Paschimanchal Vidyut Vitran Nigam Limited has published Tender For 9 Work In System Strengthening In Dpr 33 Crore Sl No 1 2 3 4 5 6 7 8 9 Under Eudd 1 Noida, Details Of Work And Quantity Against E-Tender No. 144/Eudc-I/2023-24/Noida (Works) For Carrying Out The 9 Nos. Work In Head System Strengthening / Replac. Submission Date for this Tender is 09-05-2024. Electrification Work Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-May-2024 | DATE EXTENSION 1 | Date | 09-05-2024 |
Sl. No. | Item Description |
1 | Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : - |
2 | 11 KV Comp. Poly. Pin Insulator with pin. |
3 | 11 KV Disc Insulator T&C type 4500 kg. |
4 | 11 KV Disc fitting. |
5 | 11 KV D.O. Fuse Set. |
6 | MS channel 125x65x1300mm (T-off). |
7 | Earthing Complete |
8 | ST Pole 13 Mtr. long SP-70 |
9 | Providing & fixing of following material of standard make / best quality for complete the work of pole structure at HT / LT line as per RESPO norms by the contractor at his own cost : - |
10 | Clamp with nut & bolts for ST Pole |
11 | F-Bracket with nut & bolts |
12 | Stone Pad 300x300x75mm. |
13 | LT Shackle Insulator. |
14 | Al. crimping lug 70 Sq.mm. for connection on fuse set T/Fs. |
15 | Al. lug ling barrel, off size (LS) 240 Sq.mm. |
16 | Removal of conductor from both side spans of damaged pole and removal of H.T/L.T. line accessories from damaged pole. |
17 | Diggingof pit of damaged pole in Pakka road (Hard soil) with the help of road cutter/digging machine, Tractor etc. for dismantling the pole. |
18 | Erection of S.T. pole 11 Mtr. including fitting of all reqired accessories of HT/LT line as per RESPO schedule. |
19 | Grouting & concreting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects. |
20 | Construction of Plinth in size 450x450x300 mm of each (0.880 Cu.m) pole above the ground level(In ratio of 1:3:6 in Cement, sand and Brick Ballast) as per RESPO schedule Complete in all respects. |
21 | Excavation of earth and driving of M.S. earthing rod of size 20x2500 mm in earth and jointing through G.I wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts etc. as per RESPO schedule Complete in all respects. |
22 | Re-laying and resagging of conductor in both side spans of erected pole in H.T/L.T line. |
23 | Fabrication & fixing of MS channel 125x65x1300mm (T-off) in all respects. |
24 | Fixing of 11 KV D.O. Fuse Set. |
25 | REPLACEMENT OF OLD & DAMAGED LT FEEDER PILLER OF VARIOUS SECTORS AS PER FOLLOWING :- |
26 | Supply of new L.T. Feeder Pillar as per following specification with all relevant certificate :- 1) LT Feeder Pillar Box (Branch Distribution Pannel) shall be of 14 SWG HR sheet, having (1) doors in front of 14 SWG HR sheet. Doors should have proper locking arrangements with providing crome locks of standard make. It should have a canopy on top in order to prevent it from water ingress in rains. The doors of box should be welded with robust quality hinges and PVC GaskEt with provision of 3 hinges on each door and handle on each door with PVC Gasket. The periphery of door of the LT Feeder Pillar Box (Branch Distribution Pannel) shall be provided with lining of rubber/ PVC to prevent entry of rain, insects, lizards, rats etc. so as to make it vermin proof. 2) The dimension of Feeder Pillar Box (Branch Distribution Pannel) 4(Height) X 2.5(Width) X 2(Depth) Feet (With Canopy). 3) 04 Nos. Bus Bar insulation coated fo size 600x50x10mm. made of aluminum for red, yellow, blue & neutral phases suitable for 400 Amp. 4)01 No. MCCB of 800 Amp. of L&T / Havell’s / ABB make for disconnecting of Supply. 5) 24 Nos. KIT KAT Fuse of 415V, 100 Amp. each capacity tested as per IS shall be provided with 8 Nos. on each phase so as to cater to 8Nos. 3 Phase connections of conusmer. 6) Aluminum crimping lugs of size 400 / 240 / 120 / 95 / 70Sq.mm. and proper size thimbles shall be provided for safe termination of incomer as well as individual service cable as per qty. requirement. 7) Bakelite sheet shall be provided on the base of channel meant for mounting the Kit Kats. 8) All nuts, bolts & washers used shall be electro galvanized. 9)The height of erected feeder pillar box (Branch Distribution Pannel) approx. 2feet from the earth on powder coatingbase of angle iron size 40x40x5mm frame with 04 nos. legs of 3 feet each (1 feet grout of angle on earth bottam, 1.6 feet grout in plinth and 6 inch gap in pannel base and plinth) 10) Grouting & Plinth of Feeder Pillar Box(Branch Distribution Pannel) as per site requirement complete in all respects. 11)The panel case consisting of door and roof (canopy) shall be powder coated with chemical process (weather proof) of Off-white color (Or as per direction) both inside and outside. Before painting, the sun faces shall be thoroughly cleaned from dust, grease and rust. Ientification no. shall be written as per direction. 12) Sundry item. |
27 | Disconncetion of all Consumer connection from pannel as per requirement. |
28 | Reconncetion of all Consumer connection from pannel after replacement as per requirement. |
29 | Installation of abovenew L.T. Feeder Pillar in place of damaged L.T. Feeder Pillar with grouting, plinth and required items complete in all respect. |
30 | Dismantling of damaged OLD Feeder Pannel Box from earth on work site. |
31 | Carriage of above dismantled Pannel from works site to JE store / central store & proper stacking with loading & unloading. |
32 | Providing and installation ofLT ACB630 Amp. with cabinet / structure (L&T, HPL, Schneider, ABB, Hevell"s, PVVNL approved make) as per following specification with all relevant certificate :- |
33 | 630 amp. 03 pole fixed manual ACB. |
34 | Red/yellow/blue light indication |
35 | ON & OFF Indication |
36 | Amp., Voltmeter& energy meter digital |
37 | Metering C.T 630/5A, |
38 | Panel fabrication of size 1250mm x 900mm x 600 mmmade of M.S sheet 14 gauge with powder coating with panel lock and key arrangement.(two nos). and additional locking arrangement seprately including providing hut type shape as per drg. |
39 | Fabrication ofaluminium bus-bar for each phases |
40 | Incoming size 425 mm x 50mmx12 mm (twin) |
41 | Out going size 720 mm x 50mm x 12 mm(twin) |
42 | Neutral size 900mmx50mmx12 mm. |
43 | Fabrication of pannel stand made of M.S Angle of size 900mm x 600mm x 500 mm as per drg. |
44 | Assembly of above ACB, Indicators, Meters, Metering CT & bus bar arrangment in the panel, fitting the panel on Stand with nut and boltswith wiringetc. & grouting inratio 1:4:8 with cement, coarse sand and brick blast. |
45 | Providing and fixing of aluminium bus bar of size 300mmx60mmx12 mm on L.T side of T/F. |
46 | Making all connections with ACB & Distribution T/F and commissioning the ACB complete in all respect. |
47 | WORK OF PROVIDING AND FIXING OF 20 NOS. NEW WIREMESH FENCING OF 11/0.4 KV L.T. SUB-STATION INSTALLED AT ABOVE PLACE AS PER FOLLOWING(All Material provided by contractor for above work.) :- |
48 | 1. Frames of size 12"X15"x6" for each fencing of LT Sub-stations. (All Material provided by contractor for above work.) 2. The fencing shall be fabricated out of MS angle iron of size 40x40x5 mm having 2 Nos. legs of 45 Cm. long in each frame duly welded and fixed with wire mesh of size 75mm 25mm, 10 SWG within the frame, pressed under MS flat of size 25x5 mm inside the angle iron on all four sides with the help of duly Welded along with cross bracing of 25x5 mm MS flat on every frame will be grouted in 1:2:4 cement mortar with cement, coarse sand 20 mm gauge stone ballast. 3. Every frame after Fabrication will be painted with one coat of red oxide and two coats of Green synthetic enamel paint of approved make after proper cleaning. 4. The above mentioned frame will be jointed with each other with 70 mm long MS flat of size 25x5mm by first class welding as per site. 5. Fabrication and providing of wire mesh fencing frame for gate of size 4’x6’. Fabricated as per above specifications with proper locking arrangement. |
49 | Construction of boundry / toe wall in bottom of fencing in brick work cement mortar 1:6 (1 cement : 6 coarse sand) for link in the size of 0.22mx0.60m (0.30m in earth, 0.30m above ground level) including plaster in cement mortar 1:4 and finishing with water proof cement paint. (Approx construction 12 Mtrs. boundry / toe wall for each fencing of LT Sub-stations.) (All Material provided by contractor for above work) |
50 | WORK OF MAKING 10 NOS. NEW PLINTHS DISTRIBUTION T/F IN PLACE OF FULLY DAMAGE PLINTH / CAHAIR AT VARIOUS PLACE AS PER FOLLOWING :- |
51 | Unmounting of T/F from plinth disconnecting all connection work including loading, carriage & unloading from work site. |
52 | Construction of new distribution T/F Plinth. The size of plinth shall be 2 Mtrs. long, 2 Mtrs. wide and height 1.5 Mtrs. from ground level with 15 CM thick top CC slab and MS channel 125x65mm. The above work includes Excavation of earth, laying of bring ballast pad for foundation brick work, CC and plastering and proper curing complete with all respects as per RESPO schedule. (All Material provided by contractor for above work.) |
53 | Mounting of T/F on plinth making all connection work including loading, carriage & unloading from work site. |
54 | PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR ABOVE NEW L.T. FEEDER PILLAR, ACB AND DTs(WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING (The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM.) :- |
55 | Providing of earth elctrode for chemical earthing Pipe in pipe typeproper hot deep galvanization dia 50 mm length 3 mtr- 32mm x 6mmterminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for above new L.T. Feeder Pillar, ACB & DTs. |
56 | Providing and fixing of GI strip of size 50 mm x 6 mm suitable for above new L.T. Feeder Pillar, ACB & DTs. |
57 | Providing and fixing of PVC Pit covers for above earthing electrode terminals. |
58 | Dismantling of ST Pole off size (Old & used) on work site. |
59 | Carriage of above dismantled pole from works site to JE store / central store & proper stacking with loading & unloading. |
60 | Dismantling of 11 KV Pin Insulator with pin (Old & used) on work site. |
61 | Carriage of above dismantled insulator from works site to JE store / central store & proper stacking with loading & unloading. |
62 | Dismantling of LT ACB damaged (Iron Scrap) on work site. |
63 | Carriage of above dismantled ACB from works site to JE store / central store & proper stacking with loading & unloading. |