Madhyanchal Vidut Vitran Nigam Limited has published Tender For New Connection / Line / Increasing Capacity & Its Associated Work Under Deposit Scheme In The Area Of Electricity Distribution Sub Division-2Nd Itauli & Sandi Road Grameen Under Jurisdictionof Electricity Distribution Division-Ii, Hardoi. Submission Date for this Tender is 03-05-2024. Electrification Work Tenders in hardoi Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Safe loading Carriage & unloading of following material from store centre to pit site/JE dump store. |
2 | PCC pole 8.5 mtr long. |
3 | ST pole 11 mtr. Long. |
4 | 11 KV XLPE cable of size 3x70 sq.mm. |
5 | 11 KV XLPE cable of size (3X120, 3x185, 3X300 sqmm) |
6 | LT XLPE Cable Aluminum 3.5×240mm2 |
7 | LT XLPE Cable Aluminum 3.5×400mm2 |
8 | LT XLPE Cable Aluminum 1×240mm2 |
9 | LT XLPE Cable Aluminum 1×400mm2 |
10 | G.I Wire |
11 | Stay Set Complete |
12 | 33, 11 KV Pin with Net |
13 | Disc insulator With fitting (B&S) 70KN |
14 | MS Earthing Rod(2540x20 mm) With Fitting |
15 | 11 KV Indoor Metering cubicle |
16 | 11/0.4 KV T/F 250/400/630 KVA |
17 | 11/0.4 KV T/F 100 KVA |
18 | 11/0.4 KV T/F 63 KVA |
19 | 11/0.4 KV T/F 25/16/10 KVA |
20 | 11 KV outdoor, pole mounted CT/PT. unit. |
21 | ACSR Weasel Conductor |
22 | Dog/Rabbit conductor |
23 | ABC (1X16+1X25)Sqmm |
24 | ABC (3X50+1X35+1X16)Sqmm |
25 | ABC (3X95+1X70+1X16 Sqmm) |
26 | ABC (3X120+1X95+1X16 Sqmm) |
27 | Line Meterial |
28 | Cable box (3X70/3X120/3X185/3X300) Indoor & Outdoor |
29 | Work |
30 | Erection of PCC 8.5 mtr long single pole with Grouting & with all accessories |
31 | Erection of PCC 8.5 mtr long double pole with Grouting & with all accessories |
32 | Erection of STP 11 mtr long single pole with Grouting & with all accessories |
33 | Erection of STP 11 mtr long double pole with Grouting & with all accessories |
34 | Fabrication & Erection of cable stand made of two nos MS Channel 100x50x3 mtr. Long jointed to each other by means of 5nos MS Strip 50x6mm of size 150mm long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamps also. all the materials i.e. clamps nut bolts will provide by contractor. |
35 | Grouting and Nozzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (sand, brick blast & cement). All material except stay wire shall be supplied by the contractor. |
36 | Ordinary earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule. All material except earthing rod shall be supplied by the contractor. |
37 | Complete jumpering with help of GI pipe as per RESPO norms GI pipe and other required material shall be supplied by contractor. |
38 | Laying of 11KV 3x70 sqmm single XLPE cable by digging of trench size 500 mm wide 900 mm after laying of brick, sand and stone slab. |
39 | Laying of 11KV (3X120, 3X185, 3X300 sqmm) single XLPE cable by digging of trench size 500 mm wide 900 mm after laying of brick, sand and stone slab. |
40 | Stringing & Sagging of LT XLPE Cable Aluminum 1×400mm2 |
41 | Stringing & Sagging of LT XLPE Cable Aluminum 3.5×400mm2 |
42 | Stringing & Sagging of LT XLPE cable (1×240)sq.mm. |
43 | Stringing & Sagging of LT XLPE cable (3.5×240)sq.mm. |
44 | Installation of 11 KV CT/PT double metering unit of constructed double pole structure as per RESPO norms. Only 11 KV CT/PT unit shall be supplied by department. |
45 | Fixing & commissioning of 11 KV pilfer Resistance meter (25/5Amp.) All material except pilfer Resistance metering cubical shall be supplied by the contractor. |
46 | Earthling by way of Boring and lowering the "B" class GI pipe (Gindal ) of 50mm dia from ground upto water level not less than 20mtr as per standard practice |
47 | Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. Brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level up to 15 centimetres below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimetre. Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand, cement and stone ballast in the ratio of 1:2:4.The T/Fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand.(All the material to be arranged by the contractor). |
48 | Placement of 11/0.4 KV T/Fs from dump place to newly constructed T/Fs plinth & installation, commissioning of 100/250/400/630 KVA T/Fs of T/FPlinth and including jumpering with the system ( Alltherequiredmartial for abovejob shall be provided by contractor except T/Fs) |
49 | Fabrication erection & commissioning of 100 KVA T/F on Double pole with all accessories. All material except 100 KVA T/F shall be supplied by the contractor. |
50 | Fabrication erection & commissioning of 63 KVA T/F on Double pole with all accessories. All material except 63 KVA T/F shall be supplied by the contractor. |
51 | Fabrication erection and commissioning of 25/16/10 KVA T/F on double/single pole with all accessories. All material except 25/16/10 KVA T/F shall be supplied by the contractor. |
52 | Stringing & Sagging of three phase 11 kv line |
53 | Stringing & Sagging of ACSR Dog/Rabbit Conductor 33 KVLine |
54 | Stringing & Sagging ABC (1X16+1X25)Sqmm |
55 | Stringing & Sagging ABC (3X50+1X35+1X16)Sqmm |
56 | Stringing & Sagging ABC (3X95+1X70+1X16 Sqmm) |
57 | Stringing & Sagging ABC (3X120+1X95+1X16 Sqmm) |
58 | Installation & commissioning of Distribution Box for ABC Bunch Conductor |
59 | Construction of toe wall around the 11/0.4 kv S/S, fuse unit size 0.75 Mt. At Base and 0.23 Mt. At top as per RESSPO Normsby lst class bricks in the ratio 1:6, Base concreting of the wall to be done in ratio 1:6:12 and plaster 12 mm thick in ratio 1:4.& fabrication of fencing with wire mesh 10SWG(37mmx50mm)(all material to bearranged by contractor). |
60 | Instalation of cable box 11 KV Indoor & Outdoor |
61 | Looping & chopping of tree branches for clearance of HT/LT line after clearance of line throughout pieces of tree branches of site (Approx 3 Km). |
62 | Dismantling of old & used (Existing) material and loading, Carriage & unloading from site to JE Dump store/store centre, Hardoi. |
63 | Dismentling of line (Scrap conductor) |
64 | PCC 8.5 mtr long single pole with all accessories |
65 | PCC8.5mtrlongdoublepolewith all accessories |
66 | STP 11 mtr long single pole with all accessories |
67 | STP 11 mtr long double polewith all accessories |
68 | TRANSFORMER 250/400/630, KVA |
69 | 100 KVA T/F on Double pole with all accessories. |
70 | 63/25 KVA T/F on Double pole with all accessories. |
71 | Carriage of material pit site to Hardoi store Je dump store/store center of Hardoi. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail