Tender For Work Related To Capacity Increase, Installation, Earthing, Protection And Power Lines Of Distribution Transformers Under The Regional Business Plan 2024-25., gonda-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For Work Related To Capacity Increase, Installation, Earthing, Protection And Power Lines Of Distribution Transformers Under The Regional Business Plan 2024-25.. Submission Date for this Tender is 13-05-2024. Electrification Work Tenders in gonda Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43279039
Corrigendum : Tender For Work Related To Capacity Increase, Installation, Earthing, Protection And Power Lines Of Distribution Transformers Under The Regional Business Plan 2024-25.
Open Tender
Indian
Uttar Pradesh
gonda
13-05-2024

Tender Details

Tender For Work Related To Capacity Increase, Installation, Earthing, Protection And Power Lines Of Distribution Transformers Under The Regional Business Plan 2024-25.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-May-2024 date extension Date 13-05-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 87900.0 /-
Tender Value
INR 87.85 Lakhs /-

BOQ Items

Name of Work:- ??????? ????? ????-?????, ?????? ?????????????? ?????? ????? 2024-25 ?? ???????? ????? ?????????? ?? ????????????, ???????, ???????, ?????????? ??? ??????? ?????? ?? ????????? ??????
Sl. No. Item Description
1All these below items/materials from S.N. 1.01 to 1.40 will be given and errected by the contractor on his own cost as per estimate/Resspo Norms.
2CLAMP FOR TOP, DROPPER AND T-OFF etc.
3LT Clamp
4LT SHACKLEINSULTER
5M.S. NUT & BOLT
6G.I. STRIP for Earthing
7V TYPE X-ARM HOLDING CLAMP
8Guarding Angle Holding Clamp
9EYE HOOK
10G.I. Pipe 6" Dia
1111 KV TPMO WITH COMPLETE FITTINGS
12CLAMP FOR DROPPER ANGLE
13DROPPER ANGLE (L/A)
14D.O. FUSE SET (WITH CHANNEL AND CLAMP)
15AL-LUG 95 SQMM
16BRASS NUT 12 MM
17BRASS NUT 20/30 MM
18DISTRIBUTION BOX MASSIONARY TYPE (FUSE SET COMPLETE)
19AL-LUG 400 SQMM
20AL-LUG 250 SQMM
21AL-LUG 630 SQMM
22AL-LUG 240 SQMM
23CONNECTOR FOR 630 KVA T/F
24CONNECTOR FOR 100 KVA T/F
25COPPER L - PIECE 62X250X12MM
26FIRE BUCKET WITH SAND
27FIRE BUCKET STAND
28RUBBER EARTH MAT
29Aluminium Paint
30Sand Paper
31Danger Board
32Name Plate
33Clamp for Danger Board & Name Plate
34Dead - end Clamp
35Pearsing Connector
36I Hook Holding Clamp
37Suspension Clamp
38F- Bracket
39Tyre for mobile trolly
40EARTHING COMPLETE FOR STRUCTURE
41Stone Pad
42Loading, Unloading and safe cartage of the following materials (S.N. 2.01 to 2.60) from Electricity Store Centre, Gonda to the work site/dump site (Distance up to 40 km)
43PCC Pole 8.5 METER
44ST POLE11 METER
4525 KVA T/F
4663 KVA T/F
47100 KVA T/F
48250 KVA T/F
49ABC CABLE 1×25sqmm
50ABC CABLE 3×50
51ABC CABLE 3×95
52ABC CABLE 3×120
53ACSR Weasel Conductor
54ACSR Dog Conductor
5511 KV XLPE CABLE 3 × 70
5611 KV XLPE CABLE 3 × 120
5711 KV XLPE CABLE 3 × 185
5811 KV XLPE CABLE 3 × 300
5911 KV XLPE CABLE AL. 1 × 400
6033 KV XLPE CABLE 3 × 120
61Controll Cable 2x2.5sqmm
62Controll Cable 4x2.5sqmm
6311 KV JOINTING KIT FOR 3 × 70
6411 KV JOINTING KIT FOR O/D 3 × 120
6511 KV JOINTING KIT FOR I/D 3 × 120
6611 KV JOINTING KIT I/D FOR 3 × 185
6711 KV JOINTING KIT O/D FOR 3 × 185
6811 KV JOINTING KIT I/D FOR 3 × 300
6911 KV JOINTING KIT O/D FOR 3 × 300
7033KV JOINTING KIT O/D FOR 3 × 120
7133KV3 × 120 Sqmm S/Th. Kit.
7211 KV V-Type X-Arm
7333 KV V-TYPE STEEL X-ARM
74TOP CHANNEL
7511 KV DROPER CHANNEL
7633 KV DROPER CHANNEL
77SUB STATION BASE
78T-OFF CHANNEL
7911 KV PIN INSULATER WITH PIN
8033 KV POLYMERIC PIN INSULATOR WITH PIN
8111 KV DISC INSULATER WITH FITTING
8233 KV POLYMERIC DISC INSULATOR 70 KM (B & S TYPE)
83EARTHING COMPLETE
84STAY SET COMPLETE
8524 VOLT BATARY
86BATARY CHARGER
87G.I. Wire 8 SWG
88Guarding Angle
89Distribution Box 1 Phase
9011 KV PT COMPLETE SET (11000/110V) FOR TOSHIBA MAKE VCB
9111 KV CT (200/100/5A) FOR TOSHIBA MAKE VCB)
9211 KV FUSE SET
9333 KV CT 400/200/1-1-1A
9433 KV Transformer Control Pannel For Single Feeder
9533 KV Transformer Control Pannel For double Feeder
9633 KV LIGHTING ARRESTOR
9733 KV Vacume Circuit Brakar 1250 Amp.
98LT PVC INSULATED CABLE 1X400 SQ.MM
99LT PVC INSULATED CABLE 1X630 SQ.MM
100LT PVC INSULATED CABLE 1X1000 SQ.MM
101LT PVC INSULATED CABLE 1X240SQMM
102Other material
103Erection of single PCC/ST Poles (8.5/11 Mtr Long) for 11 KV/L.T. line alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site (All decentralize material shall be given by the contractor on his own cost.)
104Erection of sectional double pole sectional PCC/STP pole (8.5/11 mtr long) alongwith fitting of all accessories on pole including dragging of pole from Dump Site to pit site. (All decentralize material shall be given by the contractor on his own cost.)
105Earthing of pole.
106Erection and Grouting of stay sets alongwith complete fittings. Cement, Sand & Brick ballast provided by the contractor at his own cost.
107Grouting of Poles with 1:4:8CC ratio of cement, sand & brick ballast, backfilling of pits with mud completely.All required materials provided by the contractor at his own cost.
108Laying, stringing, sagging & binding of conductors of 11 KV in 3 phase, 3 wire line with jumpering (where as required)
109Construction of 11/0.4 KV S/S for following capacity of T/F with mounting and fitting of T/F on plinth/double pole with proper fitting of all acessories and connecting with all circuit including earthing of T/F fitting with all accessories.
11025 KVA T/F
11163 KVA T/F
112100 KVA T/F
113250 KVA T/F
114Laying, Stringing & Sagging of ABC Cable up to proper sag for the following size cable as per estimate/resspo norms
115ABC CABLE 1×25sqmm
116ABC CABLE 3×50
117ABC CABLE 3×95
118ABC CABLE 3×120
119Laying Stringing sagging & Binding of All size XLPE cable where is required as per estimate/Resspo norms.
12011 KV XLPE CABLE 3 × 70
12111 KV XLPE CABLE 3 × 120
12211 KV XLPE CABLE 3 × 185
12311 KV XLPE CABLE 3 × 300
12411 KV XLPE CABLE AL. 1 × 400
12533 KV XLPE CABLE 3 × 120
126Installtion/Errection/Laying/stringing of the following items as per estimate/resspo norms.
127Diffent size Controll Cable 2x2.5sqmm
12833/11 KV different size Jointing kit
12933KV3 × 120 Sqmm S/Th. Kit.
13033/11 KV PIN INSULATER WITH PIN
13133/11 KV DISC INSULATER WITH FITTING
13211 KV PT COMPLETE SET (11000/110V) FOR TOSHIBA MAKE VCB
13311 KV CT (200/100/5A) FOR TOSHIBA MAKE VCB)
13433 KV CT 400/200/1-1-1A
13533 KV Transformer Control Pannel For Single/double Feeder
13633 KV Vacume Circuit Brakar 1250 Amp.
137Different size LT PVC INSULATED CABLE
138G.I. Pipe 6" Dia
139Installation of TPMO, D.O. fuse, Al-Lug, Brass Nut, DB box, L-Piece, Fire Bucket and stand, Rubber Mat, Danger Board, Name Place, type, Connector for T/F, Battry and charger, L.A. etc. and replacement of clamp /insulator/X-arm/CT/PT etc.
140Gaurding of H.T./L.T. line with complete fittings as per estimate/resspo norms (All the decentralize material shall be given by the contractor)
141Loading, Unloading and safe cartage of the following T/Fs from the work site/dump site to Electricity Store Centre, Gonda (Distance up to 40 km)
14210/16 KVA
14325 KVA
14463 KVA
145100 KVA
146EARTHING OF CT WITH G.I. EARTHING STRIPUpto water lavel as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
147Chemical Earthing of t/f (with G.I. strip connection) as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
148CHIMICAL EARTHING OF CT WITH G.I. EARTHING STRIP as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
149BORE TYPE DELTA EARTHING depth 40 feet for control room with GI strip as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
150BORE TYPE Pipe EARTHING depth 40 feet with GI strip as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
151Construction of Foundatin for VCB as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
152Construction of Foundatin for CT as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
153Construction of Foundatin forCONTROL PANNEL as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
154TRANSFORMER PLINTH REPAIRING as per Estimate/Resspo Norms.(All the required materialshall be given by contractor on his own cost.)
155Wiremesh fencing with 1 door arrangement including grouting of footings and proper fxing as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
156CONSTRUCTION OF PLINTH WITH FENCING as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
157Construction of Plinth for DISTRIBUTION BOX MASSIONARY TYPE (WITHFUSE SET COMPLETE) as per Estimate/Resspo Norms. (All the required materialshall be given by contractor on his own cost.)
158Interpolling in long span, resagging of loose conductor and replacement of damage X-Arm and F-Clamp and straightening of tilted pole providing stay set as required in HT line.
159Cutting of tree branches for cleaning route of 11 KV/LT line at the work site (25 mtr.= 1 Job)
160Carrage of scrap/conductor from site to store
161Dismentaling old material
162Dismentaling old line
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail