Military Engineer Services-MES has published Tender For Repair And Maintenance Of E/M Items At Hq Afc, 15 Fbsu And 153 Sqn Under Ge Brichgunj.. Submission Date for this Tender is 20-05-2024. Electrical Maintenance Tenders in South Andamans Andaman And Nicobar Islands. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
f9dd60c3-6309-468c-8d24-e257c49cba17.html | Tender Notice | 0 KB |
8482Tender.pdf | Tender Document | 0 KB |
BOQ_729688.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed. |
2 | M&L Point wiring complete with 1.5 sqmm single coreFRLS PVC insulated andunsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and capingand all accessories fixed to walls / roofs / ceiling etc. and including1.5 sqmm copper cableFRLS PVC insulated andunsheathed cable 1100 volts as earth continuity conductor and connected to common earth dolly for(a) One light point/Bell pointcontrolled by one switch, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover/Pre moulded PVC switch board for housing the switches, socket outlets, fan regulators etc., all as specified and as directed. |
3 | (b) One fan point controlled by one switch and one regulator |
4 | (c) One 3 pin switch socket outlet point 5 amps on same board with other switches. |
5 | (d) One 3 pin switch socket outlet point 5 amps on independent board. |
6 | M&L for point wiring with 4 Sqmm FRLS PVC insulated and unsheathed single core stranded copper conductor cable 1100 volts in PVC casing & caping for 2 in one, 3 pin 5 Amps & 15 Amps multi purpose socket on independent board and existing cast iron or pressed steel terminal box with new laminated sheet top cover 3 mm thick, including PVC insulated & unsheathed copper conductor cable 4 SqmmFRLS PVC insulated andunsheathed cable 1100 voltssize for earth continuity conductor and connected to earth dolly including painting to existing sunken boxes with anticorrosive bituminous paint after through cleaning complete all as specified and directed. |
7 | M&L for point wiring as per colour coding with 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 19 mm thick rigid non metallic PVC concealed conduit medium quality including new sunken terminal boxes duly epoxy painted and 3mm thick plastic laminated sheet top cover and continuity earth wire PVC insulated copper conductor standard unsheathed of size for(a) One light point/Bell pointcontrolled by one switch 1.5sqmmincluding Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases forconcealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. complete all as specified and as directed. |
8 | (b) One fan point controlled by one switch and one regulator |
9 | (c) One 3 pin switch socket outlet point 5 amps on same board with other switches. |
10 | (d) One light point controlled by two two way switch. |
11 | (e) One 3 pin switch socket outlet point 5 amps on independent board. |
12 | All as per item at sl No.4 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuty conductor, complete all as specified and as directed. |
13 | Supply and fix Surface/Recessmounted LED 2x2Square type 32 w within die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceablefitting of any wattage, complete all as specified and directed. |
14 | S&F LED lamp 9W, 230 Volt complete all as specified and directed. |
15 | Supply and fix 10 w LED bulk head fittingprewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceablefitting of any wattage, complete all as specified and directed. |
16 | S&F in replacement of exhaust fan 250 mm sweep complete all as specified and directed. |
17 | S&F switch piano flush type single pole one way 5 amps, complete all asspecified and as directed. |
18 | S&F switch piano flush type single pole one way 15 amps, complete all asspecified and as directed. |
19 | S&F switch socket combination 2 in 1, 3 pin (mult pin) 5 amps flush/box type, complete all as specified and as directed. |
20 | S&F switch socket combination 2 in 1, 5 and 15 amps flush/box type, complete all as specified and as directed |
21 | S&F ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed. |
22 | S&F lamp holder PVC body with back plate suitable for batten fittings, complete all as specified and as directed |
23 | S&F bell push single phase, 240 Volts, 50 Hz, complete all as specified and as directed |
24 | S&Fswitch piano flush type single pole two way 5 amps, complete all asspecified and as directed |
25 | Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed. |
26 | S&Fbell Ding Dong 240 Volts 50 Hz complete all as specified and directed. |
27 | S&F Modular switch 1 way 5 A, 1 module complete all as specified and directed. |
28 | S&F Modular switch 1 way 15 A, 1 module complete all as specified and directed. |
29 | S&F Modular Bell push 5A, 1 module complete all as specified and directed. |
30 | S&F modular socket outlet, 2/3 pin combined , 6 Amps, 2 module, 230 volts complete all as specified and directed. |
31 | S&F modular socket outlet, 2/3 pin combined , 6/16 Amps, 2 module, 230 volts complete all as specified and directed. |
32 | S&F modular fan step regulator, 230 V, AC, 120W - 2 module complete all as specified and directed. |
33 | S&F in repair metal enclosure distribution board SPN, 12way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed. Note:- Incoming & Outgoing connections from the DB shall be provided with proper lugs/thimbles etc. |
34 | All as per item Sr No 26.00 above butdistribution board SPN, 8 way 240 volts complete all as specified and directed. |
35 | All as per item Sr No 26.00 above butdistribution board SPN, 4 way 240 volts complete all as specified and directed. |
36 | All as per item Sr No 26.00 above butdistribution board SPN, 2 way 240 volts complete all as specified and directed. |
37 | S&F sheet metal enclosures Loadline vertical distribution board TPN, 4 ways 415 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs and in and including 63A MCCB ,16KA as incomming complete all as specified and as directed including taking down old MCB DBs completeincluding cutting chases pinning in making good to facings where required and pointing in cement mortar 1:3 ends of edges of landing,steps, cills sunsades,shelves,lintels,etc and cutting for concealed conduit wiring etc and making good,cutting not exc 10 cm girth in brick wall complete all as specified. |
38 | S&F in repair MCB single pole and neutral, 240 volts, 40 amps,10KA,230V, B series complete all as specified and as directed. |
39 | S&F in repair MCB single pole 240 volts, 5 to 32 amps,10KA,B series ,230v complete all as specified |
40 | S & F in repairs Single Pole and Neutral Enclosure with Two Pin Earth Plug and Socket complete with one MCB, SP, 20 Amps, 240 Voltsall as specified and as directed. |
41 | M & Lin repairs for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessoriesfixed to wall/ roofs/ floors etc with one run of 6 sqmm FRLSsingle core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre. |
42 | All as per above item Sr No 31.00 but of size 4 sqmm complete all as specified and as directed. |
43 | All as per above item Sr No 32.00 but sub main wiring of size 2.5 sqmm complete all as specified and as directed. |
44 | M & Lin repairs for circuit wiring complete with two runs of 1.5 Sqmm FRLS single core PVC insulated unsheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessoriesfixed to wall/ roofs/ floors etc with one run of 1.5 sqmm FRLSsingle core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed.. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre. |
45 | S&F in repair PVC Casing caping of size 25 mm with accessories like PVC saddles, bend,Tees,Elbow and screws etc. |
46 | All as per item Sr No 35.00 above butPVC Conduit of size 25 mm complete all as specified and as directed |
47 | S & F in repairs Heavy duty PVC Domestic Surface type for Switches of following sizes (a) 1 Gang Box |
48 | 2 Gang Box |
49 | 3 Gang Box |
50 | 4 Gang Box |
51 | 5 Gang Box |
52 | 6 Gang Box |
53 | 7 Gang Box |
54 | S&F energy efficient LED batten 22 W with aluminum housing nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours includinglamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as directed. |
55 | S & FLED mirror light fitting 1 x 10 Wattprovided with high output diffuser including high efficiency electronic driver complete with LED lamp, prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceable mirror light fitting of any wattage, complete all as specified and directed. |
56 | S&F Star surface mounted LED 12 w Round type within die cast aluminium housing finished in premimum white powder coating prewired upto connection block and connecting with three core PVC copper flexible cable of size 1.5 Sq.mm from ceiling rose to connector block, including taking down old unserviceablefitting of any wattage, complete all as specified and directed. |
57 | S&F in replacement of LED Bldg security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed. |
58 | Dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding with new rotor shaft the ceiling fan of size 1200mm/1400mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed. |
59 | S&F in repalcement canopy of ceiling fan, complete all as specified and as directed. |
60 | S&F in repalcement ceiling fan hanging clamp with bush, locking pin and nut and bolt, complete all as specified and as directed. |
61 | Dismantling and taking down ceiling fan of any size/sweep from existing position complete with blades, down rod and canopy etcand servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item) |
62 | S&F ball bearing suitable for ceiling fan of any sweep and make complete all as specified and as directed. |
63 | S&F down rod of appropriate sizesuitable for ceiling fan of any sweep and make complete all as specified and as directed. |
64 | Supply and replace in repairs fan condenser 2.5 mfd, AC 440 volts, 50 Hz complete all as specified and as directed. |
65 | Taking out and dismantling the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the exhaust fan of size 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling refixing at same/ required location, complete all as specified |
66 | All as per item No49 above but PVC Ventilation fan 200 mm sweep complete all as specified and directed. |
67 | S&F and testing exhaust fan of size 250 mm , 230V AC complete all as specified and directed. |
68 | S&F in repairs condensor 4/3.5 mfd, AC 230 volts, 50 Cycles, complete all as specified and directed. |
69 | S&F in repairs ball bearing suitable for exhaust fan of any sweep and make complete all as specified and as directed |
70 | Taking down exhaust fan of any size/sweep from existing position complete with blades from brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position complete all as specified and directed. (Note: cost of spare parts shall be measured and paid separately as supplied only. The cost of labour for replacement of spare parts deemed to be included under this item) |
71 | Material & labour, earthing complete with galvanize steel earth plate electrode 60 cms x 60 cms x6.00mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected togalvanised earth lead wire 4.0mm by means of bolts ,nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe light grade 40 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh ,including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No, 5 of MES Sch Part-1 (2009), complete all as specified and directed. |
72 | Taking down and refixingof unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directed. |
73 | M&L Taking down and refixing of electric water heater (Geyser) of any capacity for carry out necessary repair on it all as specified and directed. For Maintenance of storage type electric water heater (Geyser )of any capacity comprising of the following activities. (a) Inspection taking down, opening, dismantling, descaling, brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling. (b) Check and connect Earth continuity of electric items. (c) Checking and adjustment of pressure release valves. (d) Check maintenance and refix thermostat and its functioning. (e) Checking of dead weight, cleaning and seal and ensuring that vent hole is not blocked . (f) Visual examination of fusible plug. |
74 | S&F in repairs Heating element of 1500 watts, 240 volts suitable for existing complete all as specified and as directed. |
75 | S&F in repairs Thermostat element suitable for 25 ltrs capacity water heater, suitable for existing complete all as specified and as directed. |
76 | S&F in repairs Geyser "Hot & Cold" PVC pipe line connecting to stop cock off 15mm dia, 450mm length all as specified and as directed. |
77 | S&F scotch screw 10mm for installation of water heater |
78 | S&F neon bulb red and green in colour forindication of water heater |
79 | S&F top cover of water heater |
80 | Supply only bottom cover of water heater |
81 | S&F in replacement of wall mounting fan, electric driven single phase 230 volts, oscillating type, 300 mm sweep, high quality ABS base with high speed motor including taking down of old unsv item all as per specified. |
82 | M&L for dismantling the wall mounted fan of any size/sweep from existing position and rewinding with new rotor shaft complete with bladesfrom brackets etc and servicing the same properly by cleaning, greasing, oiling replacing the unservicable spare parts etc, and reassembling and refixing in the same position all as specified and as directed. |
83 | Supply and fix ball bearing suitable for wall mounted fan of any sweep and make complete all as specified and as directed. |
84 | Taking out and the burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the wall mounted fan of size 200 to 300mm sweep motor with super enamelled copper winding wire of suitable SWG including varnishing, baking in oven and reassemling complete all as specified and as directed. |
85 | Supply and fix wall mounted fan covering Net |
86 | Supply and fix wall mounted fan blade |
87 | M&L for servicing of window type air conditioner of 1/1.5/2.0 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed. |
88 | Dismantling the following unservicable items from window type air conditioner of capacity 1/1.5 /2 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed for following:-Compressor suitable for 1.5 ton |
89 | Compressor suitable for 2 ton |
90 | Blower motor single phase, 1/5 hp, 1100 rpm, 130 watts, 240 volts |
91 | Running capacitor 50 mfd 230 volts |
92 | Blower motor fan blade set |
93 | Rubber mounting bush for blower motor |
94 | S&F in replacement copper condensor coil suitable for 1/1.5/2 T Split/window AC complete all as specified and as directed. |
95 | S&F in replacement copper evaporatorcoil (cooling ) suitable for 1/1.5/2 T Split/window AC complete all as specified and as directed. |
96 | M&L for servicing of split type air conditioner of 2.0/1.5/1 Ton capacity any make including, cleaning of air filter, condensing coil and cooling coil with CTC including refixing the unit complete in position all as specified and as directed. |
97 | Dismantling the following unservicable items from split type air conditioner of capacity 1/1.5/2.0 Ton of any make and any type and replacing the same with new one including testing and commissioning the same all as specified and as directed for following:- Compressor for 1/1.5 ton split type air conditioner |
98 | Compressor for 2.0 ton split type air conditioner |
99 | Oudoor fan motor for 1/1.5 ton split type air conditioner |
100 | Oudoor fan motor for 2.0 ton split type air conditioner |
101 | Indoor Blower motor for 1/1.5 ton split type air conditioner |
102 | Indoor Blower motor for 2.0 ton split type air conditioner |
103 | Starting capacitor for 2.0 ton split type air conditioner, 100/120 mfd 230 volts |
104 | Starting capacitor for1/1.5 ton split type air conditioner, 80/100 mfd 230 volts |
105 | Running capacitor for 1/1.5 ton split type air conditioner, 36 mfd 230 volts |
106 | Running capacitor for 2.0 ton split type air conditioner, 45 mfd 230 volts |
107 | PCB Electronic control board for 1.5/2.0 ton split type air conditioner |
108 | Hand Remote set for 1.5/2.0 ton split type air conditioner |
109 | Outer brass valveof size 5/8" for out door unit of split AC 2 ton |
110 | Outer brass valveof size 3/8" for out door unit of split AC 2 ton |
111 | Outer brass valveof size 1.5" for out door unit of split AC 1.5 ton |
112 | Outer brass valveof size 0.25" for out door unit of split AC 1.5 ton |
113 | MS Stand for outer unit of split AC 1.5/2 ton capacity. |
114 | Expansion valve with capillary for window/split type AC |
115 | Dismantling the following unservicable items from water cooler storage type 40/80cooling of any make and replacing the same with brand new one including testing and commissioning the same all as specified and as directed for following:-Compressor |
116 | Fan motor |
117 | Thermal over load protector |
118 | Starting relay |
119 | Thermostat |
120 | Starting capacitor 80/100 mfd 230 volts |
121 | Running capacitor 10 mfd 230 volts |
122 | Self closing tap of chromium plated brass, size 15mm |
123 | M&L for charging of refrigerant gas R-134 (a) in Refrigerator/watercooler of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed. |
124 | M&L for charging of refrigerant gas R-22/ R-410/R-32 for Air conditioners of any make and type, including testing and commissioning the the equipment, complete all as specified and as directed. |
125 | M&L for pressure testing the compressor unit including connecting pipe line with nitrogen gas and holding the appropriated pressure for approved period (as per manufactureal instruction) and rectify the leakages by means of welding, soldering/brazing etc for window/splitt type air conditioner/ water cooler/refrigerator of any capacity and make, including testing and commissioning complete all as specified and as directed. |
126 | M&L for preparation of old painted surface of water cooler 40/80 ltrs cooling capacity and painting the same with two coats of synthetic enamel paint over a coat of red oxide primer, including removing corroded portion of steel surfaces and provisions of new mild steel sheet 18 guage fixed in position duly welded and suit the adjoining complete all as specified and as directed. |
127 | M&L Repair to voltage stabilizer 5.0/4.0 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed. |
128 | M&L Repair to voltage stabilizer 0.5 to 3 KVA capacity AC, SP 240 volts including replacement of relays and electronic printed circuit board (PCB) with brand new relays & PCBs and testing on completion all as specified and as directed. |
129 | M&L in Replacement of voltage stabilizer 5 KVA capacity AC, SP 240 volts complete all as specified and as directed. |
130 | S&F sheet metal enclosure with industrial type socket with plug top and earth plug and socket complete with one single pole MCB 20 amps 240 volts including taking out old MCB plug and socket complete all as specified and as directed. |
131 | M & L for AC point sub main wiring with 3 runs (Phase, neutral, earth) of 4 Sq.mm PVC Insulated Unsheathed single corecable, 1100 Volts Grade Multistranded with Copper Conductor drawn through and including PVC Casing and Caping (or) PVC conduit of 20mm dia non metalic rigid with conduit accessories fixed to walls/roofs/floors etc and One run of 4 Sq.mm Single Core Multistranded Copper Conductor as earth continuity conductor all as specified and as directed.. (Note: 2 runs of 4 Sq.mm & 1 run of 4 Sq.mm earth conductor will be measured as one running metre) |
132 | Disconnecting the electrical connections, making system pumping down, and removing the split type A/C of capacity1.5 / 2 ton including copper pipe from the existing position and shifting the same to the new location, re-connecting the A/C after makingsuitablehole in the wall, providing necessary connections, including closing the hole with brick masonry and finishingsurfaces tomatch withthe existing complete all as specified and directed. |
133 | Supply and fix in repair of PVC conduit 20mm for drain out of air conditioner, complete all as specified and as directed. |
134 | Supply and fix in repair copper tube of size 5/8 with insulation rubber hose, complete all as specified and as directed. |
135 | Supply and fix in repair copper tube of size 1/2 with insulation rubber hose, complete all as specified and as directed. |
136 | Supply and fix in repair copper tube of size 3/8 with insulation rubber hose, complete all as specified and as directed. |
137 | Supply and fix in repair copper tube of size 1/4 with insulation rubber hose, complete all as specified and as directed. |
138 | M&L for cleaning of water storage tanks / Service tanks of the capacity as mentioned below on roof top of bldgs upto forth storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properlyinside with bleaching powder, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white/black bold letter such as"TANK CLEANED ON" _____(date), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours. (ii) Contractor shall maintain a register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted to JE E/M alongwith RAR. (iii)Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv)All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept. for following:- PVC tank upto 500 litres |
139 | PVC tank upto 1000 litres |
140 | PVC tank upto 2000 litres |
141 | PVC tank upto 3000 litres |
142 | PVC tank upto 5000 litres |
143 | Over Head reserviour of capacity 1.2 lakh Ltrs |
144 | Over Head reserviour of capacity 40000 Ltrs |
145 | RCC Semi UG Sump 20000 litres |
146 | Collect the sample of water of 5 litres each from user end, after tank cleaning and sending it toGovt approved lab on same day for testing of water as per IS in a cleaned container and necessary reports will be submitted complete all as directed by Engr-in-Charge. |
147 | S&F in repair PVC tank cover top for water storage tanks suitable for 500/1000 ltrs capacity as per existing colour complete all as specified and as directed. |
148 | All as per Item Sl Item No 94.00 here-in-before but of size 2000/5000 ltrs capacity |
149 | S&F in replacement of Rotational moulded polyetheylene (HDPE) double layered ISI marked Water Tanks of 500 Ltr capacity Cylindrical & Vertical Type, ISI marked, hoisted and fixed in position with PVC cover including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. |
150 | All as per Item Ser Item No 95.00 here-in-before but of size 1000 ltrs capacity |
151 | All as per Item Ser Item No 95.00 here-in-before butbut of size 2000 ltrs capacity |
152 | S&F in replacement of20mm CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 grade with all types offittingssuch as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc as required at site, fittings on walls/ceiling or laying in floors complete all as specified and directed . |
153 | All as per Item Ser Item No 96.00 here-in-before but of25mm CPVC pipes |
154 | All as per Item Ser Item No 96.00 here-in-before but of40 mm CPVC pipes |
155 | All as per Item Ser Item No 96.00 here-in-before but of50 mm CPVC pipes |
156 | M&L for detecting leakage in GI Water Supply GI Lines of size20mm dia to 25 mm dia by necessary earthwork as required, tightening of lose joints of union ,elbow, socket nipple as per site, replacement of all fittings such as GI union, socket, nipple etc as required at site complete all asdirected. |
157 | All as per item No 97.00 above but Leakages in GILines of size40 to 50 mm bore complete all as specified and as directed |
158 | All as per item No 97.00 above but Leakages in GILines of size80 mm bore complete all as specified and as directed |
159 | S& F in replacement steel water tubesmedium grade (ISI marked) galvanised with all fittings and fixed to walls or laid on floor or in ceilings of size 20 mm bore pipe alongwith all fittings as per site reqirement including taking out of old pipelines complete all as specified and as directed by Engr-in-Charge. Make : Tata/Jindal/Bansal |
160 | All as per item No 98.00 above but of size 25 mm dia complete all as specified and as directed. |
161 | All as per item No 98.00 above but of size 40 mm dia complete all as specified and as directed. |
162 | All as per item No 98.00 above but of size 50 mm dia complete all as specified and as directed. |
163 | Supply and fix in replacement of GI tubing medium grade, 80mm bore ISI marked laid in floor / trenches etc fixing with all GI fittings as required at siteincluding taking out of old pipe complete all as specified and as directed by Engineer-in-Charge. |
164 | M&L in repair/rectification of leakages to water supply CPVC/UPVC lines of size20mm dia to 25 mm dia by necessary earthworkas required, tightening of lose joints of union ,elbow, socket nipple as per site, replacement of all fittings such as GI union ,socket, nipple etc as required complete all asdirected. |
165 | All as per item No 100.00 above but size 40 mm dia to 50 mm dia complete all as specified and as directed. |
166 | S & F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete after dismantling and taking out the existing unserviceable Gun metal gate valve of size 20 mm all as specified and as directed. Make : NMV, ZOLOTO, LEADER |
167 | All as per Item Ser Item No 101.00 here-in-before but of size 25 mm complete all as specified and as directed. |
168 | All as per Item Ser Item No 101.00 here-in-before but of size 40 mm complete all as specified and as directed. |
169 | All as per Item Ser Item No 101.00 here-in-before but of size 50 mm complete all as specified and as directed. |
170 | S&F in replacement for 20mm dia ball valves, Union Type, high pressure, CPVCpolythene gateand flynut complete all as specified and as directed. |
171 | All as per item No 102.00 but of size 25mm bore complete all as specified and as directed. |
172 | All as per item No 102.00 but of size 40mm bore complete all as specified and as directed. |
173 | All as per item No 102.00 but of size 50mm bore complete all as specified and as directed. |
174 | S&F in replacement of CPVC MTA of 20mm bore pipes of complete all as specified and directed |
175 | All as per item No 103.00 but of size 25mm bore |
176 | All as per item No 103.00 but of size 40mm bore |
177 | S&F in replacement of CPVC FTA of 20mm bore pipes of complete all as specified and directed |
178 | All as per item No 104.00 but of size 25mm bore |
179 | All as per item No 104.00 but of size 40mm bore |
180 | S&F in replacement of Submersible Pump set suitable for 415 volts, 3 phase, 56 M Head, 5 LPS at water bozer pointProthrapur including suitable automatic star delta starter complete all as specified and directed. |
181 | S&F in replacement sluice valve, cast iron body, stainless steel spindle, gun metal rings including wheelfor operation, flanged and drilled of size 100 mm dia, confirming to IS - 14846, class PN -1.6, long body type including all jointing materials, bolts, nuts, washer complete all as specified and as directed. |
182 | All as per Item Ser Item No 106.00 here-in-before but of size 80 mm dia complete all as specified and as directed. |
183 | M&L for construction of valve chamber of internal dimension 600mmx600mm x600mm suitable for sluice valve with PCC 1:3:6 type (C2) (using 40mm graded aggregate) for foundation, one hollow block masonry wall in cement mortar (1:4), 40mm thickPCC (1:2:4) type B1 (using 20mm graded aggregate) coping, rendering in CM 1:4, 15mm thick including provision of mild steel sheet cover of 3mm thick on 50x50x6 mm angle iron frame work emmbedded in concrete with suitable hinges and locking arrangements including two coats of black synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary excavation earth work on any type of soil etc, including demolition of old valve chambers complete all as specified and as directed. |
184 | All as per Item Ser No 107.00 here-in-before but of internal dimension 900 x 900x 900mm complete all as specified and as directed. |
185 | Dismantling of motor pump sets, removing electrical connections for servicing /rewinding /replacement of bearings etc, refixing the motor pumpset in original position including making proper allignment and necessary electrical connections, testing of the 05 HP capacity pump motor sets complete all as specified and as directed |
186 | M&L for taking out old burnt winding of stator and rotor, cleaning the slots and re-winding of motor with suitable gauge super enamelled copper winding wire, varnishing, insulation, ovening, greasing of 5 HP capacity motor including complete all as specified and as directed. Note : (a) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (b)The pumpset shall be spared for one week for repair from the date of complaint given by the department regarding breakdown. TheContractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (c)Please note that this penalty is exclusively other then the condition 56 of IAFW-2249 and shall be treated as interim condition of the contract. (d)The decision of the Accepting Officer in this regard shall be final and binding. If the same motor copper winding wiring burnt second time in the above CA Period, Thecontractor is responsible to paid and rewind the same at their own cost. |
187 | S&F in replacement water level indicator unit from Over head reservoir/Semi UG Sumpwith complete accessories such as copper ball, necessary pully, nylon rope, steel patti duly painted white with marking at every 10cm interval, letter writing of size 15mm width and 100mm long with signal red radium paint and painting of indicator with illumination postal red paint and errected at water tank as per site requirement with necessary angle, nut and bolts all as directed. |
188 | Excavation in trenches not exceeding 1.50m wide and n.exc 1.5m depth for foundation, laying of UG cables etc or for shafts, wells, cesspits, manholes, pier holes etc not excluding 10 Sqm on plan in hard/dense soil and getting out , complete all as specified and as directed. |
189 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed. |
190 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed. |
191 | Disconnecting and taking out old LT UG cable with aluminium conductor of any size/type from trenches/ walls/ poles/ pipes All as per directed and as specified. |
192 | Supply,laying,jointing,connecting,testing underground XLPE insulated,PVC seathed, armoured heavy duty electric LT cable,1100 volts grade with aluminium stranded conductor,10 sqmm 4core,laid in trenches/fixed to poles/drawn through pipes with suitable size cable glands,crimping type cable lugs,sockets etc.complete and taking down the existing cable all as specified and directed. |
193 | All as per item No 5 but cable of size 10 Sqmm 2 Core all as specified and as directed. |
194 | All as per item No 5 but cable of size 16 Sqmm 4 Core all as specified and as directed. |
195 | All as per item No 5 but cable of size 25 Sqmm 3.5 Core all as specified and as directed. |
196 | All as per item No 5 but cable of size 50 Sqmm 3.5 Core all as specified and as directed. |
197 | All as per item No 5 but cable of size 70 Sqmm 3.5 Core all as specified and as directed. |
198 | All as per item No 5 but cable of size 120 Sqmm 3.5 Core all as specified and as directed. |
199 | All as per item No 5 but cable of size 150 Sqmm 3.5 Core all as specified and as directed. |
200 | Supply and lay HDPE double wall corrugated pipes confirming to IS-14930 Part II for cable protection of size 110mm OD and 95mm ID including all acessories such as bend, end caps and couplers etc, complete all as specified and as directed. |
201 | All as per item No 116.00 but DWC Pipe 77mm OD and 63 mm IDall as specified and as directed. |
202 | All as per item No 116.00 but DWC Pipe 50 mm OD and 38 mm IDall as specified and as directed. |
203 | Relaying only serviceableLT UG Cable of any size and discription includingnecessary cable lugs complete all as specified and as directed. (All relevent items like excavation, earth work,etc shall be measured and paid seperatly) |
204 | Supply, laying and fixing in replacement 50mm bore GI pipe light grade for necessary road crossing, culverts etc for cable protection all as specified and as directed. |
205 | All as per item No 118.00 but pipe of size 80 mm all as specified and as directed. |
206 | M&L for PCC (1:3:6) type C2 using (40 mm graded aggregate in foundation, filing and mass concrete complete all as specified and directed. |
207 | Supply, replacing and fixing driver 230 v of street light suitable for 72/75W including taking down and refixng on pole all as specified and directed. |
208 | All as per item No 120.00 but driver 40/45Wall as specified and directed. |
209 | S&F in replacement outdoor type FRP junction box of size 300x200x105mm, light weight suitable for pole mounting using clamps/bolts and nuts including MCB SP 2.5 Amps single pole incl necessary two way connector for loop in loop out cable connectioncomplete all as specified and as directed. |
210 | All as per item No 121.00 but FRP junction box of size 140x140x105 mm complete all as specified and as directed. |
211 | M & L in repair for Earth continuity conductor or main earthing lead of20 x 3 mm copper strip, buried in ground or fixed to wallwith saddles and fixing screws etc complete all as specified and as directed. |
212 | S&F in replacement 75W LED flood light of Pressure aluminum die cast housing and powder coated, system wattage 75W,IP protection = IP 66, PF= 0.90 all as specified and directed. |
213 | M&L for painting on old surfaces LT panelby spray paint after cleaning strains and grease/oil spots with sand paper & thinner and painting the cleaned surface with synthetic enamel paint of existing colour to achieve good finish by applying two coats ofpaints by spray painting machine crefully after disconnection of power supply and covering the meters, indicators and switches to prevent from fall of paint drop on them All as per directed and as specified. |
214 | Supply and jointing as in repair straight through joint, outdoor type 1100 volts grade, heat shrinkable type suitable for 3.5 core, 95 Sqmm to 120 sqmm LT, XLPE cable and testing after jointing complete all as specified and as directed. |
215 | All as per item No 125.00 but joint of size 25 Sqmm to 50 sqmmcomplete all as specified and as directed. |
216 | All as per item No 125.00 but joint of size 10 Sqmm to 16 sqmmcomplete all as specified and as directed. |
217 | Supply, install and connection LT outdoor loop-in loop-out terminal box with sloping canopy of size 700x600x450mm made out of 3.15mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, front and rear hinged doors mounted on 25x25x4mm MS angle iron frame 60cms height, erected in ground with PCC foundation (1:4:8) type D-2 (using 40mm graded stone aggregate) including S&F in repair insulated aluminium bus bar of size 40x5 mm for 3 phase and neutralrespectively mounted on insulators and terminating with suitable cable with glands including taking down old terminal boxes complete all as specified and as directed. |
218 | M&L for repairing the existing LT Panel/ feeder Pillar Box any type or size by taking proper shutdown, disconnecting and reconnecting cables, welding/drilling for smooth funtioning of panel door, locking arrangement complete all as per directed and as specified. |
219 | S&F in replacement 3 phase multifunction meter type having accuracy class 1, range upto50-400 Amps with selectable CT secondary site 1A/5A complete all as per directed and as specified. |
220 | S&F in replacement indicating lamps LED type set (R,Y,B) complete all as per directed and as specified. |
221 | S & F in replacement selector switch complete all as per directed and as specified. |
222 | S &F in replacement CT Coil suitable 250/5A 440 volt system for different load complete all as per directed and as specified. |
223 | Supply only aluminium crimping type lugs of following sizes for maint of cable complete all as specified and as directed. (a)120 / 150 sqmm |
224 | (b)70/ 95 sqmm |
225 | (c)50 sqmm |
226 | (d)35 sqmm |
227 | (e)25 sqmm |
228 | (f) 16 sqmm |
229 | Material and Labour for preparation of oldsurfaces of 9 mtr high RCC Poles and applying one coat of cement based paint on RCC poles including painting black and yellow strips of 30 cm each on poles upto 1.0 m from the bottom and numbering with 60mm sized letter with synthetic enamel paint complete all as specified and as directed. |
230 | S&F in repair energy saving LED Garden light of 10 W LEDs made up of aluminium casting with acrylic diffuser for soft illumination effect and the bollard trunk is of black powder coated with silver white finish for tripod stand with the following specification complete all as specified and as directed |
231 | All as per item No 24 but LED Garden lightof 8W LEDs complete all as specified and as directed. |
232 | S&F in replacement energy saving LED Garden light of 10 W LEDs made up of aluminium casting with polycarbonate diffuser for soft illumination effect and the bollard trunk is of black powder coated complete all as specified and as directed. |
233 | S&F in replacement energy saving LED street light 45Wmatching the existing pattern of aluminium casting with polycarbonate diffuser for soft illumination effect and powder coated complete on existing GI pipe all as specified and as directed. |
234 | All as per item No 137 but LED street light 72/75Wall as specified and as directed. |
235 | S&F in replacement high mastFlood Light fitting 120Wenergy efficient and IP65 water proof with anti glare diffuser All as per directed and as specifjed. |
236 | S&F in replacement decorative Post top lantern 40 Watts with 360º indirect light, system wattage 40 W, Resistance to impact and corrosion, Glare free and better uniformity and making good disturbed surfaces all as specified and directed |
237 | Dismantling of old UNSV RCC poles 9 mtr long alongwith disconnecting LT cables, Street lights from site complete all as specified and directed. |
238 | Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130 mm bottom& 70 mm topmade up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. |
239 | S&F in replacement 40 mm bore, light grade, GI pipe bracket 1.0 mtr long, bend to shape including suitable size nuts, bolts and washers all as specified and as directed. |
240 | All as per item No 142.00 but GI bracket of size 32 mm bore all as specified and as directed. |
241 | S&F inreplacement analog timer switch programmable with 16A current carrying capacity suitable for mounting on DIN rail all as specified and as directed. |
242 | S&F inreplacement 4 pole contactor 255 A2 NO +2 NCall as specified and as directed. |
243 | All as per item No 144.00 but street light power contractor 40-50A all as specified and as directed. |
244 | Disconnecting the existing unserviceable MCCB frompanel board after disconnecting cable & supply & fix new MCCB 63A, 4 Pole, 16 KA,adjustable , fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble,nut bolt and washers etc complete. |
245 | All as per per item No 145 above but of 100A, 4 Pole, 16 KA All as per directed and as specified. |
246 | All as per per item No 145 above but of 100A, 3 Pole, 16 KA All as per directed and as specified. |
247 | Disconnecting the existing unserviceable MCCB frompanel board after disconnecting cable & Supply & fixing only MCCB 200A,25 KA 4 Pole fixed in existing panel including modification of existing frame and panel board door for proper installation of MCCB and connecting with existing cable including thimble,nut bolt and washers etc complete. |
248 | All as per per item No 146 above but of 250A, 4 Pole All as per directed and as specified. |
249 | All as per per item No 146 above but of 400A, 4 Pole All as per directed and as specified. |
250 | M&L for servicing and taking down high mast light fittings mechanically / manually for repair / maintenance and refixing in same position after repair / maintenance such as greasing, winch, motor servicing/ repair, starter repair etc & testing after service complete all as directed. |
251 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 M deep below ground level with top edge of the plate not less than 1.5 M below normal ground level connected to galvanised strip of 25x4 mm by means of nuts, bolts, checknuts, washers of galvanised iron or steel All as per shown in electrical plate No. 3 of SSR Part I of 2009 connected to earthing test pointor disconnecting / testing link including excavation/ earth work in any strata, removal of surplus earth, GI pipe medium grade 20 mm for watering and funnel, GI Pipe light grade 40mm dia for earth lead protection, PCC 1:3:6 type C1 chamber with chamber cover in RCC 1:2:4 type B1 and taking down of existing earthing |
252 | S&F in replacement 25 x 4 mm GI strip as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed. |
253 | Disconnection ofelectric connection of servo voltage stabiliser3 phase of cap 20 KVA air cooled type indoor type and segregating unsv parts replacing the same and re-installing the sameafter repair and servicing of serviceable parts to its original positionand making allconnections and testing on full load all as specified and directed.. Note:- Spares shall be measured and paid separately under respective items of schedule. |
254 | S&F microprocessor based electronic control card |
255 | S&F AC Synchronous motor |
256 | S&F Dimmer E Point |
257 | S&F IC Electronic Control Card |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail