Tender For Provision Of Certain Special Repair Works Under Age Br Ii And Age Em Iv Under Ge ( South ) Bathinda At Bathinda Military Station, bathinda-Punjab

Military Engineer Services-MES has published Tender For Provision Of Certain Special Repair Works Under Age Br Ii And Age Em Iv Under Ge ( South ) Bathinda At Bathinda Military Station. Submission Date for this Tender is 22-05-2024. Civil Work Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43276282
Tender For Provision Of Certain Special Repair Works Under Age Br Ii And Age Em Iv Under Ge ( South ) Bathinda At Bathinda Military Station
Open Tender
Indian
Punjab
bathinda
22-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Provision Of Certain Special Repair Works Under Age Br Ii And Age Em Iv Under Ge ( South ) Bathinda At Bathinda Military Station

Key Value

Document Fees
INR 500 /-
EMD
INR 93000.0 /-
Tender Value
INR 46.52 Lakhs /-

Attachment

FileName File Description File Size
14666b0c-8728-4930-baec-80df6de686fc.html Tender Notice 0 KB
BOQ_729599.xls Tender Document 0 KB
TenderdocuGE05_I.pdf Tender Document 0 KB
TenderdocuGE05_II.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work :PROVISION OF CERTAIN SPECIAL REPAIR WORKSUNDER AGE B&R-II AND AGE E&M-IV UNDER GE (SOUTH) BATHINDA AT BATHINDA MILITARY STATION
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
2M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchincluding 10mm thick backing coat in CM 1:4 complete all as specified and directed.
3Material and Labour for joint free glazed ceramic coloured tiles of approved quality in vertical surfaces 450mmx300 mm x7mm/ 600mm x 300 x 7mm thick set jointed in neat cement slurry/paste and pointed in coloured cement to match with the tiles over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
4Taking down chowkhats or frame with shutter (without taking off shutters from the frames) not exceeding 1.5 Sqm each and removal from site complete all as specified and as directed.
5S & F Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
6S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. complete all as specified and directed
7S & F Aluminium anodised 100 mm long, Butt hinges type B-21 with galvanised mild steel screws complete all as specified and directed.
8S & FAluminium anodised barrel tower bolts, 150 mm long of extruded section complete all as specified and directed.
9S & F Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed.
10S & FPressed steel frames of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs hinges, locks strike plate etc, (thickness ofsheet shall be 1.25mm) complete all as specified and directed.
11M & L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for filling in back of pressed steel door frame/chowkhat and fixing of bed block of hold fast etc complete all as specified and as directed.
12M & L for 2nd class HW factory made Plain, framed, pannelled shutters 35 mm thick (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces.The size of rail and stile as per IS:1003 (Part I) Kiln seasoned and chemically pressure treated complete all as specified and directed.
13S & FButt hinges 100mm medium weight cold rolled mild steel and fixed complete all as specified and directed.
14S & F250 mm long mild steel sliding door bolt plate type stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on stapple plate and fixed complete all as specified and directed.
15S & F200 mm long mild steel barrel tower bolts, ISI market stove enamelled block with bright bolt and fixed complete all as specified and directed.
16S & F150mm long oval type mild steel pressed handles, ISI marked stove enamelled black complete all as specified and as directed.
17S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
18S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle 125mm (1 no.) complete all as specified
19S & F 4 mm thick figured glass, pin head type and glazing with oil putty in ventilator complete.
20S&F aluminium anodised barrel tower bolts of extruded section, 150 mm long (ISI marked) complete all as specified and as directed .
21Dismantling existing broken unserviceable PVC tank of capacity 1000 Ltrs complete all as specified and as directed .
22Supply and fixingthree layers 1000 litre HDPE water storage tanks polyproof. white in colour rotational moulded polyethylene (cylindrical vertical with closed top) hoisted and fixed in position including Supply and fixing of suitable size inlet/outlet arrangement & other accessories complete all as specified and directed.
23Supply and fixing in repairs ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of size 20mm bore ( weight 210 gms Minimum) complete all as specified and as directed.
24M&L in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including provision of lime concrete bedding complete all as specified and as directed .
25S&F in repair vitreous china wash down water closet pan (pedestal pattern) white with CI "P" or "S" trap inclwater closet seat cover of plastic,jet etc.complete incl necessary PVC waste pipe fitting, complete all as specified and as directed .
26S&F in repairs Vitreous China valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets suitable for IWC/ EWC complete all as specified and as directed .
27S&F in repairs Counter Wash basins, Vitreous China (oval type) size 560X 410 mm, including 32 mm Chromium plated waste coupling of fixing of supply and waste pipe/bottle trap including making connections and fixed in position complete all as specified and as directed .
28S&Fin repair 15 mmSwan neck fency type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed .
29S&F in repairs Vitreous China Urinal, Half stall type, white including 40mm waste coupling including making connections and fixed in position complete all as specified and as directed .
30S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed .
31S&F in repairs Vitreous china urinal partition white of size 310x700 mm terminating about 40cm above floor line, fixedcomplete all as specified and as directed .
32S&F in repair 15mmBib taps, cast copper alloy chromium plated fency type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed .
33S&F in repairs 15mm angle stop valves,fency type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed .
34S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed .
35S&F in repair brass chromium plated shower rose 100 mm of size with arme and with or without swivel joints to steel pipe or union complete all as specified and as directed .
36S & F in repairs 15 mm dia CP brass stop valves cast copper alloy (concealed type) complete all as specified and as directed .
37Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removing rubbish from the site complete all as specified and as directed .
38Water proofing treatment to sunken slab and adjoining vertical surfaces as specified under:- (a) M&L rendering 10 mm thick in cement plaster (1:3) using coarse sand mixed with integral water proofing compound as per manufacturer"s instruction trowel even and smooth with steel trowel on sunken surfaces (Note : WPC shall be measured and paid separately) (b) Applying first coat of chemical pidifin 2K(Dr Fixit) on cleared RCC surfaces @ 0.86 Kg/Sqm (Minimum) as recommended by manufacturer. (c) Provide a layer glass fibre mesh of size 2.25mm x2.25mm (45 GSM) over first coat of chemical Pidifin 2K as per manufacturers recommendation. (d) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) layer glass fibre mesh of size 2.25mm x 2.25mm (45 GSM) as recommended by manufacturers.
39Supply only liquid water proofing compound ISI marked confirming to IS 2645 - 2003 complete all as specified and as directed .
40PCC 1:5:10, type E-2 as in filling of sunken floors etc. complete all as specified and directed.
41Dismantling of brick tiles or tertacing tiles single layer on roof & disposal of retrieved material up to distance n.exc 100m where directed, complete all as specified and as directed .
42Dismantling of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof disposal off rubbish upto a distance n.exc 100m where directed) complete all as specified and as directed .
43M&L screed bed or bedding layer of mortar 1:4 of 15mm thick as on roof surfaces parapet or vertical beam surface (horizental or vertical) of finish even and smooth witout using extra cement complete all as specified and as directed . Note using only course sand (Toka sand) in screed bed/plastering.
44Preparation ofRoof / wall concrete/plastered surfaces & applied a coat of cold bituminous primer over cleaned surface @ 0.40 Kg/Sam followed by APP modified five layer polymeric membrane 3mm thick, minimum wt 3.50 Kg/Sqm reinforced with polyester non-woven fabric (weighing not less than 150 gms/Sam) manufactured by M/S STP Ltd/IWL India Ltd or its equivalent, laid as per the manufacturers instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces if required complete all as specified and directed.
45Cement concrete tiles 25cm x 25cm x 20 to 22 mm thick, m a c h i n e pressed; set jointed and pointed in neat cement slurry over and including 15mm thick screed in CM (1:4) with and including mixing of liquid water proofing compound as per manufacture specifications, as in roof and floor tiles complete all as specified and directed.
46Making benching with PCC (1:2:4) type B0 using WPC as per manufacturer"s instruction along side wall adjoining to roof in concave shape complete all as specified and directed. Note : WPC shall be measured and paid separately.
47Taking down or up 15 mm bore galvanised iron tubing/PL-AL-PE pipesand connection including cleaning for refixing or removal complete all as specified and directed.
48Taking down or up 20 mm bore galvanised iron tubing /PE-AL-PE pipes and connection including cleaning for refixing or removal complete all as specified and directed.
49Supply and fixing GI tubing medium grade with all fittings and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm complete all as specified and directed .
50Supply and fixing GI tubing medium grade with all fittings and fixed to walls & ceilings or laid in floors, bore of pipe 20 mm complete all as specified and directed .
51Taking down AC eaves gutters and rainwater pipes (any size and pattern), including all fittings, heads, shoes, bends, swan-necks, etc complete all as specified and as directed by Engineer-in-Charge.
52Supply and fixing 110 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joint fixed to walls with MS clampscomplete all as specified and directed.
53S & F 110 mm bore, PVC (SWR) fittings such as bends, tee,shoe etc;fixed to PVC pipes, complete all as specified and directed.
54Supply and fixing in repair cast iron floor trap, 75mm dia with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregateincluding CP gratting of suitable sizecomplete all as specified and directed.
55Dismentalling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall , laid in trenches incl all fittings and accessories
56Dismentalling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall , laid in trenches incl all fittings and accessories
57S & F100 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches complete all as specified and as directed .
58S & F75 mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to walls with and including suitable size clamps / laid in trenches complete all as specified and as directed .
59S & F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and as directed .
60S & F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door complete all as specified and as directed .
61S&F 100 mm in repairs CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed .
62S&F 75 mm in repairs CI Branch pieces, double(equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed .
63S&F in repair CI Cowl 100 mm complete all as specified and as directed .
64S&F in repair CI Cowl 75 mm complete all as specified and as directed .
65S&F 100 mm in repairs CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed .
66S&F 75 mm in repairs CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and as directed .
67Dismantling of Stone slabs and tiles laid, bedded and pointed in any type of mortar of any description or thickness in floors, aprons etc complete all as specified and as directed .
68S & F 20 mm thick granite slabs for wash hand basin over 15 mm thick screed bed in CM 1:6 including moulding and nosing of corners/ edges complete all as specified and directed,
69Material and Labour for providing precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in cooking plateform/slab including necessary formwork and setting in mortar set in cement mortar (1:4) complete all as specified and as directed.
70M&L for TMT bars 10 mm dia and over cut to length and bent to shape required including cranking, hooking ends and binding with and MS wire not less than 0.9 mm dia or securing with clips complete all as specified and as directed .
71S & Fin repair Steel work in tubular/rectangular MS Pipe such as vertical post,trusses, rafter, purlins etc. including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1998 grade St-240complete all as specified and as directed .
72S&Fin repair Plates (Plain or chequered) channels,squarecut or notched (ordinary and counter sunk) forming holes, w/o any attachment conforming to FE-410-W( Gde-E-250 )quality -A complete all as specified and as directed .
73S&F in repair for joist,channel, angles or tees with web and flanges cut to shape drilled and counter sunk for screw, including bending and welding angles as necessary, gusset plates, riveting etc. n.exc 10 kg each brackets conforming to FE-290 Gde-E-165 ) complete all as specified and as directed .
74S&F Pre paintedgalvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
75S & F bevelled edge mirror 5 mm thick selected quality glass mounted on walls fixed to chromium plated brass screws and cup washers complete all as specified and directed.
76Demolition of brick work built in cement mortar including all quions, arches , pillars etc. complete all as specified and as directed .
77M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built inCM 1:6 complete all as specified and as directed .
78M/L forhalf brick work with sub-class "B" bricks, straight or curved on plan exc 6m mean radius built in In cement mortar 1:4 complete all as specified and as directed .
79Taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish from the premises to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified and as directed .
80M&L for rendering 15 mm thick in cement mortar (1:6) on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and as directed .
81M&L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces even and fairwithout using extra cementcomplete all as specified and as directed .
82M&L for rendering 10 mm thick in cement mortar (1:3) on external wall surfaces of brick work or concrete surfaces even and fairwithout using extra cementcomplete all as specified and as directed .
83M&L for prepration of new plastered surface and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth including two coat ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification.
84M&L for complete removal of existing treatment on old plastered surface andapplying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth including two coat ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification.
85M&L Preparation of new plastered surfaces of walls and applying two coat of cement base paint on walls including cornices etc complete all as specified and directed.
86M&L for prepration of new plastered surface andFinishing walls with two coat ofAcrylic Smooth exterior paint of required shade : ( applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed
87M&L for Complete removal of existing treatment of any description on old wall surfacesplastered or unplastered surfaces of walls and applying two coat of cement base paint on walls including cornices etc complete all as specified and directed.
88M&L for complete removal of existing treatment on old plastered surface and Finishing walls with two coat ofAcrylic Smooth exterior paint of required shade : ( applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed
89M&L for preparing new surfaces of ceiling and applying two coat of white wash etc complete all as specified and as directed .
90M&L Preparation of old plastered or unplastered old decorated surfaces of ceiling by brooming for down or steel wire brushing, scrapping down make spots, treating oily/greasy spots, mass and efflorescence and applying one coat of white wash on ceiling including cornices etc complete all as specified and directed.
91M&L prepration of new wooden Surfaces of any description, over 10cm in width or girth,not otherwise described an applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed .
92Demolition of RCC of any descrition such as Kitchen chimniy, chajja, shelves, OHT Tanks,Pilar,wall, column.beam etc and in any position not other wise specially provided for complete all as specified and as directed . (reinforcement cut as required to facilitate demolition)
93M&L prepration of new steel Surfaces of any description, over 10cm in width or girth,not otherwise described an applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and as directed .
94Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed .
95M&L for Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed .
96M&L Cement concrete Type C2 , 1:3:6 in foundations, filling and mass concrete(40 mm gradedaggregate) complete all as specified and as directed .
97M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
98M&L Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade Fixed with grey cement and pigment complete all as specified and as directed .
99Taking down old cement plaster including raking out joints hacking for key scrubbing down with water and any type of textile covering/ terfelt if any of any description etc and removing rubbish from the premises to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified and as directed .
100S&F 0.71 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and as directed .
101Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed .
102M&L for 75 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) finishing surface even and smooth without using extra cement complete all as specified and directed
103M&L 38 mm wide Glass dividing strips, 3 mm thick and ditto
104Carefully chipping, removing existing loose/ damaged concrete with plaster from Roof, Ceiling, Chajja, Fascia, Fins, Drops, beam, column and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operateddiamond concrete saw blade, making the edges straight and even and cleaning it by wire brush and then by air blowercomplete all as specified and as directed .
105Cleaning all existing reinforcement bars inRoof, Ceiling, Chajja, Fascia, Fins, Drops, beam, column and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturer’s instructions,complete all as specified and as directed . Note :- Mode of measurement : per sqm of breaking area of concrete only.
106Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturer"s instructions but min0.4 kg/Sqm approx) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and as directed . Note :- Mode of measurement: per sqm of application area of concrete.
107Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and as directed .
108Supply and fixing 10mm dia and above additional corrosion resistant hot dip galvanised steel rebar Fe 500D or high grade as per required diameter in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and as directed .
109Supply and fixing6mm to 8mm dia additional corrosion resistant hot dip galvanised steel rebar Fe 500D or high grade as per required diameter in various structural elements such as columns, beams, and slabs etc. to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and as directed .
110Providing and filling ready mix Polymer Modified Mortar (PMM) in grooves of any depth in Roof, Ceiling, Chajja, Fascia, Fins, Drops, Columns, Beams and similar items in layers upto required thickness to reach the surface level, not exceeding 20 mm at a time, complete all as per specified and as directed. PMM shall havecompressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and as directed .
111Rebuilding the section of damaged RCC elements to its original size in thickness upto 100mm by supply and casting with ready to use non shrink, cementitious free flow micro-concrete having compressive strength > 60 N/sqmm (28 days) according to ASTM C 1107-99, including mixing, placing andleveling the surface by grinding off cementitious slurry or cementitious joints differences if any and curing complete all as specified and as directed . Note :- Mode of measurement: per KG of micro concrete.
112M&L prepration of old steel Surfaces of any description, over 10cm in width or girth,not otherwise described an applying one coat of synthetic enamel paint complete all as specified and as directed .
113Preparing of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing, scraping down smoke soot, moulds, mass and efflorescence, salt and trading oil and greasy spouts and applying Two coat of white wash on walls including cornices etc complete all as specified and directed
114M&L for Preparing new surfaces of walls and applying three coats of Whitewashing on Walls complete all as specified and as directed .
115INTERNAL ELECTRIFICATION
116Taking down carefully to existing serviceable copper point wiring (light,fan, socket or power) complete includingfittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removing materials to E/M store for keeping in safe custody and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
117M & L forPoint wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: -
118One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed.
119One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed.
120One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor,in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed.
121One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor,in and including rigid non metallic PVC medium duty concealed conduitcomplete all as specified and directed.
122One socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor,complete all as specified and dir
123Note for serial item No 117 to 122: 1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule "A". 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed.
124S&F Switch modular type single pole, one way, 6 Amp, one modulecomplete all as specified and directed.
125S&F Switch modular type single pole one way, 16 Amp, one module complete all as specified and directed.
126S&F Socket outlet modular type, multipurpose, 3 pin, single pole one way, 6 Amp,two module, shutter type complete all as specified and directed.
127S&F Socket outlet modular type multipurpose 2/3 pin single pole one way 6/16 Amp, two module, shutter typecomplete all as specified and directed.
128S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
129S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m3000/6500K, efficacy not less than 90 lumen/watt, extruded Aluminium/ polycarbonate, PC diffusor and integrated inbuilt driver completecomplete complete all as specified and directed.
130S&F MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified and directed.
131S&F MCB 32-40 Amp 240V SP 10 KA ‘C’ series complete all as specified and directed.
132S&F RCBO for EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION 415 V 40-63A AC type 10kA Four pole 30mA ISI marked complete all as specified and directed.
133S & F in replacement sub main two single core PVC copper conductor unsheathed wire multi standed 6.0sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, bend etc and including 6.0sqmm sopper conductor single core wire connected by common earthincluding 20mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed.(Note:- Two lengths of 6.0sqmm cable and one lenth of 6.0sqmm earth cable along with 20mm dia concealed PVC conduit, medium grade, ISI marked will be measured as one running length)
134Supplying and fixing wall mounted LED batten fitting complete with one LED tubelight 1x10 watt, 6500K, 2 ft complete with decorative LED lighting fixture with extruded polycarbonate enviroment frindly, energy efficient complete with all light fittings connection complete all as specified and directed.
135Dismentaling and taking down carefully MCB distribution boxes including MCBs/isolators of any type and modelcomplete all as specified and directed.
136Supplying and fixing angle lamp holder polycarbonate type with back plate complete all as specified and directed.
137Supplying and fixing LED 7W lamp base B-22complete all as specified and directed.
138Supplying and fixing sheet metal encloser double door 8 way SPN 230V ISI marked IP 43 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet factory madecomplete all as specified and directed.
139-do- all as per item No. 138 Above but 04 way TPN 415Vcomplete all as specified and directed.
140Supplying and fixing wall mounted LED batten fitting complete with one LED tubelight 1x20 watt, 6000K, 4 ft complete with decorative LED lighting fixture with extruded polycarbonate enviroment frindly, energy efficient complete with all light fittings connection complete all as specified and directed.
141S & F LED light fitting 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
142Dismentaling of unservicable earthing complete all as specified and directed.
143M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burriedin ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick eachconnected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates)for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I andtesting on completion including replacement of old unserviceable.
144S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 & IK 08 protection including fixing with suitable bolt and nuts complete with making connection complete all as specified and directed.
145Note:- Net contract sum shall be calculated after deduction of Sch of credit.