Tender For The Work Of Replacement Of Damaged Vcbs, Relay Revitalization And Strengthening Of 33/11 Kv Substations Under Edd-Iind, Chandpur In Bp 2024-25, Various Works Related To Strengthening Of 33/11 Kv Sub-Stations- Work To Be Done Through External Ag, bijnor-Uttar Pradesh

Paschimanchal Vidyut Vitran Nigam Limited has published Tender For The Work Of Replacement Of Damaged Vcbs, Relay Revitalization And Strengthening Of 33/11 Kv Substations Under Edd-Iind, Chandpur In Bp 2024-25, Various Works Related To Strengthening Of 33/11 Kv Sub-Stations- Work To Be Done Through External Ag. Submission Date for this Tender is 06-05-2024. Power Distribution Work Tenders in bijnor Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

43257848
Corrigendum : Tender For The Work Of Replacement Of Damaged Vcbs, Relay Revitalization And Strengthening Of 33/11 Kv Substations Under Edd-Iind, Chandpur In Bp 2024-25, Various Works Related To Strengthening Of 33/11 Kv Sub-Stations- Work To Be Done Through External Ag
Open Tender
Indian
Uttar Pradesh
bijnor
06-05-2024

Tender Details

Tender For The Work Of Replacement Of Damaged Vcbs, Relay Revitalization And Strengthening Of 33 / 11 Kv Substations Under Edd-Iind, Chandpur In Bp 2024-25, Various Works Related To Strengthening Of 33 / 11 Kv Sub-Stations- Work To Be Done Through External Agency In The Business Plan 2024-25 Under The Area Of ​​Electricity Distribution Division-Ii, Chandpur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-May-2024 DATE EXTEND2 Date 06-05-2024

Key Value

Document Fees
INR 3540 /-
EMD
INR 14000.0 /-
Tender Value
INR 13.90 Lakhs /-

BOQ Items

Name of Work:??????? ????? ????-???????, ???????? ?? ??????????? ?????? ????? 2024-25 ??? 33/11 ???? ??????????? ?? ????????? ???????? ??????? ??????? ?? ????? ??????? ?? ?????? ?? ????? ???? ?? ??????
Sl. No. Item Description
1Safe carriage of following material from store center PVVNL to site of work with loading and unloading at both ends.
2300 mmsq Cable jointing kit
3120 mmsq Cable jointing kit
4185 mmsq Cable jointing kit
524V Battery Charger
6Battery Set.
733KV post insulator.
833kv CT 200/100/1A T.
9Vaccume interrupter of 11kv VCB.
10Supply of following material including freight and insurance charges as per Resspo Norms.
1133KV Isolator Jaw.
1233KV Isolator blade
13O/C, E/F Relay having following specification Numerical micro control Based 4 Pole, 3 O/C, + 1 E/F, IDMT Protection Relay, Auxiliary Voltage 18- 250 V AC/DC CT Secondary 1/5 Amp. Auxiliary Supply 18- 250 V AC/DC with +/- 20 % tolerance Instantaneous O/C Plug setting 5 % to 250 % in steps of 1% Instantaneous E/F Plug setting 5 % to 250 % in steps of 1% High Set O/C Setting 50% to 3000% in steps of 1 % High Set E/F Setting 50% to 3000% in steps of 1 % Time multiplier setting for O/C & E/F 0.01 to 1.5 steps of 0.01. Time delay for High Set O/C & E/F 0.00 Sec to 99.9 sec in steps of 0.1 Sec.
1411kv Tripping/closing Coil.
15L.T. Lugs (Nuts/bolts type)
16Installation of the following material as per RESPO manual and direction of the Engineer Incharge (complete in all respect)
17Erection of 300 mmsq Cable jointing kit in place of Defective.
18Erection of 120 mmsq Cable jointing kit in place of Defective.
19Erection of 185 mmsq Cable jointing kit in place of Defective.
20Erection of 24V Battery Charger in place of Defective.
21Erection ofBattery Set in place of Defective.
22Erection of 33KV post insulator in place of Defective.
23Erection of 33kv CT 200/100/1A in place of Defective.
24Erection ofVaccume interrupter of 11kv VCB in place of Defective.
25Erection of 33KV Isolator Jaw in place of Defective.
26Erection of 33KV Isolator blade in place of Defective.
27Erection ofO/C, E/F Relay having following specification Numerical micro control Based 4 Pole, 3 O/C, + 1 E/F, IDMT Protection Relay, Auxiliary Voltage 18- 250 V AC/DC CT Secondary 1/5 Amp., Auxiliary Supply 18- 250 V AC/DC with +/- 20 % tolerance, Instantaneous O/C Plug setting 5 % to 250 % in steps of 1% , Instantaneous E/F Plug setting 5 % to 250 % in steps of 1%, High Set O/C Setting 50% to 3000% in steps of 1 %, High Set E/F Setting 50% to 3000% in steps of 1 %, Time multiplier setting for O/C & E/F 0.01 to 1.5 steps of 0.01., Time delay for High Set O/C & E/F 0.00 Sec to 99.9 sec in steps of 0.1 Sec. in place of Defective
28Erection of 11kv Tripping/closing Coilin place of Defective.
29Erection ofL.T. Lugs (Nuts/bolts type)in place of Defective.
30Earthing of Control and Relay panel with 50x6 mm G.I. Stripsin place of Defective.
31Erection ofPainting of rusted structures, equipment earthing strips, panel etcin place of Defective.
32Erection of Attending leakage of 5 MVA Power Transformer by replacement + Defective Gadjectin place of Defective.
33Erection of Attending leakage of 10 MVA Power Transformer by replacement + Defective Gadject in place of Defective.
34Erection of Delta earthing of 5/10 MVA Power Transformerin place of Defective.
35Dismentallingand Back Cartage of following MaterialFrom Work site to Store Centre Bijnor with Loading & Unloading at both ends.
3624V Battery Charger (Scrap)
37Battery Set(Scrap)
3833kv CT 200/100/1A (Scrap)