Military Engineer Services-MES has published Tender For Repair And Cleaning Of Sewage Line Manholes Etc At Stn Road Maude Rd Esd Fol Depot Airport Road Kabul Lines Under Aor Of Age Br Ii Of Ge North Delhi Cantt 10. Submission Date for this Tender is 20-05-2024. Sewerage Construction Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

43264069
Tender For Repair And Cleaning Of Sewage Line Manholes Etc At Stn Road Maude Rd Esd Fol Depot Airport Road Kabul Lines Under Aor Of Age Br Ii Of Ge North Delhi Cantt 10
Open Tender
Indian
Delhi
delhi
20-05-2024

Tender Details

Repair And Cleaning Of Sewage Line Manholes Etc At Stn Road Maude Rd Esd Fol Depot Airport Road Kabul Lines Under Aor Of Age Br Ii Of Ge North Delhi Cantt 10

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR AND CLEANING OF SEWAGE LINE, MANHOLES ETC AT STN ROAD, MAUDE RD, ESD, FOL DEPOT, AIRPORT ROAD, KABUL LINES UNDER AOR OF AGE B/R-II OF GE (NORTH) DELHI CANTT-10
Sl. No. Item Description
1Excavation in trenches, in any type of soil not exceeding 1.50m wide and not exceeding 1.50m in depth; for foundation, etc. and getting out complete all as specified and directed.
2All as per the description of srlitem No 1 above but exc 1.50m but not exc 3.00m in depth.
3Removing excavated spoil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, complete, all as specified.
5M&L for 100mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer"s instructions including demolition and breaking up old sewage line of any type and any diaset in cement mortar including demolition of PCC huanching and beddingcomplete all as specified and directed.
6M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer"s instructions including demolition and breaking up old sewage line of any type and any diaset in cement mortar including demolition of PCC huanching and beddingcomplete all as specified and directed.
7M&L for 200mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer"s instructions including demolition and breaking up old sewage line of any type and any diaset in cement mortarincluding demolition ofPCC huanching and beddingcomplete all as specified and directed.
8M&L for 300mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer"s instructions including demolition and breaking up old sewage line of any type and any diaset in cement mortarincluding demolition ofPCC huanching and bedding complete all as specified and directed.
9M&L for concrete bed to drain pipe/sewage pipe of any dia including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concretePCC 1:4:8type C-2 (Using 40mm gradedcrushed stone aggregate) complete all as specified and directed.
10Supply and laying, jointing150mm internal dia of salt glazed stoneware pipes grade "A"including testing and laid in trenches to a level on concrete bed,including demolition and breaking up old sewage line of any type and any diaset in cement mortarincluding demolition ofPCC huanching and beddingcomplete all as specified and directed.
11All as per the description of srl item No.10 here-in-before but200mm internal dia of salt glazed stoneware pipes grade "A" complete all as specified and directed.
12Supply & laying 150mm bore reinforced concrete pipes, class NP2 pipes with spigot and socket joints, laid and jointed in trenches to a level on concrete bed,including demolition and breaking up old sewage line of any type and any diaset in cement mortarincluding demolition ofPCC huanching and beddingcomplete all as specified and directed.
13All as per the description of srl item No. 12 here-in-before but200mm internal dia RCC class NP-2 pipes.complete all as specifiedand as directed.
14S&FPVC(SWR) pipes, 75mm external dia double socketed in any length with rubber joints, fixed to walls etc withmild steel clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified.
15S&F PVC (SWR) bends suitable for 75mm external dia with or without access door complete all as specified and directed.
16S&F PVC (SWR) junction single, (single T&Y) equal or unequalwith or without access door conforming to IS: 14735, suitable for PVC soil waste discharge pipe of 75mm dia Complete all as specified and as directed.
17S&F PVC (SWR) pipes, 110mm external dia,type-B, ISI marked (IS:13592) double socketed in any length with rubber ring joints, fixed to walls etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified and directed.
18S&F PVC (SWR) bends suitable for 110mm external dia with or without access door complete all as specified and directed.
19S&F PVC (SWR) junction single, (single T&Y) equal or unequalwith or without access door conforming to IS: 14735, suitable for PVC soil waste discharge pipe of 110mm dia complete all as specified and as directed.
20S&F in repair 75mm bore HDPE pipes PN-10 single socketed in any length with rubber ring joints, fixed to walls with clamps etc including taking out /dismantling of old pipes any type and description complete all as specified and directed. Note:- Rate including hanging arrangement for fixing ofpipes in shaft of Building (up to G+8 Storey)
21S&F in repair 110mm bore HDPE pipes PN-10 single socketed in any length with rubber ring joints, fixed to walls with clamps etc including taking out/dismantling of old pipes any type any descriptioncomplete all as specified. Note:- Rate including hanging arrangement for fixing ofpipes in shaft of Building (up to G+8 Storey)
22S&F in repairs stack clamps for 75mm bore pipe out of 50mm by 5mm flat iron and 16mm dia round iron stays, inbolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
23S&F in repairs stack clamps for 110mm bore pipe out of 50mm by 5mm flat iron and 16mm dia round iron stays, inbolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
24S&F in repairs 110mm bore HDPE pipes PN-10 single socketed in any length with rubber ring joints, laid in trenches or in floor etc including taking out/dismantling of old pipes complete all as specified and directed.
25S&Fin repairsHDPE bends any radius bore 75mm, complete all as specified and directed.
26S&Fin repairsHDPE bends any radius bore 110mm, complete all as specified and directed.
27S&Fin repairs HDPE junction single, (Single T) equal or unequal bore 110mm with access door complete all as specified and directed.
28S&Fin repairsHDPE "P" Trap 110mm dia, complete all as specified and directed.
29S&Fin repairsHDPE "S" Trap110 mm dia, complete all as specified and directed.
30Taking up or down steel tubing 25mm bore and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
31Taking up or down steel tubing 40mm bore and connection, including cleaning for refixing or removal to store, complete all as specified and directed.
32S&F in repairs of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors includingcomplete all as specified and directed. Note:-(i) Rate including hanging arrangement for fixing of GI pipes in shaft of building (up to G+8 Storey) (ii) The rate alsoincludes the cost of thelabour involved in all the operations describedfor special fittings. (iii) Only the cost of extra over itemfor provision of special fittings brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor , unions, ball valves and tank adaptor which may be required, shall be paid for separately items.
33M&L 25mm bore tubes medium gradegalvanised, with all fittings and fixed, complete to walls, ceiling or laid in floor complete all as specified and directed. Note:- Rate including hanging arrangement for fixing of GI pipes in shaft of Building (up to G+8 Storey)
34M&L 40mm bore tubes medium gradegalvanised, with all fittings and fixed, complete to walls, ceiling or laid in floor complete all as specified and directed. Note:- Rate including hanging arrangement for fixing of GI pipes in shaft of Building (up to G+8 Storey)
35Supply only brass elbow (3/4 x ½)for 20mm dia CPVC pipe fittings, complete all as specified and directed.
36Supply onlybrass Tee (3/4 x ½) 20mm dia for CPVC pipe fittings, complete all as specified and directed.
37Supply onlymale brass threaded adaptor(MTA/ MBTA)20mm dia for CPVC pipe fittings, complete all as specified and directed
38Supply onlyfemale brass threaded adaptor (FTA/ FBTA) 20mm dia for CPVC Pipe fittings, complete all as specified and directed
39Supply onlytank adaptor20mm dia for CPVC pipe fittings, complete all as specified and directed.
40Supply only union 20mm dia for CPVC pipe fittings, complete all as specified and directed.
41Supply only ball valve / gate valve20mm dia for CPVC pipe fittings, complete all as specified and directed.
42M&L for cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing/ CPVC pipe or etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
43Cleaning ofEWCs, IWCs, bottle traps, nahani traps, gully traps and floor traps etc and CI/PVC pipes all types, top to bottom including junctions etc,cleaning of sewage line upto GTcomplete all as specifiedand as directed.
44Cleaning of manhole up to 1.00 meter depthany size of manhole and taking out sludge and depositing the same in notified area by Municipal Corp of Delhifor dumpingorout side Defence land complete all as specifiedand as directed.
45Cleaning of manhole depth exc1.00 meter and n exc 2.00 meter of any size of manhole and taking out sludge and depositing the same in notified area by Municipal Corp of Delhifor dumpingorout side Defence land complete all as specifiedand as directed.
46Cleaning of sewage line from GT to Ist manholecomplete all as specifiedand as directed. Note:-Cleaning of sewage line of daimeter upto 100mm to 150mm
47Cleaning of sewage line 100mm dia from manhole to man hole by manual/ mechanical roding removing all sludge/waste and making the line functional including depositing of all waste etc out side MOD land as notified by Municipal Corporation of Delhi complete all as specifiedand as directed.
48Cleaning of sewage line 150mm dia from manhole to man hole by manual/ mechanical roding, removing all sludge/waste and making the line functional including depositing of all waste etc out side MOD land as notified by Municipal Corporation of Delhi complete all as specifiedand as directed.
49Cleaning of sewage line 200mm dia from manhole to manhole by manual/ mechanical roding, removing all sludge/waste and making the line functional including depositing of all waste etc out side MOD land as notified by Municipal Corporation of Delhi complete all as specifiedand as directed.
50Cleaning of sewage line 300mm dia from manhole to manhole by manual/ mechanical roding, removing all sludge/waste and making the line functional including depositing of all waste etc out side MOD land as notified by Municipal Corporation of Delhi complete all as specifiedand as directed.
51Dewatering / desludging of septic tanks, soakage wells etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and burried off the same out side the defence area notified by Municipal Corporation of Delhi complete all as specified and directed.
52Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
53Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, including cutting of trees, shrubs or any type of vegitation upto and including roots complete all as specified and directed.
54M&L for brick work with sub class `B" bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 including demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articlescomplete all as specified.
55M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and sooth without using extra cement complete all as specified and directed.
56M&L for preperation of old/new plasterd or unplasterd surfaceand applying two coats of white washing of approved tint complete all as specified and as direcred.
57M&L for PCC 1:4:8, type D-2 using 40mm graded crushedstone aggregate as in foundation,filling and mass concrete complete all as specified and directed.
58PCC 1:2:4 type B0 using 12.50mm graded crushed stone aggregates as coping including weathering, slightly rounded, chamfered angles and finishing exposed surface even and smooth including necessary form work complete all as specified and directed.
59S&F in repairs SFRC manhole covers with and including frame medium duty over all size 900mm x 450mm x 80mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked complete all as specified and directed.
60S&F in repairs SFRC GT covers with and including frame medium duty over all size 400 mm x 400mm x 80mm thick factory made and test load 10 tonnes (MD-10), strength as per IS-12592 (2002), ISI marked complete all as specified and directed.
61Precast RCC 1:2:4 type B-1, using 20mm graded cruhsed stone aggregatescover slabs for manholes, open drains etc.including all mouldings but excluding frame, set in cement mortar 1:4 including old RCC manhole/drain cover(reinforcement cut as required to facilitate demolition) complete all as specified and directed.
62Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
63Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and direcred.
64Framed work as in opening of manhole and manhole coverof angle iron or other section,also fastening and fixing and welding with MS bars conforming to Fe-410 W Gide E-290,complete all as specified and directed.
65Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified and directed.
66M/L PCC 1:4:8, type D2, using 40mm graded crushed stone aggregate 75mm thick as in sub floor, Sub base, floor complete all as specified and directed.
67M&L for 40mm thick Sand filling under floors or in foundation including watering & consolidation etc complete all as specified and directed.
68M&L machine pressed precast rubber moulded coloured concrete interlocking paver blocks of 60mm thick any shape and size conforming to IS 15658-2006 ,M-35 grade with grey cement and nopigment complete all as specified and directed.
69M&L chequered cement concrete tiles 300mm x 300mm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement and pigment over and includng screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed.
70S&F in repairs vitreous chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs,complete all as specified and directed.
71S&F in repairs Vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts, flushing cistern and flush pipeconnection to trap and to flushing pipe inbend cluding provn of cement concrete beading complete all as specified and directed.
72S&F in repair PVC valveless, with top button double action type,syphonic action type flushing cistern, 10 litres capacity, low level, white with inlet, ball valve, float and handle, 32mm dia PVC long bend flush pipe, fixed in repairs complete all as specified and directed.
73S&F in repairs angle valve with wall flange, 15mm bore, fancy type, chromium plated with long shank and cup, cast copper alloy,screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., complete all as specified and directed.
74S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm long complete all as specified and directed.
75S&F in repairs chromium plated jet for WC with 1.00m long PVC pipe including necessary fittings complete all as specified and directed.
76S&F in repairs CP hand spray (health faucet with 1.5m long easy flex tube in chrome finish and wall hook) complete all as specified and directed.
77Supply onlyEWC Seat cover black/white coloured as approved of PVC closed pattern with flat bottom and mild steel lchromium plated or aluminised hinging device complete all as specified and directed.
78M&L non skid ceramic tiles colored tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor etc set and jointed in neat cement slurry and pointed in colour cement laid over and including 15mm thick cement mortar screed bed in CM 1:6 including dismantling floor hearth or wall tiling including cement mortar bedding and also backing, removing serviceable tiles to stores and rubbish off the premises complete all as specified and directed.
79M&L glazed digital vitrified tiles (DVT) colour and shed as approved in vertical surface of size 450mm x 300mm x 7 to 8mm thick with highlighter set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including rendering 10mm thick in CM 1:4 and finished rough including dismantling floor, hearth or wall tiling including cement mortar bedding and also backing, removing serviceable tiles to stores and rubbish off the premises complete all as specified and directed.
80Cutting into existing manholes for connecting new drains, of 100mm to 300mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required complete all as specified and directed.
81Construction of soakage wells of size 1.80m dia x 3.00m depth excavation in any types of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in drg No DZ- 1124 (R) sheet No 1/1 dated 12.02.2003 & revised upto 14.05.2004, top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in cement mortor 1:4, RCC cover slabs in M-25 and SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats including demolition of existing old soakage well of any size and refill the same up to the existing ground level complete all as specified and directed.
82Construction of soakage well of size 1.2m dia x 3.0m depthcomprising of excavation in any type of soil, foundation in PCC 1:3:6 walls of honeycomb masonry with brick work all as shown in Tdrg No DZ- 1124 (R) sheet No 1/1 dated 12.02.2003 & revised upto 14.05.2004, top ring of M-25 concrete including intercepting chamber and screen chamber made of brick mansonry in cement mortor 1:4, RCC cover slabs in M-25 and SFRC covers, interconnecting pipes of RCC/DWC complete filled with brick bats including demolition of existing old soakage well of any size and refill the same up to the existing ground level complete all as specified and directed.
83Cleaning of blockage of bathroom kitchen by cleaning nahani traps, gually traps and removing of all the mud/sludge and getting out, washing thoroughly grating of trap, CI waste pipes by opening the cleaning eyes and depositing the sludge by digging out a pit of suitable size at outside the defence area and covering the same with soil layer of thickness 30cm obtained from the excavation and earthwork complete all as specifed and directed.
84Cleaning of blockage WC indian pattern or european for removing of all the mud/sludge and getting outincluding cleaningSGSWor CIpipe upto Ist manhole and depositing the sludge by digging out a pit of suitable size at outside the defence area and covering the same with soil layer of thickness 30cm obtained from the excavation and earthwork complete all as specifed and directed.
85M&L cleaning of chocked sewer line by diesel/petrol runing vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 ltrs water jetting tank including skilled operator, supervising engineer, labour etc for cleaning and partial desilting of manholes and dechocking of sewer lines of any dia & size and in any description, dechocking and flushing of sewer line from one manholes to another by high pressure jetting system of 2200 PSI for sewer line for all depth complete all as specified and directed. Note:- Rates quoted against this item for cleaning for 08 hrs of above mentioned machine. Any work carried out for 08 hrs shall be measured as on Job. (one unit)
86M&L cleaning of chocked sewer line by diesel/petrol runing vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 8000 litres suction capacity and 10000 ltrs water jetting tank including skilled operator, supervising engineer, labour etc for cleaning and partial desilting of manholes and dechocking of sewer lines of any dia & size and in any description, dechocking and flushing of sewer line from one manholes to another by high pressure jetting system of 2200 PSI for sewer linedia for all depth complete all as specified and directed. Note:- Rates quoted against this item for cleaning for 08 hrs of above mentioned machine. Any work carried out for 08 hrs shall be measured as on Job. (one unit)