Tender For Provision Of Servo Stabilizer For Certain Critical Equipment, Installation Of Oxygen Pipeline At New Smc Building, Provision Of Split Ac At Various Location And Provision Of Exhaust Fan At Dsc Mess At Afs Tezpur Under Ge (Af) Tezpur., tezpur-Assam

Military Engineer Services-MES has published Tender For Provision Of Servo Stabilizer For Certain Critical Equipment, Installation Of Oxygen Pipeline At New Smc Building, Provision Of Split Ac At Various Location And Provision Of Exhaust Fan At Dsc Mess At Afs Tezpur Under Ge (Af) Tezpur.. Submission Date for this Tender is 11-05-2024. Servo Stabilizer Tenders in tezpur Assam. Bidders can get complete Tender details and download the document.




Tender Notice

43254901
Tender For Provision Of Servo Stabilizer For Certain Critical Equipment, Installation Of Oxygen Pipeline At New Smc Building, Provision Of Split Ac At Various Location And Provision Of Exhaust Fan At Dsc Mess At Afs Tezpur Under Ge (Af) Tezpur.
Open Tender
Indian
Assam
tezpur
11-05-2024

Tender Details

Provision Of Servo Stabilizer For Certain Critical Equipment, Installation Of Oxygen Pipeline At New Smc Building, Provision Of Split Ac At Various Location And Provision Of Exhaust Fan At Dsc Mess At Afs Tezpur Under Ge (Af) Tezpur.

Key Value

Document Fees
INR 500 /-
EMD
INR 58980.0 /-
Tender Value
INR 29.49 Lakhs /-

BOQ Items

Name of Work:PROVISION OF SERVO STABILIZER FOR CERTAIN CRITICAL EQUIPMENT, INSTALLATION OF OXYGEN PIPELINE AT NEW SMC BUILDING,PROVISION OF SPLIT AC AT VARIOUS LOCATIONAND PROVISION OF EXHAUST FAN AT DSC MESS AT AFS TEZPUR UNDER GE (AF) TEZPUR.
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out, complete all as specified and directed.
2Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25 cm, watering and well ramming, removing surplus soil not exc.50m in soft/ loose soil, complete all as specified and directed.
3Material and labour for, broken stone or boulders hardcore of gauge not exc.63 mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
4Materials and labour for, plain cement concrete (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
5Material and labour for 100mm thick plain cement concrete (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in paving/ footpath, complete all as specified and directed.
6Supply and fix for, mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
7Material and labour for, pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed.
8Material and labour for point wiring with 1.50Sqmm (nominal area) FRLSH PVC insulated and unsheathed, multistranded copper conductor cable 1100 volts grade, single core, laid in and including not less than 20mm size PVC concealed conduit (medium grade) complete with all fittings and accessories suitable for one light/ fan point controlled by one switch including unsheathed single core stranded copper cable of size 1.50Sqmm as earth continuity conductor connected to common earth dollyto be terminated to sunken/ pressed steel flush box covered with outer/ inner plates etc. as per site requirement for mounting switches, socket, fan regulator etc. including testing on completion, complete all as specified and directed. (Notes: Metal flush box and cover plate shall be inclusive in the quoted rate)
9Supply and fix for, switch piano, flush type single pole, one way 5 Amp, complete all as specified and directed.
10Supply and fix for, ceiling rose, surface bakelite, 65mm x 50mm three terminals, complete all as specified and directed.
11Supply and fix for, exhaust fan, steel body AC single phase 230 volts of size 450mm sweep, heavy duty with blades and frame and louvers including cutting of walls for fixing of exhaust fan and make good disturbed surface all as per Cat No.CPTN-EXHD-450-4-1-NEO of make Crompton or equivalent model of make Bajaj/ Philips, complete all as specified and directed.
12Material and labour for, sub main/ circuit wiring with two single core FRLSH PVC insulated unsheathed cable 4.00 Sqmm (nominal area) with multistranded copper conductor cable, 1100 Volts grade, drawn through and including PVC casing and capping with accessories and earth continuity conductor of single core FRLSH PVC insulated, unsheathed multistranded copper cable 4.0 Sqmm (nominal area), 1100 volts grade and making disturbed surface, complete all as specified and directed. (Note: Two run of wiring cable, one run of earth wire and PVC casing & capping will be measured as one unit).
13Supply and fix for, MCB, SP, 240 volts, 10KA, "C" curve, 6 to 32 Amps, complete all as specified and directed.
14Supply and fix for, single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete including one double pole MCB 20 Amps capacity, complete all as specified and directed.
15Supply and install hi split units indoor/ outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2.0 TR, complete all as specified and directed.
16Supply and fix for, voltage stabilizer for automatic operation, single phase naturally air cooled designed for input variation between 130 volts to 250 volts with output voltage stabilized at 230 volt with accuracy ±2.5% of capacity 5 KVA, complete all as specified and directed.
17Supply and fix for, voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 volts to 480 volts with output voltage stabilized at 415 volt with accuracy ±2.5% and speed of correction 8 volts per second and of capacity 5 KVA, complete all as specified and directed.
18Supply and fix for, voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 volts to 480 volts with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 volts per second and of capacity 15 KVA, complete all as specified and directed.
19Supply and fix for, voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 volts to 480 volts with output voltage stabilized at 415 with accuracy ±2.5% and speed of correction 8 volts per second and of capacity 30 KVA, complete all as specified and directed.
20Material and labour for, earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.50 metre below normal ground level connected to galvanised steel earth lead strip of size 32x6 mm4mm dia by means of bolts, nuts, check nuts and washers of galvanised steel and connected to main switch boardor main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54cm x 54cm x 5cm reinforced with 8mm dia. TMT bars @150mm centre to centre both ways, with one handle for lifting made out of 10mm dia MS round bar 30 cm long, bent to shape, provision of funnel, wire mesh, 20mm bore galvanised steel tubing (medium grade) for watering, charcoal or coke and salt in alternate layers, 15mm bore galvanised steel tubing light grade for protection of earth lead connection, necessar excavation and earth work in any type of soil complete all as specified and indicated on electrical plate No.3 of SSR Part-I (2009) including testing on completion. (Note: GI earth strip and protection pipe upto 7.5metres shall be deemed to be included in unit quoted rate).
21Supply and fix for, earth continuity conductor or main earthinglead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to pole or any other indicated situation for loop earthing etc. as required by using GI earth strip of size 32x6 mm,complete all as specified and directed.
22Supply, laying, jointing and testing of LT XLPE insulated, PVC sheathed , armoured (heavy duty)electric cables with aluminiumconductor for working voltage upto and including 1100 volts of cross sectional area 25 Sqmm, 4.0 core, complete all as specified and directed.
23Supply, laying, jointing and testing of LT XLPE insulated, PVC sheathed , armoured (heavy duty)electric cables with aluminiumconductor for working voltage upto and including 1100 volts of cross sectional area 35 Sqmm, 3.50 core, complete all as specified and directed.
24Supply, laying, jointing and testing of LT XLPE insulated, PVC sheathed , armoured (heavy duty)electric cables with aluminiumconductor for working voltage upto and including 1100 volts of cross sectional area 50 Sqmm, 3.50 core, complete all as specified and directed.
25Supply, laying, jointing and testing of LT XLPE insulated, PVC sheathed , armoured (heavy duty)electric cables with aluminiumconductor for working voltage upto and including 1100 volts of cross sectional area 70 Sqmm, 3.50 core, complete all as specified and directed.
26Supply and fix for, 12mm dia copper pipe, hand drawn, tempened, seamless, phosphorous deoxidized, non arsenic and degreased conforming to 13348 specification of IS/ISO 7396-1 (2007) medical gas pipeline system including painting with thickness 0.7mm, laid as per HTM-2022 of UG specification. The supply of pipes accompany with manufacturer"s test certificates for the physical properties of copper pipes and their chemical composition .The supply of pipe line be further substantiated with inspection certificates from manufacturer"s maxflow.Copper pipe (imported) shall be made of copper and suitable for a team of working pressure of 17 bar and especially made for brazed socketed type connection. Copper fitting shall be made of copper and suitable for a steam of working pressure of 17 bar and especially made for brazed socketed type connection as per BS-857.Brazing for copper in brass, joints with copper silver as per BS 857.Brazing for corner in brass, joints with copper silver as per BS -1845-1966 with use of flux.Supports shall be provided to ensure that the pipe do not sag.The spacing of support shouldnotexceed 1.6 mm for any size of pipe.Suitable sleeves provided wherever pipes cross through wall/ slabs and all pipe clamps not reactive to copper complete all as specified and directed.
27All as per serial item No.26 here-in-before but dia of pipe15mm with thickness 0.9mm.
28Supply and fix for, surface mounted imported oxygen gas outlet point conforming to NFPA 99 specifications for gas outlet complete all as specified and indicated below :- (a) Theoutlets shall be UL listed, CSA certified fully compliance with latest edition of NFPA-99.(b) Consisting of a gas specific rough in assemblylatch valve assembly and cover plate.(c) Rough in assembly of modular design, a brass outlet block shall be attached to the mounting bracket to permit 1/2" OD type-K copper inlet tube to swivel 360 degrees forattachment to the piping system.(d) The outlet equipped with a primary and secondary check valve. (e) Latch valve assembly shall include a single compression seal primary valve.It shall be indexed to the corresponding rough in assembly toavoid accidental cross connection. (f) Single piece chromed fascia plate shall frame the outlet with the back rough-in-mounted.The outlet shall adjust from 3/8" (10mm) to 11" (25 mm) variation in wall thickness.(g) A large full colour coded front plate for ease of gas identification.(h) There shall be a push button release mechanism for disconnecting apparatus and shall be accessible from top bottom and side of the outlet.
29Supply, install, testing and commissioning of oxygen flow meter with humidifier bottle (indegenous). The back pressure compensated flow meter shall be accurate gas flow measurement and control within a range of 0-15 LPM for use in a variety of respiratory therapy gas delivery system. The flow tube and shroud component shall be made of brass duly nickel chrome plated. Flow meter shall be supplied with bubble type humidifier bottle. The humidifier bottle shall be of unbreakable materials, complete all as specified and directed. (Make : KINGCO/PES/MPS)
30Supply, installation, testing and commissioning of isolation valves for 15 mm copper pipe valves used will be of quarter tum action type for opening and closing the gas supply,valves shall beof non ferrous materials and havingfull bore and capableto with stand working pressure of 300 psi/27 Hg vacuum and shallhave the following specifications and directed:- (i) Body material-brass alloy.(ii)Ball- brass alloy hard chrome plated, pressure 20 bar size 15 NK 54 NK.(iii) Seal - PTFE. (iv) Handle-rugged steel with PVC grip. (v) Maximum working pressure-20 bar.(vi)Size-15 NB to 54 NB.
31Supply and fix for, distace alarm system for oxygen gas monitoring installed near outlet points with audio visual alarm showing working bank quantity in each banks, low pressure indicators etc. and all necessary indicators to monitor status of oxygen in each bank for ease of surgeon complete all as specified and directed.
32Supply, installation, testing and commissioning of 3 cylinder Oxygen manifolad, complete all as specified and directed
33Supply, installation, testing and commissioning of semi automation oxygen delivery control panel, complete all as specified and directed
34Material and labour for, brass NRV for gas pipe line of dia 15mm, complete all as specified and directed.
35Supply and fix for non return valve for connection of oxygen gas cylinder as approved suitable for oxygen copper pipe line complete all as specified and as directed.
36Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)