Tender For Repair And Maintenance Of Summer Appliances Under Ge (West) Jrc, jalandhar-Punjab

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances Under Ge (West) Jrc. Submission Date for this Tender is 20-05-2024. AMC of Air Condition Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43269317
Corrigendum : Tender For Repair And Maintenance Of Summer Appliances Under Ge (West) Jrc
Open Tender
Indian
Punjab
jalandhar
20-05-2024

Tender Details

Repair And Maintenance Of Summer Appliances Under Ge ( West ) Jrc

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-May-2024 CORRIGENDUM NO 01 BOQ 13-05-2024
2 13-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 44000.0 /-
Tender Value
INR 22 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF SUMMER APPLIANCES UNDER GE (WEST) JRC
Sl. No. Item Description
1Maintenance, servicing and testing of split type/window type AC, capacity 1.5 ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge. Note - Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc, transportation of equipment to workshop and back is deemed to be inclusive in the unit rates quoted by the contractor.
2WINDOW/SPLITTYPE AIR CONDITIONER Supply & fixing in replacement, new compressor for window/ splittype AC 1.5 Ton capacity including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system(Compressor should be company sealed and brand new suitable for gas R-410) complete all as specified and directed. Make: Shriram /Kirloskar / Voltas / Carrier / Whirlpool Note: Compressor shall be tested to entire satisfaction of Engr-in-Charge and test results recorded and kept on charge.
3All as per Srl Item No 2.00 here-in-before but 2.0 Ton capacity complete all as specified and directed.
4Material and labour for trickle charging of gas as required in AC of capacity 1.5 ton, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all as specified and directed.
5All as per Srl Item No 4.00 here-in-before but 2.0 Ton capacity complete all as specified and directed.
6Supply & fixing nylon type filter pad20 micron for window type AC of capacity up to 2 ton including taking out unserviceable filter pad complete all as specified and directed.
7Supply & fixing, in replacement, running capacitor 5 MFD 230 volts for blower motor complete all as specified and directed. Make : Keil / Asian /Tesla.
8All as per Srl Item No 7.00 here-in-before but 36 - 40 MFD complete all as specified and directed.
9All as per Srl Item No 7.00 here-in-before but 45 - 50 MFD complete all as specified and directed.
10All as per Srl Item No 7.00 here-in-before but 45+5 MFD complete all as specified and directed.
11All as per Srl Item No 7.00 here-in-before but 50+5 MFD complete all as specified and directed.
12Supply & fixing, in replacement, starting capacitor 80-100 MFD 230 volts complete all as specified and directed. Make : Keil / Asian /Tesla.
13All as per Srl Item No 12.00 here-in-before but 110-120 MFD complete all as specified and directed.
14Supply & fixing in replacement, single pole & Neutral sheet metal enclosure with 2 pin plug top and earth plug socket complete with MCB SPN 20 Amps, 240 Volts Complete all as specified and directed by Engr-in-Charge
15Supply & fixing in repalcement starting relay suitable for window type AC of capacity up to 2 ton compete all as specified and directed. Make : Shriram /Renutrol.
16Supply & fixing in replacement, thermostat switch of working temp 6 degree to 20 degree suitable for window type AC or split type of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol.
17Supply & fixing in replacement, blower motor 1/8 HP, double shaft, single phase suitable for window type AC up to 2 ton capacity including testing complete all as specified and directed. Make: Khaitan or Universal.
18Supply & fixing in replacement, fan blade for blower motor for window type AC up to 2 ton capacity complete all as specified and directed. Make: Whirpool or LG
19Supply & fixing in replacement, front grill for window type AC up to 2 ton capacity complete all as specified and directed. Make: Blue Star/Usha/General.
20Supply & fixing, in replacement, starting relay suitable for split type AC of capacity up to 2 ton complete all as specified and directed. Make : Shriram/Renutrol
21Supply & fixing in replacement single phase connector for split type AC upto 2.0 Ton capacity complete all as specified and directed. Make : Shriram
22Supply & fixing in replacement, blower motor 1/8 HP, singleshaft, single phase suitable for split type AC up to 2 ton capacity including testing complete all as specified and directed. Make: Whirpool or LG
23Supply & fixing in replacement, front grill for split type AC up to 2 ton capacity complete all as specified and directed. Make: Blue Star/Usha/General.
24Supply & fixing PVC copper conductor cable of size 4 Sqmm 3 core PVC sheathled compete all as specified and directed.
25Supply & fixing 4 way reverse valve of make: “RENCO” ISI marked in split/window type AC including replacement of heating and cooling thermostat Make “PECIFIC” and two way heavy duty toggle switch make “GEC/SSK/KAY” with and including recharging the system withgas R22 or as required after fixing of four way reverse valve with remote control and sensor platefor heating and cooling system and testing complete all as specified and directed by Engr-in-charge.
26Supply & fixing in replacement, internal unit completefor split type AC 1.5 Ton capacity, comprising of blower motor, fan blade with rotor, evaporator with suitable filter, remote control system along with outer shell complete all as specified and directed. Make: Blue star/LG.
27All as per Srl Item No 26.00 here-in-before but 2.0 Ton capacity complete all as specified and directed.
28Supply & fixing in replacement, external unit compressorfor split type AC 1.5 Ton capacity, comprising of condenser oil, blower motor, blower fan, copper valve ½” & 5/8” with hot and cold arrangement complete all as specified and directed.
29All as per Srl Item No 28.00 here-in-before but 2.0 Ton capacity complete all as specified and directed.
30Supply & fixing in replacement, suction and discharge pipe line of 1st quality copper, size ½” and 3/8” or 5/8” duly insulated along with 4 Sqmm 3 core flexible copper cable PVC sheathed complete all as specified and directed.
31Supply & fixing in replacement, MS factory made stand powder coated (as per sample) including zebra bolts & washers complete all as specified and directed.
32Supply & fixing in replacement, PCB kit for split/window type AC including modification for hot and cold, if required complete all as specified and directed by Engr-in-charge. Make : LG/Voltas/Blue Star/Sidhwal/ Carrier
33Attending complaints and rectification of defects of any type AC, Refrigerator, Water Cooler, Deep Freezer,Voltage Stabilizer etc and testing after complete all as specified and directed. Note :- (i) The complaint shall be notified to the contractor by Engr-in-Charge or JE E/M and recorded in the register maintained for the purpose. (ii) Cost of any minor nature of repair, replacement of petty items such as nuts, bolts, washers, screws, piece of electric cable upto 0.50 metre length etc is deemed included in the unit rate quoted by the contractor.
34DEEP FREEZER/REFREGIRATOR AND WATER COOLER Supply, fixing & testing new compressor for water cooler of capacity 40/80 Ltr, deep freezer capacity 200 to 500 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make: Denfoss or Whirlpool
35All as per Srl Item No 34.00 here-in-before but water cooler capacity 60/120 Ltr and 150/150 Ltr.
36Supply & fixing, in replacement blower motor 1/35 HPwith base and clamp, rubber mountings for water coolers including taking out the old unserviceable motor complete all as specified and directed. Make: Universal/Crompton Greaves/Cool king/ American Universal
37Material and labour for trickle charging of gas R-134 (a) or as required in water cooler, deep freezer any capacity, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all specified.
38Supply & fixing push type water tap, 15 mm dia, chromium plated suitable for water cooler complete all as specified anddirected.
39Supply & fixing, in replacement, thermostat switch suitable for water cooler, any capacity/make including taking down unserviceable thermostat switch complete all as specified and directed. Make: SHRIRAM or RANUTROLL or INDOFOSS.
40Supply, fixing & testing new compressor for refrigerator of capacity 230 to 310 Ltr including disconnecting, opening up, taking out burnt compressor by cutting/opening the pipe connections, fixing in position, reassembling, testing and commissioning including gas & oil charging after ensuring entire system leak proof complete all as specified and directed. Make : Kirloskar/Shriram
41Material and labour for trickle charging of gas R-134 (a) or as required in refrigerator of capacity 230 to 310 Ltr, after detection of leakage with soap solution/halide torch ,making the system leak proof by brazing/ soldering the leakage point, flushing out the moisture contentstrapped in the pipe line by charging CO2 gasand maintaining the pressure forprescribed period complete all specified.
42Supply & fixing in replacement freezerassembly suitable for refrigerators of any make, 230 to 310 litres capacity including taking out unserviceable assembly complete all as specified and directed. Make :Kelvinator / Zenith / Godrej/ Whirlpool /Voltas
43Supply & fixing, in replacement starting relay ISI marked for refrigerator of different capacity/make including taking out unserviceable relaycomplete all as specified anddirected.
44Supply & fixing, in replacement thermostat switch for refrigerator of different capacity/make including taking out old unserviceable thermostat switch complete all as specified anddirected. MAKE: SHRIRAM orRENUTROL or INDOFOSS.
45Supply & fixing, in replacement capillary tube made of copper, any size suitable for Refrigerator/Water Cooler including taking out old unserviceable capillary tube complete all as specified anddirected.
46Supply & fixing, in replacement capillary filter drier 2 way suitable for water cooler including taking out old unserviceable capillary filter complete all as specified anddirected.
47Supply & fixing, in replacement capacitor for refrigerator of different capacity/make including taking out old unserviceable capacitor switch complete all as specified anddirected.
48Supply & fixing in repairs AC auto manual Voltage Stablizer of capacity 5 KVA with input Volt 125 - 280 Volts and output Volts 200-240 Volts, +2% variation, comprising of voltmeter, fuse unit socket, connected lead etc. with time delay system complete all as specified and directed Make : Venus/AE/Vintec (Volina)/Brentford/Whirlpool/V-Guard or as approved by GE.
49Supply & fixing in repairs AC auto manual Voltage Stablizer of capacity 4 KVA with input Volt 125 - 280 Volts and output Volts 200-240 Volts, +2% variation, comprising of voltmeter, fuse unit socket, connected lead etc. with time delay system complete all as specified and directed Make : Venus/AE/Vintec (Volina)/Brentford/Whirlpool/V-Guard or as approved by GE.
50Supply & fixing PVC copper conductorcable of size 2.5 Sqmm 3 Core PVC sheathled compete all as specified and directed.
51Supply & fixing in repair, door rubber gasket with magnetic strip for refrigrator of capacity upto 310 litres of any size make complete all as specified and directed by Engineer-in-Charge.
52Supply & fixing in repairs, open type relay for refrigrator of any make of capacity upto 310 litres ccomplete all as specified and directed by the Engr-in-charge.
53Supply & fixing in repairs, PVC high density crisper (vegetable & fruit tray with crisper glass) suitable for any type refrigerator upto 310 litres complete all as specified and directed by Engr-in-charge.
54Supply & fixing water cooler trey siutable for 40/80, 60/120,150/150 ltr including waste water outlet pipe complete all as specified and directed.
55Supply & fixing thermal overload protector of working capacity 90/230 Watt suitable for refrigerator 230/310 ltr complete all as specified and directed.
56Supply & fixing copper condensor coil suitable for window/split type AC complete all as specified and directed.
57Material and labour for shifting of AC of any type and size complete all as specified and directed by Engr-in-Charge.
58Supply & fixing in repair insulation cover of black colour for copper pipe of AC of any size complete all as specified and directed.
59Supply & fixing PVC flexible drain pipe for AC water outlet of size 20mm including all fittings complete all as specified and directed.
60Supply & fixing MCB single pole 20/32 Amp, 50 Hz complete all as specified and directed.
61Supply & fixing swing motor for split type AC of capacity 1.5 or 2 ton complete all as specified and directed.
62DESERT COOLER AND STABLIZER Repair, servicing & overhauling of desert cooler, any size/type/make including greasing, oiling of fan motor and vertical Pump (Tulu Pump) decarbonising the electric connections, reconnecting cable connection by providing newthimbles, duly PVC insulated the joints and including providing set (Set of 3 Nos) of new cooler pad made of wood wool pad of size as per requirement complete all as specified and directed.
63Supply & fixing, in replacement, blower motor copper wind 200 watt, 1/8 HP,single phase suitable for desert cooler including testing complete all as specified and directed. Make: Khaitan/Universal/Pilot.
64Supply & fixing vertical pump (Fish type) for desert cooler, single phase 230 Volts including taking out unserviceable vertical pump complete all as specified anddirected. Make : Khaitan/Universal/Pilot.
65Supply & fixing PVC distributor, size 15mm for desert coolers including taking out unserviceable distributor complete all as specified and directed.
66Supply & fixing PVC Elbow, size 15mm for desert cooler including taking out unserviceable elbow complete all as specified and directed.
67Supply & fixing selector switch three speed (low, medium and high) suitable for desert coolers including taking out unserviceable selector switch complete all as specified and directed.
68Supply & fixing PVC pipe 15mm dia suitable for desert coolers including taking out unserviceable PVC pipe complete all as specified and directed.
69Supply & fixing cooler pad made of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed.
70Supply & fixing PVC front grill for desert coolers of any type/size including taking out unserviceable grill complete all as specified and directed.
71Supply & fixing starting capacitor 4 MFD 230 volts including taking out unserviceable capacitor, including testing complete all as specified and directed. Make : Keil / Asian /Tesla.
72Supply & fixing metal/pvc fan blade for desert cooler of any capacity complete all as specified and directed.
73Supply and fabrication of suitable size Galvanised stainless steelducting incl fixing with necessary hangers and support, hanging of duct complete incl taking down old unserviceable duct all as specified and directed.
74Supply and fabrication for duct thermal insulation with 6mm thick nitrile insulation with help of adhesive complete all as specified and directed.
75Attending breakdown(except periodical maintenace) by skilled Ref Mechanic from OEM/authorised dealer for any type AC plant/cold store of capacity 5 TR to 37.5 TR, diagonising the fault, repair/replacement of unserviceable parts including carrying out minor repairs such as changing of small pieces of wires, tightening of loosen electric connections ,nuts, bolts screws, or switches, disconnecting andrefixing of LT cables etc as required to make the system functional in any time by deploying sufficient technician alongwith with helper incl necessay T & P complete all as specified and directed. Note: (a) Replacement of major items shall be measured and paid for separately under respective items.b) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly. (c) Breakdown comlplaintsshall be collectedfrom complaint cell or by telephonically from duty staff/JE E/M/Engr-in-Charge.(d) In case of failure on the part of contractor for attending any breakdown within 4 hours a penalty shall be imposed @ Rs.2000/- per complaints and recovered from his dues.
76Taking down the old discharge/suction/oil pressure sensor and Supply and fix new discharge pressure sensor testing and commissioning 0-5 PSI 37.5 TR compresor.
77M&L for disconnecting electric motor 7.5HPand transporting to workshop, dismantling the same and taking out rotor assembly removing burnt winding coil of stator, cleaning the complete stator and rotor with carbon tetra chloride solution, rewinding the stator coil with super enameled copper conductor of proper size/gauge as per existing, inserting the new re-winded coils of stator dulyvarnishing and insulated with superior quality insulation material, replacement of old connection lead with superior quality PVC copper cable with stranded copper conductor from motor to connection plate, replacement of ball bearing, reassembling the motor, shifting to work site and connecting with the system, testing on full load complete all as specified and as directed by Engineer-in-Charge.
78All as per srl item No 84 here-in-before but of 250 to 500 watt, single phase electric condensor fan motor.
79Dismantling the mono block pump set with motor any make, upto7.5 HP capacity servicing by cleaning lubricating and by replacing of ball bearing gland bolt, nut and washers, terminal connector, machining of shaft, gasket, gland rope, mounting bolts, reassembling, refixing with bed and testing.
80Taking down blower with motor of AHU/Package type AC any capacity, servicing by cleaning , lubricating , machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete.
81Taking down condensor fanmotor from outdoor condensor unit of any capacity, servicing by cleaning , lubricating , machining of shaft, replacement of ball bearing mounting bolts, reassembling and testing complete.
82Replacement of Fan blade of condensor fan motor of suitable size all as specified and directed.
83Supply and fixing in replacement in replacement of water pressure gauge 4” dia, range 0 to 100 Psi complete all as specified or as directed by Engineer-in-Charge. Make:- Fiebig/Guru/york
84Supply and fixing in replacement of V- beltheavy duty complete all as specified or as directed by Engineer-in-Charge. Make:- Fenner/Dunlop or equivalent
85Supply and fixing in replacement in replacement ofthermostatexpansionvalvesuitableforACplant50trcapacitycompleteall as specified and directed. Make:- Sporlan/ Danfoss/ Renutrol or equivalent.
86Supply and fix in replacement Finned strip heater made of GP sheathing having terminals at one end and two holes for horizontal installation of capacity 3 KW in Air Conditioningplant installed at various locations complete all as specified or as directed.Make:- Daspass/Lazer/Usha
87Replacement of PVC honey comb fills (drift eliminators) suitable size of central type AC plant plant all as specified and directed.
88Supply and fix Single phase preventor having voltage unbalance and phase reversal protection. Make GIC/L&T or other equivalent approved make.
89Replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter.Make L & Tor equivalent.
90Supply and fixing in replacement of PCB in the existing Packed unit/ Cold room AC Plant including necessary control wiring as required.Make - Softhard Automation Pvt Ltd or in equivalent.
91Supply and fixing in replacement Contactor MNX, 32 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
92Supply and fixing in replacement Contactor MNX, 45 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
93Supply and fixing in replacement Contactor MNX, 25 amp 3 pole, coil voltage as per existingcomplete all as specified and as directed. Make - Siemens/BCH/L&T/Schneider.
94Supply and fixing in replacement toggle 5 Amp switch two way brass handle as per sample.
95Supply and fixing in replacement of pressure switchLP/HP cut out M15 as per sample. Make- Danfoss/indfoss
96Supply and fixing in replacement over load Relay 6 to 10 Amp Make -Siemens/BCH/L&T/Schneider.
97Supply, fixing, connecting, and testing condenser fan motor of outdoor air-cooled condensers of AC plant/cold storecapacity 5.5 TR/7.5TR/11TR as per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
98Supply, fixing, connecting, and testing evaporatorfan motor of cold store capacity 5.5TR/8.5 TRas per existing type and size including taking out of unserviceable motor complete all as per specified and directed.
99Supply, fixing, connecting, and testing molecular drier cum strainer on line type of size 3/8" x 3/8" make Danfoss in AC plant capacity 5.5/7.5/11/12/13/17 TR as per existing type and size including taking out of unserviceable drier complete all as per specified and directed.
100Supply and lay electricalinsulating rubber mat class ‘B’ conforming to IS 5424 (ISI marked) of 15 mm thick of size 1mx2m, suitable for HT/LT switch gearscomplete all as specified and directed. Make : Jyoti/Vardhman or equivalent.
101M & L Check for any refrigerant leaks through flare joints, valve glandsor any of the loc in refrigerantsystem which requires leak detector device, soap solution,halide torch or electronic leak detector and arresting leakages including necessary welding, brazing works binding with teflon tape as required at site andtopping upthe gas for required suction & discharge pressurefor37.5 TR central type AC Plant. Note : Refrigerantshall be measured and paid seperately.
102Material and labour for charging Nitrogen Gas in 37.5 TR capacity centralAC plant maintaining pressure 350 Psi for checking of Gas leakage and removing water vapour choked in line, flushing out the complete system including gas leakage and detection with halide torch/ soap foam solution in system including gas welding flushing and making good the pipe line to make the system leak proof complete all as specified and as directed.
103M&L for vacuumising the plant by using vaccum pump up to (-) 30 PSIG pressure and hold the same under vaccum pressure upto 24 hours including necessary welding and brazing if required complete all as specified and directed for 37.5 TRAC plant .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail