Tender For Increasing Capacity Of 33/11 Kv Sub Station Diyara From 5+10 Mva To 2X10 Mva Distt Sultanpur, sultanpur-Uttar Pradesh

Madhyanchal Vidut Vitran Nigam Limited has published Tender For Increasing Capacity Of 33/11 Kv Sub Station Diyara From 5+10 Mva To 2X10 Mva Distt Sultanpur. Submission Date for this Tender is 17-05-2024. Transmission Line Tenders in sultanpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43257988
Corrigendum : Tender For Increasing Capacity Of 33/11 Kv Sub Station Diyara From 5+10 Mva To 2X10 Mva Distt Sultanpur
Open Tender
Indian
Uttar Pradesh
sultanpur
17-05-2024

Tender Details

Tender For Increasing Capacity Of 33 / 11 Kv Sub Station Diyara From 5+10 Mva To 2X10 Mva Distt Sultanpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-May-2024 Date E Date 06-05-2024
2 06-May-2024 Date Ex Date 08-05-2024
3 08-May-2024 Date Extension Date 10-05-2024
4 10-May-2024 Date Exten Date 11-05-2024
5 11-May-2024 66date Date 13-05-2024
6 13-May-2024 70Date Date 15-05-2024
7 15-May-2024 78date Date 17-05-2024

Key Value

Document Fees
INR 1180 /-
EMD
INR 4000.0 /-
Tender Value
INR 3.97 Lakhs /-

BOQ Items

Name of Work: INCREASING CAPACITY OF 33/11 KV SUB STATION DIYARA FROM 5+10 MVA TO 2X10 MVA DISTT SULTANPUR
Sl. No. Item Description
1SafeLoading, Carriage and then safeunloading of the following material from Store Centres Under the jurisdiction of EEESD Ayodhaya to dump site proper stacking.
233 KV Bus Isolator
333 KV Post Insulator
4Double T/F control pannel
511 KV Incoming switch gear 600/300/5A, 350 MVA
611 KV Out going switch gear 200/100/5A0250MVA
711 KV 3 Core Cable 3x300 mm XLPE
811 KV cable jointing kit indoor 3x300 sq.mm. XLPE
911 KV cable jointing kit outdoor 3x300 sq.mm. XLPE
1024 Volt Battery Bank & Battery charger with cabinet
11ACSR Dog Conductor
12M.S. Channel 125x65 (for Structures)
13M.S. Angle 75x75x8 (for Structures)
14Opening of all the 33 KV Jumpers, Neutral connections, cable connections, opening of earth strips and then shifting of 5 MVA T/F from plinth to Other side(temrorary plinth) in yard.
15Shifting 33 KV Jumpers, from actual position to the new shifted place along with 11 KV cable and other accessories for maintaining & restoring the S/S supply
16Plinth of 10 MVA, 33/11 KV T/Fs Expansion and major repairing of existing 5 MVA T/F plinth of less size to 3.5 Mtr x 3.5 Mtr suitable for 10 MVA T/F by RCC work of ratio 1:2:4 using M.S. Bar 10 mm dia (TOR) inreinforcement including cutting, bending and binding in required shape complete in all respect and shall be plastered/Finished on top and side of the Plinth.
17H.T. Cable Laying Laying & dressing of 11 KV, 3x300 and 3X185 Sq.mm XLPE cable underground from 10 MVA T/F to 11 KV incoming switchgear in the trench 450mm wide, 900mm deep, providing 150mm fine sand cushion bench and 150mm fine sand cushion above the cable. The cable shall be duly protected by 1st class bricks two either side and third on top of the cables, laid in series one after the other, the work includes supplying offine sand and bricks, refillingand rammingof the left out soil, closing the trench and leveling. Spare cable shall be left and buried in the trench in the safe of rings at both ends. Cable laying work includes unrolling, cutting, meggering and sealing both end of the cable.(All the material will be supplied by the contractor)
18Erection and Installation of 33/11 KV10 MVA Transformer Dragging of 33/11KV 10 MVA T/F from Dump site to road site and shifting of the T/F from road site to new constructed plinth distance about 150mtr ,along with loading, unloading and carriage, fixing and fitting of all the accessiories and filling of T/F oil to the desired level and insuring that there is no leakage. Erection and installation of 33/11 Kv, 10 MVA Transformer in a leveled position on the plinth.
19Installation of Post Insulator Installation of06 nos. post insulator on the post insulator structure . The work includes fabrication for proper fixing if required.
20Installation of Switchgears in Control room Shifting carefully and safely 11 Kv incomingSwitchgear, 11 KV outgoing Switchgear and 11 KV Bus Coupler from out side of the switch gear room, as per direction of Engineer Incharge, Placing and fixing of switchgear on foundation providing nuts & bolt of proper size in proper position and alignment and mountting of P.T. on incoming S/G. By replacing the old and existing switchgear from sgr room to storage location ofSubstaion.
21Installation of Bus Isolators Assembling and installation of Bus isolator on the Isolator structure , adjusting of opening mechanism in proper alignment so as to ensured smooth operation of the same. In case of line Isolator proper operation of earth links shall also be ensured. The work includes fabrication for proper fixing if required.
22Installation of Heat Shrinkable Type cable jointing kits indoor and O/D end Termination and S/T Joint suitable for 11KV XLPE cable confirming to IS ESI-09-13-IS-13573 of 1992 amendment I&II VDE-0278 of latest version there of if any.
23Cable stand Structure Fabrication & erection of 11 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip (m.s flat) 50x6 mm of size 200 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs and provideing clamps , post/ pin insulator for holding cable. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
24Neutral stand Fabrication and grouting of M.S Channel 125x65 mm L shape & in proper size and allignment to provide support for the two separate earthing strips for pwer T/F neutral including supply & fixing of two No.Flexible copper bonds for neutral earthing. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
25Supply & Laying of 6x2.5 sq.mm. armoured control cable from power T/F to controle board in the ground as per RESPO Norm with proper connection VCB, CT & Control Pannel with T/F to battery and battrey charger, Bucholz Relay, low higher and winding temperture protection alarm etc with including all the civil material. (All the material will be supplied by the contractor)
26Special Earthing by way of boring and lowering of "B" class G.I. pipe 50 mm Dia 20mtr longfrom ground upto the water level andit will be connected to the G.I. strip 50X6 mm ( Providing & laying of G.S. strip including cutting, welding, bending etc.) for equipments(L.A,T/F,C.T., VCB.etc). The earth strip will be welded to the G.I. Pipe. The work also includes Cap & Clamps for pouring water, the cost of all material with all labour & T&P etc. Complete in all respect. (All the material will be supplied by the contractor)
27Commissioning of 10 MVA T/F and its eqipments installed in switchyards and 11 KV Incoming and Outgoing Pannels complete in all respect upto energising
28Painting ofAll switchyard Sub Station Structures (Old+New+fencing) with one coat of ready mixed primer and 2 coats of AL.Paint of good quality including cost of material, Labour and T&P complete in all respect.
29Digging and locating the earth mat and outdoor Structures earthing by G.I Flat. 50X6 mm the job include cutting, bending. (All the material will be supplied by the contractor.)
30Supply and fixing of P.G clamp for dog and connector
31providing of Hand gloves As per IS 4770 and tested potential 33 Kv.
32Installation of 24 Volt Battery(210 AH) & Battery charger with cabinet. With its proper connection.
33Shifting carefully and installation ofSingle/double Transformer Control pannel in control roomand earthing of pannel on side and do proper connection.
34Fixing and making Bus Bar connection in between I/C and O/Gswitchgears after cleaning and tapping with H.T. tape, Empire tape and PVC tape properly providing and fixing of 6mm thick bakelite seperators and plugging of all opening and holes with plastic compound. complete work including cost of all materialStrictly to the satisfaction of site incharge.
3533 KV Bay Bus Bar & Stringing. Stringing of 33KV Bay Bus Bar by using and laying of ACSR Dog Conductor including making Vertical/Horizontal (Y-shape) jumperconnection through PG clamps and connecting all the equipments ( Bus isolator, P.I. , C.T. , VCB, L.A & T/F) with each other through connecting clamps.(All the material will be supplied by the contractor)
36Construction of toe wall around the 33KV switchyard in size(5+5) mtr using first class bricks, local river sand and brick ballast which includes the following works( Including cost of 1st class brick, brick ballast sand/core sand cement etc.) 1.Excavation of earth in foundation 2.Cement concrete in foundation in 1:5:10 ratio 3.1st class brick work in 1:6 ratio 4.Plaster work 1:6 ratio 5.CC 1:2:4 for grouting mid angles post for fencing
37Shifting carefully and installation ofSingle/double Transformer Control pannel in control roomand its proper connection. By replacing the old and existing control panel from sgr room to storage location ofSubstaion
38Providing of Rubber matting one side chequered and other side plane size 1900x800x12 mm
39construction of newfencing around the switchyard with gate (5+5) mtr by using proper and suitable size SWG wire M.S angle etc.(The fencing should have same peripheral size of toe wall All materials will be supplied by the contractor
Disclaimer :