supply and fixing wall fan ofsingle phase 230/240V of size 400 mm sweep and grouting withnut , bolts & Fastenaron the wall and make good the disturbed surface and electric connection with 1.5 Sqmmthree core PVC insulated round flexible copper conductor and sheathed cable complete all as specified and directed .
87Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,(fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. as directed
88Taking down carefully main switches DB"s/MCB DB"s and making good the disturbed surfaces of walls etc complete all as specified and directed
89M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, including metal flux boxes of suitable size and modular white plate with frame for mounting modular switches, sockets and regulators etc,including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the following:- (a) One 6 Amps socket point on independent board
90All as per item No.89 above, but, wiring completewith 2.5 sqmm for 3 pin 16 Amps socket multipurpose on independent board
91M & L for sub main wiring complete with four runs of 4 x 6 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 1x 4 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
92M & L for sub main wiring complete with four runs of 4 x 4 Sqmm single coreFRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 1x 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
93S & F modular socket 6 Amps 2/3 pin combined 2 modulecomplete all as specified & directed.
94S & F modular socket 16 Amps 2/3 pin combined 2 modulecomplete all as specified & directed.
95Refixing of DB SPN 8 way and making good after civ works as per existing site reqd complete all as specified and directed
96Refixing of modular socket 16 Amps 2/3 pin, 2 module complete all as specified and directed.
97Refixing of modular socket 6 Amps 2/3 pin, 2 module complete all as specified and directed.
98S & F MCCB DB Vertical TPN 4 way "A" frame,including MCCB TPN 63 Amp breaking capacity 16 KA- 02 nos, double door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match complete all as specified and directed. Make- Havells or equivalent
99S & F MCB DB TPN 4 way, Double door flush to wall including all cutting etc on wall. Complete all as specified and directed
100Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / layingunder ground electric cable including taking out old bricks from trenches and separating serviceable bricks and set aside for reuse complete all as specified and as directed.
101Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
102Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
103Supply, laying riddled earth soil conformed IS-1255, cushioning to cables with a layer of riddle earth soil 15cm deep before laying the cable and 8 cm depth after laying of cable, complete all as specified.
104M&L for brick protection cover on cable with sub class "B" brick laid dry flat adjacent to each other complete all as specified and directed.
105Supply and fixingof GI tubing, light grade, 32 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
106M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations for electric poles, filling and mass concrete complete all as specified and directed.
107Supply and laying cable XLPE insulated screened, PVC bedded, galvanised, steel strip or wire armoured, electric power cable, (heavy duty) 1100 volts grade, with stranded aluminium conductor of size 4 core x 10 Sqmm.
108Supply and fixing PVC insulated copper flexible cable2.5 Sqmm 3 core, 1100 volts grade complete all as specified and directed.
109Supply and fixingLED landscape light LED Spike/ Bush light of cap 9 wattwith die-cast aluminum housing designed for rugged outdoor usage & IP 65 protection complete all as specified and directed.
110Supply and fixing30 watt floodlight luminaire with polycarbonate optics, pressure die-cast housing along with IP66 ingress protection 4kV inbuilt surge protection for area lighting complete all as specified.
111M&LforRigid non metallic PVC conduit ISI marked, medium grade, inclusive of all fitting such as tees,bends. Junction boxes, elbows saddles. Pipe hooks,couples and lock outs etc 20 mm external dia, fixed as required complete and making good disturbedsurfaces in repairs all as directed.
112S & F MCB SP 6-32 Amps, "C" series, 240 V complete incl making conections all as specified and directed.
113S & FMCB SPN 32Amps, "C" series, 240 V complete incl making conections all as specified and directed.
114S & FMCB DB SPN 8Way with 200 Amps rated busbar, Double door, flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existingcomplete all as specified and directed.
115Supply and fixing Acrylic LED letter Sign boardupto 40 Nos of LED letters for SDI Main Gate including all internal and external accessories, wiring,connections complete all all as specified and directed by Engr-in-Charge.
116Taking down carefully copper/aluminium point wiring of any type of batten or conduit (Light, Fan, Socket or power) complete removing material from site and making good the disturbed surfaces of walls, roofs etc including two coats of white/colour washing/distempering etc to match the existing complete all as directed by Engr-in-Charge.
117Taking down ceiling fan/ wall fan of any size, sealing cable end,dismantling blades and removing fan and blades to store and refixing the same as per existing site required and connecting up including provision of cable from ceiling rose or connector to wall fan complete all as specified and directed by Engr-in-Charge.
118Taking down carefully by unscrewing from tube light fittings/ decorative light fittingsetc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) and refixing the same as per existing site required complete all as specified and directed by Engr-in-Charge.
119M & L point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of suitable size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, incl mild steel terminal boxes modular switches & plates including all cutting/chases etc in wallsand including continuousearth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the following:- (a)One light point /Fanpoint controlled by one switch.
120Supply & fixing modular switch 06 Amps 1 module complete all as specified & directed
121Supply and fixingin repair 36W LED Fitting, 2 x 2recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED drivercomplete all as specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail