Tender For Installation Of Distribution Transformers, Earthing, Plinth, Fencing, Line And Various Other Works Under The Business Plan 2024-25 Under Electricity Distribution Division-Iv (Mankapur), Gonda Area., gonda-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For Installation Of Distribution Transformers, Earthing, Plinth, Fencing, Line And Various Other Works Under The Business Plan 2024-25 Under Electricity Distribution Division-Iv (Mankapur), Gonda Area.. Submission Date for this Tender is 16-05-2024. Electrification Work Tenders in gonda Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43279089
Corrigendum : Tender For Installation Of Distribution Transformers, Earthing, Plinth, Fencing, Line And Various Other Works Under The Business Plan 2024-25 Under Electricity Distribution Division-Iv (Mankapur), Gonda Area.
Open Tender
Indian
Uttar Pradesh
gonda
16-05-2024

Tender Details

Tender For Installation Of Distribution Transformers, Earthing, Plinth, Fencing, Line And Various Other Works Under The Business Plan 2024-25 Under Electricity Distribution Division-Iv ( Mankapur ) , Gonda Area.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-May-2024 date extension Date 13-05-2024
2 14-May-2024 ddd ext Date 16-05-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 63600.0 /-
Tender Value
INR 63.52 Lakhs /-

BOQ Items

Name of Work:- ??????? ????? ????-??????(???????), ?????? ?????????????? ?????? ????? 2024-25 ?? ???????? ????? ?????????? ?? ???????, ???????, ??????, ???????, ???? ??? ???? ??????? ??????
Sl. No. Item Description
1All these below items/materials from S.N. 1.01 to 1.24 will be given and errected by the contractor on his own cost as per estimate/Resspo Norms.
2F BRACKET
3V typeX-ARM HOLDING CLAMP
4GAURDING X ARM HOLDING CLAMP
5T OFF DROPPER HOLDING CLAMP
6LT CLAMP for I HOOK
7TELLESSUNIT 500 Amp. With DB and Gate (4 CKT)
8L-PIECE COPPER
9I hook
10SUSPENSION CLAMP
11DEAD END CLAMP
12DB BOX 3 PHASE
13DB BOX CLAMP
14STAY CLAMP
15NUT and BOLT off size
16PEARSING CONNECTOR
17TRANSFORMER MOBLIE TROLLYWITH ALL FITTING as per estimate/resspo norms
18VACCUM INTRUPTER FOR STEL MEC
19CHARGING GEAR
20TRIPPING COIL
21CLOSING COIL
22AL LUGS (1X400 SQMM)
23JAW
24PG CLAMP
25Stone Pad
26Loading, Unloading and safe cartage of the following materials (S.N. 2.01 to 2.47) from Electricity Store Centre, Gonda to the work site/dump site (Distance up to 70 km)
27PCC POLE 8.5 MTR
28PCC POLE 9 MTR
29STP POLE 11 MTR
3025 KVA T/F
3163 KVA T/F
32100 KVA T/F
33250/400 KVA T/F
3411 KV V Type X-ARM
35MCCB
36RUBBUR MAT
37CJ KIT 3X70 O/D
38CJ KIT 3X185 O/D
39CJ KIT 3X185 I/D
40CJ KIT 3X300 I/D
41CJ KIT 3X300 O/D
42CONTROL CABLE 4X2.55 SQMM (IN MTR)
43CONTROL CABLE 2X2.5 SQMM (IN MTR)
4433 KV CONTROL PANAL
45BATTARY SET 24V
46BATTARY CHARGER 24V
47LIGHTING ARRESTOR
4833 KV CT
4933 KV VCB
50GARUDING X-ARM
51T OFF CHANNEL
52DROPPER ANGLE
53TOP CHANNEL
54SS BASS
5511 PIN INSULATOR
5611 DISK INSULATOR
57ACSR WEASEL CONDUCTOR
58LT XLPE Cable Al. 1X240 sq.mm
59LT XLPE Cable Al. 1X400 sq.mm
60LT XLPE Cable1X630 sq.mm
61XLPE Cable Al. 3X70 sq.mm
62XLPE 3X185
63XLPE 3X300
64ABC 1X25+1X16
65ABC 3X50
66ABC 3X95
67STAY SET
68GI WIRE 6 SWG
69STAY WIRE 7/10 SWG
70STAY INSULATOR
71EARTHING COMPLETE
72EARTHING ROAD
73Other Material
74Erection of single PCC/ST Poles (8.5/9/11 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site (All decentralize material shall be given by the contractor on his own cost.)
75Erection of sectional double pole sectional PCC/STP pole (8.5/9/11 mtr long) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. (All decentralize material shall be given by the contractor on his own cost.)
76Earthing with complete fitting
77Erection and Grouting of stay sets alongwith complete fittings. Cement, Sand & Brick ballast provided by the contractor at his own cost.
78Grouting of Poles with 1:4:8CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely.All required materials provided by the contractor at his own cost.
79Laying, stringing, sagging & binding of conductors of 11 KV in 3 phase, 3 wire line with jumpering (where as required)
80Construction of 11/0.4 KV S/S for following capacity of T/F with mounting and fitting of T/F on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of T/F fitting with all accessories.
8125 KVA T/F
8263 KVA T/F
83100 KVA T/F
84250/400 KVA T/F
85Laying, Stringing & Sagging of ABC Cable up to proper sag for the following size cable as per estimate/resspo norms
86ABC 1X25+1X16
87ABC 3X50
88ABC 3X95
89Laying Stringing sagging & Binding of All size XLPE cable wher is required as per estimate/Resspo norms.
90LT XLPE Cable Al. 1X240 sq.mm
91LT XLPE Cable Al. 1X400 sq.mm
92LT XLPE Cable1X630 sq.mm
93XLPE Cable Al. 3X70 sq.mm
94XLPE 3X185
95XLPE 3X300
96Installtion/Errection/Laying/stringing of the following items as per estimate/resspo norms.
97Diffent size Controll Cable
9833/11 KV different size Jointing kit
9933 KV CONTROL PANAL
100BATTARY SET 24V
101BATTARY CHARGER 24V
102LIGHTING ARRESTOR
10333 KV CT
10433 KV VCB
10511 PIN INSULATOR
10611 DISK INSULATOR
107TELLESSUNIT 500 Amp. With DB and Gate (4 CKT)
108DB BOX 3 PHASE WITH COMPLETE FITTING
109VACCUM INTRUPTER FOR STEL MEC
110CHARGING GEAR
111TRIPPING COIL
112CLOSING COIL
113AL LUGS (1X400 SQMM)
114JAW
115PG CLAMP
116MCCB
117RUBBUR MAT
118Gaurding of H.T./L.T. line with complete fittings as per estimate/resspo norms (All the decentralize material shall be given by the contractor)
119Boaring/Chemical type Pipe Earthing(with G.I. strip connection) as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
120Repairing of Plinth including dismounting/disconnection of T/F from system as well as mounting/reconnection to the system after repairing as per Estimate/Resspo Norms .(All the required materialshall be given by contractor on his own cost.)
121Wiremesh fencing with 1 door arrangement including grouting of footings and proper fxing as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
122CONSTRUCTION OF PLINTH WITH FENCING with gate as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
123Cutting of tree branches for cleaning route of 11 KV/LT line at the work site (25 mtr.= 1 Job)
124Carrage of scrap/conductor from site to store
125Dismentaling old material
126Dismentaling old line
127COSTRUCTION OF TRENCH OF SIZE 0.45X0.75 (IN MTR)
128Constructio of Structure/Plinth for VCB as per estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
129Construction of CT STRUCTURE AND PLINTHas per estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
130Consstruction of LA STRUCTURE AND PLINTHas per estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy