Tender For Repair Replacement Of Lt Oh Line, Ug Cables And Connected Items Of Electric Supply In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt, amritsar-Punjab

Military Engineer Services-MES has published Tender For Repair Replacement Of Lt Oh Line, Ug Cables And Connected Items Of Electric Supply In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt. Submission Date for this Tender is 27-05-2024. Cable Supply Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43264024
Corrigendum : Tender For Repair Replacement Of Lt Oh Line, Ug Cables And Connected Items Of Electric Supply In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt
Open Tender
Indian
Punjab
amritsar
27-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Repair Replacement Of Lt Oh Line, Ug Cables And Connected Items Of Electric Supply In The Area Of Age Br-Ii Under Garrison Engineer Amritsar Cantt

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-May-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-05-2024
2 21-May-2024 Corrigendum NO 01 Other 27-05-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
c55d0343-98c2-403d-a61d-d50952778231.html Tender Notice 0 KB
BOQ_729380.xls Tender Document 0 KB
TENDER19.pdf Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

NAME OF WORK: REPAIR REPLACEMENT OF LT OH LINE, UG CABLES AND CONNECTED ITEMS OF EXTERNAL ELECTRIC SUPPLY IN THE AREA OF AGE BR-II UNDER GARRISON ENGINEER AMRITSAR CANTT .
Sl. No. Item Description
1Material and Labour for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both sideof the OH line with JCB, Cutter and all tools, plants etc ; Complete all as specified and as directed by Engineer-in-Charge. Note :(i) Distance between pole to pole will be measured and paid. (ii)Contractor has to take outmost care to avoid damage to existing lines/structures. If any breakdown of line is caused during prunning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season)(iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening.If any mishappening occurs the contractor will be solely responsible for it.
2Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out on soft/ lose soil and addedadditional 1.5 m or part thereof in depth beyond the first 1.5 mtr; Complete all as specified and as directed by Engineer-in-Charge.
3Excavating in trenches n exc 1.5 mtr wide and n exc 1.5m in depth , for foundation ,etc or for shafts, wells , cesspits, main holes etc.n exc 10 sqm on plan and n exc 1.5 mtr depth and getting out onhard / dense soil and addedadditional 1.5 m or part thereof in depth beyond the first 1.5 mtr; Complete all as specified and as directed by Engineer-in-Charge.
4Returning, filling in, including spreading , levelling , watering and well ramming in layers not exc 25cm of any soil; Complete all as specified and as directed by Engineer-in-Charge.
5Removing excavated materials(soils) n exc 50m and depositing where directed at a level n exc 1.5m above the starting point; Complete all as specified and as directed by Engineer-in-Charge.
6Supply & laying HDPE pipeIS-16205 (part-24)ID-75 mm bore for laying of LT cables etc; Complete all as specified and as directed by Engineer-in-Charge.
7Supply & laying HDPE pipeIS-16205 (part-24)ID-95 mm bore for laying of LT cables etc; Complete all as specified and as directed by Engineer-in-Charge.
8Supply & laying HDPE pipeIS-16205 (part-24)ID-103 mm bore for laying of LT cables etc; Complete all as specified and as directed by Engineer-in-Charge.
9Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 10 sqmm 4 Core,; Complete all as specified and as directed by Engineer-in-Charge.
10Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 16 sqmm 4 Core,; Complete all as specified and as directed by Engineer-in-Charge.
11Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 25 sqmm 4 Core,; Complete all as specified and as directed by Engineer-in-Charge.
12Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 35 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
13Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 50 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
14Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 70 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
15Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 95 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
16Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 120 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
17Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 150 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
18Supply and Laying in trenches or drawn through pipe or fixed on wall / poles , LT UG cable 1100 Volts, heavy duty XLPE insulated, screened, PVC bedded, galvanised steel strip or wired armoured with aluminium conductor after removing old one of followingsize:- 300 Sqmm 31/2 core,; Complete all as specified and as directed by Engineer-in-Charge.
19Material and Labour for making good the damaged Tar Road by using additional stone metal, PCC etc ; Complete all as specified and as directed by Engineer-in-Charge.
20Material and Labour for repairs of LT Panel board of any size with replacing the unserviceable MCCB,MCB,switch fuse unit , change over ,Busbar,etc jointig cable with proper lugs ,nut , bolt and washers, cleaning the panel by using of CRC Soluation and repairing thhe panel door by using hinges and repairing the lock system, welding etc painting the LT Panel wit one coat of primer & two coat of synthetic enamel paint as approvedor as per direction of Engr-in-Charge. Note:(i)MCCB,MCB,Switch fuse unit and change over switch measured and paid separately. (ii) Labour for MCCB, MCB, Switch fuse unit and change over switch measured and paid separately. (iii)Rate of newBusbar, panel door, cable gland, lugs,CRC Solution,nut,bolt, paintingetc and washersare deemed to be included in quoted rates.
21Material and Labour for repairs of existing Amp meter (0-300Amp) by digital one along with unserviceable CT if any from existing LT Panel of any size; Complete all as specified and as directed by Engineer-in-Charge.
22Material and Labour for repairs of existing Volt meter 0 to 600 volt , digital type from existing LT Panel of any size,; Complete all as specified and as directed by Engineer-in-Charge.
23Material and labour forpainting ofLT Steel tubular pole,9 mtr long with two coats ofsynthetic enamel paint including prepartion of surfaces,Scraping the old paint and writingpole No in Black letter under yellow circle; Complete all as specified and as directed by Engineer-in-Charge.
24Material and labour forpainting ofLT Steel tubular pole,11 mtr long with two coats ofsynthetic enamel paint including prepartion of surfaces,Scraping the old paint and writingpole No in Black letter under yellow circle; Complete all as specified and as directed by Engineer-in-Charge.
25Material and labour for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried verticallyin ground (Each pit not less than 2.25 mtrs deep below normal ground level with top edge of plate not less than 1.50 M below normal ground level) connected to GI strip 32 x 6 mm , by means of bolts, nuts, and check nuts and washers etc encased in GI protection pipe 40 mm dia light grade pipe for protection of GI earth strip both to be provided to the extet of 7.5 meters, all as shown on electrical plate No 3 of MES SSR - 2004 Part - I, GI protection pipe buried in ground, laid under floors / plinths or mixed on walls / pole etc or concealed in walls etc; with provision of mixture of charcoal dust and common salt packed upto minimum 150 mm all around the earth plate, including PCC 1:2:4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with GI 20 mm dia medium grade pipe and MS funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata and testing on completion; Complete all as specified and as directed by Engineer-in-Charge. Note:- i) Cost of GI strip 32 x 6 mm and protection pipe 40 mm dia is deemmed to be included in rate quoted ii) Excavation and returning filling of Soil any type is deemed to be included in rates. iii) The earthingdone in presence of JE /E-in-Charge will only be measured. iv) The material required for earthing will be first approved from E-in-charge before bulk procurement
26Material and Labour for checking of HT UG 11 KV XLPE faulty cable with HT UG cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as all as specified and directed.Approx length 500 RM for each Job.(The rate for excavation, removing of old cable, laying after repairs is demmed to be included in the rate quoted by the contractor).
27Supply ,Installing, commissioning and testingin replacement LT bus bar, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 2 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside depth not less than 50 cm and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories; Complete all as specified and as directed by Engineer-in-Charge. (a)MCCB 200 Amp four polewith Breaking Cap 25 KA-01 No(Incoming) (b) Volt Meter (digital Type (0 T0 600 Volts)-01 No (c ) Ammeter (digital type) with Cts 0-300Amps)-01 No (d) Phase indication lamps LED type with holder-01 Set(Set of Three)
28Supply ,Installing, commissioning and testingin replacement LT bus bar, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 2 mm thick CRCA sheet and inner sheet of 2.0 mm thick and angle iron frame of size 50x50x5mm inside depth not less than 90 cm ( 45 cm grouted in PCC) and size suitable to accommodate the following accessories, with insulated alluminium busbar 200amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories all as directed. (a)MCCB 100 Amp four polewith Breaking Cap 25 KA-01 No(Incoming) (b) Volt Meter (digital Type (0 T0 600 Volts)-01 No (c Ammeter (digital type) with Cts 0-300Amps)-01 No (d Phase indication lamps LED type with holder-01 Set(Set of Three)
29Supply ,Installing, commissioning and testingin replacement LT panel board, factory made, out door, cubical type , vermin proof, dust proof, cubical type, vermin proof , dust proof, water proof made out of 3.15 mm thick CRCA sheet and inner sheet of 2.0mm thick and angle iron frame of size 50x50x5mm inside length not less than 90 cm(45 cm grouted in PCC) and size suitable to accommodate the following accessories, with insulated alluminium busbar 400amps capacity , 3 phase , 4 wire system, both sides openable (front and back) with locking arrangement , including cable trench duly painted with two coats of synthetic enamel paint over a coat of red oxide primer both internally and externally connecting with existing cable with lugs including internal wiring with copper cables of suitable size using lugs comprising the following accessories; Complete all as specified and as directed by Engineer-in-Charge. (a)MCCB 250 Amp four polewith thermal magnetic setting with Breaking Cap 25 KA-01 No(Incoming) (b) MCCB TPN 100 Amps 4Pwith thermal magnetic settingwith breaking cap 25KA- 02Nos (For Out Going) (c) MCCB 63 Amps (4 pole )with thermal magnetic settingwith breaking capacity 25 KA-04 Nos (For Out Going) (d) Volt Meter (digital Type (0 T0 600 Volts)-01 No (e) Ammeter (digital type) with CTs 0-300Amps)-01 No (f) Phase indication lamps LED type with holder-01 Set(Set of Three) Notes:- 1. The PanelShould be approved by CPRI.2)The rates Rate Quoted shall include for earth work and excavation for angle iron frame for foundation of panel board up to 0.50 m below GL in any type of soil and PCC 1:4:8 type D2 filling in foundation. The ground clearance of panel board shall be 0..45 M from GL to the bottom of panel board.
30Material and Labour for LT cable end joint heat shrinkable suitable for 10 Sqmm 4 core to 25 Sqmm 3.5 core cable; Complete all as specified and as directed by Engineer-in-Charge.
31Material and Labour for LT cable end joint heat shrinkable suitable for 35 Sqmm 4 core to 70 Sqmm 3.5 core cable; Complete all as specified and as directed by Engineer-in-Charge.
32Material and Labour for LT cable end joint heat shrinkable suitable for 95 Sqmm 4 core to 120 Sqmm 3.5 core cable; Complete all as specified and as directed by Engineer-in-Charge.
33Material and Labour for LT cable end joint heat shrinkable suitable for 150 Sqmm 4 core to 300 Sqmm 3.5 core cable; Complete all as specified and as directed by Engineer-in-Charge.
34Supply and install LT steel tubular pole 9.0 mtr long type 410, SP-31 complete with excavation and PCC for foundation incl coping; Complete all as specified and as directed by Engineer-in-Charge.
35Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5/4 core 10 sqmm to 35 Sqmm incl straight through joint ( Note - excavation andearth workwill be measured and paid seaparately )
36Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5 core 50 sqmm to 95 Sqmmincl straight through joint ( Note - excavation andearth workwill be measured and paid seaparately )
37Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5 core 120 sqmm to 185 Sqmmincl straight through joint ( Note - excavation andearth workwill be measured and paid seaparately )
38Material and Labour for finding UG cable fault by excavation and repairing the cable of various sizes with straight through joint and returning refiiling of trenches and removal of extra soil from site complete complete all as directed for the following :- LT cable 3.5 core 240 sqmm to 300 Sqmmincl straight through joint ( Note - excavation andearth workwill be measured and paid seaparately )
39Supply only Insulating mats as per IS-15652 of thickness 2.0 mm; Complete all as specified and as directed by Engineer-in-Charge.
40Attending breakdown complaint of OH conducrtors of any size and repairing the conductor by using additional conductor of same sizefor fixing on poles incl binding wire etc; Complete all as specified and as directed by Engineer-in-Charge. ( Note - All T&P required for attending the complaint incl safety devices will be the contractors responsibility)
41Material and Labour for dismantling of OH conductor of any size; Complete all as specified and as directed by Engineer-in-Charge.
42Material and Labour for dismantling of crossarms; Complete all as specified and as directed by Engineer-in-Charge.
43Material and Labour for dismantling of insulators; Complete all as specified and as directed by Engineer-in-Charge.
44Supply only silica gel for transformer breathers; Complete all as specified and as directed by Engineer-in-Charge.
45Material and Labour for maintanance of ACB of capacity 630 to 1000 Amps any make incl repalcement of minor parts , shunt coil , over/ under voltage coil , cleaning of contacts eith CTC and tighteing ofall connections; Complete all as specified and as directed by Engineer-in-Charge.
46Material and Labour for ACSR conductor any size; Complete all as specified and as directed by Engineer-in-Charge.
47Supply and fixing in repairs MCCB 4 pole 27 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 63/100Amps; Complete all as specified and as directed by Engineer-in-Charge.
48Supply and fixing in repairs MCCB 4 pole 27 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 125 Amps; Complete all as specified and as directed by Engineer-in-Charge.
49Supply and fixing in repairs MCCB 4 pole 27 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 160 Amps; Complete all as specified and as directed by Engineer-in-Charge.
50Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 200 Amps; Complete all as specified and as directed by Engineer-in-Charge.
51Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 250 Amps; Complete all as specified and as directed by Engineer-in-Charge.
52Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 400 Amps; Complete all as specified and as directed by Engineer-in-Charge.
53Supply and fixing in repairs MCCB 4 pole 36 KA thermal magnetic setting with ICS=100% of ICU at 415V of capacity 630 Amps; Complete all as specified and as directed by Engineer-in-Charge.
Disclaimer :