Military Engineer Services-MES has published Tender For Repair/ Maint Of Street Light And Connected Items For Aor Of Hq 13 Sect Under Age(I) Cif(R).. Submission Date for this Tender is 22-05-2024. Machine Tools Tenders in UDHAMPUR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

43264074
Tender For Repair/ Maint Of Street Light And Connected Items For Aor Of Hq 13 Sect Under Age(I) Cif(R).
Open Tender
Indian
Jammu And Kashmir
UDHAMPUR
22-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair / Maint Of Street Light And Connected Items For Aor Of Hq 13 Sect Under Age ( I ) Cif ( R ) .-M&L Under Ground Xlpe Insulated, Screened, Pvc Bedded Galvanized Steel Strip Or Wire Armored, Electric Power Cable ( Heavy Duty ) With Aluminium Conductor, 1100 Volts ( Earthed ) Grade Cross Sectional Area 25 Sqmm, 3.5 Core Laid In Trenches / Pipes / Ducts / Wall / Boarings With Necessary Cable Lugs And Glands, Nuts, Bolts And Washers Etc And Testingincluding Disconnecting And Taking Out Of Existing Lt Cable Of Any Type And Size Complete All As Specified And Directed.Note:- Excavation And Earth, Sand Coushioning And Protection For Cable Work Shall Be Measured And Paid Separately. 2 All As Per Item No. 1 Here-In-Before But Cross-Sectional Area 16 Sqmm, 4 Core Complete. 3 All As Per Item No. 1 Here-In-Before But Cross-Sectional Area 16 Sqmm, 2 Core Complete. 4 M&L For Gi Pipe 40 Mm Dia Light Grade Isi Marked, Laid In Trenches / On Floors / On, Pole / Road For Cable Protection Including Necessary Joints / Fittings Including Taking Up / Down And Removing Old Unserviceable Gi Pipe Complete All As Specified And Directed . 5 Excavation In Trenches, In Any Type Of Soil Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth For Foundation, Etc Or Not Exceeding 10 Sqm On Plan And Not Exceeding 1.5M In Depth For Pole, Cable, Shafts, Cesspits, Manholes, Pier Holes, Etc And Getting Out Of Any Type Of Soil Complete All As Specified And Directed. 6 All As Per Item No: 5 Above But Depth Exceeding Beyond 1.5Mtr And Not Exc 3 Metre All As Specified And As Directed 7 Removing Excavated Soil To A Distance Not Exceeding 50 M And Depositing Where Directed At A Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And Directed. 8 Returning, Filling In Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exc. 25 Cm Thick In Soils, Complete All As Specified And As Directed. 9 Sand Cushioning With Fine Sand To Under Ground Cables In Trenches / Ducts In Layers Of 8 Cm Deep Before Laying The Cable And 15 Cm Deep After Laying And Stretching The Cable As Specified In Clause 19.75 Of Ssr Part-I, Complete All As Specified And Directed By Engr-In-Charge. 10 M&L For Brick Covering With Width Equal To Length Of Brick As Mechanical Protection To Cables With Well Burnt Sub Class ‘B’ ( Old Size ) Bricks Laid Dry Flat, Complete All As Specified And Directed. 11 M&L For Pcc 1:4:8 Type D-2Using 40Mm Graded Crushed Stone Aggregate As In Foundation Of Poles Etc Including Necessary Form Work, Complete All As Specified& Directed. 12 M&L For Pcc 1:2:4 Type B1 Using 20Mm Graded Crushed Stone Aggregate As Incoping Of Pole Etc Including Necessary Form Work, Complete All As Specified & Directed. 13 Supply, Fixing And Erection Of Steel Tubular Swaged Pole 09 M Long, Type 410 Sp-32, Weight Not Less Than 154 Kgs, Pole Should Be In One Piece Only And Smooth Finishing, Isi Marked Conforming To Is:2713-1980, Complete With All Accessories, Such As Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts, Screws, Washers And Drilling Of Holes For Continious Gi Earth Wire As Specified Including Applying Two Coats Of Aluminium Paint Over One Coat Of Red Oxide Zinc Chrome Primer And Embedded Portion Shall Be Painted With Two Coats Of Black Paint After Preparation Of Surface Including Taking Down Old Unserviceable Pole Complete All As Specified And Directed.Note:-Excavation And Earth Work Shall Be Measured And Paid Separately. 14 M&L For Replacement Of Gi Bracket Bend To Shape, Made Out Of40 Mm Dia Gi Pipe Medium Grade Suitable For Fixing Of Street Light Fittings Upto 1.2 Mtr Long Fixed With And Including Two Sets Of Ms Clamp Made Out Of Flat Iron Of Size 50X6 Mm, Fabricated To Shape And Fixed With Nuts, Bolts & Washers & Two Coats Of Aluminum Paint Over A Coat Of Red Oxide Primercomplete All As Specified And Directed By Engr-In-Charge. 15 S&F In Replacement Of Wiring With Two Nos Single Core Pvc Insulated ( Unsheathed ) Multi Strand Copper Conductor Frls Cable Of Size 1.5 Sqmm And One Single Core Pvc Insulated ( Unsheathed ) Multi Strand Copper Conductor Frls Cable Of Size 1.5 Sqmm As In Continuous Earth Wire Drawn Into Steel Pole For Connection To Security Lights From Junction Box Fitted On Pole Complete All As Specified And As Directed By The Engineer In Charge. 16 M&L For Replacement Of Junctionboxhot Press Moulded Smcof Inside Dimension Size 333 X 233 X 120 Mm With Locking Arrangements Consisting Of Necessary Suitable Arrangements For Incoming & Out Going Cables With Cable Glands & Having Aluminium Bus Bar4 Strips Of 20X3mm For Tpn On Necessary Epoxy Base Insulator Andfixing Of 6 Amp Mcb Sp, Including Necessary 25X3mm Flat Iron Clamps With Nuts, Bolts & Washers All As Specified And Directed. 17 M & L For Pole Painting 9.0 Mtr Long With Two Coat Of Aluminium Paint After Preparation Of Old Painting Surface By Scrappining Including Marking Of Black And Yellow Strip Not Less Than 30 Cm Width With Sythethic Enamelled Paint From Couping To Upto Height 1.5 Mtr Of Pole Alternative Way Including Necessary `Mes & Pole Number To Be Wriiten In The Circular Yello Batch On The Pole All As Specified And Directed. 18 S&F In Replacement Of Led Street Light Drivers Of Size 90 Wattfor Existing Model Of Led Fitting, Complete All As Specified & Directed. 19 S&F In Replacement Of Led Street Light Drivers Of Size 120 / 150 Wattfor Existing Model Of Led Fitting, Complete All As Specified & Directed. 20 S&F In Replacement Of Led Street Light Surge Protector 5 Ka 60 / 75 Wattfor Existing Model Of Led Fitting, Complete All As Specified & Directed. 21 S&F In Replacement Of Led Street Light Surge Protector 10 Ka 90 / 150 Wattfor Existing Model Of Led Fitting, Complete All As Specified & Directed. 22 S&F In Replacement Of Off Load Change Over Switch 63 Amps 415 Volts 4 Pole 50 Hz In Sheet Metal Enclosure With Out Side Handel Operated Complete All As Directed By Engr In Charge. 23 S&F In Replacement Of Off Load Change Over Switch 100 Amps 415 Volts 4 Pole 50 Hz In Sheet Metal Enclosure With Out Side Handel Operated Complete All As Directed By Engr In Charge. 24 S&F In Replacement And Testing Of Moulded Case Circuit Breaker ( Mccb ) , Adjustable Thermal And Fixed Magnetic Type, , 4 Pole, 415 Volts, 50Hz, Breaking Capacity 16Ka, Rating 100Amp, Complete As Per Oem Standard Design, All As Specified And As Directed By Engineer-In-Charge. 25 S&F In Replacement And Testing Of Moulded Case Circuit Breaker ( Mccb ) , Adjustable Thermal And Fixed Magnetic Type, , 4 Pole, 415 Volts, 50Hz, Breaking Capacity 36Ka, Rating 160Amp, Complete As Per Oem Standard Design, All As Specified And As Directed By Engineer-In-Charge. 26 S&F In Replacement And Testing Of Moulded Case Circuit Breaker ( Mccb ) , Adjustable Thermal And Fixed Magnetic Type, , 4 Pole, 415 Volts, 50Hz, Breaking Capacity 36Ka, Rating 200Amp, Complete As Per Oem Standard Design, All As Specified And As Directed By Engineer-In-Charge. 27 S&F In Replacement Of Aluminium Cable Thimbles Of Size 120 Sqmm Ug Cable Including Complete Connection And Crimping, Complete All As Specified. 28 All As Per Item No.27 Above But 95 Sqmm. 29 All As Per Item No.27 Above But 50 Sqmm. 30 All As Per Item No.27 Above But 35 Sqmm. 31 All As Per Item No.27 Above But 25 Sqmm. 32 S&F In Replacement Of Integral Led Security Light Luminaire 60W Led 230 Volts Made Of Pressure Die Cast Aluminium Housing Powder Coated With High Power Smd Led’S Lens & Toughned Glass Ip-66, Luminaire Efficacy >125 Lumens Per Watt, Secondary Optics For Better Light Distribution, Having Two Nos Potted Driver ( Oem ) ( One Inbult And One Spare Potted Driver ) 4Kv Internal +10Kvspd, Thd<10%, Pf>0.95 And Taking Down Old Unserviceable Light Fittings Any Type / Wattage Complete All As Specified And As Directed. Make: Havells Cat Ref No.Endurasundownsl60wled765pasybotg Or Equivalent Cat Part Of Make As Specified In List Of Make Here-In-After. 33 S&F In Replacement Of Integral Led Security Light Luminaire 90W Led 230 Volts Made Of Pressure Die Cast Aluminium Housing Powder Coated With High Power Smd Led’S Lens & Toughned Glass Ip-66, Luminaire Efficacy >125 Lumens Per Watt, Secondary Optics For Better Light Distribution, Having Two Nos Potted Driver ( Oem ) ( One Inbult And One Spare Potted Driver ) 4Kv Internal +10Kvspd, Thd<10%, Pf>0.95 And Taking Down Old Unserviceable Light Fittings Any Type / Wattage Complete All As Specified And As Directed. Make: Havells Cat Ref No.Endurasundownsl90 Wled765pasybotg Or Equivalent Cat Part Of Make As Specified In List Of Make Here-In-After. 34 S&F In Replacement Of Integral Led Flood Light Luminaire 100W Led 230 Volts Made Of Pressure Die Cast Aluminium Housing Powder Coated With High Power Smd Led’S Lens & Toughned Glass Ip-66, Luminaire Efficacy >125 Lumens Per Watt, Secondary Optics For Better Light Distribution, Having Two Nos Potted Driver ( Oem ) ( One Inbult And One Spare Potted Driver ) 4Kv Internal +10Kvspd, Thd<10%, Pf>0.95 And Taking Down Old Unserviceable Light Fittings Any Type / Wattage Complete All As Specified And As Directed. Make: Havells Cat Ref No.Jetaalbafloodlight100w Or Equivalent Cat Part Of Make As Specified In List Of Make Here-In-After. 35 Material And Labour For Earthing Complete With Galvanized Steel Plate Electrodes Of Size 600Mm X600mm X 6Mm Thick Buried Dirctly In Ground With Earth Pit Not Lesss Than 2.25M Deep Below Normal Ground Level With Top Edge Of Plate Not Less Than 1.5 M Below Normal Ground Level Connected To Galvanized Iron Strip Of 25 X 4 Mm Earthing Lead By Means Of Nuts Bolts Check Nuts Gi Washers Earth Wire Protected By Gi Pipe 32 Mm Bore, Light Grade, Including Concrete Pit In Pcc ( 1:3:6 ) Type C1 Of Size 45X45x45 Cm, Precast Rcc ( 1:2:4 ) Type B1 As Cover Of Size 40X40x10 Cm With One Handle For Lifting Made Out Of 8 Mm Dia Ms Bar, Gi Funnel Wire Mesh, 20 Mm Bore Gi Pipe, Medium Grade, For Watering, Charcoal Or Coke And Salt Packed All Around In Alternate Layers Necessary Earth Work In Soft / Loose Soil Complete All As Shown In Electrical Plate No 3 Of Ssr Part-I Including Testing On Completion Including Demolition To Existing One Complete All As Specifed And Directed. ( Note :- ( I ) Pcc Pit, Rcc Pit Cover, Gi Earth Protection & Watering Pipe, Funnel, Earth Strip Upto 7.5 Mtr Etc Shall Deemed To Be Included In The Unit Rate. 36 Deduction To Be Made From Boq For Schedule Of Credit ( Sch A Part - Ii ) Amount Of ? 28, 365.00During Aocnote:- Tenderers Shall Not Quote For This Schedule

Key Value

Document Fees
INR 500 /-
EMD
INR 19800.0 /-
Tender Value
INR 9.90 Lakhs /-

Attachment

FileName File Description File Size
92dd64f4-d30d-479f-9b04-9dcff226bb84.html Tender Notice 0 KB
BOQ_729382.xls Tender Document 0 KB
TenderDocument10.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work:REPAIR/ MAINT OF STREET LIGHT AND CONNECTED ITEMS FOR AOR OF HQ 13 SECT UNDER AGE(I) CIF(R).
Sl. No. Item Description
1M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 25 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testingincluding disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
2All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 4 core complete.
3All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 2 core complete.
4M&L for GI pipe 40 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .
5Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, cable, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed.
6All as per Item No: 5 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed
7Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
8Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
9Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge.
10M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
11M&L for PCC 1:4:8 type D-2using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified& directed.
12M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as incoping of pole etc including necessary form work, complete all as specified & directed.
13Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-32, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking down old unserviceable pole complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid separately.
14M&L for replacement of GI bracket bend to shape, made out of40 mm dia GI pipe medium grade suitable for fixing of street light fittings upto 1.2 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primercomplete all as specified and directed by Engr-in-charge.
15S&F in replacement of wiring with two nos single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into steel pole for connection to security lights from junction box fitted on pole complete all as specified and as directed by the Engineer in charge.
16M&L for replacement of junctionboxhot press moulded SMCof inside dimension size 333 x 233 x 120 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar4 strips of 20x3mm for TPN on necessary epoxy base insulator andfixing of 6 Amp MCB SP, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed.
17M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed.
18S&F in replacement of LED street light drivers of size 90 wattfor existing model of LED fitting, complete all as specified & directed.
19S&F in replacement of LED street light drivers of size 120/150 wattfor existing model of LED fitting, complete all as specified & directed.
20S&F in replacement of LED street light surge protector 5 KA 60/75 wattfor existing model of LED fitting, complete all as specified & directed.
21S&F in replacement of LED street light surge protector 10 KA 90/150 wattfor existing model of LED fitting, complete all as specified & directed.
22S&F in replacement of Off load change over switch 63 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge.
23S&F in replacement of Off load change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge.
24S&F in replacement and testing of moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed by Engineer-in-charge.
25S&F in replacement and testing of moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 160Amp,complete as per OEM standard design,all as specified and as directed by Engineer-in-charge.
26S&F in replacement and testing of moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 200Amp,complete as per OEM standard design,all as specified and as directed by Engineer-in-charge.
27S&F in replacement of aluminium cable thimbles of size 120 Sqmm UG Cable including complete connection and crimping, complete all as specified.
28All as per Item No.27 above but 95 Sqmm.
29All as per Item No.27 above but 50 Sqmm.
30All as per Item No.27 above but 35 Sqmm.
31All as per Item No.27 above but 25 Sqmm.
32S&F in replacement of Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >125 Lumens per Watt,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KVSPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: Havells cat ref No.ENDURASUNDOWNSL60WLED765PASYBOTG or equivalent cat part of make as specified in list of make here-in-after.
33S&F in replacement of Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >125 Lumens per Watt,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KVSPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: Havells cat ref No.ENDURASUNDOWNSL90 WLED765PASYBOTG or equivalent cat part of make as specified in list of make here-in-after.
34S&F in replacement of Integral LED flood light luminaire 100W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >125 Lumens per Watt,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KVSPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: Havells cat ref No.JETAALBAFLOODLIGHT100W or equivalent cat part of make as specified in list of make here-in-after.
35Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 x 4 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate.
36Deduction to be made from BOQ for schedule of credit (Sch "A" Part - II) Amount of ? 28,365.00during AOC Note:- Tenderers shall not quote for this Schedule
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail