Tender For Providing Maintenance For Various Type Airconditioning Split Or Ductable Or Cassette Type Units And Exhaust Fans In Telephone Exchanges Admin Bldg Bts Sites In Ernakulam, Thrissur, Palakkad, Calicut Bas Under Kerala Circle For A Period Of, ernakulam-Kerala

Bharat Sanchar Nigam Limited-BSNL has published Tender For Providing Maintenance For Various Type Airconditioning Split Or Ductable Or Cassette Type Units And Exhaust Fans In Telephone Exchanges Admin Bldg Bts Sites In Ernakulam, Thrissur, Palakkad, Calicut Bas Under Kerala Circle For A Period Of. Submission Date for this Tender is 09-05-2024. Air Conditioner Tenders in ernakulam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

43256839
Tender For Providing Maintenance For Various Type Airconditioning Split Or Ductable Or Cassette Type Units And Exhaust Fans In Telephone Exchanges Admin Bldg Bts Sites In Ernakulam, Thrissur, Palakkad, Calicut Bas Under Kerala Circle For A Period Of
Open Tender
Indian
Kerala
ernakulam
09-05-2024

Tender Details

Providing Maintenance For Various Type Airconditioning Split Or Ductable Or Cassette Type Units And Exhaust Fans In Telephone Exchanges Admin Bldg Bts Sites In Ernakulam, Thrissur, Palakkad, Calicut Bas Under Kerala Circle For A Period Of 2 Years

Key Value

Document Fees
Refer document
EMD
INR 481806.0 /-
Tender Value
INR 2.40 Crore /-

BOQ Items

Name of Work: Providing maintenance for various type Airconditioning units(Split/Ductable/Cassette type ) and exhaust fansin Telephone Exchanges / Admin Bldg /BTS sites in Ernakulam, Thrissur, Palakkad, Calicut BAs under Kerala Circle for a period of 2 years
Sl. No. Item Description
1Package 1 (Ernakulam, Aluva and Muvattupuzha (Zone-1))
2Part A: Servicing and Repairing of AC units
3Providing maintenance and servicing of 1.5/2 TR Split/ductable/ casette AC unit (cleaning of indoor unit filters and outdoor coil fins) of inverter/ordinary split AC units on call basis as per BSNL standard and specification by deploying the required specialised and skilled man power including Sundays and all other holidays by arranging and replacingthe minor spare parts such as indoor blower capacitor,blower bush, connectors, fuses, wires, termination etc checking of all components and accessories, checking and correcting discrepancies inelectrical/ refrigerant/ drainage circuits, tightening of all electrical connections, arresting drainage leakage, checking allfunctional parameters for upkeeping the AC units in operation at various TEs/BTS in the BA etc as required. The work shall be carried outon call basis & site requirement basis andduration between twosuccessive servicing of any unit shall be not less than three months
4Carrying out water servicing of inverter/ordinary1.5/2 TR Split/ductable/casette AC unit of all types, both indoor and outdoor unit etc as required. The work shall be carried out on call basis, once in a yearand preferablyduring february/March.
5NOTE: Supply and replacing of following spares on call basis (Minimum warranty ofone year shall be extended for replaced partsincludinggas charging from the dateof gas charging.)
6Supply and Replacement of the following items which is suitable for 1.5 TRinverter typesplit AC units, after removing the damageditems, including making all electrical and mechanical connections, testing etc. as required
7Indoor swing motor
8Indoor blower wheel
9Indoor blower fanmotor for1.5 TRinverter type ST AC units
10Outdoor fan motor for1.5 TRinverter type ST AC units
11PCB Control cardof 1.5 TR inverter type S/T AC units-indoor
12PCB Control cardof 1.5 TR inverter type S/T AC units-out door
13Cooling/thermostatsensor suitable for 1.5 TR S/T A/C Units
14Condenser fan blade
15Topping up of refrigerant gas R-22/R410/R32/R290for 1.5/2.0TR Split AC unit (inveter /non inverter type)
16Complete refillingof refrigerant gas recommended by the OEMin 1.5 TR/2 TRinverter type /non Inverter typeS/T AC units includingflushing out the existing refrigerant gas, leak arresting, pressure testing, charging the refrigerantetc as required. This work shall be guaranteed for one yearfrom the date of charging of refrigerant. Any shortage in refrigerant shall be topped up free of cost. Refrigerant reccomended by the OEM of AC unit shall only be charged.
17R-22 refrigerant
18R-410 refrigerant
19R-290 refrigerant
20R-32 refrigerant
21Supply and Replacement of the following items which is suitable for 1.5 TR star rated /ordinary split type AC (non inverter type) units, after removing the damageditems, including making all electrical and mechanical connections, testing etc. as required
22Indoor swing motor
23Indoor blower wheel
24Indoor blower fanmotor for1.5 TRST AC units
25Starting /Running capacitorsuitable for Compressor
26Outdoor fan motor for1.5 TRST AC units
27PCB control card suitable for 1.5 TR S/T A/C Units
28Cooling/thermostatsensor suitable for 1.5 TR S/T A/C Units
29Condenser fan blade
30Supply of Rotary Compressor suitable for 1.5 TR S/T A/Csuitable for non inverter type ACunit, fixing the same in unit, giving electrical and mechanical connections,leak testing, purging, gas charging with refrigerant gas, testingetc as required.The item shall be executed for compressors not under manufacturer warranty on buy back basis and the rate for the new compressor shall be quoted considering the scrap value of the old compressor .
31Supply of Rotary Compressor suitable for 1.5 TR S/T A/Csuitable for inverter type ACunit(variable speed type), fixing the same in unit, giving electrical and mechanical connections,leak testing, purging, gas charging with refrigerant gas, testingetc as required.The item shall be executed for compressors not under manufacturer warranty on buy back basis and the rate for the new compressor shall be quoted considering the scrap value of the old compressor .
32Dismantling of faulty compressor which is under warranty period after necessary pumping down and transporting it to the dealer for replacement and fixing the new compressor given by the OEM in the same unit, testing, commissioning etc as required. The cost of compressor will be borne by the OEM/OEM authorised dealer.The vendor has to take up the work with the supplier/OEM/authorised service dealer /distributoras per the direction of Enginer in charge .
33Providing maintenance and servicing of 3.0 TR ductable/casette AC unit(cleaning of indoor unit filters and outdoor coil fins ) of inverter/ordinary split AC units on call basis as per BSNL standard and specification by deploying the required specialised and skilled man power including sundays and all other holidays by arranging the minor spare parts such as indoor blower capacitor, connectors,fuses, wires,termination, etc checking of all components and accessories, checking and correcting discrepancies inelectrical/ refrigerant/ drainage circuits, tightening of all electrical connections, arresting drainage leakage, .checking allfunctional parameters for upkeeping the AC units in operation at various TEs in the BA etc as required .The work shall be carried outon call basis & site requirement basis andduration between twosuccessive servicing shall be not less than three months
34Carrying out water servicing of inverter/ordinary3.0 TR ductable/ casette AC unit of all types ,both indoor and out door unit etc as required
35Part B : Shifting and ITC of AC units
36Note:Shifting and ITC of AC units (Minimum warranty of 1 year shall be ensured for newly carried out work from the date of completion of work except the existing AC unit )
37Dismantling the existing 1.5 TR S/T AC Unit from the installed location in the GF/IF/2F/3F/4th floor along with the supports, refrigerant pipelines, protection pipes, electrical cables cables, drain pipes etc fixed on the external wall of the building without any damage including pumping down the refrigerant gas, making good the damages on the walletc as required. (Note : This item shall be executed for reinstalation works and not on the units proposed for scrapping.)
38Transportation of 1 No. 1.5 TR Split type ACunit (both condenser and evaporator units including all accessories) from one SDCA to another SDCAwithina BA (Business Area ) without any damage I/c loading, unloading etc. as required.
39Indoor unit only
40Out door unit only
41Both indoor and outdoor unit
42Transportation of 1 No. 1.5 TR Split type ACunit (both condenser and evaporator units including all accessories)within SDCA of a BAwithout any damage I/c loading, unloading etc. as required.
43Indoor unit only
44Out door unit only
45Both indoor and outdoor unit
46ITC ofexisting 1.5 TR S/T AC unit I/c outdoor on existing frame on any floor/terrace of the buildingand indoor unit on wallon the existing frame with nuts and bolts,giving electrical /refrigerant connections, testing and commissioning etc.(Cost of refrigerant and its charging is not included in this item)
47Replacing the faulty outdoor unit ofAC Unit by swapping with the outdoor unit of 1.5 TR Split Type AC unit available at BSNL building including giving all kind of mechanical and electrical connections, etc as required. Nothing extra shall be paid for shifting within the building or same compound.
48Replacing the faultyindoor unit ofAC Unit by swapping withindoorunit of 1.5 TR Split Type AC unit available at BSNL buildings. Including giving all kind of mechanical and electrical connections, etc as required. Nothing extra shall be paid for shifting within the building or same compound.
49Replacing the faulty compressor ofAC Unit by swapping the compressor of 1.5 TR Split Type AC unitof the switched off / scrapped unit available at BSNL buildings, including giving all kind of mechanical and electrical connections, etc as required .
50Supplying and fixing combined supply and return refrigerant copper piping suitable for the AC units available atsite, i/c supply and providing necessary thermal insulation, interconnection between indoor and out door unitetc. as reqd.
51Supply and drawing 3cx 2.5 sqmm pvc insulatedcopper conductor cable to extend AC supply between indoor and out door unit i/c giving connections tc as required
52Supplying and fixing of readymade powder coated heavy duty iron stand for mounting outdoor unit of the above AC including providing necessary hardware support etc complete as required.
53Supply and laying of 4cx1.5 sqmm copper cable or higher size as recommended by the OEM for inverter type AC unit interconnection between indoor and out doorunit etc as required (for additional length)
54S/F the following size good quality ISI mark PVC pipe,min 4kg/cm2of following size on the surface of wall/on the existing tray, with accessories for protection of Refrigerant lines / drain water connection etc. as required.
5563 mm dia
5640 mm dia
5720 mm dia
58Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
59Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( UPS DB)
60Single pole
61Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
622 X 4 sq. mm + 1 X 4 sq. mm earth wire
634X 4 sq. mm + 2 X 4 sq. mm earth wire
64Supply, fabrication and erection of MSstand suitable forfixing the outdoor unit of AC unitmade of MS angle Iron, MS Flats,etc includingapplying primer and two coats of enamel paint etc as required
65Part C: Maintenance of free cooling/exhaust fan system (Minimum warranty of 1 year shall be ensured for newly carried out work from the date of completion of work )
66Servicing and cleaning of fresh air filter made of nylon/similar material, cleaning of exhaust fans assembly, its louvers, checking electrical connections, checking and setting of timer circuit, if available at site etc as required. (The work shall be carried outon call basis & site requirement basis andduration between twosuccessive servicingshall generally be notless than three months. However, the Engineer in-Charge can carry out the work more number of times if the site demands more frequency for cleaning)
67SITC of Heavy duty exhaust fan of380 mm sweep,1400 RPM, 1910 CFM metal body and metal frame in the existing wall/prefab includingdismantling the faulty one, removing the debris, cleaning, making good the damages etc as reqd. (Make :- Almonard or Similar superior make).
68S/F450 mm x 450 mmsize suitable coarse filter made of nylon for collecting the dust in the intake air fitted on frame with removing facility etc as required
69S/F GI wire mesh at one end of size450 mm x 450 mmsize for replacing the faulty corroded wire mesh of size 1" x 1"atthe inletas required
70S/F Dial type 24 hourtimer suitable for 240 V, 50 HZ, AC supply, Base / DIN Mounting, with 16 A Contact Rating in resistive load with manual Over-Ride facility with enclosureincluding testing, commissioning, sign writing etc. as required.( Timer Make- L&T-FM1/QTor similar superior make)