Tender For Repair/Maintenance Of Internal Wiring Distribution Board, Light Fittings And Allied Items In Domestic Area At Af Stn Ambala Under Ge (Af) Ambala, ambala-Haryana

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Internal Wiring Distribution Board, Light Fittings And Allied Items In Domestic Area At Af Stn Ambala Under Ge (Af) Ambala. Submission Date for this Tender is 18-05-2024. Electrification Work Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

43253000
Tender For Repair/Maintenance Of Internal Wiring Distribution Board, Light Fittings And Allied Items In Domestic Area At Af Stn Ambala Under Ge (Af) Ambala
Open Tender
Indian
Haryana
ambala
18-05-2024

Tender Documents

Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

Tender Details

Tender For Repair / Maintenance Of Internal Wiring Distribution Board, Light Fittings And Allied Items In Domestic Area At Af Stn Ambala Under Ge ( Af ) Ambala

Key Value

Document Fees
INR 500 /-
EMD
INR 97942.0 /-
Tender Value
INR 48.97 Lakhs /-

Attachment

FileName File Description File Size
a568aa00-8355-4684-adea-345b2da03fe2.html Tender Notice 0 KB
100TenderPages.pdf Tender Document 0 KB
BOQ_729167.xls Tender Document 0 KB
Tendernotice_1.pdf Tender Document 0 KB

BOQ Items

Name of Work: REPAIR/MAINT OF INTERNAL WIRING DISTRIBUTION BOARD, LIGHT FITTINGS AND ALLIED ITEMS IN DOMESTIC AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
Sl. No. Item Description
1Taking down carefully aluminum point wiring (light, fan, socket or power) complete fittings such as switches, ceiling roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, sketch fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. Making good to the disturbed surface by plastering and two coat of distamper matching with existing surface. complete all as specified and directed
2M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 19mm dia ISI marked and conduit accessories fixed concealed in wall with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
3One light/fan/ controlled by one switch 6 amp one way, complete all as specified and directed
4One 3 pinsocket outlet 6 amp on the independent board complete all as specified and directed
5One 3 pin socket outlet on same board with other switches complete all as specified and directed
6one bell point controlled by one bell push complete all as specified and directed
7one light point controlled by two way switch complete all as specified and directed
8All as per BOQ srl item No. 2.00 described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board complete all as specified and directed Note:For item 2 The rate of chase cutting and making good the surface will be deemed in the rates quoted by the contractor.
9M & L forpoint wiring in existing concealed conduit complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through existing conduit including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the followings
10One light/fan/ controlled by one switch 6 amp one way, complete all as specified and directed
11One 3 pin socket outlet 6 amp on the independent board, complete all as specified and directed
12One 3 pin socket outlet on same board with other switches, complete all as specified and directed
13One bell point controlled by one bell push complete all as specified and directed
14One light point controlled by two way switch complete all as specified and directed
15All as per BOQ srl Item No.4.00here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
16M & L forpoint wiring on wall/ surface in PVC conduit/ casing caping of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathedcable 1100 volts grade drawn through PVC conduit/casing caping including provisining of 1.5 sqmm FRLS PVC insulatedunsheathedcable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete for the following
17One light/fan/ controlled by one switch 6 amp one way,complete all as specified and directed
18One 3 pin socket outlet 6 amp on the independent board complete all as specified and directed
19One 3 pin socket outlet on same board with other switches complete all as specified and directed
20One bell point controlled by one bell push complete all as specified and directed
21All as per BOQ srl item No.6.00 here-in-above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathedcable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
22S&Fin replacement switchmodular type 5 amp single pole flush type one way of existing make complete all as specified and directed by EIC.
23S&F in replacementswitchmodular type 15 amp single pole flush type one way of existing make complete all as specified and directed by EIC.
24S&F in replacementmodular step type fan regulator electronic type 120 watt 1 module of existing make complete all as specified and directed
25M&Lin replacementsocket outlet modular type 5 pin 5 amp multi pin flush type of exising make complete all as specified and directed by EIC
26M&L in replacement socket outlet modular type 5 pin 15 amp multi pin flush type of exising makecomplete all as specified and directed by EIC
27S&F in replacementmodular cover plate with frame for 1 module of exising make complete all as specified and directed
28S&F in replacementmodular cover plate with frame for 3 module of exising makeall as specified and directed.
29S&F in replacementmodular cover plate with frame for 6 module of exising make complete all as specified and directed
30S&F in replacement modular cover plate with frame for 8 module of exising makecomplete all as specified and directed
31S&F in replacementmodular metal flush box 1 module of exising makecomplete all as specified and directed
32S&F in replacement modular metal flush box 3 module of existing make complete all as specified and directed
33S&F in replacement modular metal flush box 6 module of existing make complete all as specified and directed
34S&F in replacement modular metal flush box 8 module of existing make complete all as specified and directed
35M&L in replacementswitch piano flush type single pole, one way 6amp complete all as specified and directed
36M&L in replacement switch piano flush type single pole, two way 6amp complete all as specified and directed
37M&L in replacement switch piano flush type single pole, one way 15 amp complete all as specified and directed
38M&L in replacementsocket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed
39M&L in replacementsocket outlet 2 in 1 , 3 pin 5 A and 15 Aflush typecomplete all as specified and directed
40S/fix in replacement ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed
41S& F in replacementlamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting, complete all as specified and directed
42Supply and fixing in replacementbell push flush type 230 Volt complete all as specified and directed
43S&F in replacementcall bell ding dong 230 V single phase complete all as specified and directed
44S&F in replacementsocket type fan regulator electronic type complete all as specified and directed
45Taking down/out old unserviceable FTL fitting of any wattage and Supply and fixing Box type LED tube light fitting1x18 watt, 230 volts in commercial channel with powder coated CRCA sheet housing with incluiding LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser connecting with twin core twisted flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed Note :The LED fitting should Have input voltage 90-300V, luminaries efficacy > 100 lumen/watt
46Taking down/out old unserviceable FTL tube rod of any wattage and Supply and fixing LED tube rod1x18 watt, 230 volts complete with all accessories complete all as specified and directed Note :The LED rod should Have input voltage 90-300Vluminaries efficacy > 100 lumen/watt
47Taking down/out old unserviceable recessess/ surface mounting fitting of any wattage and Supply and fixing recess/Surface mounting LED flat panel 2"x2" with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed Note :The LED fitting should Have input voltage 90-300V . luminaries efficacy > 100 lumen/watt
48Taking down/out old unserviceable FTL fitting of any wattage and Supply and fixingLED batten with opal diffuser with inbuilt LED tube 10 watt 2 feet length and driver designed with high transmitting optics for even light distribution incl connecting with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed Note :The LED fitting should Have input voltage 90-300V, luminaries efficacy > 100 lumen/watt
49Taking down/out old unserviceable bulk head fitting of any wattage and Supply and fixing in replacement LED bulk head 10 watt with pressure die cast plasitc housing high efficient LEDs and enclosed with milky diffuserincl connecting with twin core twisted flexible copper conductor cable with suitable size complete with all accessories complete all as specified and directed Note :The LED fitting should Haveinput voltage 90-300V, luminaries efficiency> 100 lumen/watt
50Taking down/out old unserviceable building security light of any type / wattage and Supply and fixing LED light fittings 45 watts, input 120 volts to 280 volts volts, life > 25000 Hrs, operating temp -20 degree to 50 degree,color temperature 5700K, initial efiicacy>= 100 lm/watt ,IP 66 , high pressure Die cast aluminium housing with weather proof gasket for lamp . the driver must be constant current type having THD <10% and power factor >0.95 with short circuit protection , open circuit protection, reverse circuit protection, high voltage protection, protection against 5 KV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light controland comply to IEC60598/IS10322 necessary connection with multistranded copper conductor cable 3 core 1.0 sqmm from ceiling rose to fitting drawn throughGI bracket complete all as specified and directed .
51M&L for submain wiringin relacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall including conduit and conduit accessories and incl provn of PVC insulated 4.0 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earthing point of DB box all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper matching with existing surfaces complete all as specified and directed Note : Two runs of 4 sqmm cable alongwith one run of 4.0 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length.
52All as per BOQ srl item No 36above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit25 mm dia conduit medium grade complete all as specified and directed by Eng-in-Charge.
53S&F in replacementrecess mounting LED down light of 15 watt of existing make/model complete all as specified and directed.
54S&F in replacementrecess mounting low height backlit roundLED down light of 18 watt of existing make/model complete all as specified and directed.
55S&F in replacementrecess mounting low height backlit squareLED down light of 6 watt of existing make/model complete all as specified and directed.
56S&F in replacementrecess mounting low height backlit squareLED down light of 3 watt of existing make/model complete all as specified and directed.
57S&F in replacement LED post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection of 40 wattwith necessary connection of multistranded copper conductor complete all as specified and directed.
58Supply and fixincl taking down LED garden light fitting with LED bulb upto 9 watt with clear acrylic cover in top section with IP 43 protection including all electrical connection with gi pipe light grade upto 90 cm including foundation complete all as directed by Engr in Charge.
59S&Fincl taking down LED strip 1 watt flexible type warm white in colour10 mm width, complete all as specified and directed
60S&F incl taking down driver suitable for LED strip of 1 watt, complete all as specified and directed
61S&Fin replacement LED bush light 6 watt (warm white)and input voltage 230 VAC , 50 Hzwith cast aluminium housing with toughened glass IP-66 including fixing arrangementinto wall/ pillar with necessary connection of suitable size of copper conductor cablecomplete all as specified and directed by Engr-in- charge at site.
62S&F in replacement Aesthetically disignedLED post top lantern 15 Watt and input voltage 230 VAC , 50 Hz , withdie cast aluminium spigot & prismatic diffuser , IP-65/66 including fixing arrengment like clamp nut bolts and washers and necessaryconnection of suitable size of copper conductor cablecomplete all as specified and directed by Engr-in- charge at site.
63S&F in replacement Hylum Sheet of size 4X5, complete all as specified and directed
64S&F in replacement Hylum Sheet of size 8X5 complete all as specified and directed
65S&F in replacement Hylum Sheet of size 10X5, complete all as specified and directed
66S&F in replacement Hylum Sheet of size 8 x 10 , complete all as specified and directed
67S & F in replacement Hylum Sheet of size 10X12" complete all as specified and directed
68S & F ( in repacement) PVC round plate cover of size 4" to 6"complete all as specified and directed
69Taking out/dismantling of pressure pump of capacity 0.5 -1.0 HP atsite transport to reputed workshop for rewinding thepressure pump with the same gauge of copper winding wire as well as number of turns and reassembling the pump after replacing the unserviceable spares partlike bushes, shafts, fasteners, bearings, capacitors and copper wire for puttingpump in serviceable condition including refixing the sameafter carrying out necessary repairs to original place complete all as specified and directed by Engineer-in-Charge . Note :- Spare parts , rewinding work etc required for repairing the pump shall be deemed to be included in the quoted rate by contractor.
70Taking down old unserviceableAuto cutand supplying and fixing of newauto cut (pressure release valve ) suitable for pressure pump of capacity 0.5 -1.0HPcomplete all as directed by Engr -in- charge at site.
71S&F in replacement LED lamp 9 wattcomplete all as specified and directed
72S&F in replacement LED lamp 7 wattcomplete all as specified and directed
73S&Fin replacementof casing caping of size 20 mm with necessary fitting complete all as specifiedand directed by the EIC.
74S&F in replacement gang box 2 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
75S&F in replacement gang box 4 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
76S&F in replacement gang box 6 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
77S&F in replacement gang box 8 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
78S& F in replacement gang box 12 module suitable for mounting of 6 /16 switch and socket with necessary copper conductor cable complete all as specified and directed
79S&F in replacement sheet metal enclosures 4 way TPN Vertiacal type loadline distribution board of 4 wayincomer + 12 module outgoings ,double door IP 43 protection160 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces complete all as specified and directed .
80S&F in replacement sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus barincl making the surface good complete all as specified and directed.
81S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
82S&Fin replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
83S&Fin replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 12 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
84S&Fin replacement MCCB three pole415 Volts, 100 A, 16 KA complete all as specified and directed.
85S&Fin replacement MCB three pole and neutral 415 Volts, 63 A, 10 KA complete all as specified and directed.
86S&F in replacement MCBs 5 to 40 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB, complete all as specified and directed
87S&Fin replacement MCBs 5 to 32 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB, complete all as specified and directed
88Supply and fixing in replacement plug top of 15 Amp capacity 240V, single phase includingb connection complete all as specifeid and directed.
89M&L earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggalvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : (i) Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through DO. (ii) On testing, if the desired earth resistance is not obtained, enitre earthing shall be re-done by contractor till the desired earth resistance is obtained without accruing any extra cost to the government. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
90S&F, connecting & testing in replacementplug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified & directed by Engineer-in-Charge.
91S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core flat of size 6 sqmm sold aluminium conductor., complete all as specified & directed
92S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor derved with inner sheathing of PVC tape and overall PVC sheathed in service connectiontwin core flat of size 10 sqmm sold aluminium conductor, complete all as specified & directed
93S&F in replacementPVC insulated single core copper conductor of 1.5 sqmm, complete all as specified & directed
94S&F in replacementPVC insulated single core copper conductor of 2.5 sqmm, complete all as specified & directed
95S&F in replacementPVC insulated single core copper conductor of 6 sqmm, complete all as specified & directed
96S&F in replacementPVC insulated single core copper conductor of 4 sqmm, complete all as specified & directed
97S&F in replacement 2 core Flexible wire of 23/2, complete all as specified & directed
98Taking out/dismantling of oldunserviceable check valve of pressure pump of capacity (0.5 to 1 HP) and supply and fixing of newcheck valve made of brass size 15/25/32 mm dia complete all as specified & directed