Irrigation And Flood Control Department-IFCD has published Tender For Annual Electrical Framework Contract Of Irrigation/ Dewatering Schemes Of Mechanical Irrigation Division Shadipora. Submission Date for this Tender is 16-05-2024. Desilting Tenders in Shadi pora Jammu And Kashmir. Bidders can get complete Tender details and download the document.
FileName | File Description | File Size |
9b51cc83-1f55-4d71-b40e-7c366acb9f8b.html | Tender Notice | 0 KB |
BOQ_723909.xls | Tender Document | 0 KB |
Tendernotice_1.pdf | Tender Document | 0 KB |
Sl. No. | Item Description |
1 | 1. CARRIAGE Mechanical transportation, loading, unloading and handling of various items suchaspumpparts,motors,starters,voltagestabilizers,coilassemblies, welding tools & plant, etc. using appropriate means of transport as under: Private car, auto-rickshaw or similar with 1.0 km lead |
2 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
3 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
4 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
5 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
6 | Load carrier auto, mini van or similar with 1.0 km lead |
7 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
8 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
9 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
10 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
11 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
12 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
13 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
14 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
15 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
16 | Truck, tipper or similar with 1.0 km lead |
17 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
18 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
19 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
20 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
21 | Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrain Upto 50 kgs load |
22 | Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) |
23 | Extra for uphill terrain (Ground Slope >= 07 deg) |
24 | VOLTAGE STABILIZERS Dismantlingof415V3-phVoltageStabilizerbywayofopeningoftoplid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. upto 50 kVA |
25 | >50 upto 100kVA |
26 | >100kVA upto 250 kVA |
27 | greater than 250 kVA |
28 | Assemblingofallpartsof3-phVoltageStabilizer,connectingofleadsofall incoming and outgoing connections and refilling of old drained out of T. Oil upto 50 kVA |
29 | >50 upto 100kVA |
30 | >100kVA upto 250 kVA |
31 | greater than 250 kVA |
32 | TRANSFORMER Dismantling of 33/0.4 kv or 11/0.4kV transformer by way of disconnecting of all HTandLTconnections,openingoftoplid,drainingoutofT.Oilanditssafe placement for further refilling, taking out of coils after removal of core assembly, etc. Job also includes detaching of core HV/LV coils. upto 50 kVA |
33 | >50 upto 100kVA |
34 | >100kVA upto 250 kVA |
35 | greater than 250 kVA upto 630kVA |
36 | Complete assembling of 33/0.4 kv or 11/0.4kV transformer after cleaning of tank, fitting of coil assembly in the tank. Job further includes closing of the transformer lid by way of fitting of existing nuts/bolts and gaskets, insulators, etc. Refilling of t.oil upto required level in tank. Reconnecting of HT/ LT connections and testing. upto 50 kVA |
37 | >50 upto 100kVA |
38 | >100kVA upto 250 kVA |
39 | greater than 250 kVA upto 630kVA |
40 | STARTER Isolatinganddisconnectingofallincomingandoutgoingleadsfrom autotransformer starter. Draining out transformer oil from the oil tank and collectinginasuitablevessel.Takingoutthedamagedautotransformercoil assembly from oil tank. upto 60 HP rating |
41 | >60 upto 200 HP |
42 | >200 HP upto 350 HP |
43 | greater than 350 HP |
44 | Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter. upto 60 HP rating |
45 | >60 upto 200 HP |
46 | >200 HP upto 350 HP |
47 | greater than 350 HP |
48 | WINDING WORKS Complete winding of stator coils of 3-phase LV horizontal/ vertical induction motor/ submersible motor/ autotransformer/ voltage stabilizer/ etc. and the like with suitable copper wire (excluding carriage and dismantling/ reassembling charges). (Note: The unserviceable scrap copper generated is not taken into account for estimation of rates and shall be accounted separately). Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., (Both HV & LV) - per kg of winding. |
49 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., (Both HV & LV) - per kg of winding. |
50 | Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. (excluding dismantling/ refitting charges) of motors upto 5HP |
51 | > 5 HP upto 20 HP |
52 | > 20 HP upto 50 HP |
53 | > 50 HP upto 100 HP |
54 | > 100 HP upto 200 HP |
55 | > 200 HP upto 350 HP |
56 | > 350 HP |
57 | VOLTAGE STABILIZERS Providing and replacement of copper contact points on regulator plate |
58 | ProvidingandFittingofLVcopperterminalconnectorswithalliedinsulation_(for finished weight of the connector) |
59 | ELECTROMAGNETIC BRAKES Providing and fitting of AC solenoid for electromagnetic brake of stroke length as under: (Preferred make: BCH or equivalent) 25mm |
60 | 30mm or above |
61 | Providing and fitting of AC solenoid brake having wheel diameter as under: 4 inch |
62 | 5.5 inch |
63 | 7 inch |
64 | 10 inch |
65 | Providing and fitting of drum for AC solenoid brake having wheel diameter as under: 4 inch |
66 | 5.5 inch |
67 | 7 inch |
68 | 10 inch |
69 | Providing and fitting of brake lining for AC solenoid brake having nominal wheel diameter as under: 4 inch |
70 | 5.5 inch |
71 | 7 inch |
72 | 10 inch |
73 | Providing and fitting of brake shoe assembly for AC solenoid brake having nominal wheel diameter as under: 4 inch |
74 | 5.5 inch |
75 | 7 inch |
76 | 10 inch |
77 | Providing and fitting of brake coil for AC solenoid brake having nominal wheel diameter as under: 4 inch |
78 | 5.5 inch |
79 | 7 inch |
80 | 10 inch |
81 | SLIP RING MOTORS Providing and replacement of carbon brush to 11kV slip ring motors as under 65mm x 50mm x 25mm (Grade: M16E) |
82 | Providing and replacement of brass brush holder of HV slip ring motor with pocket sizes as under: 38 x 32 mm |
83 | CONTACTORS Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage: L&T ML 1.5 |
84 | L&T ML 2 |
85 | L&T ML 3 |
86 | L&T ML 4 |
87 | L&T ML 6 |
88 | L&T ML 12 |
89 | L&T MNX 50 |
90 | L&T MNX 70 |
91 | L&T MNX 80 |
92 | L&T MNX 95 |
93 | L&T MNX 110 |
94 | L&T MNX 140 |
95 | L&T MNX 185 |
96 | L&T MNX 225 |
97 | L&T MNX 250 |
98 | MK1 |
99 | MK2 |
100 | MU1 |
101 | MU1H |
102 | MU2 |
103 | MU3 |
104 | ML2W |
105 | ML3W |
106 | ML4W |
107 | ML6W |
108 | Schneider Electric LC1F265 (without coil) |
109 | Schneider Electric LC1F330 (without coil) |
110 | Schneider Electric LC1F400 (without coil) |
111 | Schneider Electric LC1F630 (without coil) |
112 | 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) |
113 | 45AAC-3ratingwith2NO+2NCauxillarycontacts(Siemens3TF/L&TTypeMO/ Schneider) Providing and fitting of new AC coil with specified coil voltage for contactors: |
114 | 9A to 45A AC-3 rating (Siemens 3TF/ equivalent) |
115 | L&T ML 2/ 3 |
116 | L&T ML 4/ 6 |
117 | L&T ML 10/ 12 |
118 | L&T MNX 50/ 70/ 80 |
119 | L&T MNX 95/ 110/ 140 |
120 | L&T MNX 185/ 225/ 250 |
121 | L&T MNX 300/ 400 |
122 | L&T MNX 550/ 650 |
123 | Schneider Electric LC1F185/ LC1F225 |
124 | Schneider Electric LC1F265/ LC1F330 |
125 | Schneider Electric LC1F400 |
126 | Schneider Electric LC1F630 |
127 | Providing and fitting of new Contact kit set for contactors 32A AC-3 rating (Siemens 3TF/equivalent) |
128 | L&T ML 2 |
129 | L&T ML 3 |
130 | L&T ML 4 |
131 | L&T ML 6 |
132 | L&T ML 10 |
133 | L&T ML 12 |
134 | Providing and fitting of auxillary contactors/ control relay L&T MX0 having 04 contacts (all combinations) for AC control |
135 | L&T MX0 having 04 contacts (all combinations) for DC control |
136 | L&T ML (1NO+1NC) side mounting auxillary contact block |
137 | TIMING RELAYS Providing,fittingandsettingupofsinglerangeautoresetsynchronousONdelaytimer (L&T or equivalent make) |
138 | Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) (2NO + 2NC) double block; ON delay |
139 | (2NO + 2NC) double block; ON & OFF delay |
140 | Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) (2NO + 2NC) contact block |
141 | Magnetic coil 415V AC |
142 | Magnet frame assembly without coil |
143 | Providing,fittingandsettingofDINmountedelectronicTimer(L&TGICorequivalent make) Star Delta (range from 3s - 120s)240V AC |
144 | Star Delta (range from 3s - 30s)240 - 415V AC |
145 | ON delay (0.3s - 30hrs) 240V AC |
146 | THERMAL OVERLOAD RELAY Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) Relay range in between 0.2A to 15A |
147 | 14-23A |
148 | 20-33A |
149 | 24-40A |
150 | Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) 20-33A |
151 | 30-50A |
152 | 36-60A |
153 | 45-75A |
154 | 66-110A |
155 | Providing, fitting and setting of thermal overload relay of specified relay range L&T ML1 (Relay range in between 0.15A to 16A) |
156 | L&T ML2/3 (Relay ranges in between 9A to 42A) |
157 | MISCELLANEOUS Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots |
158 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. |
159 | CompletereplacementofsuitablecoppercontrolwiringofATSincludingcableties, connections, tapping and insulation as per requirement. |
160 | OIL IMMERSED STARTER SPARES Providing and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP |
161 | Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts) Upto 40 HP |
162 | Spares for oil immersed manual starters Fixed finger contact |
163 | Moving tip contact |
164 | No volt coil |
165 | Moving drum contact (starters upto 40HP) |
166 | Moving drum contact (starters > 40HP) |
167 | Base plate Bakelite/ DMC (starters upto 40HP) |
168 | Base plate Bakelite/ DMC (starters > 40HP) |
169 | Steam carrier assembly (starters upto 40HP) |
170 | Steam carrier assembly (starters > 40HP) |
171 | Sequence shaft (starters upto 40HP) |
172 | Sequence shaft (starters > 40HP) |
173 | Bakelite tube for Sequence shaft (starters upto 40HP) |
174 | Bakelite tube for Sequence shaft (starters > 40HP) |
175 | Trip rod assembly (starters upto 40HP) |
176 | Trip rod assembly (starters > 40HP) |
177 | Lock lever |
178 | Cam assembly |
179 | Oil dashpot assembly |
180 | Overload coil (set of 03 nos.) upto 20HP |
181 | Overload coil (set of 03 nos.) 30- 40HP |
182 | Overload coil (set of 03 nos.) 50- 60HP |
183 | Overload coil (set of 03 nos.) 70- 80HP |
184 | Overload coil (set of 03 nos.) 90- 100HP |
185 | L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARES Volt-Ammeter 500V, |
186 | Electronic Star-Delta Timer 3-30s |
187 | Providing and fitting of Terminal Block 60A - 3 way |
188 | 100A - 3 way |
189 | Single phase preventing relay Sz5 type |
190 | Single phase preventing relay SDz5 type |
191 | Providing,fittingandsettingofthermaloverloadrelayofspecifiedrelayrange (Make: L&T) MK1 (all ranges) |
192 | MU1 (all ranges) MU2 relays of following ranges |
193 | 9 - 14A |
194 | 13 - 21A |
195 | 15 - 25A |
196 | 20 - 32A |
197 | 24 - 38A |
198 | 28 - 42A |
199 | Providing and fitting of standard operating coil for following contactors MK1/ MK2 |
200 | MU1/ MU2/ MU3 |
201 | Providing and fitting of contact bridge without contact of following contactors MK1/ MK2 |
202 | MU1/ MU2/ MU3 |
203 | Providing and fitting of single moving contact of following contactors MK1 |
204 | MK2 |
205 | MU1 |
206 | MU2 |
207 | MU3 |
208 | SWITCHGEAR MCCB Providingandfittingof3-pole415VMCCBwiththermalmagneticrelease having36kAbreakingcapacity(Ics= 100% Icu) (Make: L&T d-sineor equivalent) having max. of thermal release range as under: upto and including 100A (Ics= 50% Icu) |
209 | 125A |
210 | 160A |
211 | 200A |
212 | 250A |
213 | 400A |
214 | Providingandfittingof3-pole415VMCCBwiththermalmagneticrelease having50kAbreakingcapacity Ics = 100% Icu (Make: L&T d-sineor equivalent) Having max. of thermal release range as under: 125A |
215 | 160A |
216 | 200A |
217 | 250A |
218 | 400A |
219 | 630A |
220 | Providing of set of spreader terminals for above 3-pole MCCBs 100A |
221 | 125A |
222 | 250A |
223 | 400A |
224 | 630A |
225 | Providingandfittingof4-pole415VMCCBwiththermalmagneticrelease having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: 125A |
226 | 160A |
227 | 200A |
228 | 250A |
229 | 400A |
230 | 630A |
231 | SPARES FOR ACB (L&T C-POWER) Providing and fitting of pole assembly for draw out type ACB (L&T C-power) upto 1250A |
232 | 2000A |
233 | Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) upto 1250A |
234 | 1600 - 2000A |
235 | Providing and fitting of Jaw contact for ACB (L&T C-power) 630-1000A |
236 | 1250A |
237 | 1600A/ 2000A |
238 | Providing and fitting of Fixed arcing contact for ACB (L&T C-power) 800- 1600A |
239 | 2000A |
240 | Providing and fitting of Moving arcing contact for ACB (L&T C-power) 800- 2000A |
241 | Providing and fitting of Shunt release for ACB (L&T C-power) |
242 | Providing and fitting of Under Voltage Release for ACB (L&T C-power) |
243 | Providing and fitting of Earth Fault Release for ACB (L&T C-power) |
244 | Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: upto 800 - 1250A |
245 | 1600 - 2000A |
246 | Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C- power ACB |
247 | Providing and fitting of CT for DN1 type L&T C-power ACB 800/ 1000A |
248 | 1250/ 1600A |
249 | 2000A |
250 | Providing and fitting of main spring for 3-pole ACB (L&T C-power) 800- 1600A |
251 | 2000A |
252 | Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A |
253 | Providing and replacement of spring charging motor (AC/ DC) |
254 | Providing and replacement of motor limit switch |
255 | SPARES FOR VCB Providing and replacement of Vacuum Interrupter Schneider VG-2 |
256 | Providing and replacement of following VCB parts (Schneider HVX 800A): Tripping Coil |
257 | Release/ Closing Coil |
258 | Spring charging Motor 110V DC/ 230V AC |
259 | Motor Cut-off Limit Switch |
260 | INSTRUMENTATION AND PANEL ACCESSORIES Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) Providing and fitting of flush type analog moving iron AC meter as under: (Make: Rishabh/ AE/ C&S/ BCH) |
261 | 48x48mm 500V voltmeter |
262 | 96x96mm 500V voltmeter |
263 | 144x144mm 500V voltmeter |
264 | 96x96mm ammeter (5A CT operated) |
265 | Providing and fitting of flush type frequency meter with range 45-55Hz: (Make: Rishabh/ AE/ L&T/ Schneider/ BCH) |
266 | Providingandfittingof10AlinecurrentammeterselectorswitchwithOFF (Make: L&T/Rishabh/ AE/ Teknic) |
267 | Providing and fitting of 10A voltmeter selector switch with OFF (Make: L&T/ Rishabh/ AE/ Teknic) |
268 | Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under: 100/5A or 150/5A - Class 1 - Burden 5VA |
269 | 200/5A - Class 1 - Burden 10VA |
270 | 400/5A - Class 1 - Burden 15VA |
271 | 600/5A - Class 1 - Burden 15VA |
272 | 800/5A - Class 1 - Burden 15VA |
273 | 1000/5A - Class 1 - Burden 15VA |
274 | 2000/5A - Class 1 - Burden 15VA |
275 | Extra for 1A secondary upto 600/1A over corresponding rate |
276 | Providing and fitting of analog VAC hour meter (Make: L&T or equivalent make) DIN mounting type |
277 | Flush mounting type |
278 | Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
279 | ProvidingandfittingofLEDphaseindicatorwithsurgeprotection(L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) |
280 | Providingandfitting3Phase,3/4WireadjustableUnder&OverVoltage monitoring relay (Minilec VCT D2 or equivalent) |
281 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) 50V or less unbalance & 1 C/ODIN mounted |
282 | 50V or less unbalance & 1 C/OPanel wall mounted |
283 | 70V or less unbalance & 2 C/ODIN mounted |
284 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) |
285 | Providing of HRC fuses (2A - 32A) ratings |
286 | Providing and fitting of Fuse holders for fuses upto 32A rating |
287 | Providing and fixing uPVC panel trunking with cover 15x15mm |
288 | 25x25mm |
289 | VCB PANEL ACCESSORIES Providingandfittingof96x96flushmounting3-phaseLEDMultifunctionMeterof Class 1 accuracy (Make: L&T/Schneider) |
290 | ProvidingandfittingofLEDEnergyMeterofClass1accuracywithRS485port facility (Make: Schneider EM1200) |
291 | Replacement of Trip Circuit Supervision Relay Alstom VAX31 ZGAT74BCH 110V DC |
292 | Replacement of Master Trip Relay Alstom VAJH13 YF0752 110V DC |
293 | Providing and replacement of 3-phase Over Current & Earth Fault Relay Make: L&T Model: MC31AnX |
294 | Make : L&T Model: MC61CnX (with high set and RS-485 port) |
295 | Schneider MiCOM P111 |
296 | Ashida ADR141A |
297 | Providing and replacement of motor protection relay Schneider Electric MiCOM P220 |
298 | Providing and replacement of static under and over voltage relay (C&S BU1-AC-UO) |
299 | Replacement of Alarm annunicator of below mentioned specifications 12-window (Proton Power Control/ equivalent) Op. Voltage : 110-125 V DC |
300 | Replacement of 4 inch nominal size electronic panel hooter (multivoltage). |
301 | Providing and replacement of multichannel temperature Scanner as under: 16-channel input & 8 channel relay output (Masibus 85xx+) |
302 | Providing and fitting of 25A standard mounting type Breaker Control Switch (TNC) with 01 Trip + 01 Close |
303 | 100W nominal output load Power Pack with Battery backup (ALAN India/ equivalent) |
304 | Providing and replacement of 1000uF 450VDC capacitor |
305 | Providing and replacement of anti pumping relay |
306 | CABLES AND TERMINATION TERMINALS/ LUGS Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: 16 sq. mm |
307 | 25 sq. mm |
308 | 35 sq. mm |
309 | 50 sq. mm |
310 | 70 sq. mm |
311 | 95 sq. mm |
312 | 120 sq. mm |
313 | 150 sq. mm |
314 | 185 sq. mm |
315 | 225 sq. mm |
316 | 240 sq. mm |
317 | 300 sq. mm |
318 | 400 sq. mm |
319 | 500 sq. mm |
320 | 630 sq. mm |
321 | Providingandcrimpingofvariouscoppertubelugs(Dowells/Action/oranyother reputed make) with tapping, insulation as under: 16 sq. mm |
322 | 25 sq. mm |
323 | 35 sq. mm |
324 | 50 sq. mm |
325 | 70 sq. mm |
326 | 95 sq. mm |
327 | 120 sq. mm |
328 | 150 sq. mm |
329 | 185 sq. mm |
330 | 225 sq. mm |
331 | 240 sq. mm |
332 | 300 sq. mm |
333 | 400 sq. mm |
334 | 500 sq. mm |
335 | 630 sq. mm |
336 | CABLES Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab) 1.5 sqmm |
337 | 2.5 sqmm |
338 | 4.0 sqmm |
339 | 6.0 sqmm |
340 | 10.0 sqmm |
341 | 16.0 sqmm |
342 | 25.0 sqmm |
343 | 35.0 sqmm |
344 | ProvidingandfittingofXLPEinsulated,1100Vsinglecorearmouredindustrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 16.0 sqmm |
345 | 25 sqmm |
346 | 35 sqmm |
347 | 50 sqmm |
348 | 70 sqmm |
349 | 95 sqmm |
350 | 120 sqmm |
351 | 150 sqmm |
352 | 185 sqmm |
353 | 240 sqmm |
354 | 300 sqmm |
355 | 400 sqmm |
356 | ProvidingandfittingofXLPEinsulated,1100Vsinglecoreindustrialarmoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 16 sqmm |
357 | 25 sqmm |
358 | 35 sqmm |
359 | 50 sqmm |
360 | 70 sqmm |
361 | 95 sqmm |
362 | 120 sqmm |
363 | 150 sqmm |
364 | 185 sqmm |
365 | 240 sqmm |
366 | 300 sqmm |
367 | 400 sqmm |
368 | 500 sqmm |
369 | 630 sqmm |
370 | Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminiumcableasperIS7098(Preferredmake:Finolex/Gloster/Havells/KEI/ Polycab) 25 sqmm |
371 | 35 sqmm |
372 | 50 sqmm |
373 | 70 sqmm |
374 | 95 sqmm |
375 | 120 sqmm |
376 | 150 sqmm |
377 | 185 sqmm |
378 | 240 sqmm |
379 | 300 sqmm |
380 | 400 sqmm |
381 | 500 sqmm |
382 | 630 sqmm |
383 | CONTROL CABLES ProvidingandfittingofXLPEinsulated,1100VgradeindustrialarmouredCopper control cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) 6C x 1.5 sq. mm |
384 | 8C x 1.5 sq. mm |
385 | 10C x 1.5 sq. mm |
386 | 12C x 1.5 sq. mm |
387 | 2C x 2.5 sq. mm |
388 | 4C x 2.5 sq. mm |
389 | 6C x 2.5 sq. mm |
390 | 8C x 2.5 sq. mm |
391 | 12C x 2.5 sq. mm |
392 | CABLE KITS Providing and fitting of Heat Shrinkable termination kit for 11 kV XLPE Cable (outdoor type) 3C x 50 sq.mm |
393 | 3C x 95 sq.mm |
394 | 3C x 120 sq.mm |
395 | 3C x 185 sq.mm |
396 | 3C x 300 sq.mm |
397 | 3C x 400 sq.mm |
398 | Heat Shrinkable termination kit for 11 kV XLPE Cable (Indoor type) 3C x 50 sq.mm |
399 | 3C x 95 sq.mm |
400 | 3C x 120 sq.mm |
401 | 3C x 185 sq.mm |
402 | 3C x 300 sq.mm |
403 | 3C x 400 sq.mm |
404 | Heat Shrinkable termination kit for 11 kV XLPE AB Cable (Outdoor type) Upto 150 sq.mm |
405 | 185 sq.mm to 300 sq. mm |
406 | Heat Shrinkable Straight Through Joint Kit for 11 kV HT AB Cable Upto 120 sq.mm |
407 | 150 sq.mm to 185 sq. mm |
408 | 240 sq. mm to 300 sq.mm |
409 | LIGHTING AND ILLUMINATION WIRING Providing and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) 1.0 sqmm |
410 | 1.5 sqmm |
411 | 2.5 sqmm |
412 | 4.0 sqmm |
413 | 6.0 sqmm |
414 | 10.0 sqmm |
415 | 16.0 sqmm |
416 | 2x1.5 sqmm |
417 | 2x2.5 sqmm |
418 | 2x6 sqmm (Aluminium unarmoured) |
419 | CONDUITS Providing and fixing 25mm PVC round conduit (medium) with allied PVC fittings |
420 | Providing and fixing uPVC trunking 25x16mm with allied fittings |
421 | Providing and fixing Polypropylene Corrugated flexible conduit 25mm |
422 | 32mm |
423 | Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. 100 x 50 x 1.6mm |
424 | 150 x 50 x 1.6mm |
425 | ELECTRICAL FITTINGS Providing and fitting of various electrical fittings as under (Preferred makes: Anchor/ SSK/ Havells) Switch-6A-SP-1way, 240V, 50 Hz, AC. |
426 | Switch-6A-SP-2way, 240V, 50 Hz, AC. |
427 | CordSwitches:-Providingandfittingofcordswitch-6A-SP-1way,240V,50Hz,AC/ hanging bell push. |
428 | Bell push 240V, 50 Hz, AC. |
429 | 6A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC. |
430 | Neon indicator |
431 | Mini telephone jack |
432 | Fan regulator (Mini) with rotary step |
433 | Fan regulator (Deluxe) with rotary step |
434 | Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC. |
435 | Plug Top 15/16A 3 Pin (ISI Marked) |
436 | 32A TP switch 415V with neon |
437 | 32A DP switch 240V with neon |
438 | Surface mounting box for switches as follows: 1 Gang box |
439 | 2 Gang box |
440 | 3 Gang box |
441 | 4 Gang box |
442 | 5 Gang box |
443 | 6 Gang box |
444 | 7 Gang box |
445 | 4 Gang box (double domestic) |
446 | Providing, Fixing, Testing of 6A ceiling rose |
447 | Providing and installation of Pendant/ angle/ batten holders 6A 240V |
448 | Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) 4 way |
449 | 8 way |
450 | 12 way |
451 | 16 way |
452 | Providing and installationof ‘B’SeriesMCB240V, 50Hz,10kA Suitableforlighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) 6-32A SP |
453 | 40A SP |
454 | 6-32A DP |
455 | 40A DP |
456 | 100A 4P isolator |
457 | ProvidingandinstallationofChangeoverswitchesofmetalenclosure240v50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) 2-pole 16A 415V |
458 | 2-pole 32A 415V |
459 | 4-pole 32A 415V |
460 | 4-pole 63A 415V |
461 | 4-pole 100A 415V |
462 | Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T) 63A 415V |
463 | 100A 415V |
464 | 200A 415V |
465 | Providing and installation of various type of fans as under: (Preferred makes: Havells/ Orient/ Crompton) Industrial exhaust fan 450mm metallic |
466 | Exhaust fan 250mm Plastic |
467 | Ceiling fan 1200mm sweep |
468 | Wall fan 300mm sweep |
469 | ILLUMINATION LED Bulbs withE27 or B22 base and illumination 3000K/ 5700K/ 6500K (Preferred makes: Havells/ Philips/ Osram/ Eveready/ Crompton/ Syska/ Bajaj/ Andslite) 0.5W |
470 | 5W |
471 | 9W |
472 | 15W |
473 | Providing, installation and testing of die-cast aluminium floodlight LED, colour temperature 5000 to 6500K, IP65 (Preferred makes: Havells/ Philips/ Osram Ledvance/ Crompton) 30W |
474 | 50W |
475 | Street-lighting:Outdoorpressuredie-castaluminiumIP66roadwayluminaire (streetlight) with high power LED as light source (Preferred makes: Havells/ Philips/ Osram Ledvance) 30W |
476 | 70W |
477 | 90W |
478 | Pressuredie-castaluminiumfloodlightluminaireforlineartungstenhalogenlamp (Havells/ Philips) 500w |
479 | 1000w |
480 | Pressure die-cast aluminium integral floodlight luminaire parts for Havells Jeta 6 Ballast |
481 | Housing |
482 | Providing and fitting of Open Construction (OC) Ballast for HID Lamps - 240V 50Hz 1x70W SON/MH |
483 | 1x150W SON/MH |
484 | 1x250W SON/MH |
485 | Providing and fitting of Ignitor for HID lamps 70 - 400W |
486 | Providing, fixing and testing of various types of lamps as under: (Preferred makes: Havells/ Philips/ Osram Ledvance/ Bajaj) Tungston linear halogen lamp 500W |
487 | 1000W |
488 | Metal Halide Lamp 70W/ 150W Single ended clear Tubular (MH SET) |
489 | 250W/ 400W Single ended clear Tubular(MH SET) |
490 | 70W/ 150W Double ended |
491 | High Pressure Sodium Vapour clear Tubular Lamp (SON-T) 70W |
492 | 150W |
493 | 250W |
494 | 400W |
495 | High Pressure Sodium Vapour Elliptical Coated Lamp (SON-E) 70W |
496 | PORTABLE LIGHTING 3 W Rechargeable LED torch (Preferred make: Havells/ Eveready/ Andslite/ Philips/ Syska) |
497 | LEDLanternwithTwinChargingmode– ChargingCable&SolarPanel(included) (Syska/ Havells/ Andslite/ Philips/ Bajaj) |
498 | MANPOWER HiringchargesofElectrician(fortroubleshooting/revampingofexistingelectrical fitting, etc. exclusive of specified works): |
499 | Hiring charges of Labourer for support of electrician |
500 | INSULATORS Supplyinganderectionofgalvanised‘D’ironclampscompletewithshackle insulator(75mmX90mm),G.Ibolts,nutsandwashers,coachscrewsetc.as required for LT lines. |
501 | Supplyinganderectionof100mmX80mmpininsulatorcompletewithG.I. Spindle and nuts etc. as required for LT lines. |
502 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
503 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. |
504 | Supplying and erection of11 KVdisc insulatorwith galvanisedinsulator fittings, ballandsockettypeandcompletewithgalvanisedstrainclamps,bolts,nuts, washers etc. as required. |
505 | Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lineswithgalvanisedinsulatorfittings,ballandsockettypeandcompletewith galvanised strain clamps, bolts, nuts, washers etc. as required. |
506 | LIGHTNING ARRESTOR Supplyinganderectionofthreepiecenonlinearresistortypelightningarrestor suitablefor3wire,11KVoverheadlineswithratedvoltage9KV(rms)witha nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
507 | Supplyinganderectionofsinglepiecenonlinearresistortypelightningarrestor suitablefor3 wire, 33 KVoverhead lineswith ratedvoltage 30 KV (rms)with a nominaldischargecurrentratingof10KA(stationclass)andcompletewith galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
508 | Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I.tube,havingsingleprongattop,with85mmdia6mmthickG.I.baseplate including holes etc.complete as required. |
509 | FUSES Supply and erection of 200A horn gap fuse setwith postinsulators suitablefor 3 wire, 11 KV overhead lines. |
510 | Supply and erection of horn gap fuse set with post insulators suitable for 3 wire, 33 KV overhead lines. |
511 | Supply and erection of drop out fuse set suitable for 3 wire, 11 KV overhead lines. |
512 | Supply and erection of drop out fuse set suitable for 3 wire, 33 KV overhead lines. |
513 | Providing of 11Kv DO Operating Rod (FRP) with min. 18 ft length |
514 | Providing of 33Kv DO Operating Rod (FRP) with min. 18 ft length |
515 | Providing and fitting of fuse element of required current rating for DO Fuse. |
516 | Providing of requisite tinned copper fuse wire |
517 | SWITCHES Providingandfittingof11KV200A3-phGangoperatedAirBreakSwitch complete with operating mechanism |
518 | Providing and fitting of 33 KV 400A 3-ph Gang operated Air Break Switch |
519 | Providing and fitting of following Air Break switch accessories Providing and fixing of Air Break Switch Handle |
520 | Providing and fixing of "DANGER" plate of standard size for 440V/ 11KV/ 33KV. |
521 | EARTHING EarthingwithG.I.earthplate600mmX600mmX6mmthickincluding accessories,andprovidingmasonryenclosurewithcoverplatehavinglocking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required. |
522 | Supplyingandlaying6SWGG.I.wireat0.50metrebelowgroundlevelfor conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
523 | Supplying and laying 25mm X 5mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. |
524 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
525 | Providingandfixing25mmX5mmG.IstriponsurfaceorinrecesswithGI saddles and allied fittings for connections etc. as required. |
526 | TRANSFORMER ProvidingnewCRGOlaminationtothecoreinplaceofdamagedcorewherever necessary including cost of materials and labour |
527 | Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied such as varnish and labour, drying, etc., (Both HV & LV) - per kg of winding. |
528 | Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such asvarnish and labour, drying, etc., (Both HV & LV) - per kg of winding. |
529 | Providing and fitting of finishednew aluminium wirewindings with insulation in placeofdamagedwindingsincludinglabourcosts,etc.,(HV/LV)-perkgof winding. |
530 | Providing and fitting of finished new aluminium stripwindings with insulation in placeofdamagedwindingsincludinglabourcosts,etc.,(HV/LV)-perkgof winding. |
531 | Rewindingwithre-insulationofexistingcopperconductors(HV)bywayof providing and replacement of inter-layer insulation - per kg of winding. |
532 | Rewinding with re-insulation, ducting of existing copper conductors (LV) by way of providing and replacement of inter-layer insulation - per kg of winding. |
533 | Rewindingwithre-insulationofexistingaluminiumconductors(HV)bywayof providing and replacement of inter-layer insulation - per kg of winding. |
534 | Rewindingwithre-insulationofexistingaluminiumconductors(LV)bywayof providing and replacement of inter-layer insulation - per kg of winding. |
535 | ProvidingandfittingofHotdippedgalvanisedMSnuts,boltsandwashersof assorted sizes |
536 | Supply of Neoprene Rubberized Gasket Sheet 3mm thick |
537 | 5mm thick |
538 | 6mm thick |
539 | Credit value for scrap copper |
540 | Credit value for scrap aluminium |
541 | Providing and fitting of LV (1.1 KV) porcelain bushings of rating: 250 A |
542 | 630 A |
543 | 1000 A |
544 | 2000 A |
545 | 3150 A |
546 | Providing and fitting of HV porcelain bushings of rating: 250 A, 17.5KV |
547 | 630 A, 17.5KV |
548 | 1000 A, 17.5KV |
549 | 2000 A, 17.5KV |
550 | 250 A, 36KV |
551 | 630 A, 36KV |
552 | 1000 A, 36KV |
553 | 3150 A, 36KV |
554 | Providing and fitting of metal part stem with allied fittings of transformer bushings (HV/ LV) as under: Brass |
555 | Aluminium |
556 | Copper |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy