Bhabha Atomic Research Centre-BARC has published Tender For Annual Maintenance Contract With Miscellaneous Works Of Central Air Conditioning Plant And Ventilation System At Hbni Building, Anushaktinagar, Mumbai - 400 094.. Submission Date for this Tender is 21-05-2024. Ventilation Dampers Tenders in Mumbai Suburban Maharashtra. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
e433a550-c8a1-402b-b16c-31f43ee4a896.html | Tender Notice | 0 KB |
BOQ_846029.xls | Tender Document | 0 KB |
Proformaschedule.pdf.pdf | Tender Document | 0 KB |
SCHEDULE_a.pdf | Tender Document | 0 KB |
Techbid.xls.xls | Tender Document | 0 KB |
Techspecs.pdf | Tender Document | 0 KB |
Tenderdocument.pdf | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | Quarterly maintenance of water cooled screw chillers capacity of 350 TR through OEM(Original Equipment Manufacture)as per technical specification.(3 Sets x 8 Quarter) |
2 | Quarterly maintenance of centrifugal pumpsas per technical specifications.(6 Sets x 8 Quarter) |
3 | Quarterly maintenance of induced draft cooling towers capacity of 500 TR as per technical specifications.(3 Sets x 8 Quarter) |
4 | Quarterly maintenance of water softening plant capacity of 7 CMH along with pump & motor as per technical specifications.(2 Sets x 8 Quarter) |
5 | Quarterly maintenance of various capacity of AHUs as per technical specifications. (9 Sets x 8 Quarter) |
6 | Quarterly maintenance of 1.5 TR capacity fan coil unitsas per technical specifications.(266 Sets x 8 Quarter) |
7 | Quarterly maintenance of kitchen exhust blowers as per technical specifications.(3 Sets x 8 Quarter) |
8 | Quarterly maintenance of precision air conditioning units capacity of 17 TR as per technical specifications.(4 Sets x 8 Quarter) |
9 | Quarterly maintenance of precision air conditioning unit capacity of 25 TR as per technical specifications.(1 Set x 8 Quarter) |
10 | De-scaling of chillerevaporator tubefor 350 TR capacity water cooled screw chillers as per of technical specifications. |
11 | De-scaling of chiller condender tubefor 350 TR capacity water cooled screw chillers as per of technical specifications. |
12 | 2 yearly maintenance of centrifugal pumpsas per technical specifications.(6 Sets x 2 year) |
13 | 2 yearly maintenanceof various capacity of AHUsas pertechnical specifications.(9 Setsx 2 year) |
14 | Supply and installationof stem type thermometerand thermowell in SS as per tender specification |
15 | Supply and Installation of salt as per sample / suggestion by EIC as per technical specifications. |
16 | Supply and installation of 1.5 TR capacity FCU motor as per technical specifications. |
17 | Supply and installation of capacitor suitable to 1.5 TR capacity FCU as pertechnical specifications. |
18 | Supply and installation of step(speed) regulator suitable to 1.5 TR capacity FCU as per technical specifications. |
19 | Supply and installation of space heater suitable for scroll compressor of 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFSas per technical specifications. |
20 | Supplyinstallation , testing and commissioning of Scroll compressor for 12.5 TR capacity ofPrecision air conditioner ( Stulz make) as per technical specification. |
21 | Supplyinstallation , testing and commissioning of Scroll compressor for 17 TR Precision air conditioner ( Blue star make) as per technical specification. |
22 | Supplyinstallation , testing and commissioning of condenser fan with fan motor for 17 TR Precision air conditioner ( Blue star make) as per technical specification. |
23 | Supplyinstallation , testing and commissioning of condenser fan with fan motor for 12.5 TR Precision air conditioner ( Stulz make). |
24 | Supply, installation, testing & commissioning of PCB card with programming suitable to 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per technical specifications. |
25 | Supply, installation, testing & commissioning of refrigerent dryer for 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per technical specifications. |
26 | Supply, installation, testing & commissioning ofisolation valve for refrigerent dryer for 17 TR Blue Star make precision air conditioning (PAC) unit as per technical specifications. |
27 | Supply, installation, testing & commissioning of Display with key pad suitable to 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per technical specifications. |
28 | Mechanical shaft seal for Maxflow make pump of capacity 225 CMH and 40 mtr Head of WC. |
29 | Mechanical shaft seal for Maxflow make pump of capacity 300 CMH and 30 mtr Head of WC. |
30 | Mechanical shaft seal for Kirloskar make pump of capacity 225 CMH and 40 mtr Head of WC. |
31 | Mechanical shaft seal for Maxflow make pump of capacity 300 CMH and 30 mtr Head of WC. |
32 | PVC flexible canvas with 2 mm thick for Fan Coil Unit, AHU and Exhaust system as per technical specifications. |
33 | Painting of MS pipeline/supports of various sizes and painting of chilled water pipeline of various sizes with two coat of primer & two coats of synthetic enamel paint as per technical specifications. |
34 | Fabrication of MS item for supports and structures as per site reuqirement as per technical specifications. |
35 | Modification in GI ducting along with necessary fittings, supports etc as per technical specifications for 20 G (1.0 mm) |
36 | Modification in GI ducting along with necessary fittings, supports etc as per technical specifications for 22 G (0.8 mm) |
37 | Aluminium clading with 26G thick Al sheet as per technical specifications. |
38 | Supply and Installation of 25 mm thick nitrile rubber insulation as per technical specifications. |
39 | Supply, Installation, Testing and Commissioning of aluminium impeller suitable to 1.5 TR FCU installed at HBNI building as per technical specifications. |
40 | Supply, Installation, Testing and Commissioning of electronics timer as per technical specifications. |
41 | Removal of old damaged window AC and providingwindow AC of 1.5 TR as per specification |
42 | Removal of old damaged split AC and providingsplit AC of 1.5 TR as per specification |
43 | Upgradation of software of chiller control panel through OEM or authorised OEM vendor of 350 TR chiller machine ( Blue star make) as per technical specifications. |
44 | Communication connection betweenComputer andchiller machine 350 TR( Blue star make) as per technical specifications. |
45 | Supply, Installation, Testing and Commissioning of Pin type 2 way valve ½ “ PN 16 to install in supply line of FCU as per specification |
46 | Supply, Installation, Testing and Commissioning of actuator supply line of FCU as per specification |
47 | Supply, Installation, Testing and Commissioning of 5/8” sleeve insulation nitire rubber as per specification |
48 | Supply, Installation, Testing and Commissioning of ball Valve 25 mmdia in FCU Connection line |
49 | Supply, Installation, Testing and Commissioning of M.S. Fan motor stand for FCU as per sample |
50 | Supply, Installation, Testing and Commissioning of M.S. Fan motorforas per sample |
51 | Supply, installation, testing & commissioning of temperature sensor MCS-T100-40 suitable to blue star make water cooled screw chiller capacity of 350 TR as per technical specifications. |
52 | Supply, installation, testing & commissioningof Chiller plant no.33 phase motor overload relay model 3UA61 40-3J 110-135A |
53 | Supply, installation, testing & commissioningof flow switch forChiller plant 350 TR as per specification |
54 | Supply and Installation of HDPE Filter of FCU as per specification. |
55 | Supply and Installation of Purging valve 25 mm dia GM gate valve. |
56 | Weekly checking of water quality of Cooling tower water, make up water and chilled water. |