Tender For Supply And Installation Of Rmus At Various Site Under Business Plan Scheme 2024-25 In The Area Of Eudd-Vii Ghaziabad. Under The Jurisdiction Of Se, Eudc-Iii, Ghaziabad, 1 Carriage Of 11 Kv Xlpe 3X185 Sqmm Cable From Store Center To Various , Ghaziabad-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For Supply And Installation Of Rmus At Various Site Under Business Plan Scheme 2024-25 In The Area Of Eudd-Vii Ghaziabad. Under The Jurisdiction Of Se, Eudc-Iii, Ghaziabad, 1 Carriage Of 11 Kv Xlpe 3X185 Sqmm Cable From Store Center To Various . Submission Date for this Tender is 06-05-2024. Footwears Tenders in Ghaziabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43264048
Tender For Supply And Installation Of Rmus At Various Site Under Business Plan Scheme 2024-25 In The Area Of Eudd-Vii Ghaziabad. Under The Jurisdiction Of Se, Eudc-Iii, Ghaziabad, 1 Carriage Of 11 Kv Xlpe 3X185 Sqmm Cable From Store Center To Various
Open Tender
Indian
Uttar Pradesh
Ghaziabad
06-05-2024

Tender Details

Tender For Supply And Installation Of Rmus At Various Site Under Business Plan Scheme 2024-25 In The Area Of Eudd-Vii Ghaziabad. Under The Jurisdiction Of Se, Eudc-Iii, Ghaziabad, 1 Carriage Of 11 Kv Xlpe 3X185 Sqmm Cable From Store Center To Various Work Site Loading And Unloading Both Side. Distance 1 Km To 50 Km. 2 Carriage And Fixing Of 11 Kv Cable J / Kit ( 3X185 Sq.Mm ) Indoor / Outdoor From Store Center To Various Work Site Loading And Unloading Both Side. Distance 1 Km To 50 Km. 3 Supply & Fixing Of 12Kv 630 Amps 21Ka For 3 Sec. Sf6 , Bil 28 Kv / 75 Kv Peak, Extensible, Outdoor Duty 3-Way, Fully Motorised And Manually Operated Ring Mains Unit Originally Manufactured By Oem In Its Factory Only, Comprising Of 02 Load Break Switch And 01 Vaccum Circuit Breaker Consisting Of Copper Busbar In Sf6 Insulated Tank With A Provision Electromechanical Interlock To Avoid Accidental Closure Of Earthing Switch Even When Cable Is In Live Condition. Rmu Should Be Type Tested For Internal Arc Of 21 Ka For 1 Sec With Aflr Classification And Gas To Be From Rear Bottom Of The Switchgear Away From The Operator To Ensure Safety Of The Operating Personnel. Suitable Ct 200-50 / 1 A With Microprocessor Based Numerical Over Current Relay ( Idmtl + Inst. ) For Protection To Be Provided With Vcb Feeder With Right Angle Boot For Termination Kits. All The Necessary Wirings And Dummy Panel / Space For Frtu To Be Given Along With Rmu For Future Compatibility With Scada System ( Supply Of Frtu Is Not In Scope ) . Battery, Charger Etc. For Motorised Operation Of Rmu To Be Provided. The Scope Is Including Plinth / Angle Iron Stand As Per Oem Design Complete In All Respect As Per The Direction Of Engineer Incharge. Complete Rmu And Its Accessories Should Be Suitable For Altitude Of 100 Mtrs Above Sea Level. ( Makes: Abb / Siemens / Eaton / Schneider Or Authorized By Uppcl ) . Complete In All Respect. 4 Providing And Installation Of Chemical Earthing For Above Rmus ( With All Material And Labour ) After Installation Resistance Should Be Less Than One Ohm. As Per Following ( The All Material And Labour Shall Be Provided By The Contractor With 12 Month Guarantee For Resistance Value Less Than One Ohm. ) :- 5 Providing Of Earth Electrode For Chemical Earthing Pipe In Pipe Type Proper Hot Dip Galvanization Dia 50 Mm Length 3 Mtr – 32Mm X 6Mm Terminal Connection Hole Dia 8Mm The Cavity Between The Pipe & Pipe Is Filled With Conductive Mixture – For Hermetically Filling Inside The Cavity I.E. Between Secondary Conductor & Primary Conductor, Crystalline Compound Is To Be Injected In The Electrode Assembly. It Is A Combination Of High Conductivity Metal Alloys, Copper & Aluminum Power, Conductive Carbon / Cement And Bonding Material Etc. The Electrode Should Be Sealed From Both The Ends. The Outer Pipe Of The Electrode Should Be Galvanized The Characteristics Of This Compound Is Highly Conductive, Nonmagnetic & Noncorrosive In G.I. Including Providing Of Backfill Compound. Each Electrode Should Be Supplied With Bags Of 25 Kg X 2 Bfc Compound ( Ground Resistance Enhancement Powder 50 Kgs Each Cpri Tested For Rmus Installed At Above 33 / 11 Kv Substation. 6 Providing And Fabricating The Fencing At Various Site Complete In All Respect As Per Respo. 7 Laying Of 11 Kv Xlpe 3X185 Sqmm Cable At Various Site Complete In All Respect As Per Respo. 8 Making Of All Ht / Lt Connections Required To Energize The Line And Restoring Of Electricity Supply To Consumer Properly Complete In All Respect.

Key Value

Document Fees
INR 3540 /-
EMD
INR 88500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply and Installation of RMUs at various site Under Business Plan Scheme 2024-25 in the area of EUDD-VII, Ghaziabad. Under the jurisdiction of SE, EUDC-III, Ghaziabad.
Sl. No. Item Description
1Carriage of 11 kv XLPE 3x185 sqmm cable from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
2Carriage and fixing of 11 kv Cable J/Kit (3x185 Sq.mm) Indoor/Outdoor from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
3Supply & fixing of 12kv 630 Amps 21KA for 3 Sec. SF6 , BIL 28 KV/75 KV peak, extensible, outdoor duty 3-way, fully motorised and manually operated Ring Mains Unit originally manufactured by OEM in its factory only, comprising of 02 load break switch and 01 vaccum circuit breaker consisting of copper busbar in SF6 insulated tank with a provision electromechanical interlock to avoid accidental closure of earthing switch even when cable is in live condition. RMU should be Type Tested for Internal arc of 21 KA for 1 Sec with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable Ct 200-50/1 A with microprocessor based numerical over current relay (IDMTL + Inst.)for Protection to be provided with VCB Feeder with right angle boot for termination Kits. All the necessary wirings and Dummy panel/space for FRTU to be given along with RMU for future compatibility with SCADA system (Supply of FRTU is not in scope). Battery, Charger etc. for Motorised Operation of RMU to be provided. The scope is including Plinth/ Angle iron Stand as per OEM design complete in all respect as per the direction of Engineer incharge. Complete RMU and its accessories should be suitable for altitude of 100 mtrs above Sea Level. (Makes: ABB/Siemens/Eaton/Schneider or authorized by UPPCL). complete in all respect.
4Providing and Installation of Chemical Earthing for above RMUs (With all material and labour) after installation Resistance should be less than one OHM. as per following (the all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.):-
5Providing of earth electrode for chemical earthing Pipe in pipe type proper hot dip Galvanization dia 50 mm length 3 mtr – 32mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & Pipe is filled with conductive Mixture – for hermetically Filling inside the cavity i.e. between secondary conductor & Primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc. The electrode should be sealed from both the ends. The outer pipe of the electrode should be galvanized the characteristics of this compound is highly conductive, nonmagnetic & noncorrosive in G.I. Including providing of backfill compound. Each electrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for RMUs installed at above 33/11 KV Substation.
6Providing and fabricating the Fencing at various site complete in all respect as per respo.
7Laying of 11 kv XLPE 3x185 sqmm cable at various site complete in all respect as per respo.
8Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect.