| 1 | Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) of size 2 core 10 sqmm to 3.5 core 50 sqmm complete all as directed. (Note :-Earth work to be measured and paid separately. |
| 2 | Supply, Laying and testingXLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testingcomplete of the following sizes and cross sectional area :- (Note :-Necessary earth work to be measured and paid separately. |
| 3 | 10 sqmm 2 core |
| 4 | 16 sq mm 2 core |
| 5 | 25 sq mm 4 core |
| 6 | 50 sq mm 3.5 core |
| 7 | Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed. |
| 8 | -ditto- but for depth beyond 1.50m & upto 3.0 m deep |
| 9 | Excavation of trench in road/hardstanding etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed. |
| 10 | Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed. |
| 11 | Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. |
| 12 | M&L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed.(Note: Punned thickness of sand shall be measured) |
| 13 | Supply & laying in Trenches, Sub-class ‘B’ Bricks, kiln burnt, laid perpendicular to the axis of cable for Cable Protection, complete all as specified and as directed. |
| 14 | Relaying of serviceable bricks for protection of LT UG cables, laid perpendicular to the axis of cable complete all as specified and directed. |
| 15 | S&F in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core, 1.50 sqmm, 1100 Volt, conforming to IS 694all as specified and directed |
| 16 | S&F in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core, 2.50 sqmm, 1100 Volt, conforming to IS 694all as specified and directed |
| 17 | Taking out existing unserviceable/ defective light fitting / high bay light fittingof any wattage from poles /walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of checking out the defects, trace out defects/ unserviceable parts like driver, wire,led lamp etc and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing complete all as specified and as directed by Engr-in-Charge.Note :- (1)Any minor item like nuts, bolts, clamps, washers and wires for connection is required to make the fitting serviceable are deemed to be included in the quoted rate. (2)Defective parts replaced against relevant items shall be paid under supply only item.(3) All UNSV light fitting shall be inspected & tested in presence of concerned JE/Engr-in-charge before and after repair. |
| 18 | Supply only electronic driver with input voltage 220 to 240 volts and output voltage suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-.(NOTE: Make of driver shall be as OEM or any other make as specifically approved by GE) |
| 19 | 30 watt luminaire |
| 20 | 45 watt luminaire |
| 21 | 50 - 60 watt luminaire |
| 22 | 70 - 80 watt luminaire |
| 23 | 90 - 100 watt luminaire |
| 24 | 120 watt luminaire |
| 25 | 150 watt luminaire |
| 26 | 180 watt luminaire |
| 27 | 200 watt luminaire |
| 28 | Supply only PCB card suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. |
| 29 | 30 watt luminaire |
| 30 | 45 watt luminaire |
| 31 | 50-60 watt luminaire |
| 32 | 70 - 80 watt luminaire |
| 33 | 90 - 100 watt luminaire |
| 34 | 120 watt luminaire |
| 35 | 150 watt luminaire |
| 36 | 180 watt luminaire |
| 37 | 200 watt luminaire |
| 38 | Supply only Surge Protection Device of capacity 10 KV Single Phase 50 Hz complete all as specified and as directed. (NOTE: Make of SPD shall be as OEM or any other make as specifically approved by GE) |
| 39 | S&F Connector suitable for fixing of Cable of size Cross sectional area 25 Sqmm to 50 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and directed. NOTE : MAKE of Connector shall be provided as per Light Fittings.Make available at Site :- (Havells/ Bajaj/ Surya/ Crompton/ Halonix). |
| 40 | S&F in repair 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tapewire one twin core cable flat or circular stranded aluminium conductor of 10 sq mm size complete all as specified and directed. |
| 41 | S&F in repair Sheet metal enclosure for DBs for MCB, SPN, 2 way, 240 Volt , AC, Single Door including 01 No, MCB SPN 40-63 Amps, 415 Volts, 10 kA, \"C\" curvec omplete all as specified and diredted.((NOTE: Cost of MCB is deemed to be inclusive in the quoted rate) |
| 42 | S&F in repair Bracket/Arm suitable for street light fittings, made out of 25 mm bore (light grade) GI pipe length not exceeding 1.20 metre long, fixed with 02 sets of flat iron clamp of size 40mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed. |
| 43 | -ditto- but bracket with 32 mm bore light grade GI pipe |
| 44 | S&F in repair cable joint termination junction box PVC body housing of size 200x160x98 mm suitable for housing and including 100 amps rated aluminium bus bar, 3 phase, 4 wire system mounted on PVC insulators for one incomming and two out going cable entry space mounted on street light PCC/ tubular pole with 25x3 mm FI clamps with nut, bolts and washers and including one 6 to 10 amps MCB, SP, 240 volt for street light supply complete all asdirected by Engr-in-Charge.(MAKE OF JUNCTION BOX: HENSEL Cat No: KM 9250 OR EQUIVALENT MODEL IN SCHNEIDER / RITTAL / SPELSBERG)(NOTE: Cost of MCB, Busbar, Din Rail, connector, clamps etc is deemed to be inclusive in the quoted rate) |
| 45 | S&F in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-.(a) minimum system efficacy 120 lumen/watt(b) CRI not less than 70,(c) THD < 10%(d) Power Factor not less than 0.90(e) having in built short circuit and surge protection upto 4 kV(f) having 10 KV external surge protection (for 45 watt & above)(g) colour temperature not less than 5700 degree K(h) life not less than 50000 hours of operation(NOTE: After dismantling, all luminaries shall be inspected & tested for unserviceability justifying replacement of luminaire) |
| 46 | 45 Watt Street Light Luminaire |
| 47 | 60 Watt Street Light Luminaire |
| 48 | 70-72 Watt Street Light Luminaire |
| 49 | 90 Watt Street Light Luminaire |
| 50 | S&F in repairs LED Flood Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver andtoughened glass cover, IP66 grade ingress protection, impact resistance IK07 complete all as specified and directed and complying with the following specifications:-.(a) minimum system efficacy 120 lumen/watt(b) CRI not less than 70,(c) THD < 10%(d) Power factor not less than 0.90(e) having in built short circuit and surge protection upto 4 kV(f) having 10 KV external surge protection (g) colour temperature not less than 5700 degree K(h) life not less than 50000 hours of operation(NOTE: After dismantling, all luminaries shall be inspected & tested for unserviceability justifying replacement of luminaire) |
| 51 | 70 Watt Flood Light Luminaire |
| 52 | 100 Watt Flood Light Luminaire |
| 53 | 150 Watt Flood Light Luminaire |
| 54 | 200 Watt Flood Light Luminaire |
| 55 | S&F in repair 50 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or under roads/floors/culverts and/or fixing to electric poles with suitable size mild steel flar iron clamps, bolts, nuts & washers etc complete all as specified and as directed. |
| 56 | S&F in repair LED post top luminiare, 25 watt, with die cast amuninium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver complete all as specified an directed.(Make : BAJAJ, Cat No: BGCTN 25W LED WW /HALONIX, Cat No: HLPT-04-25CW / HAVELLS, Model: RUBY / ORIENT, Cat No: OSL-MARFICPT025W or equivalent model in other makes specified in tender) )NOTE: Wire for conection of luminaire shall be measured and paid seperately. |
| 57 | Demolition of plain cement concrete (coping of PCC/GI pole/Road) of any description and in any position including removal of debris outside AF land and disposed off completeand as directed. |
| 58 | Dismantling of unserviceable/old steel/concrete poles of any type & size including concrete foundationand removal from site complete all as specified and directed. |
| 59 | S&F Steel Tubular swagedpoles of size 9.00 mtr long, Type 410 SP-31 complete with cast iron/ M S base plate, finial taper plug, bolts, nuts & washer including painting with two coats of Aluminium paint over a coat of Red oxide primer on exposed surfaces and two coats of black bituminous paint over the embedded portion of poles complete all as specified and as directed. (NOTE : Excavation, Earthwork, PCC Foundation shall be measured and paid seperately) |
| 60 | M&L for hardcore of gauge exc 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken bricks for making good road cutting portion complete all as specified and directed. |
| 61 | M&L for PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed. |
| 62 | M&L for PCC 1:3:6 (nominal mix) type C-1 using 20mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 63 | M&L for PCC 1:2:4 (nominal mix) type B-1 using 20mm graded crushed stone aggregate as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating, finishing surface even and smooth without using extra cementincluding necessary form work complete all as specified and directed. |
| 64 | M&L for preparation of concrete surfaces and and applying two coats of cement base paint over cement wash with portland cement slurry for smooth wall finish complete all as specified and directed. |
| 65 | S&F in repair Thermoplastic Polyamide Glands with Lock Nuts Made of Polyamide of size M32 as per site requirement, complete all as specified and as directed. |
| 66 | M&L for scraping of old paint from thesteel tubular poles up to 9 mtr height with out removing accessories and preparationof surfaces and repainting the pole with one coat of aluminium paint with alternative white and black stripes of 30 cm each upto 1.5 mtr height using synthetic enamel paint and repainting the remaining pole and iron parts i.e U clamps, channels etc above 1.5 mtr height by applying one coat of aluminium paintall as required at site complete all as specified and directed. |
| 67 | M&L for disconnecting and taking up unserviceable LT cable of any size and repairing the cable with fresh joint with and including necessary insulating material, thimbles, lugs etc and reconnection as per original layout including testing on completion complete all as specified and directed. |
| 68 | Trimming/Prunning of tree branches upto 100mm thick and around 1.50 mtr from HT/LT OH line and disposal of waste trims outside AF land complete all as specified and directed.(NOTE: Quoted rate is deemed to include for all labour, safety gear, T&P and vehicles for execution of the aforesaid work. No claim shall be entertained at a later date) |