}

Bids Are Invited For Custom Bid For Services - Soil Investigation Of Boring 150 Mm Dia At Any Kind Of Existing Soil Strata At Different Location With Approved Means Of Drilling / Refusal Strata Up To 15 Mtr ( If Required , Gurdaspur-Punjab

Indian Army-IA has published Bids Are Invited For Custom Bid For Services - Soil Investigation Of Boring 150 Mm Dia At Any Kind Of Existing Soil Strata At Different Location With Approved Means Of Drilling / Refusal Strata Up To 15 Mtr ( If Required . Submission Date for this Tender is 20-05-2024. Drilling Work Tenders in Gurdaspur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

43258476
Bids Are Invited For Custom Bid For Services - Soil Investigation Of Boring 150 Mm Dia At Any Kind Of Existing Soil Strata At Different Location With Approved Means Of Drilling / Refusal Strata Up To 15 Mtr ( If Required
Open Tender
Indian
Punjab
Gurdaspur
20-05-2024

Tender Details

Bids Are Invited For Custom Bid For Services - Soil Investigation Of Boring 150 Mm Dia At Any Kind Of Existing Soil Strata At Different Location With Approved Means Of Drilling / Refusal Strata Up To 15 Mtr ( If Required More Than 10 Mtr ) Depth , Whichever Is Earlier And Find Out The Sbc As Per Follwoing Test / Recommendations 22 ( Bore ) ( I ) Carrying Out Standard Penetration Test ( Spt ) As Per Is : 2131-1981 Includingcollection Of Disturbed Soil Samples In Bore Holes At Varying 1.5Mtr Depth Or Any Changes Of Strata And Submit The Report With All Requisite Data. ( Ii ) Conducting Necessary Test As Per Relevant Is Codes / Sp 36 On All Collected Samples With Including The Dtermination Of Following:- ( Aa ) Alterberg Limits, Natural Moisture Content, Wet And Dry Desnsity, Soil Particle Size Distribution, Bore Log Data Using Sleeve, Hunrometer Analysis, Tri-Axial Shear Test-C & Ph Value Determination, Shrinkage Limit, Consolidation Test, Specific Gravity Test, Calculation Of Sbc, Chemical Analysis Of Soil To Determine Ph Value, Sulphate And Chlorides Content And Per Relevant Is Code. ( Iii ) Evaluation Of Liquefaction Potential As Per Annex F Of 1893 ( Part-I ) 2016. ( Iv ) Recommendation Of Type Of Fdn Viz Shallow, Deep / Pile / Raft / Required And Minimum Depth Of Foundation Considering Soil Strata. V ) Assessment / Recommendation Of Sbc For Shallow Foundaiton Isolated Combined For Various Sizes Of Footing Upto 4M Size At Depth Of 1.0, 1.5, -2.0, 2.5M Depth. ( Vi ) Submission Of Report As Per Relevant Is Code Including Supported Calculation In Triplicate. ( Vi ) Rl Of Natural Ground Level Also Mentioned At Particular Bore Holes Location So That Exact Depth Of Foundaiton May Be Worked Out. ( Aa ) Nos Of Bore Hole For Stop Butt-2X1=02 Nos. ( Ab ) Nos Of Bore Hole For Baffel Wall-1X10=10Nos. ( Ac ) Nos Of Bore Hole For Side Wall-1X10=10 Nos. ( Ad ) Total =22 Nos Note : It Will Be Responsibility Of The Contractor For Layout Of The Buildings On Ground For Finalization Of Locations For The Bore Holes As Per The Drawings Provided By The Mes Including Clearing Of Surface I.E. Grass Cutting Etc If Required. Soil Investigation Of Boring 150 Mm Dia At Any Kind Of Existing Soil Strata At Different Location With Approved Means Of Drilling / Refusal Strata Up To 10 Mtr ( If Required More Than 6 Mtr ) Depth , Whichever Is Earlier And Find Out The Sbc As Per Follwoing Test / Recommendations. @ ) Carrying Out Standard Penetration Test ( Spt ) As Per Is : 2131-1981 Including Collection Of Disturbed Soil Samples In Bore Holes At Varying 1.5Mtr Depth Or Any Changes Of Strata And Submit The Report With All Requisite Data. ( Ii ) Conducting Necessary Test As Per Relevant Is Codes / Sp 36 On All Collected Samples With Including The Dtermination Of Following:- ( Aa ) Alterberg Limits, Natural Moisture Content, Wet And Dry Desnsity, Soil Particle Size Distribution, Bore Log Data Using Sleeve, Hunrometer Analysis, Tri-Axial Shear Test-C & Phi Value Determination, Shrinkage Limit, Consolidation Test, Specific Gravity Test, Calculation Of Sbc, Chemical Analysis Of Soil To Determine Ph Value, Sulphate And Chlorides Content And Per Relevant Is Code. ( Iii ) Evaluation Of Liquefaction Potential As Per Annex F Of 1893 ( Part-L ) 2016. ( Iv ) Recommendation Of Type Of Fdn Viz Shallow, Deep / Pile / Raft / Required And Minimum Depth Of Foundation Considering Soil Strata. V ) Assessment / Recommendation Of Sbc For Shallow Foundaiton Isolated Combined For Various Sizes Of Footing Upto 4M Size At Depth Of 1.0, 1.5, 2.0, 2.5M- Total Quantity :

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail