|
| 1 | 24V DC 787A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD CR package of BRBCL/Nabinagar 4x250 MW as per technical specification |
| 2 | 24V DC 633A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD CR package of NPGCL/Nabinagar 3x660 MW as per technical specification |
| 3 | 24V DC 350A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD CR package of Sipat 2x500 MW as per technical specification |
| 4 | 24V DC 125A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for LHP MCC package of Sipat 2x500 MW as per technical specification |
| 5 | 24V DC 625A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD CR package of Barh stage-I 3x660 MW as per technical specification |
| 6 | 24V DC 200A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for LHP MCC package of Barh stage-I 3x660 MW as per technical specification |
| 7 | 24V DC 475A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD CR package of Barh stage-II 2x660 MW as per technical specification |
| 8 | 24V DC 185A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for LHP MCC package of Barh stage-II 2x660 MW as per technical specification |
| 9 | 24V DC 314A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD stage-I package of Kahalgaon project as per technical specification |
| 10 | 24V DC 433A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD stage-II package of Kahalgaon project as per technical specification |
| 11 | 24V DC 141A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for CR stage-I & II package of Kahalgaon project as per technical specification |
| 12 | 24V DC 40A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for DM CW package of Kahalgaon stage-I & II project as per technical specification |
| 13 | 24V DC 950A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for FGD CR package of Korba project as per technical specification |
| 14 | 24V DC 185A Intelligent Charger system with BHMS, serial link with MODBUS protocol,Inter-connection cables/lugs, battery isolation box, cable glands & lugs etc. for RIO package of Korba project as per technical specification |
| 15 | Training to end-user for 02 man-days at each project site |
| 16 | Mandatory Spares for BRBCL/Nabinagar 4x250 MW as per technical specification |
| 17 | Mandatory Spares for NPGCL/Nabinagar 3x660 MW as per technical specification |
| 18 | Mandatory Spares for Sipat 2x500 MW as per technical specification |
| 19 | Mandatory Spares for Barh stage-I 3x660 MW as per technical specification |
| 20 | Mandatory Spares for Barh stage-II 2x660 MW as per technical specification |
| 21 | Mandatory Spares for Kahalgaon stage-I & II as per technical specification |
| 22 | Mandatory Spares for Korba-FGD package as per technical specification |
| 23 | Freight charges for complete scope of supply for BRBCL/Nabinagar 4x250 MW (shall be paid on pro-rata basis proportionate to material cost) |
| 24 | Freight charges for complete scope of supply for NPGCL/Nabinagar 3x660 MW (shall be paid on pro-rata basis proportionate to material cost) |
| 25 | Freight charges for complete scope of supply for Sipat 2x500 MW(shall be paid on pro-rata basis proportionate to material cost) |
| 26 | Freight charges for complete scope of supply for Barh stage-I 3x660 MW (shall be paid on pro-rata basis proportionate to material cost) |
| 27 | Freight charges for complete scope of supply for Barh stage-II 2x660 MW (shall be paid on pro-rata basis proportionate to material cost) |
| 28 | Freight charges for complete scope of supply for Kahalgaon stage-I & II project (shall be paid on pro-rata basis proportionate to material cost) |
| 29 | Freight charges for complete scope of supply for Korba-FGD package (shall be paid on pro-rata basis proportionate to material cost) |
| 30 | Erection Supervision & Commissioning of charger system for BRBCL/Nabinagar 4x250 MW |
| 31 | Erection Supervision & Commissioning of charger system for NPGCL/Nabinagar 3x660 MW |
| 32 | Erection Supervision & Commissioning of charger system for Sipat 2x500 MW |
| 33 | Erection Supervision & Commissioning of charger system for Barh stage-I 3x660 MW |
| 34 | Erection Supervision & Commissioning of charger system for Barh stage-II 2x660 MW |
| 35 | Erection Supervision & Commissioning of charger system for Kahalgaon stage-I & II project |
| 36 | Erection Supervision & Commissioning of charger system for Korba-FGD package |
| 37 | Laptop (if applicable) for Main supply of each project, as per \"BoM for charger system\" under technical specification |