| 1 | Supply & laying XLPE insulated, armoured and PVC sheathed heavy duty electric cable with aluminum conductor, 1100 Volts grade laid in tranches/passing through pipes/ducts including testing of following size and cross sectional area complete all as specified and directed.Note - Rate is inclusive of cable lugs & cable gland. |
| 2 | 120 Sqmm, 3.5 Core |
| 3 | 95 Sqmm, 3.5 Core |
| 4 | 50 Sqmm, 3.5 Core |
| 5 | 25 Sqmm, 4 Core |
| 6 | 16 Sqmm, 4 Core |
| 7 | 10 Sqmm, 4 Core |
| 8 | M&L for Boring of holes under road, pavement, hard standing manually including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 9 | M&L Plain Cement concrete 1:2:4 type B-2 using 40mm grade stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | S&F time switches astro type (Having longitude and latitude of Indian cities in memory), 250 Volts, single phase of 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed. |
| 11 | Supply, installation, testing and commissioning CPRI APPROVED factoryfabricated, out door type, LT Feeder Pillar Box of size not less then 1.5m width x 1.2m heigth x 0.6m depth, made out of 3.15mm thick CRCA sheetwith projected globe roof for rain water protection dust and vermin proof,double door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volts, 3 Phase, 4 Wire system, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc and embeddedwith 50 x 50 x 6 mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm graded stone aggregate) and Testing after Installation complete all as specified and comprising of the following :– |
| 12 | (a)Aluminum bus bar 600 Amps - 01 Set |
| 13 | Incoming :- |
| 14 | (a) MCCB 320 Amps, 35 KA,4 Pole, thermal magnetic release, Ics=100% Icu- 1 Nos (I/C) |
| 15 | Outgoing :- |
| 16 | (a) MCCB 250 Amps, 35 KA,3 Pole, thermal magnetic release, Ics=100% Icu- 2 Nos (O/G) |
| 17 | (b) MCCB 200 Amps, 35 KA,3 Pole, thermal magnetic release, Ics=100% Icu- 2 Nos (O/G)(01 Nos Standby) |
| 18 | (c) MCCB 63 Amps, 25 KA, 3 Pole, thermal magnetic release, Ics=100% Icu - 2 Nos (O/G) |
| 19 | (d) Ammeter Class-1, digital panel mounting type 96mm x 96mmincluding CT 800 x 5 Amps, 3 Nos & selector switch. |
| 20 | (e) Voltmeter Class-1, digital panel mounting type 96mm x 96mm & selector switch |
| 21 | (f)LED Type indicator lamp - 1 set (set of three for R, Y, B) |
| 22 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground levelconnecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection ofGI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B-1 with angle iron frameCI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal (for LT Panels).Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor. |
| 23 | Dismantling carefully the existing unserviceable LT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge. |
| 24 | Dismantling of unserviceable insulator of any size and type complete from itsposition and removing complete all as specified and directedby Engr-in-Charge. |
| 25 | Dismantling of unserviceable stay assembly carefully includingstay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site complete all as specified and directed.directed. |
| 26 | Dismantling of unserviceable existing cross arms by means made from channels, angles, unserviceable FI clamps, nuts, bolts etc from OH line and removing complete all as specified and directed. |
| 27 | S&Fin repairs LED street light fitting 35 Watts, 230 Volts, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 28 | Supply, fabrication and installation of GI pipe bracket made of \"medium Grade\" tubing of 32 mm dia, duly bend by hot forgoing after filling of sand, length 1.20 m includingpair of MS flat strip clamps 30mmx5mm with GI bolts, nuts and washer complete all as specified and directed |
| 29 | Dismantling unserviceable main switch/kitkat DBs/MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces complete all as specified and directed. |
| 30 | S&F sheet metal enclosure for DB’s TPN 4 way, vertical type with 200 Amps rated bus-bar 415 Volts double door with magnetic locking system, IP-43-IK09 protection grade complete all as specified and directed. |
| 31 | S&F sheet metal enclosure for DB’s SPN 8 way, vertical type with 200 Amps rated bus-bar 240 Volts double door with magnetic locking system, IP-43-IK09 protection grade complete all as specified and directed. |
| 32 | S&F in repairs MCCB 125 Amps, 415 Volts, 16KA, 3 Pole, fixed type complete all as specified and directed. |
| 33 | S&F in repairs MCCB 100 Amps, 415 Volts, 16KA, 3 Pole, fixed type complete all as specified and directed. |
| 34 | S&F in repairs MCCB TPN 63 Amps, 415 Volts, 16KA, 4 Pole complete all as specified and directed. |
| 35 | S&F MCB SPN 32 Amps, \"C\" series, breaking capacity 10 KA of rating complete all as specified and directed. |
| 36 | S&F MCB SPN 40-63 Amps, \"C\" series, breaking capacity 10 KA of rating complete all as specified and directed. |
| 37 | S&F MCB SP 6-32 Amps, \"C\" series, breaking capacity 10 KA of rating complete all as specified and directed. |
| 38 | Excavation in trenches in any type of soil n.exc 1.5m wide and n.exc 1.50m deep and getting out complete all as specified and directed. |
| 39 | Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc 25cm complete all as specified and directed by Engr-in-Charge. |
| 40 | Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 41 | Supply unwashed sand cushioning to under ground cable provided with a layer of 8 cm deepbefore laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed.Note : Maesurement shall be done after puning down of sand. |
| 42 | Supply and laying reinforced precast concrete cable cover, class LV, type-I, size 250 mm x 150 mm x 40mm complete all as specified and directed by Engr-in-Charge. |
| 43 | M&L for Seel tubing GI \"light grade\" of size 50 mm dia for cable protection passing under road /floor/Pole or for fixing to poles complete all as specified and as directed. |
| 44 | Supply, laying and testing of ductile iron pipe with spigot and socket ends, Class \"K-9\", 150 mm bore complete all as specified and directed. |
| 45 | Supply, laying and testing of ductile iron pipe with spigot and socket ends, Class \"K-9\", 100 mm bore complete all as specified and directed. |
| 46 | M&L for ductile iron fittings, Class \"K-9\" complete all as specified and directed. |
| 47 | M&L forSteel Water Tubes, \"medium grade\", galvanised, 80 mm bore with all fitting, laid in trenches including testing complete all as specified and directed. |
| 48 | M&L forSteel Water Tubes, \"medium grade\", galvanised, 40 mm bore with all fitting, laid in trenches including testing complete all as specified and directed. |
| 49 | M&L forSteel Water Tubes, \"medium grade\", galvanised, 25 mm bore with all fitting, laid in trenches including testing complete all as specified and directed. |
| 50 | M&L forSteel Water Tubes, \"medium grade\", galvanised, 20 mm bore with all fitting, laid in trenches including testing complete all as specified and directed. |
| 51 | M&L forSteel Water Tubes, \"medium grade\", galvanised, 15 mm bore with all fitting, laid in trenches including testing complete all as specified and directed. |
| 52 | Taking up cast iron water mains 150 mm (including all fittings), with spigot and socket ends and lead joints including bruning out and recovering lead complete all as specified and directed. |
| 53 | Taking up cast iron water mains 100 mm (including all fittings), with spigot and socket ends and lead joints including bruning out and recovering lead complete all as specified and directed. |
| 54 | Taking up or down steel tubing 15 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 55 | Taking up or down steel tubing 20 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 56 | Taking up or down steel tubing 25 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 57 | Taking up or down steel tubing 40/50 mm bore and connections, including cleaning for refixing or removal to store complete all as specified and directed. |
| 58 | S&F Sluice Valves Class PN 1.6, 150 mm dia complete all as specified and directed. |
| 59 | S&F Sluice Valves Class PN 1.6, 100 mm dia complete all as specified and directed. |
| 60 | S&F Non Return Sluice Valve 150 mm dia complete all as specified and directed. |
| 61 | S&F Non Return Sluice Valve 100 mm dia complete all as specified and directed. |
| 62 | S&F DI single Chamber duojet Air Release Valves, 150 mm dia and fixing in DI pipe line complete all as specified and directed. |
| 63 | S&F DI single Chamber duojet Air Release Valves, 100 mm dia and fixing in DI pipe line complete all as specified and directed. |
| 64 | S&F Stop Valve, cast copper alloy, fancy type, chromium plated, screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, for pipe 15 mm bore complete all as specified and directed. |
| 65 | S&F Stop Valve, cast copper alloy, fancy type, chromium plated, screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, for pipe 20 mm bore complete all as specified and directed. |
| 66 | S&F Stop Valve, cast copper alloy, fancy type, chromium plated, screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, for pipe 25 mm bore complete all as specified and directed. |
| 67 | S&F Stop Valve, cast copper alloy, fancy type, chromium plated, screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, for pipe 40 mm bore complete all as specified and directed. |
| 68 | S&F Stop Valve, cast copper alloy, fancy type, chromium plated, screw down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, for pipe 50 mm bore complete all as specified and directed. |
| 69 | Taking down of old stop valve/NRV/Air Releas Valve of any size/capacity complete all as specified and directed. |
| 70 | Schedule of credit amount of Rs. 1,93,781.00 to be deducted during AOC. |